Supplement to HART Communicating Fisher FIELDVUE Digital Valve Controller Instruction Manuals

Similar documents
Fisher FIELDVUE DVC6200 Digital Valve Controller / Magnet Assembly Dimensions

4310/4320 Wireless Position Monitor

Fisher FIELDVUE DVC6200p Digital Valve Controller Device Setup and Accessing Communication and Calibration using Siemens SIMATIC Manager/PDM

ValveLink Mobile Software

Fisher 377 Trip Valve

Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability

ValveLink Software Quick Start Guide

Baumann Way Bronze or Stainless Steel Control Valve

M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves

Baumann Mikroseal Control Valve

4310/4320 Wireless Position Monitor Burst Configuration and Diagnostics

Baumann Little Scotty Bronze Control Valve

Baumann Flexsleev Sanitary Control Valve

Fisher 657 and 667 Diaphragm Actuators

Safety manual for Fisherr ED,ES,ET,EZ, HP, or HPA Valves with 657 / 667 Actuator

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Fisher ENVIRO-SEAL and HIGH-SEAL Packing Systems for Sliding-Stem Valves (Live-Loaded)

ENVIRO-SEAL. Valve Packing Systems Extending service life. Meeting environmental requirements.

AMS ValveLink SNAP-ON Application

Simulation of Process Conditions for Calibration of Fisher Level Controllers and Transmitters Supplement to 249 Sensor Instruction Manuals

Fisher GX Control Valves

Basic Fundamentals Of Safety Instrumented Systems

Rosemount 333 HART Tri-Loop

AMS Suite: Intelligent Device Manager

Hazardous Area Classifications and Protections

Fisher FIELDVUE DVC2000 Digital Valve

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Rosemount 333 HART Tri-Loop

AMS Suite: Intelligent Device Manager with the DeltaV system

Baumann 24000SB Barstock Control Valve

Fisher 4320 Wireless Position Monitor, with On/Off Control Option

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

Fisher CV500 Rotary Globe Control Valve

ValveLink DTM ValveLink PLUG IN for PRM

ROC800-Series Advanced Pulse Module

FIELDVUE. DVC6200 Series Digital Valve Controller A Single Instrument Solution Across Your Facility

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

Full-time Career Opportunities Launch Your Career with Emerson

Fisher Vee-Ball Rotary Control Valves Highly efficient rotary valves to meet a variety of applications

289 Series Spring-Loaded Relief Valves

How To Power A Powerline System On A Cell Phone Or Ipad Or Ipa Computer (For A Cell)

SAGEON SITE MONITOR (SSM) Application Note AN

Fisher 2625, 2625SST, and 2625NS Volume Boosters

Hazardous Area Classifications and Protections

Fisher 846 Electro-Pneumatic Transducer

S-series Mass Connection Solutions

Bristol ControlWave Redundant Control

HART Field Device Specification Fisher FIELDVUE DVC6200 Digital Valve

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

1805 Series Relief Valves

Fisher 377 Trip Valve

Fisher FIELDVUE DVC6200 Digital Valve

THE INPUT/OUTPUT SYSTEM. Key Points

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Introduction To SCADA and Telemetry

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

PREMIUM CLEAN ROOM MONITOR MODELS 8630-CRM-S 8630-CRM-P

CO2 Alarm. Operation. Application

Smart Wireless Solutions. Intelligent Well Production Starts Here

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

AMS Suite: Intelligent Device Manager: An Automated Instrument Calibration System

Fisher D3 Control Valve

Fisher GX 3-Way Control Valve and Actuator System

3500/62 Process Variable Monitor

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Common Mode Choke Filtering Improves CMRR in Ethernet Transformer Applications. Application Note. June 2011

AN2680 Application note

FREQUENCY RESPONSE ANALYZERS

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

Temperature & Humidity SMS Alert Controller

SIS. Fisher FIELDVUE DVC6200 Series Digital Valve Controllers. Contents. Before You Begin... 2

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Current Probes. User Manual

How To Use A Watt Saver On A Microcontroller (Watt Saver) On A Cell Phone Or Mp3 Player

SupportNet Technical Services

ProLink II Software for Micro Motion Transmitters

AMS Suite: Intelligent Device Manager Faster Device Alerts Delivered

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

S-series DeviceNet Interface Card

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

RGC-IR Remote Gas Calibrator for IR400

Custom Products. Magnetic Components. Vishay Dale.

PEDAL POWER 4x4. User s Manual.

Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices

PEDAL POWER DIGITAL. User s Manual.

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Contents. Document information

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Spectrum Technologies, Inc.

Fisher FIELDVUE DVC6200 Digital Valve

S4000TH HART. HART Communication Manual

Model 3051 Pressure Transmitter with HART Protocol

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

167D Series Switching Valves

Transcription:

Instruction Manual Supplement FIELDVUE Digital Valve Controllers Supplement to HART Communicating Fisher FIELDVUE Digital Valve Controller Instruction Manuals FIELDVUE Digital Valve Controller Split Ranging Processes requiring extended rangeability may use two or more control valves. The first valve operates over the first portion of the range. When the first valve is nearly 100% open, the control action begins to open the second valve. This is called split ranging. When split ranging is performed a single signal from the control system is supplied to the valve actuators. This single signal is split among the positioning devices on each valve. The positioning devices are used to achieve full valve travel over the reduced input range. Most applications need a predictable overlap region in the middle of the signal range to avoid a zone of no control. Positioning devices provide accuracy to ensure the correct overlap exists. When split ranging FIELDVUE digital valve controllers, each device requires a minimum voltage available at the instrument terminals of at least 12 volts (See the appropriate instruction manual for details). Many control systems provide a compliance voltage that is less than the minimum requirement of 24 volts for two instruments wired in series. This supplement describes two methods to address the potential discrepancy between the compliance voltage and the requirements of FIELDVUE instruments. Limitations of Split Ranging FIELDVUE Digital Valve Controllers Split ranging FIELDVUE digital valve controllers provides the following limitations: Most control systems cannot provide the 24 volt compliance voltage. A device to boost the compliance voltage may be required, such as the Pak. To communicate with multiple HART instruments on one pair of wires may require the polling addresses for the instruments be nonzero. This means the instrument polling addresses must be reset and the HART devices (either the 475/375 Field Communicator or ValveLink software with a HART modem) must be programmed to poll for instruments at polling addresses other than zero. Use of the HART Tri Loop is limited to communication with only one instrument. The instrument polling addresses may be nonzero, thus limiting communication with a HART multiplexer. Guidelines for Split Ranging FIELDVUE 1. Check the voltage available at the instrument terminals using the method in the instrument instruction manual. 2. Verify that the control system compliance voltage is at least 24 volts DC at 20 ma output. If the compliance voltage is less than 24 volts DC, add a device to boost the compliance voltage (such as the Model AP4380 2000). (Note: the AP4380 2000 does not have any hazardous area approvals. Appropriate non hazardous installations should be selected.) www.fisher.com

FIELDVUE Digital Valve Controllers Instruction Manual Supplement 3. Verify that cable length will not limit HART communication. See the instruction manual for details. 4. For intrinsically safe installations, install approved intrinsic safety barriers between the non hazardous and hazardous areas. Methods of Split Ranging Two methods are available for split ranging FIELDVUE instruments: the traditional method and an alternate method. Traditional Method The traditional method uses the traditional split range wiring where the two instruments are connected in series to a single pair of wires from the control system, as shown in figure 1. With the traditional method: The device used to boost the compliance voltage may be required to operate beyond its specifications. To communicate with multiple HART instruments on one pair of wires requires the polling addresses for the instruments be nonzero. This means the instrument polling addresses must be reset and the HART devices (either the 375 Field Communicator or ValveLink Software with a HART modem) must be programmed to poll for instruments at polling addresses other than zero. Because the instrument polling address for one of the instruments must be nonzero, communication with a HART multiplexer is not possible. Use of the HART Tri Loop is limited to communication with only one instrument. In addition, because the default polling address for the Tri Loop is one (1), the instrument polling addresses must be set in the range of 2 to 15. Alternate Method The alternate method requires more field wiring, but this method: Allows the device used to boost the compliance voltage to operate within its specifications because it supplies a single instrument. The polling addresses can remain at zero (0) because the two instruments are not on the same HART loop. Allows communicating over a HART multiplexer network. Multiple Tri Loops may be used allowing multiple instruments to operate in burst mode. Split ranging with more than two FIELDVUE digital valve controllers is possible. Installation Traditional Method When connecting two instruments in series for a split range application, the compliance voltage must equal at least 24 volts DC. This is generally impractical with most DCS controllers, but quite possible with older analog controllers. For example, a Fisher TL108 controller with 45 volt DC power supply provides a compliance voltage of 27 volts DC at 20 ma output and a C master of 10,000 pf. For other controllers or DCS systems, an isolator or other similar device may be used to increase the compliance voltage. The published compliance voltage of the AP4380 2000 is less than 24 volts DC. However, typical compliance voltage for this isolator is much higher. To ensure sufficient compliance voltage, the distributor can check 2

Instruction Manual Supplement FIELDVUE Digital Valve Controllers compliance voltage of the prior to shipment. This should be done using the technique described in the instrument instruction manual. Generally, a compliance voltage of 25 volts DC at 20 ma output with a guaranteed line voltage of 120 volts AC is adequate for normal lengths of field wiring. Wiring Hook Up The product bulletin describes the product details and limitations (available on the web at www.actionio.com). These should be read and observed. Before installation, configure each instrument with different HART polling addresses (example HART polling addresses 2 and 3). The connections are shown in figure 1. A typical installation has the control system 4 20 ma DC output signal connected to the input terminals. The isolator can be installed in the rack room. Connect the 4 20 ma DC output from the AP4380 2000 to the field wiring. In the field, connect the AP4380 2000 positive () output terminal to the first FIELDVUE instrument terminal. Connect the first FIELDVUE instrument - terminal to the second FIELDVUE instrument terminal. Connect the second FIELDVUE instrument - terminal to the negative (-) output terminal. Figure 1. Typical Installation Schematic, Traditional Method Non-Hazardous Location Hazardous Location FIELDVUE Instrument #1 HART Polling Address 2 Input Range: 4- Controller DC FIELDVUE Instrument #2 HART Polling Address 3 Input Range: 12-20 ma HART Tri Loop (optional) HART Polling Address 1 Configuration Current flowing through the input terminals of the isolator is regenerated at the output terminals of the isolator (at a higher voltage) and flows through both FIELDVUE instruments. Input ranging of the FIELDVUE instruments is easily changed without recalibrating. This is done by configuring the Input Range Low and the Input Range High to the desired values. A typical configuration would be: FIELDVUE Instrument Input Range Low Input Range High Polling Address #1 #2 4 ma 20 ma 2 3 3

FIELDVUE Digital Valve Controllers Instruction Manual Supplement Installation Alternate Method When connecting two instruments in series for this split range application, the compliance voltage requirement from the DCS controller is much lower. This is because the AP4380 2000 is in series with the first FIELDVUE instrument and requires minimum voltage (0.3 volts). The isolator powers only the second FIELDVUE instrument and therefore provides adequate voltage. Wiring Hook Up The product bulletin describes the product details and limitations (available on the web at www.actionio.com). These should be read and observed. The connections are shown in figure 2. For a typical installation, connect the control system positive () output terminal to the AP4380 2000 positive () input terminal. Connect the AP4380 2000 input negative (-) terminal to the first FIELDVUE instrument terminal. Connect the first FIELDVUE instrument - terminal to the control system negative (-) terminal. Connect the AP4380 2000 positive () output terminal to the second FIELDVUE instrument terminal. Connect the AP4380 2000 negative (-) output terminal to the second FIELDVUE instrument - terminal. Figure 2. Typical Installation Schematic, Alternate Method Controller DC Analog In HART Tri Loop (optional) HART Polling Address 1 Non-Hazardous Location Out HART Tri Loop (optional) HART Polling Address 1 Hazardous Location FIELDVUE Instrument #1 HART Polling Address 0 FIELDVUE Instrument #2 HART Polling Address 0 Input Range: 4- Input Range: 12-20 ma 4

Instruction Manual Supplement FIELDVUE Digital Valve Controllers Configuration Current flowing through the input terminal of the isolator is regenerated at the output terminals of the isolator (at a higher voltage) and flows through the second FIELDVUE instrument only. Input ranging of the FIELDVUE instruments is easily changed without recalibrating. This is done by configuring the Input Range Low and the Input Range High to the desired values. A typical configuration would be: FIELDVUE Instrument Input Range Low Input Range High Polling Address #1 #2 4 ma 20 ma 0 0 Multiple Split Range The installation described for the alternate method can be extended to multiple instruments, as shown in figure 3. This architecture allows up to four units to be split ranged. Due to an increase in the signal to noise ratio as the input span decreases, the minimum input span should be limited to 4 ma. Be aware that as the number of units to be split ranged increases, the accuracy of each unit is affected. Figure 3. Typical Multiple Split Range Installation Controller DC Non-Hazardous Location Analog In Analog In Analog In Out Out Out Hazardous Location FIELDVUE Instrument #1 FIELDVUE Instrument #2 FIELDVUE Instrument #3 FIELDVUE Instrument #4 HART Polling Address 0 HART Polling Address 0 HART Polling Address 0 HART Polling Address 0 Input Range: 4-8 ma Input Range: 8- Input Range: 12-16mA Input Range: 16-20 ma 5

FIELDVUE Digital Valve Controllers Instruction Manual Supplement Related Fisher Documents FIELDVUE DVC5000 Series Digital Valve Controllers Instruction Manual Note The DVC5000 digital valve controller is obsolete. Contact your Emerson Process Management sales office if a copy of this instruction manual is needed. FIELDVUE DVC6200 Digital Valve Controller Instruction Manual (D103409X012) FIELDVUE DVC6200 Digital Valve Controller Quick Start Guide (D103410X012) FIELDVUE DVC6000 Digital Valve Controllers Instruction Manual (D102794X012) FIELDVUE DVC6000 Digital Valve Controllers Quick Start Guide (D102762X012) FIELDVUE DVC2000 Digital Valve Controllers Instruction Manual (D103176X012) FIELDVUE DVC2000 Digital Valve Controllers Quick Start Guide (D103203X012) Note Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use, or maintenance of any product. Responsibility for the selection, use, and maintenance of any product remains with the purchaser and end user. Fisher, FIELDVUE, ValveLink, and Tri Loop are marks owned by one of the companies in the Emerson Process Management business division of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. HART is a mark owned by the HART Communication Foundation. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.fisher.com Fisher 6 Controls International LLC 2006, 2011; All Rights Reserved