How to Test a Combi Control Unit



Similar documents
KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS , identification se table of results.

Home Monitoring and Control service provided by Verizon Online LLC

AirPatrol WiFi Full Manual V1.0

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

IntesisBox KNX LG Air Conditioning

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

Uponor Smatrix Wave PLUS R-167 INSTALLATION AND OPERATION MANUAL HELP AND TUTORIAL

T-100-R Installation Guide

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Passion for Innovation

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Welcome to Bell Aliant NextGen Home Security

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

User's Guide. [Home Network] app. Model No.


SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

PRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a

site monitoring Kit Site Monitoring Kit User Manual we prove it.

User Manual. NETGEAR, Inc. 350 East Plumeria Drive San Jose, CA 95134, USA. December

REMOTE CONTROL MANUAL

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

GSM Home Alarm System User Manual.

Controller Automation, Model II+

Safe Health Guarder User Manual

HVAC Processes. Lecture 7

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

2.1 The performance of bus air conditioning system is evaluated in the following operating conditions

Inwall Room Temperature Unit

Solar Powered Outdoor Siren Manual

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Data Logger Basics For VFC Providers. Montana Immunization Program

Single Zone LCD Thermostat Operating Instructions

Professional Contractor INSTALLATION GUIDE

Bright House Networks Home Security and Automation Mobile Application. Quick Start Guide

Installation Guide for Hive Active Heating

Bright House Networks Home Security and Control Mobile Application

Quick Start Guide. Indoor. Your unique camera ID is:

Copyrights 2010 Victron Energy B.V. All Rights Reserved

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Schedule 3(A) Room Air Conditioners

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Table of Contents. 3 Setup 6 Home Screen 8 Modes 12 Watch Live & Timeline 17 HomeHealth Technology 21 Emergency Options 24 Settings 26 Plans 28 Help

User Guide Reflow Toaster Oven Controller

Additional Instruction

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

PSTN Home Alarm System

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

User Guide. A clever person solves a problem. A wise person avoids it. - Albert Einstein

User's Guide. Pinless Moisture Meter. Model MO257

CIPCAM720PTIWL,CIPCAM720OD,CIPCAM720ODWDR,CIPDC AM720OD

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Quick Start Guide For Vera Small Business Solution

Modbus Server SAMSUNG Air Conditioners

User Manual GSM Alarm System. All rights reserved by Delta Security Co., Ltd

CGC s Hybrid System Loop Control

Indoor Remote Controlled Power Points

EM8610 e-alarm GSM Alarm System Starter Kit

GSM Smart Switch USER GUIDE

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

it500 Internet Thermostat INSTALLER MANUAL

F453. TiF453. User guide 10/11-01 PC

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

INSTALLATION GUIDE 1

KNX Panasonic Air Conditioners

Rogers Smart Home Monitoring QUICK START GUIDE ROG_6093_QST_GDE_EN.indd 1 9/22/12 8:29 AM

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

Apps for Android. Apps for iphone & ipad INS584-3

TMS TANK MANAGEMENT SYSTEM

CCTR-800 Portable Real Time GPS Tracker

Installation Guide. Mobile Surveillance Distance makes no difference. eagleeyes_quick_v1.5

RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! RadioRA2 Inclusive Software v5.0.8 or newer

User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

GSM-DIN3. GSM Communicator. Instructions: January 5, 2013, refers to the firmware version: 1.014

IntesisBox KNX Mitsubishi Heavy Industries AC

SMM. Installation Operation Maintenance

CCTR-805-V2 3G Car GPS Tracker

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Transcription:

Contact person Enar Andersson 2013-06-11 3P03701 1 (22) Energy Technology +46 10 516 59 56 enar.andersson@sp.se Innovate Solutions oü Sihi 42 Tallin Estonia 116 22 Testing of Air Patrol Heat Pump Controller Assignment SP has performed testing of an Air Patrol Heat Pump Controller Combi Control as an assignment from Innovate Solutions oü. The Air Patrol Heat Pump Controller Combi Control is a product making it possible to control and supervise an air to air heat pump using a mobile phone. The tested product was a version of the Air Patrol Heat Pump Controller called Combi Control, which is in general the same product as the Air Patrol Heat Pump Controller. The difference is that the Combi Control is designed to work specifically with Toshiba heat pumps. Therefore, the air to air heat pump which was used when testing the Combi Control unit was a Toshiba. The testing was performed with the heat pump s indoor unit placed in a calibrated calorimeter chamber and the outdoor unit placed in a climate chamber. The Combi Control was mounted and tested in the calibrated calorimeter chamber. Object tested Combi Control, unit with serial number C1109102326250489. Time and place for the testing The testing was performed at SP, Energy Technology, the 6 th of May 2013. Date of arrival of equipment The equipment to be tested was delivered to SP on the 3 rd of May 2013. Method of testing The testing was performed with the outdoor part of the heat pump placed in a climate controlled chamber with a stabilized measured dry bulb temperature of 7.1 C and a calculated wet bulb temperature of 6.0 C. The climate was constant during the test and continuously regulated. The indoor part of the heat pump was placed in a calibrated calorimeter chamber with varying temperature. During one part of the test the heat pump was tetsed at 100 % of the unit s maximum capacity, the temperature setting on the remote controller is set to maximum and the derired temperature is obtained by regulating the cooling load of the calorimeter room. During another part of the test the unit was tested by changing the temperature setting on the remote Postal address Office location Phone / Fax / E-mail This document may not be reproduced other than in full, except with the SP Box 857 SE-501 15 BORÅS Sweden Västeråsen Brinellgatan 4 SE-504 62 BORÅS +46 10 516 50 00 +46 33 13 55 02 info@sp.se prior written approval of SP.

2013-06-11 3P03701 2 (22) controller to different valules, thus resulting in testing the unit at heating capacity less than the unit s maximum capacity. The Combi Control unit was placed in the calorimeter chamber in various positions (both positions in accordance to the user guide and positions not following the instructions in the user guide) and the heat pump was supervised as it reacted to the Combi Control s controlling commands. The Combi Control app was installed on a mobile phone using Android. Direct commands to the Combi Control unit was sent both from an Android mobile phone as well as an ios mobile phone. Installation and configuration The installation of the SIM-card and installation of the app on the Android mobile phone was performed by following the instructions in the Quick start guide, found here: http://combicontrol.net/wp-content/uploads/2012/05/combi-quick-setup.pdf The Combi Control app version used was 1.0.33. The app was downloaded on the 6 th of May 2013. The operation of the app and SMS-commands was performed in accordance to descriptions in the user manual, found here: http://combicontrol.net/wp-content/uploads/2012/05/cc_manual_web_eng_fin_swe_nok_4.pdf Equipment Calorimeter chamber, LL1 Outdoor climate chamber, LV2 Electrical power meters, Inv. Nr. 200452, 200453, 202655 Data logging equipment, Inv. Nr. 201553, 202681 Air temperature sensors, Pt 100 and thermocouple Heat pump, Toshiba. Indoor unit model no.: RAS-25N3KVP-ND. Outdoor unit model no.: RAS-25N3AVP-ND Mobile phone HTC One S Mobile phone iphone 4 Uncertainty of measurement The results from the test are based on measurements. The total uncertainty of measurement of the results in the report has been calculated in accordance with the following estimates of uncertainties of measurement and calculation. The estimates are those of the total uncertainties, including both systematic and random uncertainties. Temperatures, test points Tvbin_m Thermocouple ± 0.2 K ± 1.0 K Other quantities P Evpa ± 0,5 %

2013-06-11 3P03701 3 (22) Settings The Combi Control unit tested was given the name Lab1 in the app by the user at configuration. The version and other information obtained from the version information request sent from the app to the Combi Control unit are shown below. Figure 1: Screenshot of the app showing version information and operating status for the Combi Control unit General settings The heat pump model was set to a general Toshiba heat pump. The owner number was set to the number to the phone using the app, i.e. the Android phone. The settings are shown below. Figure 2: Screenshot of the app showing the basic settings for the Combi Control unit

2013-06-11 3P03701 4 (22) Test proceeding The test object was installed to a wall plug for battery charging at 14:00 the 4 th of May. The charging was stopped at 06:00 the 6 th of May as the equipment then was unplugged from the power supply. At this time the unit was turned off by pushing the reset button one time. The unit was turned off during transport to the laboratory. The equipment was again connected to a wall plug as it arrived to the laboratory. The Combi Control unit to be tested was again switched on as it was connected to a wall plug. 08:10 The climate chamber and calorimeter chamber were started. The initial testing procedure was performed by regulating the cooling load of the calorimeter room to achieve a temperature to the heat pump s air intake, of 20 C. The heat pump is operating at its maximum heating capacity at an outdoor air temperature (wet bulb air temperature) of +7(6) C. 10:55 The temperature state in the outdoor climate chamber was stabilized and the heat pump was running on maximum power with a an ingoing temperature to the heat pump s indoor unit of 20 C. In the diagrams shown in this report the the electrical power input to the heat pump is shown as Pevpa and the ingoing temperature to the heat pump s indoor unit is shown as Tvbin_m. The Tvbin_m is the calculated mean value from 4 temperature sensors placed at the indoor unit s air intake side. In this report, when referring to the ingoing temperature to the heat pump s indoor unit, the Tvbin_m variable is being referred to. 10:57 The Combi Control unit was installed in the indoor calorimeter chamber and the self-test was ran by pushing the Test button on the Combi Control. When the Test button was pushed, the heat pump stopped. The Combi Control was installed beside the heat pump according to the user guide, see next page. A thermocouple was placed close to the temperature sensor on the Climate Control unit, providing appsoximate temperature readings.the thermocouple is shown in the images on the next page and marked by a green circle in Figure 6.

2013-06-11 3P03701 5 (22) Figure 3: Image showing the positioning of the Combi Control unit. Figure 4: Image showing the positioning of the Combi Control unit. Figure 5: Image showing the positioning of the Combi Control unit with the thermocouple marked in the green circle.

2013-06-11 3P03701 6 (22) 11:00 With the heat pump stopped, the following command was sent to the Combi Control unit from the Combi Control app: Power on, mode auto, fan speed auto, setpoint 30 C. The heat pump started. 11:15 The following command was sent to the Combi Control unit from the Combi Control app: Power on, mode auto, fan speed max, setpoint 30 C. The status update which was automatically received is shown below. Figure 6: Screenshot of the app showing the new settings sent to the Combi Control unit. The temperature at the thermocouple at this time was 19.6 C. The ingoing temperature to the heat pump s indoor unit at this time was 19.0 C. Status requests were sent by SMS to the Combi Control unit from the owner phone. None of these request resulted in a status report. Status requests were sent by SMS from a phone other than the owner phone. These requests all resulted in status reports to the phone from which the requests were sent. 11:16 The heat pump started. 11:41 The power supply to the Combi Control unit was disconnected. The unit now ran on battery. The alarm time for missing power supply to the Combi Control unit was set to 1h from the app.

2013-06-11 3P03701 7 (22) 11:42 The testing procedure is changed so that the regulation of the cooling load of the calorimeter room is fixed. The indoor air temperature will now be regulated by the heat pump and its control system 12:00 An alarm message was received from the CombiControl unit regarding missing power supply, see below. Figure 7: Screenshot of the app showing the alarm message from the Combi Control unit. A status update request was also sent from the app to the Combi Control unit. The received status is shown below. Figure 8: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 22.7 C. The ingoing temperature to the heat pump s indoor unit at this time was 22.4 C.

2013-06-11 3P03701 8 (22) 12:32 A second alarm message is received from the CombiControl unit regarding missing power supply, see below. 12:34 Figure 9: Screenshot of the app showing the alarm message from the Combi Control unit. A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 10: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 23.7 C. The ingoing temperature to the heat pump s indoor unit at this time was 22.9 C.

2013-06-11 3P03701 9 (22) 12:46 A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 11: Screenshot of the app showing the status report from the Combi Control unit The temperature at the thermocouple at this time was 23.6 C. The ingoing temperature to the heat pump s indoor unit at this time was 23.0 C. 12:51 The power supply was again connected to the Combi Control unit. A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 12: Screenshot of the app showing the status report from the Combi Control unit The temperature at the thermocouple at this time was 23.3 C. The ingoing temperature to the heat pump s indoor unit at this time was 23.0 C.

2013-06-11 3P03701 10 (22) 12:55 A new favorite with the current settings was created in the app by pushing the heart button in the app. Also, A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 13: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 23.7 C. The ingoing temperature to the heat pump s indoor unit at this time was 23.0 C. 13:07 A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 14: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 23.5 C. The ingoing temperature to the heat pump s indoor unit at this time was 23.0 C.

2013-06-11 3P03701 11 (22) The diagram below shows the electrical power input to the heat pump and the temperature in the chamber between 11:15 and 13:07 i.e. the time when the command representing the 30 C Max Auto favourite was active. 2200 24 2180 2160 23 2140 2120 22 Q [W] 2100 2080 2060 21 20 T [ C] Pevpa Tvbin_m 2040 2020 19 2000 172,8 192,8 212,8 232,8 252,8 272,8 Mättid [min] 18 Figure 15: Diagram showing power and temperature.

2013-06-11 3P03701 12 (22) 13:08 By sending the following command via SMS, new setpoints, were sent to the Combi Control unit from the iphone (i.e. not the phone with the app installed): Power on, mode auto, fan speed max, setpoint 22 C. A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 16: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 23.7 C. The ingoing temperature to the heat pump s indoor unit at this time was 23.4 C. 13:19 A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 17: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 19.3 C. The ingoing temperature to the heat pump s indoor unit at this time was 18.4 C.

2013-06-11 3P03701 13 (22) 13:30 A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 18: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 19. 7 C. The ingoing temperature to the heat pump s indoor unit at this time was 18.9 C. 13:34 A power off (stop) command was sent to from the app to the Combi Control. The heat pump stops. The status update which was automatically received is shown below. Figure 19: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 20.8 C. The ingoing temperature to the heat pump s indoor unit at this time was 20.1 C.

2013-06-11 3P03701 14 (22) 13:37 The following commands were sent to the Combi Control unit from the app: Power on, mode auto, fan speed auto, setpoint 18 C. The status update which was automatically received is shown below. Figure 20: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 20.7 C. The ingoing temperature to the heat pump s indoor unit at this time was 20.5 C. 13:45 A version information request was sent to the Combi Control unit from the app. The received message is shown below. Figure 21: Screenshot of the app showing the status report from the Combi Control unit.

2013-06-11 3P03701 15 (22) 13:47 A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 22: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 13.9 C. The ingoing temperature to the heat pump s indoor unit at this time was 14.2 C. 14:06 The calorimeter chamber was opened and by operating the remote control for the heat pump a setpoint of 18 C and auto fan speed was set. The calorimeter chamber was closed. 14:13 The calorimeter chamber is opened and by operating the remote control for the heat pump a setpoint of 20 C and max fan speed is set. The calorimeter chamber is closed.

2013-06-11 3P03701 16 (22) 14:20 A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 23: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 15.0 C. The ingoing temperature to the heat pump s indoor unit at this time was 14.6 C. 14:28 A status update request was sent from the app to the Combi Control unit. The received status is shown below. Figure 24: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 18.7 C. The ingoing temperature to the heat pump s indoor unit at this time was 18.5 C.

2013-06-11 3P03701 17 (22) 14:52 The following commands were sent to the Combi Control unit from the app: Power on, mode auto, fan speed max, setpoint 30 C. The status update which was automatically received is shown below. Figure 25: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 18.1 C. The ingoing temperature to the heat pump s indoor unit at this time was 18.1 C. 14:59 A power off command was sent to the Combi Control unit from the app. The status update which was automatically received is shown below. Figure 26: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 20.0 C. The ingoing temperature to the heat pump s indoor unit at this time was 19.8 C.

2013-06-11 3P03701 18 (22) 15:03 The placement of the Combi Control unit was changed to a position opposite to the indoor part of the heat pump. The command power on was sent from the app to the Combi Control. The pump started. The status update which was automatically received is shown below. Figure 27: Screenshot of the app showing the status report from the Combi Control unit. The temperature at the thermocouple at this time was 20.8 C. The ingoing temperature to the heat pump s indoor unit at this time was 20.3 C. 15:06 The placement of the Combi Control unit was changed to a position in the ceiling in the chamber. The command power off was sent from the app to the Combi Control. The pump stops. 15:07 The placement of the Combi Control unit was changed to a position where the unit was placed on the floor with one IR-transmitter facing down toward the floor in the chamber. The placement is shown below.

2013-06-11 3P03701 19 (22) Figure 28: Image showing the positioning of the Combi Control unit with the unit marked in the green circle. The indoor part of the heat pump is shown to the left in the image. The command power on was sent from the app to the Combi Control three times. There was no reaction from the heat pump. 15:08 The placement of the Combi Control unit was changed to a position where the unit was placed on the floor in the chamber with the IR-transmitter facing up. The placement is shown below. Figure 29: Image showing the positioning of the Combi Control unit with the unit marked in the green circle.

2013-06-11 3P03701 20 (22) The command power on, mode auto, fan speed max, setpoint 30 C was sent from the app to the Combi Control. The heat pump started. The status update which was automatically received is shown below. Figure 30: Screenshot of the app showing the status report from the Combi Control unit. The ingoing temperature to the heat pump s indoor unit at this time was 18.4 C. 15:11 The Combi Control unit is disconnected from the power supply and removed from the chamber. An alarm message was received before the SIM-card was removed from the Combi Control unit, see below. Figure 31: Screenshot of the app showing the status report from the Combi Control unit.

2013-06-11 3P03701 21 (22) Results The test results given in this report relate only to the specific item tested and under the specific conditions described, with the specific equipment named and at the specified settings. The diagram below shows the electrical power input to the heat pump and the temperature in the chamber during the testing procedure i.e. between 10:57 and 15:11. The electrical power input to the heat pump is shown as Pevpa and the temperature in the chamber is shown as Tvbin_m. The performed tests show that the Combi Control is able to turn on and off the heat pump and to control the heat pump by fan speed and outgoing temperature when setpoints are changed. During the tests, the Combi Control unit did only control and affect the heat pump when the Combi Control was supposed to do so, i.e. there were no false commands sent. Since the Combi Control unit does not receive feebback from the heat pump, the app reflects the status of the Combi Control unit and not the heat pump. This can be seen for example when the remote control which is supplied with the heat pump is used for controlling the heat pump in between commands sent from the CombiControl unit. 24 2000 22 1500 20 Q [W] 1000 18 T [ C] Pevpa 16 Tvbin_m 500 14 0 12 154,8 204,8 254,8 304,8 354,8 404,8 Mättid [min] Figure 32: Diagram showing power and temperature.