StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2008
|
|
|
- Brett Dennis
- 9 years ago
- Views:
Transcription
1 StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server Copyright All rights reserved.
2 COPYRIGHT Copyright All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of. TRADEMARKS StarWind, and the StarWind and the logos are trademarks of which may be registered in some jurisdictions. All other trademarks are owned by their respective owners. CHANGES The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. reserves the right to make changes in the product design without reservation and without notification to its users. TECHNICAL SUPPORT AND SERVICES If you have questions about installing or using this software, check this and other documents first - you will find answers to most of your questions here or there. If you need further assistance, please contact us.
3 Table of Contents Introduction... 4 Configuring... StarWind Server 6 Preparing... Quorum Volume 6 Preparing... Generic Volume 13 Preparing... Cluster Nodes 21 Node Node Configuring... Microsoft Cluster Service 68 Validate... a Configuration 68 Create... a Cluster 75 Adding New... Shared Disk Resource 82 StarWind... Target 82 Node Node Copyright All rights reserved. 3
4 Guide Introduction Software clustering technology enables you to make several servers to work as a unit. Various cluster configurations can be implemented. One of the most frequently used configurations is the failover cluster. This configuration assumes that if one of the cluster nodes fails, the reserved node automatically brings online, serving the applications. With that the workflow remains uninterrupted and secured. Failover cluster configuration includes two (or more) server nodes that share an external storage. Based on the iscsi technology, StarWind Softwafe Inc. StarWind enables to create an external storage in Windows environment without implementation of expensive FC or external SCSI solutions. With StarWind you can create a shared disk array on a host running Microsoft Windows. Copyright All rights reserved. 4
5 This document gives you detailed step-by-step instructions on StarWind configuring for failover clusters. Copyright All rights reserved. 5
6 Configuring StarWind Server Preparing Quorum Volume Launch the StarWind Management Console selecting Start -> All Programs -> -> StarWind -> StarWind. After the console is launched its icon appears in the system tray. Double click the icon with the left mouse button or single click it with the right and select Start Management pop-up menu item. From the StarWind Servers tree please select the computer you wish to connect to. Press the right mouse button over the desired host (computer) and select the Connect menu item. You will be prompted to enter the login and password. Default ones are: root, starwind. You can always change them later. After you have successfully connected to the StarWind Service, please click the right mouse button over the desired host (computer) and select Add Target pop-up menu item. In the wizard that appears, select a target name. The name must be a unique name by which the device will be declared to the iscsi initiators connecting to StarWind over an IP network. Press the Next button to continue. Copyright All rights reserved. 6
7 Select Image File device. Press the Next button to continue. Copyright All rights reserved. 7
8 Select Create new virtual disk to create a new virtual hard disk or Mount existing virtual disk to mount an existing virtual disk that you ve prepared before. Press the Next button to continue. Copyright All rights reserved. 8
9 If you have decided to create a new virtual disk please specify the location and the name of the virtual disk you wish to be created. Also you have to provide the virtual disk size in megabytes. Check any additional parameters of the virtual disk you wish to create. Please refer to the online help for details regarding those additional parameters (Compressed and Encrypted). Press the Next button to continue. Copyright All rights reserved. 9
10 Image File device has some extra parameters. Check Allow multiple concurrent iscsi connections (clustering) checkbox. Please refer to the online help for details regarding those additional parameters (Asynchronous mode, Allow multiple connections (clustering), Read-only mode and Specify advanced options). Press the Next button to continue. Copyright All rights reserved. 10
11 Check the device parameters are correct. Press the Back button should any changes be required. Press the Next button to continue. Copyright All rights reserved. 11
12 A summary of the created device is displayed on the last wizard page (see image below). Press the Finish button to close the wizard. Copyright All rights reserved. 12
13 Preparing Generic Volume Click the right mouse button over the host and select Add Target pop-up menu item. In the wizard that appears, select a target name. The name must be a unique name by which the device will be declared to the iscsi initiators connecting to StarWind over an IP network. Press the Next button to continue. Copyright All rights reserved. 13
14 Select Image File device. Press the Next button to continue. Copyright All rights reserved. 14
15 Select Create new virtual disk to create a new virtual hard disk or Mount existing virtual disk to mount an existing virtual disk that you ve prepared before. Press the Next button to continue. Copyright All rights reserved. 15
16 If you have decided to create a new virtual disk please specify the location and the name of the virtual disk you wish to be created. Also you have to provide the virtual disk size in megabytes. Check any additional parameters of the virtual disk you wish to create. Please refer to the online help for details regarding those additional parameters (Compressed and Encrypted). Press the Next button to continue. Copyright All rights reserved. 16
17 Image File device has some extra parameters. Check Allow multiple concurrent iscsi connections (clustering) checkbox. Please refer to the online help for details regarding those additional parameters (Asynchronous mode, Allow multiple connections (clustering), Read-only mode and Specify advanced options). Press the Next button to continue. Copyright All rights reserved. 17
18 Check the device parameters are correct. Press the Back button should any changes be required. Press the Next button to continue. Copyright All rights reserved. 18
19 A summary of the created device is displayed on the last wizard page (see image below). Press the Finish button to close the wizard. Copyright All rights reserved. 19
20 If successful, the StarWind Console should look like the sample image provided below. Copyright All rights reserved. 20
21 Preparing Cluster Nodes Node 1 Configuring iscsi initiator Launch the Microsoft iscsi Software Initiator application Administrative Tools -> iscsi Initiator Select the Discovery Tab. Copyright All rights reserved. 21
22 In the Target Portals group, click the Add Portal... button. Press the Add Portal... button. Copyright All rights reserved. 22
23 In the Add Target Portal dialog enter IP address or DNS name of the StarWind target server. Press the OK button to continue. Copyright All rights reserved. 23
24 Click on the Targets tab. Select the IQN of the target just added. Press the Log On button. Copyright All rights reserved. 24
25 The Log On to Target dialog now appears. In this dialog click on the checkbox Automatically restore this connection when the system boots to make this connection persistent. Press the OK button to continue. Press the OK button to continue. Copyright All rights reserved. 25
26 If successful, the initiator is now logged on to StarWind. Copyright All rights reserved. 26
27 Initializing, formatting and creating partitions When the StarWind Disks are connected, they show up on the initiator machine as new disk devices. Before these devices can be used as cluster disks, they have to be initialized and formatted. Launch the Computer Management console. Select Disk Management. Copyright All rights reserved. 27
28 Bring disks online. Press the right mouse button over the disk and select Online. Copyright All rights reserved. 28
29 Copyright All rights reserved. 29
30 Initialize the Disks. Press the right mouse button over the Disk and select Initialize Disk. Follow the wizard to initialize the new disks. Copyright All rights reserved. 30
31 Press the OK button to continue. Copyright All rights reserved. 31
32 Both disks have now been initialized. Copyright All rights reserved. 32
33 Right-click over the unallocated space and select New Simple Volume. Follow the instructions in the wizard to create an NTFS partition for use as the quorum disk. Copyright All rights reserved. 33
34 New Simple Volume Wizard appears. Press the Next button to continue. Copyright All rights reserved. 34
35 Specify new volume size in megabytes. Press the Next button to continue. Copyright All rights reserved. 35
36 Choose the Drive Letter to assign. Press the Next button to continue. Copyright All rights reserved. 36
37 Specify format options. Provide the Volume Label. Press the Next button to continue. Copyright All rights reserved. 37
38 Check the settings are correct. Press the Back button should any changes be required. Press the Finish button to close the wizard. Copyright All rights reserved. 38
39 If successful, a new volume will be created as shown in the example image below. Repeat the same steps to create the second volume. Right-click over the unallocated space and select New Simple Volume. Follow the instructions in the wizard to create an NTFS partition for use as the generic disk. Copyright All rights reserved. 39
40 New Partition Wizard appears. Press the Next button to continue. Copyright All rights reserved. 40
41 Specify new volume size in megabytes. Press the Next button to continue. Copyright All rights reserved. 41
42 Choose the Drive Letter to assign. Press the Next button to continue. Copyright All rights reserved. 42
43 Specify format options. Provide the Volume Label. Press the Next button to continue. Copyright All rights reserved. 43
44 Check the settings are correct. Press the Back button should any changes be required. Press the Finish button to close the wizard. Copyright All rights reserved. 44
45 If successful, both of the disks are now formatted as shown in the example image below. Copyright All rights reserved. 45
46 Installing Failover Clustering Feature Launch the Computer Management console. Select Features node from the list. Click the Add Features to continue. Copyright All rights reserved. 46
47 Add Features Wizard appears. Check the Failover Clustering feature. Press the Next button to continue. Copyright All rights reserved. 47
48 Check that the parameters are correct. Press the Previous button should any changes be required. Complete the installation of the Failover Clustering Feature by pressing the Install button. Copyright All rights reserved. 48
49 If the feature is successfully installed, the wizard should look similar to the example image below. Press the Close button. Shut down the server. Copyright All rights reserved. 49
50 Node 2 Configuring iscsi initiator Launch the Microsoft iscsi Software Initiator application Administrative Tools -> iscsi Initiator Select the Discovery Tab. Copyright All rights reserved. 50
51 In the Target Portals group, click the Add Portal... button. Press the Add Portal... button. Copyright All rights reserved. 51
52 In the Add Target Portal dialog enter IP address or DNS name of the StarWind target server. Press the OK button to continue. Copyright All rights reserved. 52
53 Click on the Targets tab. Select the IQN of the target just added. Press the Log On button. Copyright All rights reserved. 53
54 The Log On to Target dialog now appears. In this dialog click on the checkbox Automatically restore this connection when the system boots to make this connection persistent. Press the OK button to continue. Press the OK button to continue. Copyright All rights reserved. 54
55 If successful, the initiator is now logged on to StarWind. Copyright All rights reserved. 55
56 Assigning drive letters When the StarWind Disks are connected, they show up on the initiator machine as new disk devices. Before these devices can be used as cluster disks, they have to be mounted. Launch the Computer Management console. Select Disk Management. Copyright All rights reserved. 56
57 Bring disks online. Press the right mouse button over the disk and select Online. Copyright All rights reserved. 57
58 Copyright All rights reserved. 58
59 The picture below shows that Windows has automatically assigned Drive Letters to the mounted volumes. As these are local drive letters they may not be the same as we have assigned to these volumes on the first node. However, as all volumes of a cluster must be assigned the same drive letters, any differences must be manually changed. Press the right mouse button over the Quorum volume. Select Change Drive Letter and Paths... Copyright All rights reserved. 59
60 Change the Drive Latter for the Quorum to Q. Copyright All rights reserved. 60
61 Press the right mouse button over the Generic volume. Select Change Drive Letter and Paths... Copyright All rights reserved. 61
62 Change the Drive Latter for the Generic to R. Copyright All rights reserved. 62
63 If successful, the Computer Management console should look like the sample image provided below. Copyright All rights reserved. 63
64 Installing Failover Clustering Feature Launch the Computer Management console. Select Features node from the list. Click the Add Features to continue. Copyright All rights reserved. 64
65 Add Features Wizard appears. Check the Failover Clustering feature. Press the Next button to continue. Copyright All rights reserved. 65
66 Check that the parameters are correct. Press the Previous button should any changes be required. Complete the installation of the Failover Clustering Feature by pressing the Install button. Copyright All rights reserved. 66
67 If the feature is successfully installed, the wizard should look similar to the example image below. Press the Close button. Shut down the server. Copyright All rights reserved. 67
68 Configuring Microsoft Cluster Service Validate a Configuration Start both Cluster Node 1 Server and Cluster Node 2 Server. Launch the Failover Cluster Management console selecting Administrative Tools>Failover Cluster Management. After the management console is launched please click Validate a Configuration... item to ensure that the configuration is suitable for failover clustering. Copyright All rights reserved. 68
69 Validate a Configuration Wizard appears. Press the Next button to continue. Copyright All rights reserved. 69
70 Add the names of servers you wish to use as cluster nodes. Press the Next button to continue. Copyright All rights reserved. 70
71 Select Run all tests (recommended) for testing the complete configuration. Press the Next button to continue. Copyright All rights reserved. 71
72 Check the parameters are correct. Press the Previous button should any changes be required. Press the Next button to continue. Copyright All rights reserved. 72
73 If all of the tests are successful, the wizard should look similar to the example image below. Copyright All rights reserved. 73
74 If successful, the wizard should look like the example picture provided below. Press the Finish button. Copyright All rights reserved. 74
75 Create a Cluster It is now time to create the cluster. Click Create a Cluster item from the Actions panel shown on the right. Copyright All rights reserved. 75
76 Create a Cluster Wizard appears. Press the Next button to continue. Copyright All rights reserved. 76
77 Add the names of servers you wish to use as cluster nodes. Press the Next button to continue. Copyright All rights reserved. 77
78 Specify Cluster Name and Cluster IP address. Press the Next button to continue. Copyright All rights reserved. 78
79 Check the parameters are correct. Press the Previous button should any changes be required. Press the Next button to continue. Copyright All rights reserved. 79
80 If successful, the wizard should look like the example picture provided below. Press the Finish button. Copyright All rights reserved. 80
81 Now that the creation of the cluster is complete it will be shown in the panel on the left. Expand the cluster by clicking on the + symbol next to the cluster, then click on Storage. The Failover Cluster Management console should look like the example picture provided below. Both cluster disk resources will be shown as online. Copyright All rights reserved. 81
82 Adding New Shared Disk Resource StarWind Target Click the right mouse button over the host and select Add Target pop-up menu item. In the wizard that appears, select a target name. The name must be a unique name by which the device will be declared to the iscsi initiators connecting to StarWind over an IP network. Press the Next button to continue. Copyright All rights reserved. 82
83 Select Image File device. Press the Next button to continue. Copyright All rights reserved. 83
84 Select Create new virtual disk to create a new virtual hard disk or Mount existing virtual disk to mount an existing virtual disk that you ve prepared before. Press the Next button to continue. Copyright All rights reserved. 84
85 If you have decided to create a new virtual disk please specify the location and the name of the virtual disk you wish to be created. Also you have to provide the virtual disk size in megabytes. Check any additional parameters of the virtual dsik you wish to create. Please refer to the online help for details regarding those additional parameters (Compressed and Encrypted). Press the Next button to continue. Copyright All rights reserved. 85
86 Image File device has some extra parameters. Check Allow multiple concurrent iscsi connections (clustering) checkbox. Please refer to the online help for details regarding those additional parameters (Asynchronous mode, Allow multiple connections (clustering), Read-only mode and Specify advanced options). Press the Next button to continue. Copyright All rights reserved. 86
87 Check the device parameters are correct. Press the Back button should any changes be required. Press the Next button to continue. Copyright All rights reserved. 87
88 A summary of the created device is displayed on the last wizard page (see image below). Press the Finish button to close the wizard. Copyright All rights reserved. 88
89 Node 1 Launch the Microsoft iscsi Software Initiator application Administrative Tools -> iscsi Initiator. Click on the Targets tab. Select the IQN of the target just added. Press the Log On button. Copyright All rights reserved. 89
90 The Log On to Target dialog now appears. In this dialog click on the checkbox Automatically restore this connection when the system boots to make this connection persistent. Press the OK button to continue. Copyright All rights reserved. 90
91 When the StarWind Disks are connected, they show up on the initiator machine as new disk devices. Before these devices can be used as cluster disks, they have to be initialized and formatted. Launch the Computer Management console. Select Disk Management. Bring disk online. Press the right mouse button over the disk and select Online. Copyright All rights reserved. 91
92 Initialize the Disk. Press the right mouse button over the Disk and select Initialize Disk. Follow the wizard to initialize the new disk. Copyright All rights reserved. 92
93 Press the OK button to continue. Copyright All rights reserved. 93
94 The disk has now been initialized. Right-click over the unallocated space and select New Simple Volume. Follow the instructions in the wizard to create an NTFS partition for use as the spool disk. Copyright All rights reserved. 94
95 New Simple Volume Wizard appears. Press the Next button to continue. Copyright All rights reserved. 95
96 Specify new volume size in megabytes. Press the Next button to continue. Copyright All rights reserved. 96
97 Choose the Drive Letter to assign. Press the Next button to continue. Copyright All rights reserved. 97
98 Specify format options. Provide the Volume Label. Press the Next button to continue. Copyright All rights reserved. 98
99 Check the settings are correct. Press the Back button should any changes be required. Press the Finish button to close the wizard. Copyright All rights reserved. 99
100 If successful, the disk is now formatted as shown in the example image below. Shut down the node. Copyright All rights reserved. 100
101 Node 2 Launch the Microsoft iscsi Software Initiator application Administrative Tools -> iscsi Initiator. Click on the Targets tab. Select the IQN of the target just added. Press the Log On button. Copyright All rights reserved. 101
102 The Log On to Target dialog now appears. In this dialog click on the checkbox Automatically restore this connection when the system boots to make this connection persistent. Press the OK button to continue. Copyright All rights reserved. 102
103 When the StarWind Disks are connected, they show up on the initiator machine as new disk devices. Before these devices can be used as cluster disks, they have to be mounted. Launch the Computer Management console. Select Disk Management. Bring disks online. Press the right mouse button over the disk and select Online. Copyright All rights reserved. 103
104 The picture below shows that Windows has automatically assigned Drive Letters to the mounted volumes. As these are local drive letters they may not be the same as we have assigned to these volumes on the first node. However, as all volumes of a cluster must be assigned the same drive letters, any differences must be manually changed. Press the right mouse button over the Spool volume. Select Change Drive Letter and Paths... Copyright All rights reserved. 104
105 Change the Drive Latter for the Spool to S. Copyright All rights reserved. 105
106 If successful, the Computer Management console should look like the sample image provided below. Copyright All rights reserved. 106
107 Launch the Failover Cluster Management console. Click on Storage node. Click Add a Disk item from the Actions panel shown on the right. Copyright All rights reserved. 107
108 Add Disks to a Cluster dialog appears. Select the disk to add. Press the OK button to continue. Copyright All rights reserved. 108
109 When completed, the disk is now a cluster disk. Copyright All rights reserved. 109
110 Start the other servers in the cluster. Copyright All rights reserved. 110
111 Contacts Support: Support Forum: Sales US Headquarters Direct phone number: Fax: EMEA, APAC Direct phone numbers: Voice Mail: Inc. 40 Mall Rd., Burlington MA 01803, USA Copyright All rights reserved. 111
StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2003
StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2003 www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved.
StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec
StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved. No
StarWind iscsi SAN Software: Using StarWind with VMware ESX Server
StarWind iscsi SAN Software: Using StarWind with VMware ESX Server www.starwindsoftware.com Copyright 2008-2010. All rights reserved. COPYRIGHT Copyright 2008-2010. All rights reserved. No part of this
StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers
StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright
StarWind iscsi SAN Software: Using with Citrix XenServer
StarWind iscsi SAN Software: Using with Citrix XenServer www.starwindsoftware.com Copyright 2008-2010. All rights reserved. COPYRIGHT Copyright 2008-2010. All rights reserved. No part of this publication
StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core
StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved.
StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008
StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008 www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT
StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012
StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks of StarWind Software which
StarWind iscsi SAN Software: Challenge-Handshake Authentication Protocol (CHAP) for Authentication of Users
StarWind iscsi SAN Software: Challenge-Handshake Authentication Protocol (CHAP) for Authentication of Users www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011.
StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012
StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks of StarWind Software which
StarWind iscsi SAN Software: Implementation of Enhanced Data Protection Using StarWind Continuous Data Protection
StarWind iscsi SAN Software: Implementation of Enhanced Data Protection Using StarWind Continuous Data Protection www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright
StarWind iscsi SAN Software: Configuring High Availability Storage for VMware vsphere and ESX Server
StarWind iscsi SAN Software: Configuring High Availability Storage for VMware vsphere and ESX Server www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All
StarWind iscsi SAN & NAS: Multipathing October 2012
StarWind iscsi SAN & NAS: Multipathing October 2012 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks of StarWind Software which may be registered in
StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013
StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks
StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013
StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software
StarWind iscsi SAN Configuring HA File Server for SMB NAS
Hardware-less VM Storage StarWind iscsi SAN Configuring HA File Server for SMB NAS DATE: FEBRUARY 2012 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software
StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device
StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device www.starwindsoftware.com Copyright 2008-2009. All rights reserved. COPYRIGHT Copyright 2008-2009. All rights reserved. No
StarWind iscsi SAN: Configuring Global Deduplication May 2012
StarWind iscsi SAN: Configuring Global Deduplication May 2012 TRADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software that may be registered
StarWind SMI-S Agent: Storage Provider for SCVMM April 2012
StarWind SMI-S Agent: Storage Provider for SCVMM April 2012 TRADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software that may be registered
StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster
#1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind
StarWind RAM Disk: Using as RAM Disk Emulator
StarWind RAM Disk: Using as RAM Disk Emulator www.starwindsoftware.com Copyright 2008-2010. All rights reserved. COPYRIGHT Copyright 2008-2010. All rights reserved. No part of this publication may be reproduced,
StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster
#1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with MARCH 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the
StarWind iscsi SAN: Global Deduplication with Veeam Backup&Replication
StarWind iscsi SAN: Global Deduplication with Veeam Backup&Replication May 2012 TRADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software
VMware/Hyper-V Backup Plug-in User Guide
VMware/Hyper-V Backup Plug-in User Guide COPYRIGHT No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying,
Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2
Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2 Edwin Sarmiento, Microsoft SQL Server MVP, Microsoft Certified Master Contents Introduction... 3 Assumptions...
istorage Server: High-Availability iscsi SAN for Windows Server 2008 & Hyper-V Clustering
istorage Server: High-Availability iscsi SAN for Windows Server 2008 & Hyper-V Clustering Tuesday, Feb 21 st, 2012 KernSafe Technologies, Inc. www.kernsafe.com Copyright KernSafe Technologies 2006-2012.
StarWind Virtual SAN Hyper-Converged Platform Quick Start Guide
Hardware-less VM Storage StarWind Virtual SAN Hyper-Converged Platform Quick Start Guide DATE: MAY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software
Using SMI-S for Management Automation of StarWind iscsi SAN V8 beta in System Center Virtual Machine Manager 2012 R2
Using SMI-S for Management Automation of StarWind iscsi SAN V8 beta in System Center Virtual Machine Manager 2012 R2 September 2013 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind
ArCycle vmbackup. for VMware/Hyper-V. User Guide
ArCycle vmbackup for VMware/Hyper-V User Guide 2 Copyright Copyright ArCycle Software, Ltd., 2011-2014. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,
Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering
Multipathing I/O (MPIO) enables the use of multiple iscsi ports on a Drobo SAN to provide fault tolerance. MPIO can also boost performance of an application by load balancing traffic across multiple ports.
How to Configure a Secure Connection to Microsoft SQL Server
How to Configure a Secure Connection to Microsoft SQL Server 1993-2015 Informatica Corporation. No part of this document may be reproduced or transmitted in any form, by any means (electronic, photocopying,
Installing and Configuring a. SQL Server 2012 Failover Cluster
Installing and Configuring a SQL Server 2012 Failover Cluster Edwin M Sarmiento Applies to: SQL Server 2012 SQL Server 2014 P a g e 1 Copyright This document is provided as-is. Information and views expressed
Setting up VMware ESXi for 2X VirtualDesktopServer Manual
Setting up VMware ESXi for 2X VirtualDesktopServer Manual URL: www.2x.com E-mail: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples
istorage Server: High Availability iscsi SAN for Windows Server 2012 Cluster
istorage Server: High Availability iscsi SAN for Windows Server 2012 Cluster Tuesday, December 26, 2013 KernSafe Technologies, Inc www.kernsafe.com Copyright KernSafe Technologies 2006-2013.All right reserved.
User Guide. DocAve Lotus Notes Migrator for Microsoft Exchange 1.1. Using the DocAve Notes Migrator for Exchange to Perform a Basic Migration
User Guide DocAve Lotus Notes Migrator for Microsoft Exchange 1.1 Using the DocAve Notes Migrator for Exchange to Perform a Basic Migration This document is intended for anyone wishing to familiarize themselves
Using Symantec NetBackup with VSS Snapshot to Perform a Backup of SAN LUNs in the Oracle ZFS Storage Appliance
An Oracle Technical White Paper March 2014 Using Symantec NetBackup with VSS Snapshot to Perform a Backup of SAN LUNs in the Oracle ZFS Storage Appliance Introduction... 2 Overview... 3 Oracle ZFS Storage
Interact for Microsoft Office
Interact for Microsoft Office Installation and Setup Guide Perceptive Content Version: 7.0.x Written by: Product Knowledge, R&D Date: October 2014 2014 Perceptive Software. All rights reserved Perceptive
Failover Manager for WhatsUp Gold v16.0 Quick Start Guide
Failover Manager for WhatsUp Gold v16.0 Quick Start Guide Contents About the WhatsUp Gold Failover Manager Failover is a mechanism with the capacity to automatically switch from a primary installation
Deploying Windows Streaming Media Servers NLB Cluster and metasan
Deploying Windows Streaming Media Servers NLB Cluster and metasan Introduction...................................................... 2 Objectives.......................................................
Installing LearningBay Enterprise Part 2
Installing LearningBay Enterprise Part 2 Support Document Copyright 2012 Axiom. All Rights Reserved. Page 1 Please note that this document is one of three that details the process for installing LearningBay
Release 2.0. Cox Business Online Backup Quick Start Guide
Cox Business Online Backup Quick Start Guide Release 2.0 Cox Business Online Backup Quick Start Guide i IMPORTANT: You must notify Cox in advance if you would like to move or relocate your telephone Service.
Setting up Hyper-V for 2X VirtualDesktopServer Manual
Setting up Hyper-V for 2X VirtualDesktopServer Manual URL: www.2x.com E-mail: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples herein
Configuring a Custom Load Evaluator Use the XenApp1 virtual machine, logged on as the XenApp\administrator user for this task.
Lab 8 User name: Administrator Password: Password1 Contents Exercise 8-1: Assigning a Custom Load Evaluator... 1 Scenario... 1 Configuring a Custom Load Evaluator... 1 Assigning a Load Evaluator to a Server...
PRODUCT WHITE PAPER LABEL ARCHIVE. Adding and Configuring Active Directory Users in LABEL ARCHIVE
PRODUCT WHITE PAPER LABEL ARCHIVE Adding and Configuring Active Directory Users in LABEL ARCHIVE TEKLYNX International March 19, 2010 Introduction Now more than ever, businesses large and small alike are
Installing RMFT on an MS Cluster
Installing RMFT on an MS Cluster RMFT Software Version 2.4.3 Supported on: Windows Server 2003 Enterprise Edition Windows Server 2000 Advanced Windows Server 2003 Datacenter Edition Windows Server 2008
Using DBMoto 7 in a Microsoft Windows Cluster
Using DBMoto 7 in a Microsoft Windows Cluster Copyright This document is copyrighted and protected by worldwide copyright laws and treaty provisions. No portion of this documentation may be distributed
Setting up Hyper-V for 2X VirtualDesktopServer Manual
Setting up Hyper-V for 2X VirtualDesktopServer Manual URL: www.2x.com E-mail: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples
Introduction to Hyper-V High- Availability with Failover Clustering
Introduction to Hyper-V High- Availability with Failover Clustering Lab Guide This lab is for anyone who wants to learn about Windows Server 2012 R2 Failover Clustering, focusing on configuration for Hyper-V
StarWind Deduplication vs Nexenta Deduplication
StarWind Deduplication vs Nexenta Deduplication May 2012 RADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software that may be registered in
How To Set Up A Two Node Hyperv Cluster With Failover Clustering And Cluster Shared Volume (Csv) Enabled
Getting Started with Hyper-V and the Scale Computing Cluster Scale Computing 5225 Exploration Drive Indianapolis, IN, 46241 Contents Contents CHAPTER 1 Introduction to Hyper-V: BEFORE YOU START. vii Revision
Quick Start Guide For Ipswitch Failover v9.0
For Ipswitch Failover v9.0 Copyright 1991-2015 All rights reserved. This document, as well as the software described in it, is furnished under license and may be used or copied only in accordance with
Configuring Network Load Balancing with Cerberus FTP Server
Configuring Network Load Balancing with Cerberus FTP Server May 2016 Version 1.0 1 Introduction Purpose This guide will discuss how to install and configure Network Load Balancing on Windows Server 2012
Backing Up and Restoring Microsoft Hyper-V Server Virtual Machines. Cloud Attached Storage. February 2014 Version 4.0
Backing Up and Restoring Microsoft Hyper-V Server Virtual Machines Cloud Attached Storage February 2014 Version 4.0 Copyright 2009-2014 CTERA Networks Ltd. All rights reserved. No part of this document
User Manual. 3CX VOIP client / Soft phone Version 6.0
User Manual 3CX VOIP client / Soft phone Version 6.0 Copyright 2006-2008, 3CX ltd. http:// E-mail: [email protected] Information in this document is subject to change without notice. Companies names and data
LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)
LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide Rev. 03 (November, 2001) Copyright Statement Trademarks Copyright 1997 No part of this publication may be reproduced in any form or by any
Nexio Connectus Cluster Set Up with SQL Server Backend
Nexio Connectus Cluster Set Up with SQL Server Backend 2.1.2 3/20/2014 Edition: A 2.1.2 Publication Information 2014 Imagine Communications. Proprietary and Confidential. Imagine Communications considers
JovianDSS Evaluation and Product Training. Presentation updated: October 2015
JovianDSS Evaluation and Product Training JovianDSS High Availability Cluster running in a virtual environment on VMware ESXi Step-by-Step Presentation updated: October 2015 www.open-e.com 1 The aim of
uh6 efolder BDR Guide for Veeam Page 1 of 36
efolder BDR for Veeam Hyper-V Continuity Cloud Guide Setup Continuity Cloud Import Backup Copy Job Restore Your VM uh6 efolder BDR Guide for Veeam Page 1 of 36 INTRODUCTION Thank you for choosing the efolder
Drobo How-To Guide. What You Will Need. Configure Replication for DR Using Double-Take Availability and Drobo iscsi SAN
This document shows you how to use Drobo iscsi SAN storage with Double-Take Availability to deliver replication and DR for servers and applications. Double-Take Availability from Vision Solutions performs
Setting up Citrix XenServer for 2X VirtualDesktopServer Manual
Setting up Citrix XenServer for 2X VirtualDesktopServer Manual URL: www.2x.com E-mail: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples
Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions
HOSTING Administrator Control Panel / Quick Reference Guide Page 1 of 9 Outlook Profile Setup Guide Exchange 2010 Quick Start and Detailed Instructions Exchange 2010 Outlook Profile Setup Page 2 of 9 Exchange
PaperClip. em4 Cloud Client. Setup Guide
PaperClip em4 Cloud Client Setup Guide Copyright Information Copyright 2014, PaperClip Inc. - The PaperClip32 product name and PaperClip Logo are registered trademarks of PaperClip Inc. All brand and product
Using Additional Pollers with WhatsUp Gold v16.0 Learn how to install, configure, and manage pollers for load balancing on your WhatsUp Gold system
Using Additional Pollers with WhatsUp Gold v16.0 Learn how to install, configure, and manage pollers for load balancing on your WhatsUp Gold system Contents CHAPTER 1 Polling Overview WhatsUp Gold Polling
Cloud Attached Storage
Backing Up and Restoring SQL Server Databases Cloud Attached Storage February 2014 Version 4.0 Copyright 2009-2014 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in
Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and 2012. October 2013
Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and 2012 October 2013 This is a publication of Sage Software, Inc. Document version: October 17, 2013 Copyright
Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide
Direct Storage Access Using NetApp SnapDrive Installation & Administration Guide SnapDrive overview... 3 What SnapDrive does... 3 What SnapDrive does not do... 3 Recommendations for using SnapDrive...
Secure Agent Quick Start for Windows
Secure Agent Quick Start for Windows 1993-2015 Informatica Corporation. No part of this document may be reproduced or transmitted in any form, by any means (electronic, photocopying, recording or otherwise)
HyperFS PC Client Tools
SAN Management Software HyperFS PC Client Tools This guide provides step-by-step instructions for setup, configuration, and maintenance of the Rorke Data HyperFS SAN Management Software Ver 2.1 May 11,
WhatsUp Gold v16.2 Installation and Configuration Guide
WhatsUp Gold v16.2 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.2 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines
Drobo How-To Guide. Use a Drobo iscsi Array as a Target for Veeam Backups
This document shows you how to use a Drobo iscsi array with Veeam Backup & Replication version 6.5 in a VMware environment. Veeam provides fast disk-based backup and recovery of virtual machines (VMs),
ECA IIS Instructions. January 2005
ECA IIS Instructions January 2005 THIS PAGE INTENTIONALLY BLANK ECA IIS Instructions ii July 22, 2005 Table of Contents 1. Install Certificate in IIS 5.0... 1 2. Obtain and Install the ECA Root Certificate
Sophos Anti-Virus for NetApp Storage Systems startup guide
Sophos Anti-Virus for NetApp Storage Systems startup guide Runs on Windows 2000 and later Product version: 1 Document date: April 2012 Contents 1 About this guide...3 2 About Sophos Anti-Virus for NetApp
User Guide. CTERA Agent. August 2011 Version 3.0
User Guide CTERA Agent August 2011 Version 3.0 Copyright 2009-2011 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written permission
NETWRIX EVENT LOG MANAGER
NETWRIX EVENT LOG MANAGER ADMINISTRATOR S GUIDE Product Version: 4.0 July/2012. Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment
HP ProLiant DL380 G5 High Availability Storage Server
HP ProLiant DL380 G5 High Availability Storage Server installation instructions *5697-7748* Part number: 5697 7748 First edition: November 2008 Legal and notice information Copyright 1999, 2008 Hewlett-Packard
CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES
CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES TECHNICAL ARTICLE November/2011. Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment
Step-by-Step Setup Guide Wireless File Transmitter FTP Mode
EOS Step-by-Step Setup Guide Wireless File Transmitter FTP Mode Ad Hoc Network Windows 7 2012 Canon U.S.A., Inc. All Rights Reserved. Reproduction in whole or in part without permission is prohibited.
How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade
How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade Executive summary... 2 System requirements... 2 Hardware requirements...
Crystal Reports Developer 11 Installation Guide
Developer 11 Copyright 2007 RiT Technologies. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying,
File Management Utility User Guide
File Management Utility User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held
BIGPOND ONLINE STORAGE USER GUIDE Issue 1.1.0-18 August 2005
BIGPOND ONLINE STORAGE USER GUIDE Issue 1.1.0-18 August 2005 PLEASE NOTE: The contents of this publication, and any associated documentation provided to you, must not be disclosed to any third party without
NETWRIX FILE SERVER CHANGE REPORTER
NETWRIX FILE SERVER CHANGE REPORTER ADMINISTRATOR S GUIDE Product Version: 3.3 April/2012. Legal Notice The information in this publication is furnished for information use only, and does not constitute
Mobility Services Platform 3.1.1 Software Installation Guide
Mobility Services Platform 3.1.1 Software Installation Guide Mobility Services Platform 3.1.1 Software Installation Guide 72E-100159-04 Revision D January 2008 2007 by Motorola, Inc. All rights reserved.
138 Configuration Wizards
9 Configuration Wizards 9.1 Introduction to Wizards ACP ThinManager uses wizards for configuration. Wizards take two forms. List Wizards associate Terminal Servers and ThinManager Servers with their IP
Xopero Backup Build your private cloud backup environment. Getting started
Xopero Backup Build your private cloud backup environment Getting started 07.05.2015 List of contents Introduction... 2 Get Management Center... 2 Setup Xopero to work... 3 Change the admin password...
FTP Server Configuration
FTP Server Configuration For HP customers who need to configure an IIS or FileZilla FTP server before using HP Device Manager Technical white paper 2 Copyright 2012 Hewlett-Packard Development Company,
NSi Mobile Installation Guide. Version 6.2
NSi Mobile Installation Guide Version 6.2 Revision History Version Date 1.0 October 2, 2012 2.0 September 18, 2013 2 CONTENTS TABLE OF CONTENTS PREFACE... 5 Purpose of this Document... 5 Version Compatibility...
13.1 Backup virtual machines running on VMware ESXi / ESX Server
13 Backup / Restore VMware Virtual Machines Tomahawk Pro This chapter describes how to backup and restore virtual machines running on VMware ESX, ESXi Server or VMware Server 2.0. 13.1 Backup virtual machines
DP-313 Wireless Print Server
DP-313 Wireless Print Server Quick Installation Guide TCP/IP Printing (LPR for Windows 95/98/Me/2000) Rev. 03 (August, 2001) Copyright Statement Trademarks Copyright 1997 No part of this publication may
Report Designer and Report Designer Add-In Installation Guide Version 1.0
Table of Contents Report Designer and Report Designer Add-In Installation Guide Version 1.0 Table of Contents The software described in this document is protected by copyright, and may not be copied on
NETWRIX EVENT LOG MANAGER
NETWRIX EVENT LOG MANAGER QUICK-START GUIDE FOR THE ENTERPRISE EDITION Product Version: 4.0 July/2012. Legal Notice The information in this publication is furnished for information use only, and does not
Installation Guide Revision 1.0.
Sage Intelligence Financial Reporting for Sage ERP X3 Installation Guide Revision 1.0. The software described in this document is protected by copyright, And may not be copied on any medium except as specifically
McAfee epolicy Orchestrator 4.5 Cluster Installation Guide
McAfee epolicy Orchestrator 4.5 Cluster Installation Guide COPYRIGHT Copyright 2009 McAfee, Inc. All Rights Reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in
Install MS SQL Server 2012 Express Edition
Install MS SQL Server 2012 Express Edition Sohodox now works with SQL Server Express Edition. Earlier versions of Sohodox created and used a MS Access based database for storing indexing data and other
How to install and use the File Sharing Outlook Plugin
How to install and use the File Sharing Outlook Plugin Thank you for purchasing Green House Data File Sharing. This guide will show you how to install and configure the Outlook Plugin on your desktop.
Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V
Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V How to set up the QNAP Turbo NAS as an iscsi storage for Microsoft Hyper-V and as an ISOs repository Copyright 2010. QNAP Systems, Inc. All
LepideAuditor Suite for File Server. Installation and Configuration Guide
LepideAuditor Suite for File Server Installation and Configuration Guide Table of Contents 1. Introduction... 4 2. Requirements and Prerequisites... 4 2.1 Basic System Requirements... 4 2.2 Supported Servers
Hyper-V Installation Guide for Snare Server
Hyper-V Installation Guide for Snare Server Intersect Alliance International Pty Ltd. All rights reserved worldwide. Intersect Alliance Pty Ltd shall not be liable for errors contained herein or for direct,
Backing up IMail Server using Altaro Backup FS
Backing up IMail Server using Altaro Backup FS Purpose The purpose of this document is to provide guidelines and procedures for backing up IMail server system data and user data in case of a hardware or