Heat Pumps WV SERIES. Features: Left or Right Return Top Discharge

Similar documents
Mechanical Rooftop Custom Capabilities

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Defining Quality. Building Comfort. Heating and Cooling Coils

Installation Manual CLIFC Fan & Coil Variable Speed

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

catalog Single Package Vertical Air Conditioners and Heat Pumps

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Greensource iseries HY Model Unitary Air Handler/Fan Coil

MAC-120HE-01 Air-Cooled Chiller

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

SECTION HEAT PUMPS

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Single Package Vertical Air Conditioners. Vert-I-Pak

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Split System Cooling Product Data

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Nordic Heat Pump Product Guide

Split System Heat Pump Product Data

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Think Green Think Renewable Think

Cased/Uncased Coils For Gas And Oil Furnaces

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Low Profile Unit Cooler

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Geothermal Comfort Systems

CHILLED WATER DATA ROOM UNITS

Split System Cooling Product Data

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

SECTION MORTUARY REFRIGERATORS

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

Bring the fresh in. Dedicated Outside Air Systems

Test Code: 8297 / Version 1

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

TWE+TTA TWE+TWA T.R.


Cooling Capacity CFM in. w.c. (125 Pa)

SECTION AIR CONDITIONING UNIT

ARMSTRONG AIR HEAT PUMPS

Innovent LASER Packaged Fresh Air Conditioning Units

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

CE6500 Energy Recovery Ventilator

Customized Assessment Blueprint

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

Element D Services Heating, Ventilating, and Air Conditioning

Cooling Capacity CFM in. w.c. (125 Pa)

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

Split System Cooling Product Data

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Product Data. Split System Cooling F-EN. March 2015

Dehumidification Frequently Asked Questions

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

Cooling Capacity CFM in. w.c. (125 Pa)

Split System Heat Pump Product Data

Reducing the Cost of Keeping Office Data Centers Cool

IV. Rear Mount System

Energy Efficiency. Energy Efficient Home Cooling:

Cooling/Heat Pump Convertible Air Handlers

Why Daikin? 2015 Houston, Texas USA

ECOCIAT. Domestic hot water heat recovery unit

Miami Heat Pump HP Series Installation Guide

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

F9MXE. Product Specifications

Basics of HVAC Cleaning

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

Local Dealer:

Glossary of Heating, Ventilation and Air Conditioning Terms

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

HP switch LP switch Discharge thermo Comp. Surface thermo

GCS16 GCS20 WARNING CAUTION

How To Save Energy On A Power Supply

Selection Tips For Air-Conditioning Cooling Systems

Product Data. Features/Benefits. AquaForce 30XA Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

Tim Sisson - Trane HVAC OVERVIEW

Chilled Water HVAC Systems

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

RPV - RP - RA air handling units

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

, User s Manual

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

Introduction. Motor Types

CB29M Bulletin # February 1996

Split System Heat Pump Product Data

Commercial Portable Air Conditioners

Commercial Gas Furnace Upflow

Johnson Air-Rotation Systems

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

Topics for Today. Order of Magnitude Mechanical Estimating. Order of Magnitude Estimate Goal. Project Delivery Methods. Questions for Client

Transcription:

Heat Pumps WV SERIES Features: Left or Right Return Top Discharge Fan Motor Reliable Scroll or Rotary Compressors Complete and Easy Service Access with Tool-less Panels Single-Sided Service Access for Easy Maintenance Option Flexibility including Filtration, Hot Gas Reheat Economizer All Aluminum Cabinet with Neoprene Foam Rubber Insulation Aluminum Microchannel Air Coil 5 Year Parts Warranty Designed in Quality Easy Service Access Aluminum Cabinet Construction Replacement Ready Size

WSHP WV series AAON WV Series Horizontal Water-Source Heat Pumps incorporate state-of-the-art manufacturing processes with the latest HVAC design technical knowledge to create a WSHP product with innovative design, performance, and serviceability. The technologically advanced AAON WSHP manufacturing line is unmatched in the industry, utilizing a unique production methodology that integrates mass production with mass customization and allows production of up to 180 units per day. Applications Standard Features R-410A Scroll (2 to 15 tons) or Rotary (½ to 1 ½ tons) Compressors for reliable operation reduced air pressure drop, reduced fan horsepower and reduced unit weight Copper Coaxial Refrigerant-to-Water Heat Exchanger for reliable operation Split Capacitor (PSC) motors or Electronically Commutated Motors (ECM) Direct Drive ECM Driven Backward Curved Plenum Fan is standard on the A and B Cabinets (½ to 1 ½ tons) AAON Pioneer Silver Controller with terminal block for connection to a standard heat pump thermostat containing the following terminals: G = Blower Y = Compressor O = Reversing Valve R = 24V Supply COM = Common Construction Replacement Ready size matches with conventional water-source heat pumps corrosion resistance Hem Bends reduce sharp edges and improve serviceability Left or Right Hand Return Top Discharge Toolless Control Panel Service Access Sloped Stainless Steel Drain Pan includes Automated TIG and Induction Welding Integrated internal condensate P-Trap within the cabinet eliminates need for housekeeping pad Induction Brazed Copper Piping Connections Sellable or Recyclable Sheet Metal Pallet - Standard! 5 Year Parts Warranty - Standard! Factory Installed Options Corrosion Resistant Cupronickel Coaxial Refrigerant-to-Water Heat Exchanger Factory Installed Non-Fused Disconnect Switch Low Sound Package reduce fan and compressor sound One Inch Foil Face Cotton Fiber Cabinet Insulation Factory Provided Return Air Duct Connection Factory Installed Waterside Economizer with Three-Way Motorized Valve Ground/Ground Water Loop Insulation for Geothermal application

H Vertical Configuration Airflow Top Supply Top Supply W SDL SDL W RDW SDW SDW RDW Small Cabinet Sizes allow for a smaller footprint in new construction or replacement applications, such as replacing a vertical stack unit. Smaller footprint saves valuable usable space. RDH RDH H D Left Return Vertical WSHP Service Access D Right Return Vertical WSHP WV Model (MBH) WSHP Cabinet Dimensions Cabinet Width Depth Height Supply Duct Return Duct Water (FPT) Weight (lbs) W L W H In Out WV-006 WV-009 A WV-012 15 19 40 4 11 15 ½ 24 ½ ½ ½ WV-015 B WV-018 WV-024 Vertical ½ ½ C 21 ½ 21 ½ 44 WV-030 ¾ ¾ WV-036 Left or Right D 21 ½ 25 ½ 48 10 ¾ ¾ WV-042 Return 11 ½ 10 ¾ 23 ½ 39 WV-048 ¾ ¾ E Top Discharge 24 29 60 WV-060 1 1 WV-072 F WV-084 WV-120 G WV-144 WV-180 All dimensions are in inches. Dimensions and weight may vary depending on options selected.

Tool-less Control Panel Service Access Access panels do not require tools to open/close. Panels provide service access to the controls, Pioneer Silver Controls Terminal block connections allow connection to a standard heat pump. Internal P-Trap Eliminates the need for housekeeping pads. Standard Two Inch Pleated Filter (2 ton) access from top of the unit for ease of maintenance. Copper Coaxial Refrigerant-to-Water Heat Exchanger Coaxial heat exchanger provides reliable operation. Cupronickel heat exchanger option is available for additional corrosion resistance.

Interior of Supply Fan Section Insulated Service Access Panel (Top Discharge) Direct drive forward curved supply fan is available with Permanent Split Capacitor (PSC) motor or Electronically Commutated Motor (ECM). Neoprene Foam Rubber Cabinet Insulation reduces sound transmission. Interior of Compressor and Refrigeration Components Section Reliable Scroll/Rotary Compressors R-410A scroll compressors are included on units 2 tons and larger. R-410A rotary compressors are included on units from ½ through 1 ½ tons. Compressors are mounted with rubber-in-shear on an isolation plate that is rubber-in-shear isolated in the cabinet for reduced vibration.

Vertical WSHP Performance Data with PSC Motor Fan WV Model (cfm) Fluid Flow (gpm) Voltage Water Loop (Ratings at AHRI Cooling Tower/Boiler Conditions as in accordance with ISO Standard 13256-1) Cooling EWT 86 F Heating EWT 68 F Btu/hr EER Btu/hr COP WV-015 WV-018 WV-024 WV-030 WV-036 WV-042 WV-048 WV-060 WV-072 WV-084 WV-120 WV-144 WV-180 208/230V-60Hz-3ph 460V-60Hz-3ph 208/230V-60Hz-3ph 460V-60Hz-3ph All Aluminum Construction AAON Water-Source Heat Pumps feature all aluminum cabinet conventional water-source heat pump galvanized steel unit. Additional rack that is integrated into the unit cabinet. AAON Metal Pallet AAON designed a custom sheet metal pallet for the AAON Water-Source Heat Pump. The pallet is used to ship and store the units. The metal pallet prevents damage during transit or storage as is common with wood pallets used with conventional water-source heat pump units. Once the equipment is installed at the jobsite the metal pallet can be easily sold or recycled! Microchannel Coils AAON Water-Source Heat Pumps feature an aluminum microchannel indoor DX coil with a larger face area than conventional water-source heat pressure drop, reduce fan horsepower, and reduce unit weight. Replacement Ready AAON Water-Source Heat Pumps will be stocked and ready to ship. Contact your local AAON representative for availability. Replacement units match the size of conventional water-source heat pump units.

WSHP Performance Data with Electronically Commutated Motor Fan WV Model (cfm) Fluid Flow (gpm) Voltage Water Loop (Ratings at AHRI Cooling Tower/Boiler Conditions as in accordance with ISO Standard 13256-1) Cooling EWT 86 F Heating EWT 68 F Btu/hr EER Btu/hr COP WV-006 WV-009 WV-012 WV-015 WV-018 WV-024 115V-60Hz-1ph WV-030 WV-036 WV-042 WV-048 WV-060 WV-072 208/230V-60Hz-3ph 460V-60Hz-3ph WV-084 WV-120 WV-144 WV-180 208/230V-60Hz-3ph 460V-60Hz-3ph Advanced Testing Technology All AAON Water-Source Heat Pump designs are lab tested before going into production. The new AAON Water-Source Heat Pump Laboratory utilizes the most recent advances in HVAC chamber testing technology to allow testing from 20-120 F, 30-80% RH, 147-6,000 cfm, and 1-50 gpm. Unit performance information provided is based on lab testing in accordance with ISO Standard 13256-1. High Tech Water-Source Heat Pump Testing Laboratory

AAON Environmentally Friendly HVAC Product Family ROOFTOP UNITS PACKAGED OUTDOOR MECHANICAL ROOMS (2-240 tons) RZ/RL SERIES RN SERIES RQ SERIES UNITS (4-540 tons) (3-70 tons) SB SERIES OUTDOOR AIR HANDLING UNITS (800-100,000 + cfm) RZ/RL SERIES RN SERIES CONDENSING UNITS (2-230 tons) CB SERIES CF SERIES BOILER MECHANICAL ROOM LF SERIES LN SERIES SA SERIES COILS RQ SERIES CN SERIES FLUID COOLER LZ SERIES BOOSTER, HYDRONIC, & DX CL SERIES F1 SERIES INDOOR AIR HANDLING UNITS (800-100,000 + cfm) V3 SERIES M2 SERIES RQ SERIES (½ - 230 tons) H3 SERIES RZ/RL SERIES RN SERIES SA SERIES M2 SERIES M3 SERIES VERTICAL & HORIZONTAL WSHP M2 SERIES SA SERIES SB SERIES 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com WSHP_WV V89420 170111