traction elevators 2008 planning guide ThyssenKrupp Elevator Americas Business Unit

Similar documents
freight elevators 2008 planning guide ThyssenKrupp Elevator Americas Business Unit

Standard Design TKLP Cab

Roped Hydraulic Residential Elevator Specifications

MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY. KONE EcoSpace

Schindler 5500 Efficiency. Flexibility. Performance.

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

Planning Information. Passenger and Freight Elevators.

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS CENTERFOLD

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

BUILDING PERMIT SPECIFICATIONS

(B613) VERTICAL PLATFORM LIFT PLANNING GUIDE

V1504 Vertical Platform Lift OWNER S MANUAL

P.A.L. S SPECIFICATIONS

S WORK CATALOGUE FAA29100H_BWC

CLEAR-DIVISIONS VARIOFOLD

Automatic Door Selection Guide

Switch. Building technology for the real world.

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

Excellence. in Custom Elevator Cab manufacturing th Ave N Saint Petersburg, FL Ph: Fax:

V1504 Vertical Platform Lift OWNER S MANUAL

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Lift and Escalator Installations

Schindler 3100 Simple and practical. Our passenger elevator for small residential buildings really gets you moving.

ThyssenKrupp Company Name

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

Lödige Goods Passenger Lifts

Machine Room Less (MRL) Elevators. Evolution in elevator design.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Squash Court Design general points

UBC Technical Guidelines Division Edition CONVEYING EQUIPMENT Page 1 of 1 INDEX. Section

Schindler 400AE Machine Room-less Elevator Dynamic. Durable. Distinguished.

Design Development Quality Management Phase Checklist Project Phase Checklist Series

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

DEPARTMENT OF CORRECTIONS

Cooktop Low-Profile Ventilation Hoods

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

HERNANDO COUNTY FIRE ALARM GUIDELINES

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Residential Decks. Planning and Development Services Department

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Expertise in heavy loads. ThyssenKrupp freight elevators.

Carton - Straight Link Machine Chain (Order Unit is Feet )

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Glossary of Common Crane Ter ms:

AUTOMATIC SWINGING DOOR

Building Code Clarifications - 7. Fire Resistance

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

MEASURING AND LEVELING TOOLS

Schindler 3300 AP A remarkable style that suits the building. The machine room-less passenger elevator that unifies form and function.

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Certification: Building Plans Examiner. Exam ID: B3

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

Walking and Working Surface Checklist:

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Mobile Home Pre-Inspection Checklist

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

SECTION MORTUARY REFRIGERATORS

Interfacing Elevators with Fire Alarm and Sprinklers

Hanson Building Products. precast basement solutions

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Gas Meter Clearances and Service Installation Requirements

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Incubator with mechanical convection

CHESTER HOIST LISBON, OHIO, U.S.A PHONE (330) FAX (330)

Now Available in Black Zinc Nickel

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

Miller Engineered Solutions Customized Fall Protection Solutions. NEW! Now featuring Rigid Rail Systems

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

IRRIGATION PUMPING Table of Contents - Section 900

REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

The replacement or modification of existing windows shall comply with the following requirements:

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Gas Meter Clearances and Service Installation Requirements

Fire Alarm System Plans Review Checklist Property location Date of Review

HDA

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Architectural Planning Guide

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Bold items are particular to the City of Euless

BLADE S-MAX Cabinet for Blade Server

Bath Planning Guidelines With Access Standards

SIMULATION PRE-INSTALLATION GUIDELINES CONTRACTOR REQUIREMENTS FOR ROOM PREPARATION

2. What building projects are exempted? (permit not required)

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

MODEL INSTALLATION INSTRUCTIONS

Chapter 5 FLOOR LOADING AND WEIGHTS

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.

Residential Deck Safety, Construction, and Repair

SECTION GROUND WATER STORAGE TANKS

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

Transcription:

traction elevators 2008 planning guide ThyssenKrupp Elevator mericas Business Unit TK

ur ommitment To You esign, Performance, ependability t ThyssenKrupp Elevator, we believe in the critical importance of listening to our customers. While technological expertise makes our products and services possible, we know that listening to our customers is what keeps us at the top of our industry. That s because our commitment to listening leads to the innovations that satisfy our customers needs, driving us continually to set new standards for elevator performance and reliability. Because we always listen to our customers, they have come to regard ThyssenKrupp Elevator as an integral part of their projects. In addition to their confidence in the quality of our products, they know that each of our standard-sized passenger elevators meets the requirements of the mericans with isabilities ct () and that we will modify our elevators to comply with local fire service codes. Perhaps most of all, customers rely on our nationwide network of service locations. nd even if your building is remotely located, no point in the U.S. is more than 75 miles from a ThyssenKrupp Elevator service technician. Table of ontents rchitect irect Pro.......................... 2 SPF Traction Elevators Passenger, with Front penings............... 3 Passenger, with Front and Rear penings....... 4 SPF Traction Elevators For Patient are Facilities.... 5 Gearless Traction Elevators For High-Rise Buildings ustom-engineered Passenger, Up To 700 fpm... 6 ustom-engineered Passenger, Up To 1200 fpm.. 7 ab esign............................. 8-9 TK Entrances etails........................ 10 Work Not Included......................... 11 rchitect irect Pro When you re putting together a proposal, we know you don t have all day to spend on elevator selection. So we ve created a solution that enables you to find the right elevator - and get specifications and drawings - as fast as a few clicks of the mouse. Geared and Gearless Traction Elevators In the field of traction systems, ThyssenKrupp Elevator s designers and engineers push their technological creativity to its full potential. Whether geared or gearless, our traction elevators combine the latest digital technology with world-renowned manufacturing expertise to achieve a new level of precision, energy efficiency, safety and reliability. For buildings of up to twenty-seven floors, ThyssenKrupp Elevator s complete line of SPF geared traction elevators are known for their smooth, quick acceleration, high energy efficiency and competitive pricing. ThyssenKrupp Elevator s gearless systems for high-rise buildings are famous for their versatility, power and, above all, speed. Geared or gearless, all of our traction systems utilize the advanced vector control technology of our all-digital centralized microprocessor control systems to move a lot of people in amazingly little time. This solution is rchitect irect Pro and you ll find it at thyssenkruppelevator.com. ll you have to do is answer a few questions about your building, and rchitect irect Pro will tell you which of our standard elevators is best suited to your project. It s that easy. You ll probably want specifications. With a few more clicks, rchitect irect Pro will compile a complete specifications document ready for download in Microsoft Word. For more information, please contact your local ThyssenKrupp Elevator representative or visit www.thyssenkruppelevator.com. 2

SPF Traction Elevators Passenger Elevators with Front Entrances Safety beam Temperature range 50 F (28 ) min. 90 F (50 ) max. 10-90% Non-ondensing Relative Humidity 7'-6" (2286) S 4" (102) F B E adder to pit 7'-11" (2413) G Travel P S = oncrete structural support slab. Machine room floor to support all elevator machine loads and floor loads per SME 17.1. Right hand door shown: left hand available imensions 1 B 1 2 E 3 F 4 G SPF-21 SPF-25 SPF-30 SPF-35 apacity in pounds 2100 (953 kg) 2500 (1134 kg) 3000 (1361 kg) 3500 (1588 kg) 5-8 (1727) 6-8 (2032) 6-8 (2032) 6-8 (2032) 4-3 (1295) 4-3 (1295) 4-9 (1448) 5-5 (1651) N/ 5 3-6 (1067) 3-6 (1067) 3-6 (1067) 7-4 (2235) 8-4 (2540) 8-4 (2540) 8-4 (2540) 6-8 (2032) 6-8 (2032) 7-2 (2184) 15-0 (4572) 17-0 (5182) 17-0 (5182) 7-10 (2388) 17-0 (5182) 1 lear inside dimensions. 2 Single car dimensions (dd 4 (102) for seismic). 3 dd 2 (51) for seismic. 4 Two car dimensions (dd 8 (203) for seismic). 5 enter opening not available on this model, see G for dimensions. 6 The door sizes shown comply with 2006 IB code requirements. 4000 (1814 kg) 7-8 (2337) 5-5 (1651) 4-0 (1219) 6 9-4 (2845) 7-10 (2388) 19-0 (5791) 3-0 (914) 3-6 (1067) 3-6 (1067) 3-6 (1067) 3-6 (1067) 6 Minimum pit, overhead and machine room dimensions Speed feet per minute (fpm) Geared apacity in lbs. 2100 (953 kg) imensions 200 (1.0m/s) 15-0 (4572) 350 (1.7m/s) 15-0 (4572) 450/500 (2.2/2.5m/s) N/ N/ 2500 (1134 kg) 15-0 (4572) 15-0 (4572) N/ 6-6 (1981) 3000 (1361 kg) 15-0 (4572) 15-8 (4775) 3500 (1588 kg) 15-0 (4572) 15-8 (4775) 6-6 (1981) 17-2 (5232) 6-6 (1981) 4000 (1814 kg) N/ 15-0 (4572) N/ N/ SPF-40 (IB) 7 onsult ThyssenKrupp Elevator for pit with travel over 250-0 (76200). NTE: Hoistway dimensions are based on 1 (25) out of plumb and no occupied space below hoistway. If these conditions cannot be met, then consideration must be given for additional required space. * 5-9 Pit may be required for 2000 code compliance, if 48 retractable toe guard not used. Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details. 3

SPF Traction Elevators Passenger Elevators with Front and Rear Entrances B E ThyssenKrupp Elevator offers a complete line of SPF geared traction elevators that can serve up to 27 landings. ur SPF line offers superb performance in office buildings, apartment complexes, dormitories, hotels and other structures. These elevators offer you standard design data, quick layout and fast delivery. 4" (102) F 8'-9" (2667) Safety beam Temperature range 50 F (28 ) min. 90 F (50 ) max. 10-90% Non- ondensing Relative Humidity SPF-25 SPF-30 SPF-35 S apacity in lbs. 2500 (1134 kg) 3000 (1361 kg) 3500 (1588 kg) imensions Plan 2 Plan 2 Plan 2 1 6-8 (2032) 6-8 (2032) 6-8 (2032) B 1 4-3 1 /2 (1308) 4-9 1 /2 (1461) 5-5 1 /2 (1664) 3-6 (1067) 3-6 (1067) 3-6 (1067) 2 9-2 (2794) 9-2 (2794) 9-2 (2794) E F 3 6-8 3 /4 (2051) 7-2 3 /4 (2203) 7-10 3 /4 (2407) 18-8 (5690) 18-8 (5690) 18-8 (5690) G 3-6 (1067) 3-6 (1067) 3-6 (1067) 7'-11" (2413) 1 lear inside dimensions. 2 Single car dimensions (dd 6 (152) for seismic). 3 Two car dimensions (dd 12 (305) for seismic). NTE: Hoistway dimensions are based on 1 (25) out of plumb and no occupied space below hoistway. If these conditions cannot be met, then consideration must be given for additional required space. Minimum pit, overhead and machine room dimensions Speed feet per minute (fpm) apacity in lbs. 2500 (1134 kg) imensions 200 (1.0m/s) 350 (1.7m/s) 450/500 (2.2/2.5m/s) 15-0 (4572) 15-0 (4572) P 4 6-6 (1981) 3000 (1361 kg) 15-0 (4572) 15-8 (4775) P 4 6-6 (1981) 3500 (1588 kg) 15-0 (4572) 15-8 (4775) 17-2 (5232) P 4 6-6 (1981) 4 6-0 (1829) min. P above 110-0 (33528) travel. onsult ThyssenKrupp Elevator for travel over 250-0 (76200). * 5-9 Pit may be required for 2000 code compliance, if 48 retractable toe guard not used. Travel P adder to pit S = oncrete structural support slab. Machine room floor to support all elevator machine loads and floor loads per SME 17.1. G Right hand door shown: left hand available 4 Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details.

SPF Traction Elevators For Patient-are Facilities E B Plan 1 Plan 2 4" (102) 5 1 /2" (140) B E 5 1 /2" (140) F Two-speed doors - both right and left hand available ur SPF-45, SPF-50 and SPF-50H elevators offer economical, dependable service for hospitals, nursing homes and intermediate care facilities. The car shape makes it ideal for use in any building where the elevator performs a dual role for passengers and service. The SPF-50H is now the standard size hospital car set forth to meet I requirements. SPF-45 SPF-50 SPF-50H apacity in lbs. 4500 (2041 kg) 5000 (2268 kg) 5000 (2268 kg) 6000 (2722 kg) imensions Plan 1 Plan 2 Plan 1 Plan 2 Plan 1 Plan 2 Plan 1 Plan 2 1 B 1 5-8 (1727) 5-8 (1727) 5-8 (1727) 5-8 (1727) 5-8 (1727) 5-8 (1727) 7-9 1 /2 (2375) 7-10 (2388) 8-5 (2565) 8-5 1 /2 (2578) 9-0 (2743) 9-0 1 /2 (2756) 6-0 (1829) 9-5 (2870) 6-0 (1829) 9-5 1 /2 (2883) 2 4-0 (1219) 4-0 (1219) 4-0 (1219) 4-0 (1219) 4-0 (1219) 4-0 (1219) 5-0 (1524) 5-0 (1524) 3 4-6 (1372) 4-6 (1372) 4-6 (1372) 4-6 (1372) 4-6 (1372) 4-6 (1372) N/ N/ 4 8-1 (2464) 8-1 (2464) 8-1 (2464) 8-1 (2464) 8-3 (2515) 8-3 (2515) 8-11 (2718) 8-11 (2718) W S Safety beam Temperature range 50 F (28 ) min. 90 F (50 ) max. 10-90% Non-ondensing Relative Humidity 5 E F 6 F 5 8-3 (2515) 8-3 (2515) 8-3 (2515) 8-3 (2515) 8-3 (2515) 8-3 (2515) N/ 9-8 (2946) 10-9 1 /4 (3283) 10-2 (3099) 11-4 3 /4 (3473) 10-9 (3277) 11-11 3 /4 (3651) 11-2 (3404) 12-4 3 /4 (3778) 16-6 16-6 (5029) 18-2 (5537) (5029) 16-6 (5029) 16-6 (5029) 16-10 (5131) 16-10 (5131) 18-2 (5537) 16-10 (5131) 16-10 (5131) 16-10 (5131) 16-10 (5131) 16-10 (5131) 16-10 (5131) N/ Shaded background indicates pre-engineered models. 1 lear inside dimensions. 2 Standard door width. 3 ptional door width. 4 Single car dimensions (dd for seismic = 4 1 /4 (108) = 3 (76). 5 Required with 4-6 (1372) doors. 6 Two car dimensions (dd for seismic = 8 1 /2 (216) = 6 (152). NTE: Hoistway dimensions are based on 1 (25) out of plumb and no occupied space below hoistway. If these conditions cannot be met, then consideration must be given for additional required space. N/ N/ Minimum pit, overhead and machine room dimensions Speed feet per minute (fpm) 7'-11" (2413) apacity in lbs. 4500 (2041 kg) imensions 200 (1.0m/s) 350 (1.7m/s) 450 (2.2m/s) 19-0 (5791) 19-0 (5791) N/ 15-0 (4572) 8 N/ N/ 5000 (2268 kg) 19-0 (5791) 19-0 (5791) 19-0 (5791) 15-0 (4572) 8 17-8 (5385) 6-6 (1981) 5000H (2268 kg) 19-0 (5791) 19-0 (5791) N/ N/ Travel P adder to pit Rear entrance available 6000 (2722 kg) N/ 15-0 (4572) 8 19-0 (5791) Shaded background indicates pre-engineered models. 19-0 (5791) 20-0 (6096) 17-0 (5182) 7 6-0 (1829) min. P above 110-0 (33528) travel, 200-350 fpm (1.0-1.7 m/s) onsult ThyssenKrupp Elevator for travel over 250-0 (76200). 8 16-0 (4976) above 167-0 (50902) travel. * 5-9 Pit may be required for 2000 code compliance, if 48 retractable toe guard not used. 17-8 (5385) 6-6 (1981) S = oncrete structural support slab. Machine room floor to support all elevator machine loads and floor loads per SME 17.1. W = 7-6 (2286) [8-0 (2438) for 5000 @ 450 and 6000 at all duties]. Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details. 5

Gearless Traction Elevators for 500FPM (2.5 m/s) and 700 FPM (3.6 m/s) ThyssenKrupp Elevator s Gearless traction elevators are the ultimate in high-speed vertical transportation. With vector control technology, our gearless systems precisely control motors at speeds of 500 fpm (2.5 m/s) and 700 fpm (3.6 m/s). B E Safety beam 17'-0" (5182) Temperature range 50 F (28 ) min. 90 F (50 ) max. 10-90% Non-ondensing Relative Humidity 8'-6" (2591) S 4" (102) F 20'-0" (6096) 7'-11" (2413) apacity in pounds imensions 2500 (1135 kg) 3000 (1362 kg) 3500 (1598 kg) 4000 (1816 kg) 1 6-8 (2032) 6-8 (2032) 6-8 (2032) 7-8 (2337) B 1 4-3 (1295) 4-9 (1448) 5-5 (1651) 5-5 (1651) 3-6 (1067) 3-6 (1067) 3-6 (1067) 4-0 (1219) 2 8-4 (2540) 8-4 (2540) 8-4 (2540) 9-4 (2845) E 3 6-8 (2032) 7-2 (2184) 7-10 (2388) 7-10 (2388) F 4 17-0 (5182) 17-0 (5182) 17-0 (5182) 19-0 (5791) 1 lear inside dimensions. 2 Single car dimensions (dd 4 (102) for seismic). 3 dd 2 (51) for seismic. 4 Two car dimensions (dd 8 (203) for seismic). For 500 fpm (2.5 m/s) and 700 fpm (3.6 m/s), chain compensation available up to 300-0 of travel (91440). Rope compensation required above 300-0 of travel (91440). Travel NTE: Hoistway dimensions are based on 1 (25) out of plumb and no occupied space below hoistway. If these conditions cannot be met, then consideration must be given for additional required space. adder to pit 6'-6" (1981)* S = oncrete structural support slab. Machine room floor to support all elevator machine loads and floor loads per SME 17.1. * Pit based on chain compensation. dd 2-8 (813) for rope compensation. 6 Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details.

Gearless Traction Elevators 800 FPM (4.0 m/s) 1000 fpm (5.0 m/s) 1200 fpm (6.1 m/s) Gearless elevators with standard design can travel up to 1200 fpm (6.1 m/s) and are ideal for high-rise buildings of all kinds. These elevators deliver an unbeatable combination of speed, dependability and performance. For special design for speeds up to 1600 fpm (8.1 m/s) contact your local ThyssenKrupp Elevator representative. 9'-8" (2946) S Safety beam by other 18'-0" (5486) Temperature range 50 F (28 ) min. 90 F (50 ) max. 10-90% Non-ondensing Relative Humidity 4" (102) F B E apacity in pounds imensions 3000 (1361 kg) 3500 (1588 kg) 4000 (1814 kg) 1 6-8 (2032) 6-8 (2032) 7-8 (2337) B 1 4-9 (1448) 5-5 (1651) 5-5 (1651) 7'-11" (2413) 2 E 3 F 4 3-6 (1067) 3-6 (1067) 4-0 (1219) 8-4 (2540) 8-4 (2540) 9-4 (2845) 7-2 (2184) 7-10 (2388) 7-10 (2388) 17-0 (5182) 17-0 (5182) 19-0 (5791) 1 lear inside dimensions. 2 Single car dimensions. When speed = 800 fpm (4.0 m/s) add 4 (102) for seismic). When speed = 1000 fpm (5.0 m/s) or 1200 fpm (6.1 m/s) add 2 (51) (3 (76) for seismic). 3 dd 2 (51) for seismic. When speed = 1200 fpm (6.1 m/s) add 4 (102). 4 Two car dimensions. When speed = 800 fpm (4.0 m/s) add 8 (203) for seismic. When speed = 1000 fpm (5.0 m/s) or 1200 fpm (6.1 m/s) add 4 (102) (6 (152) for seismic). Travel Minimum pit, overhead and machine room dimensions Speed feet per minute (fpm) apacity in lbs. 3000 (1361 kg) imensions 800 (4.0m/s) 1000 (5.0m/s) 1200 (6.1m/s) 20-0 (6096) 24-5 (7442) 27-2 (8280) P 11-4 (3454) 11-6 (3505) * 22-6 (6858) 3500/4000 (1588/1814 kg) P 21-8 (6604) 11-4 (3454) 24-8 (7518) 27-2 (8280) 11-6 (3505) * 22-6 (6858) P * adder to pit S = oncrete structural support slab. Machine room floor to support all elevator machine loads and floor loads per SME 17.1. Rope compensation only. NTE: Hoistway dimensions are based on 1 (25) out of plumb and no occupied space below hoistway. If these conditions cannot be met, then consideration must be given for additional required space. * Per SME 17.1 rule 2.2.4.2 must have separate pit access door 10-0 maximum from access door sill to the pit floor or 13-9 maximum from access door sill to pit floor if there is not a building floor below the terminal floor. Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details. 7

ab ptions esign Perfection Standard ab esign s shown below, our standard cab includes laminated plastic walls, a suspended ceiling with baked enamel frame, brushed stainless steel fronts with column type swing return and baked enamel doors. ur new Signa4 signal fixtures are included as the standard in all TKE cabs. oors ur standard door height is 7-0 (2134), but doors can be constructed up to 9-0 (2743). Baked enamel and plastic laminate doors include a kickplate to match fronts. oors have a baked enamel finish from our standard selector; or, provide us a paint sample and we can mix a color to your specifications. Sills Standard esign luminum Upgrade esigns Bronze Finish Nickel Silver enter-opening doors are standard for the 2500, 3000, 3500 and 4000 pound capacity SPF models. Fronts Standard esign Walls Standard esigns aminated Plastic (TKP) Flat Steel Wall (TKS) (not shown) Upgrade esigns Raised pplied Panels (TKP) Single-speed doors are standard for 2100 pound capacity SPF models. olumn Type vailable Finishes: Upgrade esigns Two-speed doors are standard for 4500 and 5000 pound capacity SPF models. 4-6 doors are also available. vailable Styles: Vertical Horizontal vailable Panel Finishes: Plastic aminate vailable Reveal Finishes: Baked Enamel Stainless Steel #4 #8 Upgrade esigns Plastic laminate without binders Plastic laminate with binders Wrap round vailable Finishes: ustom Veneer pplied Panel vailable Panel Finishes: Mahogany Maple Walnut Red ak herry Binders frame your plastic laminate doors. Stainless Steel #4 #8 Full-Width Wrap round vailable Finishes: For more architectural products selections, contact your ThyssenKrupp Elevator sales representative. 8 Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details.

ab ptions esign Perfection eilings ll of our suspended ceilings are mounted 7-4 (2235) above the finished floor. eilings can be raised by extending the cab height. Standard Glassback rrangements Glassback cab options can be incorporated into any standard cab type as a premium option. Standard esign Upgrade esigns Baked enamel suspended frame with white translucent light diffusers. vailable Frame Finishes: Stainless Steel #4 #8 Island Type Halogen ownlight (Wood ore) Plastic aminate Full Height Glass above and below handrail Halogen ownlights Baked Enamel Island Type Perimeter ighting (Wood ore) Plastic aminate bove Handrail Modesty panel below handrail matches wall finish Frame Finish: Baked Enamel Stainless Steel luminum Bronze Miscellaneous Upgrades isc ight vailable Panel and Frame Finishes: Baked Enamel Stainless Steel #4 #8 Incandescent ownlight Baked Enamel Handrails ur handrails provide quality and durability with style and attractiveness. Extended ab (Higher ceilings for transport of tall objects) ontinuous Bar vailable sizes 1/4 (6) wide by: 2 (50) 4 (102) 6 (152) Stainless Steel #4 #8 ylindrical vailable sizes: 1 1/2 (38) diameter 2 (50) diameter Stainless Steel #4 #8 For more architectural products selections, contact your ThyssenKrupp Elevator sales representative. Protection pads for fronts and walls Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details. 9

Passenger Elevator oor ThyssenKrupp Entrance etails Sill Support Supplied by ThyssenKrupp Elevator enter-opening & Single-speed oors Two-speed oors Single-speed oors - lear pening B - Rough pening SPF 2100lb models (ft-in) 3-0 4-3 (mm) 914 1295 SPF 2500, 3000, 3500 (ft-in) 3-6 4-9 and 4000lb models (mm) 1067 1448 enter-opening oors etail 1 (typ.) B etail 1 (typ.) enter-pening oors ll 2500, 3000, and (ft-in) 3-6 4-9 3500lb models (mm) 1067 1448 4000lb models (ft-in) 4-0 5-3 (mm) 1219 1600 Standard Two Speed oors ll 4500, 5000lb (ft-in) 4-0 5-3 and 50H models (mm) 1219 1600 ptional Two-Speed oors (4-6 Wide) ll 4500, 5000lb (ft-in) 4-6 5-9 and 50H models (mm) 1372 1753 Two-speed oors enter-opening & Single-speed oors Two-speed oors B etail 1 (typ.) etail 2 (typ.) Single-speed oors etail 1 (typ.) etail 2 (typ.) Right hand entrance shown. eft hand available where required. rywall onstruction 3 1 /2" (89) Minimum B etail 1 etail 2 2" (51) 2" (51) 3 1 /2" (89) Minimum 8" Pocket 3/4" Finished Sill ine 1/2" oor to Sill 2 3/4" oor 1/4" oor to Frame oor 5" Min. Wall ine "B" + 3 1/2" 2" 7'- 0" Frame pening Minimum Floor to Floor = Frame pening + 1'- 2 1/8" 10 7/16" Pocket 3/4" Finished Sill ine 1/2" oor to Sill 2 3/4" oor 1/4"oor to oor 1 1/4" oor 1/4" oor to Frame oor oor 6 1/2" Min. "B" + 5" Wall ine 7'- 0" Frame pening 2" Minimum Floor to Floor = Frame pening + 1'- 4 1/2" Masonry onstruction etail 1 etail 2 10 Variable 2" (51) 2" (51) Variable Note: Front walls should be left out until entrances are set in place or leave a minimum rough opening that is 15 (381) wider and 15 (381) higher than frame opening of doorway. Note: For openings over 8-0 (2438) consult factory. Note: These diagrams show wall thickness and construction detail required in order to supply a minimum 1 1/2 HR. Warnock Hersey abel on entrances. ontact your local ThyssenKrupp Elevator representative for additional details. Note: ll dimensions in parentheses are in millimeters unless otherwise indicated. imensional data shown here complies with the current SME 17.1 and S B44 Safety ode for Elevators. ocal codes may vary from the national codes. onsult your local ThyssenKrupp Elevator representative for details.

Work By thers Work Not Included in the Elevator ontract* The following preparatory work is required in order to properly install the elevator equipment. The cost of this work is not included in the elevator proposal, since it is a part of the building construction. 1. plumb and legal hoistway, properly framed and enclosed and including a pit of proper depth, and a pit ladder for each elevator. rains, lights, access doors, waterproofing and hoistway ventilation, as required. 2. Enclosed elevator equipment room with electrical work outlets, adequate lighting, and heating and ventilation sufficient to maintain the room at a temperature of 50 F minimum to 100 F maximum. 3. dequate supports and foundations to carry the loads of all equipment, including supports for guide rail brackets. 4. omplete connections from the electric power mains to each controller, including necessary circuit breakers and fused mainline disconnect switches. 5. Electric power of the same characteristics as the permanent supply without charge for the construction, testing and adjusting. 6. Proper trenching and backfilling for any underground piping or conduit. 7. ivider beams for rail brackets support as required. 8. utting of walls, floor, etc. and removal of such obstructions as may be necessary for proper installation of the elevator. 9. Grouting of door sills, hoistway frames, and signal fixtures after installation of the elevator equipment. 10. ll painting, except as otherwise specified. 11. Temporary enclosures, barricades, or other protection from open hoistways and elevator work area during the time the elevator is being installed. 12. Temporary elevator service prior to completion and acceptance of complete installation. 13. Smoke sensors as required in accordance with NFP**#72E and SME 17.1.*** 14. ll telephone wiring to machine room control panel, and installation of telephone instrument or other communication equipment in elevator cab with all connections to elevator traveling cable and in machine room. 15. standby power source, including necessary transfer switches and auxiliary contact, where elevator operation from an alternate power supply is required. 16. dequate storage facilities for elevator equipment prior to and during installation. 17. means to automatically disconnect the main line power supply to the elevator prior to the application of water in the elevator machine room will be furnished by the electrical contractor. This means shall not be self-resetting. 18. Setting of anchors and sleeves. *Refer to elevator layout drawings for details of each requirement. **National Fire Protection ode ***Safety ode for Elevators and Escalators 11

version 07.08 ll illustrations and specifications are based on information in effect at time of publication approval. ThyssenKrupp Elevator reserves the right to change specifications or design and to discontinue items without prior notice or obligation. opyright 2008 ThyssenKrupp Elevator orporation ThyssenKrupp Elevator P.. Box 2177 Memphis, TN 38101 Tel: 877-230-0303 (Toll Free) thyssenkruppelevator.com TKE 0066 v07.08 25M 0708 GSI Printed in U.S..