Windows Server 2008 R2 and Hyper-V 2008 Host Configuration

Similar documents
Configuring a Microsoft Windows Server 2012/R2 Failover Cluster with Storage Center

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2008

QNAP and Failover Technologies

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

How To Set Up A Two Node Hyperv Cluster With Failover Clustering And Cluster Shared Volume (Csv) Enabled

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2003

StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers

Deploying Windows Streaming Media Servers NLB Cluster and metasan

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

StarWind iscsi SAN Configuring HA File Server for SMB NAS

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

Dell Compellent Storage Center

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008

LOAD BALANCING 2X APPLICATIONSERVER XG SECURE CLIENT GATEWAYS THROUGH MICROSOFT NETWORK LOAD BALANCING

Configuring Network Load Balancing with Cerberus FTP Server

StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec

Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V

If you already have your SAN infrastructure in place, you can skip this section.

StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

StarWind iscsi SAN Software: Configuring High Availability Storage for VMware vsphere and ESX Server

Install MS SQL Server 2012 Express Edition

istorage Server: High-Availability iscsi SAN for Windows Server 2008 & Hyper-V Clustering

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

StarWind iscsi SAN Software: Challenge-Handshake Authentication Protocol (CHAP) for Authentication of Users

Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2

Clustering VirtualCenter 2.5 Using Microsoft Cluster Services

StarWind iscsi SAN Software: Using StarWind with VMware ESX Server

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

StarWind iscsi SAN: Configuring Global Deduplication May 2012

NovaBACKUP xsp Version 12.2 Upgrade Guide

CONFIGURING MNLB FOR LOAD BALANCING EXCHANGE 2013 CU2 CAS SERVERS FOR HIGH AVAILABILITY

Setup Guide for Exchange Server

HP ProLiant DL380 G5 High Availability Storage Server

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance

Drobo How-To Guide. Topics. What You Will Need. Configure Windows iscsi Multipath I/O (MPIO) with Drobo iscsi SAN

Dell Networking Solutions Guide for Microsoft Hyper-V

StarWind iscsi SAN & NAS: Multipathing October 2012

NovaBACKUP xsp Version 15.0 Upgrade Guide

Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX

Setting up your laptop to print to the student lounge printer

Deploying Microsoft Hyper-V with Dell EqualLogic PS Series Arrays

Configuring a FlexPod for iscsi Boot

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

Iridium Extreme TM Satellite Phone. Data Services Manual

Operating System Recommended Support Contract

Printing Options. Netgear FR114P Print Server Installation for Windows XP

WhatsUp Gold v16.3 Installation and Configuration Guide

Networking Solutions Guide

SmartSync Monitor Help

General Tips: Page 1 of 20. By Khaled Elshaer.

istorage Server: High Availability iscsi SAN for Windows Server 2012 Cluster

Frequently Asked Questions k. Third-party information brought to you courtesy of Dell. NIC Partitioning (NPAR) FAQs

How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade

Package Contents. D-Link DSN-3200/3400 Installation Guide. DSN-3200/3400 xstack Storage Area Network (SAN) Array. CD-ROM with User Guide.

Our target is an EqualLogic PS100 Storage Array with a portal address of

StarWind iscsi SAN Software: Using with Citrix XenServer

Biznet GIO Cloud Connecting VM via Windows Remote Desktop

138 Configuration Wizards

Windows Firewall Configuration with Group Policy for SyAM System Client Installation

Host Installation on a Terminal Server

ActiveImage Protector 3.5 for Hyper-V with SHR. User Guide - Back up Hyper-V Server 2012 R2 host and

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

Dell High Availability Solutions Guide for Microsoft Hyper-V

BioWin Network Installation

CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES

NSi Mobile Installation Guide. Version 6.2

Reason 8 Multi Licenses

To add Citrix XenApp Client Setup for home PC/Office using the 32bit Windows client.

Defender EAP Agent Installation and Configuration Guide

Using SMI-S for Management Automation of StarWind iscsi SAN V8 beta in System Center Virtual Machine Manager 2012 R2

Installation Guide July 2009

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

Setup for Failover Clustering and Microsoft Cluster Service

StarWind SMI-S Agent: Storage Provider for SCVMM April 2012

vsphere Networking ESXi 5.0 vcenter Server 5.0 EN

Windows Vista / Windows 7 Installation Guide

Network Load Balancing

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Microsoft Exchange Mailbox Software Setup Guide

Configuring Windows Server Clusters

Interfacing Basler GigE Cameras With Cognex VisionPro 7.2

Defender Token Deployment System Quick Start Guide

Creating a New Database and a Table Owner in SQL Server 2005 for exchange@pam

MODEM AND DIAL-UP. Installation/Configuration (Windows 95/98/Me/NT/2000/XP)

QUANTIFY INSTALLATION GUIDE

NTP Software QFS for NAS, Hitachi Edition

DP-313 Wireless Print Server

Enterprise Manager. Version 6.2. Installation Guide

Drobo How-To Guide. Topics. What You Will Need. Configure Drobo iscsi SAN as Backend Storage for Active Directory File Servers

Windows 2000/XP Network

Windows 98 and Windows Me

Setting up VMware ESXi for 2X VirtualDesktopServer Manual

StarWind iscsi SAN Software: Implementation of Enhanced Data Protection Using StarWind Continuous Data Protection

Compellent Storage Center

SysAid Remote Discovery Tool

Quick Start Guide. Cerberus FTP is distributed in Canada through C&C Software. Visit us today at

Transcription:

Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series March 2013 SISfeedback@Dell.com

Revisions Date April 2012 May 2012 December 2012 March 2013 Status Initial release Updated the Intel NIC driver version and EQL host installation kit for Windows version 4.0.0 Combined part 1 and part 2 into single guide Added Hyper-V 2008 content 2013 Dell Inc. All rights reserved. Dell, the Dell logo, and other Dell names and marks are trademarks of Dell Inc. in the US and worldwide. All trademarks and registered trademarks mentioned herein are the property of their respective owners. 2 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

This document is one part of a complete installation guide series from the Rapid EqualLogic Configuration Portal. Please make sure that you have the complete set for your configuration before proceeding. Full link to document site: http://en.community.dell.com/techcenter/storage/w/wiki/3615.rapid-equallogic-configuration-portalby-sis.aspx Note: For instructions on enabling the Hyper-V role for a Windows 2008 Server, go to: http://technet.microsoft.com/en-us/library/cc794929(v=ws.10).aspx Note: To enable Hyper-V to use volumes located on the EqualLogic iscsi SAN, you must first complete the configuration instructions provided in this guide. 3 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

1 NIC device driver update and installation This configuration is for Windows Server 2008 R2 hosts. 1.1 Download the latest driver update for the Intel NICs Note: The following procedure is for an Intel 1G or 10G NIC. If you are using Broadcom network adapters (NICS) for SAN connectivity, proceed to Download the latest driver update for Broadcom NICs. 1. Go to http://support.dell.com and click Start Here under Support for Small Business. 2. In the Drivers and Downloads menu, select Drivers Home. If the support site has detected a product to support, click Change Your Product. 3. In the Choose a Model section, click Select a Model. 4. Select Servers, Storage, Networking from the Select Your Product Family list, and PowerEdge Server from the Select Your Product Line list. 5. Select your host server platform (i.e. Dell PowerEdge R610, etc.) from the Select Your Product Model list, and then click Confirm. 6. In the Refine Your Results window, select Windows Server 2008 R2 for the Operating System, and Network as the Category. 7. Download the recent version of the Intel driver package for Intel PCI-E 10Gig and 1Gig Family of Server Adapters. Download version 13.0.0 or later. 4 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

1.2 Install the Intel driver update 1. Click Install to start, and then click Next. 2. After accepting the license, make sure that only Drivers, Intel(R) PROset, and Advanced Network Services are selected as shown and click Next. 3. Click Next and then Install to complete the installation. 5 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

1.3 Configure the Intel network adapters (NICS) After installation of the Intel driver, launch the Windows device manager and expand Network adapters. You should see the Intel NICs listed, as shown. For each Intel NIC that will be connected to the SAN, you need to change the following settings: 1. In Device Manager, double click the Intel NIC used for SAN traffic. 2. In the Properties dialog box, click the Advanced tab to configure the NIC settings. 3. Set the Jumbo Packet value to 9014 Bytes and click OK. Repeat these steps for all the NICs used for SAN traffic. 1.4 Download the latest driver update for Broadcom NICs Note: The following procedure is for a Broadcom NIC. If you are using Intel Network Adapters (NICs), refer to the previous section titled, Downloading the latest driver update for the Intel NICs. 1. Go to http://support.dell.com and click Start Here under Support for Small Business. 2. In the Drivers and Downloads menu, select Drivers Home. If the support site has detected a product to support, click Change Your Product. 3. In the Choose a Model section, click Select a Model. 4. Select Servers, Storage, Networking from the Select Your Product Family list, and PowerEdge Server from the Select Your Product Line list. 5. Select your host server platform (i.e. Dell PowerEdge R610, etc.) from the Select Your Product Model list, and then click Confirm. 6 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

6. In the Refine Your Results window, select Windows Server 2008 R2 for the Operating System, and Network as the Category. 7. Download the most recent version of the Broadcom driver package for NetXtreme II Family of Adapters. Download version 16.2.1 or later. 1.5 Install the Broadcom driver update 1. Launch the Broadcom driver installation update. 2. At the custom setup screen, select the Control Suite and BASP features as shown, and click Next. 3. If the installation procedure prompts to enable System TCP Chimney Offload, select No. 7 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

1.6 Configure Broadcom NIC device settings using BACS Launch the Broadcom Advanced Configuration Suite (BACS) tool by going to Start > All Programs > Broadcom. 1. On the left pane, click on the NIC port. 2. On the right pane, click the Configurations tab. 3. Perform the following steps on each NIC port connected to the SAN network. a. Leave all values at default except for the following: Option Flow control Value Rx & Tx Enabled Jumbo MTU 9000 b. Click Apply to save the changes. c. Exit Broadcom Advanced Control Suite. 8 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

2 Configure networking 2.1 Configure and optimize the NIC ports to be used for SAN connectivity. 1. In the NIC properties, disable (uncheck) all protocols except Internet protocol Version 4 (TCP/IPv4). Note: If using Broadcom NICs, the Broadcom Advanced Server Program Drivers are protected and cannot be disabled. 2. Double click Internet Protocol Version 4 (TCP/IPv4) to enter the appropriate IP address for each SAN connected port (refer to the Prerequisites Table in Preparation document selected from the Rapid EqualLogic Configuration Portal), and then click Advanced Settings. 9 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

3. In the advanced settings properties, open the WINS tab and uncheck Enable LMHOSTS lookup and choose Disable NetBIOS over TCP/IP as the NetBIOS setting. 4. Repeat the steps above to configure and optimize each NIC port to be used for SAN connectivity. 10 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

3 Install EQL HIT kit Download the latest Host Integration Tools kit from https://support.equallogic.com/secure/login.aspx. In Windows Explorer, double click the downloaded file to run the setup. 1. Select the complete installation option, and then click Next. 2. At the Installation Complete screen, uncheck the Launch Remote Setup Wizard checkbox and then click Finish. 3. When the following message is displayed, click Yes to restart the system. 11 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

4 Configure the SAN switch fabric If you have already configured your SAN switches, continue to the next section. If not, refer to the specific instructions for configuring each switch model in the Rapid EqualLogic Configuration Portal. 5 Configure the storage 5.1 Configure the array If you have already configured the storage array, continue to section 5.2. If you have not completed the array configuration, then complete the steps for array configuration using the instructions in the Rapid EqualLogic Configuration Portal. 5.2 Edit volume access permissions for Windows host The following steps will be performed at the Windows host that will access a volume on the storage. 1. On the Start menu click Administrative Tools > iscsi Initiator. 2. In the configuration tab, locate the Initiator name field and copy the contents. 12 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

3. The next screen image illustrates how to use the iscsi initiator name to limit iscsi access. Tip: Use this screen to edit initiator names for existing volumes. Paste iscsi initiator name here. 4. If you need to allow simultaneous connections from initiators with different IQN names, check the box in Access type. Note: This is usually only necessary if the Windows node will be part of a failover cluster. 13 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

6 Configure iscsi target discovery To configure the host for iscsi and target discovery, use the remote setup wizard as described in this section. 1. Open the remote setup wizard by clicking Start > All Programs > EqualLogic > Remote Setup Wizard. 2. Chose Configure this computer to access a PS Series SAN, as shown, and then click Next. 3. Click Add Group. 14 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

4. Enter the group name and in-band group IP address. Click Save and then Finish. 15 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

7 Remote setup wizard to configure host MPIO settings 1. Open the remote Setup wizard by clicking Start > All Programs > EqualLogic > Remote Setup Wizard. 2. Select the radio button for Configure MPIO settings for this computer and click Next. 3. In the Configure MPIO settings for this computer screen, exclude any network not used for iscsi SAN traffic (for example, the client LAN or management network). Click Finish. 16 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

8 Volume access 1. Open the iscsi Initiator on a Windows host machine by clicking Start > Administrative Tools > iscsi Initiator. 2. Click the Targets tab to view the iscsi target for the volume created on the array member. 3. Click Refresh to rescan the ISCSI targets. 4. Select a target to connect to and click Connect. 17 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

5. Click OK to confirm the connection. Repeat steps 4 and 5 of Volume access for the remaining volumes. 6. Click OK to close the iscsi initiator properties. 7. Open Start > Administrative Tools > Server Manager. 8. Click Storage > disk management. 9. Right click the new (unknown) disk and choose online. 18 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series

10. Right click the new (uninitialized) disk and choose Initialize Disk. 11. Choose MBR or GPT (for volumes greater than 2TB in size) and then click OK. 12. Right click on the unallocated volume and choose Simple Volume. Follow the steps in the wizard to create a partition and format the volume for Windows. 19 Windows Server 2008 R2 and Hyper-V 2008 Host Configuration Rapid EqualLogic Configuration Series