Triple Expansion Chassis



Similar documents
Out-of-Band Management Card

BroadBand PowerShield. User Manual

APC Step-Down Transformer. User s Manual

Metered Rack Power Distribution Unit

Network Management Card. Installation and Quick Start Manual

Installation Guide Smart-UPS X External Battery Pack SMX120BP

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

How To Install A Power Supply (Uplast) With A Battery Pack

Installation and Quick Configuration

Unpacking, Installation, and Customization

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

About the HotWire Slot Standalone Shelf

Messager USB Digital Messaging System

About Your NetBotz 4-20mA Sensor Pod

AXIS 291 1U Video Server Rack Installation Guide

Installation. Basic Rack Power Distribution Unit AP9559

USB 3.0 to M.2 NGFF SSD Enclosure with UASP

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

P73474-F5U006-UNV-AM-man.qxd 9/18/00 10:10 AM Page 1

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

Dual-Cool Notebook Cooler Pad. User s Manual

Installation & User Manual

USB Port Hub with USB Power Cable. User s Manual

Alarm Clock USER GUIDE

Advantium 2 Plus Alarm

Optical Wireless Mouse. User s Manual

4 Port PCI Express Gigabit Ethernet PoE PSE Network Card

Network Management Card

APC IP KVM QuickStart Guide

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

Universal Laptop Charger

Wireless Keyboard and Optical Mouse Bundle

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

ATA User Manual. iinet ATA Telephone Adapter. Setting up for ADSL and VoIP. For model F1PG200ENau

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

MACTek Corporation. USB HART Interface. Users Manual

HDMI or Component Standalone Capture Device 1080p

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

M.2 NGFF SSD to 2.5in SATA Adapter

750VA/1000VA/1500VA 100/120/230VAC 2U

Installation Manual. NetBotz Room Sensor Pod 155 NBPD0155

USB to RS232 Adapter User s Manual

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

HP UPS R1500 Generation 3

HLWLAN b/g/n Transceiver Kit

TTL to RS232 Adapter User Guide

Serial ATA Hard Drive Docking Station

Wireless Indoor/ Outdoor Thermometer

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

READ FIRST! Universal Car/Air Adapter User Manual

Laser Wireless Rechargeable Mouse. User s Manual

LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

USB Peripheral Switch Share a USB device with up to four computers

UIM-2T1 T1 Loop Bonding Uplink Interface Module

PIR-1 Owner s Manual

USB Rover port USB m Cat 5 Extender. User Guide

ARCHOS (

Energy Smart Electric Water Heater Controller

Wireless Optical Travel Mouse

Mini Speaker. Printed in China Part No P Version D. CWA BT300 Product Information Guide

AastraLink RP 500. Installation Guide Rev 03

MCR1900 Media Converter 19-Slot Chassis

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

GSM-EXT Cable Assembly Installation Guide

Gateway Port Replicator User Guide

USER MANUAL. Kramer Electronics, Ltd. Models:

KVM Switch P74242-D. Belkin B.V. Boeing Avenue PH Schiphol-Rijk, The Netherlands +31 (0) (0) fax. Belkin Ltd.

About the BitStorm 6051 POTS Splitter

AXIS T81B22 DC 30W Midspan

Network Management Card

External Desktop. HP SimpleSave. Desktop Hard Drive User Manual. SimpleSave

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

VGA to HDMI video converter with scaler

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

WAVE BLUETOOTH MUSIC ADAPTER

Usage, Installation, Warranty and Service Information

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

How To Set Up An Ecm Display On A D210 (D210) (D2) (Ecm) (Emc) (Mcd) (Power Supply) (Mm) (Camellom) (Ios)

User Manual. English. APC Smart-UPS RT. 3000/5000/6000 VA VAC Tower/Rack Mount 3U Uninterruptible Power Supply

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System


Architect/Contractor Information Package

USB 3.0 SATA/IDE 2.5 Hard Drive Enclosure

safe, smart, protected

User Manual. English. APC Smart-UPS VA 120/230 Vac VA 100/120/208/230 Vac. 2U Rack Mount Uninterruptible Power Supply

MasterSwitch. Power Distribution Unit. User s Guide AP9211 AP9212

Intelli-Time Alarm Clock model 13027

Avaya 1100 Series Expansion Module User Guide. Avaya Business Communications Manager

Zebra RW 420 Mobile Battery Eliminator Kits

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Removable 2.5 SATA HDD Backup System

Dolphin 9900 Mobile Computers

User Manual. Smart-UPS TM C. Uninterruptible Power Supply SRC250 SRC /120/230 Vac. Tower/Rack-Mount 1U

Transcription:

Triple Expansion Chassis AP9604 Installation Manual

Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations.............................. 6 Specifications............................ 7 Warranty and Service...................... 8 Life-Support Policy....................... 10

Introduction The APC Triple Expansion Chassis is a 3-slot chassis designed to accommodate APC management cards. The Triple Chassis allows you to: Use cards with APC UPSs that are not equipped with a card slot but do have an advanced Computer Interface Port Add cards to UPSs that have an existing card slot Use cards such as the Environmental Monitoring Card in a stand-alone configuration Hardware Three card slots 9-pin male port for connecting the Triple Chassis to the computer interface port of the UPS Power input connector for optional power adapter 9-pin female UPS monitoring port that duplicates the functions of the computer interface port on the UPS Status indicator (LED) Mounting enclosure hardware Introduction 1

Installation The Triple Chassis can connect to any APC device equipped with an advanced type computer interface port. This includes certain Smart-UPS and Matrix-UPS products, and any other management card that duplicates the functions of the UPSs computer interface port, such as the Share-UPS. Configurations Stand-alone desktop unit Mounted in a NetShelter (EIA-310-D) 19-inch enclosure Desktop installation The Triple Chassis is equipped with rubber feet for desktop use and can be set up wherever space permits. 1. Place the Triple Chassis in its permanent location. It should be located within 10 ft. (3.3 m) of the UPS. Make sure that the front of the unit is accessible. 2. Connect the female end of the cable (940-1000A) to the 9-pin male connector labeled To UPS on the front of the Triple Chassis. 3. Connect the male end of the cable to the 9-pin female Computer Interface Port on the rear of the UPS. 4. If UPS monitoring is to be used, connect the required cable (940-0024, not supplied) from the 9-pin monitoring port on the front of the Triple Chassis to an appropriate serial port on your computer, or to another card. 5. If additional power is needed (see "Power Considerations" on page 5), connect the optional power adapter output to the front of the Triple Chassis. 2 Installation

Rackmount installation The Triple Chassis is designed to mount in a NetShelter enclosure (or other 19-inch EIA-310-D) using the hardware included with the Triple Chassis. The Triple Chassis can be installed in the enclosure by following these steps: 1. Peel the rubber feet from the bottom of the Triple Chassis. 2. Attach a mounting bracket to each side of the Triple Chassis using 2 small flat-head screws (supplied) and a #2 Phillips screwdriver. Installation 3

The mounting brackets can be attached at various positions along the side of the Triple Chassis using the holes provided. Choose a position that will not cause the mounted Triple Chassis or the attached cables to interfere with closing the cabinet door or to otherwise protrude from the cabinet. If more than two mounting holes are aligned, choose the pair that are farthest apart. 3. Mount the Triple Chassis into the NetShelter enclosure with 4 caged nuts and machine screws (not supplied). If the Triple Chassis is being installed in a enclosure other than a NetShelter, use the hardware that is appropriate for the enclosure. 4 Installation 4. Connect the female end of the included cable to the 9- pin male connector labeled To UPS on the front of the Triple Chassis. 5. Connect the male end of the cable to the 9-pin female computer interface port on the rear of the UPS. 6. If UPS monitoring is to be used, connect the required cable (940-0024, not supplied) from the 9-pin monitoring port on the front of the Triple Chassis to an appropriate serial port on a computer, or to another card. 7. If additional power is needed (see "Power Considerations" on page 5), connect the optional power adapter output to the power port on the front of the Triple Chassis.

Power Considerations The power required for the operation of the card is normally provided to the Triple Chassis by the UPS. There is a limit to the amount of power available, and the total power required by all the cards installed in the Triple Chassis must not exceed this limit. If this limit is exceeded, it is likely that the management product will cease to operate properly. The limits are: Smart-UPS 200 ma Matrix-UPS 200 ma To determine the total amount of power required, add the individual power requirements for each of the management products to be installed in the Triple Chassis, as well as the power requirements for the Triple Chassis itself. The power requirements for each individual card can be obtained from the documentation included with that card. Optional power adapter In cases where the power requirements exceed 200 ma, APC s optional 24VDC (AP9505, not supplied) adapter may be used to supplement the UPS power by providing an additional 400 ma. The power adapter is also required under the following conditions: Smart-UPS models: Serial number prior to S9405 Serial number starting with the letter W All Smart-UPS 250 models Matrix-UPS models: When remote turn-on of the UPS is required The optional power adapter is used with 100/120 VAC power only. AP9505I is also available for universal power input, but requires a customer-supplied line cord. If you need to obtain a power adapter, contact APC Customer Service at a telephone number on the back cover. Power Considerations 5

Operations Status indicator The Triple Chassis status LED indicates the following states: State Bright Dim Off Indication The Triple Chassis has power and at least one management card is installed. The Triple Chassis has power and no management card is installed. The Triple Chassis has no power. Checking operation 1. After installing the Triple Chassis and before installing the card, confirm that the indicator light is dimly lit. 2. After installation of the card confirm that the indicator light is brightly lit. 3. Confirm the operation of the card. Refer to the documentation that was included with the card for the proper checking procedure. 4. Confirm that previous installed cards and software continue to operate. 6 Operations

Specifications Item Specification Electrical Operating voltage: Operating current draw: 18 30 V 30 ma (exclusive of installed card) Physical Size (H W D): Weight: Shipping weight: For desktop installation, with rubber feet: 2.13 17 6.5 in 5.4 43.18 16.51 cm For rack-mount installation, with mounting brackets: 1.75 17 6.5 in 4.4 43.18 16.51 cm 1.5 lb 0.7 kg 2 lb 0.9 kg Environmental Operating elevation (storage): Operating temperature (storage): 0 to 1000 ft (0 to 50 000 ft) 0 to 3000 m (0 to 15 000 m) 5 to 45 C ( 25 to 65 C) 23 to 113 F ( 13 to 149 F) Approvals EMC verification: Electromagnetic immunity: FCC Class A, DoC Class A, EN55022 Class A, VCCI, AS/NZS 3548 EN50024 verified Specifications 7

Warranty and Service Limited warranty APC warrants the Triple Expansion Chassis to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. Warranty limitations Except as provided herein, APC makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary according to jurisdiction. 8 Warranty and Service

Obtaining service To obtain support for problems with your Triple Expansion Chassis: 0 1. Note the serial number and date of purchase. 2. Contact Customer Support at a phone number on the back cover of this document. A technician will try to help you solve the problem by phone. 3. If you must return the product, the technician will give you a return material authorization (RMA) number. If the warranty expired, you will be charged for repair or replacement. 4. Pack the unit carefully. The warranty does not cover damage sustained in transit. Enclose a letter with your name, address, RMA number and daytime phone number; a copy of the sales receipt; and a check as payment, if applicable. 5. Mark the RMA number clearly on the outside of the shipping carton. 6. Ship by insured, prepaid carrier to the address provided by the Customer Support technician. Warranty and Service 9

Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: In life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to affect significantly its safety or effectiveness. In direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances. Examples of life-support devices The term life-support device includes but is not limited to neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators (for adults and infants), anesthesia ventilators, infusion pumps, and any other devices designated as critical by the U.S. FDA. Hospital-grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems. APC does not claim that units with this modifications are certified or listed as hospital-grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care. 10 Life-Support Policy

Radio Frequency Interference Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate this Warning equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference. The user will bear sole responsibility for correcting such interference. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC Knowledge Base, and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support with FAQs, knowledge base, and e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers: APC Headquarters U.S.&Canada Latin America Europe, Middle East, Africa (1) (800) 800-4272 (toll free) (1) (401) 789-5735 (USA) (353) (91) 702020 (Ireland) Japan (03) 5434-2021 Guidance 3 Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2002 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, Share-UPS, Matrix-UPS, NetShelter, and the APC logo are trademarks of American Power Conversion Corporation and may be registered in some jurisdictions. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-0145C 01/2002