GFM TIO GFC TIO. GFM with TIO Mounted. GFC with TIO Mounted TOTALIZER INPUT/OUTPUT FLOW MONITOR/CONTROLLER. Design Features

Similar documents
Electronic Control Devices The European Product Catalogue 2007

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Telephone- and leased line modem for industrial applications TD-36

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Temperature & Humidity SMS Alert Controller

Rack mounted telephone- and leased line modem for industrial applications

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

IntesisBox KNX LG Air Conditioning

DC Electronic Loads 8500 series

Quick Connect. quick - simple - efficient.

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

IntesisBox KNX Modbus RTU master

Duct Humidity Transmitter

BW-500 BED WEIGHER USER MANUAL

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Physical Specifications (Custom design available.)

Repeaters and Mimics Data Sheet

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

NC-12 Modbus Application

Regards from the Team at Rheology Solutions.

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

3500/22M Transient Data Interface

IntesisBox Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners

Unidirectional Transmitter/ Receiver Units Introduction

User's Guide. Integrating Sound Level Datalogger. Model Introduction

RS232 Programming and Troubleshooting Guide for Turbo Controls

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Install the DeviceNet Module using the following procedure:

ZC-24DO CANopen I/O Module: 24 Digital Outputs

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server - Mitsubishi Electric G50

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

How To Use A Ds340 (Dsp)

Communicate and view data from meters with one simple device

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Electronic Control Devices The European Product Catalogue 2007

PCS0100en Persy Control Services B.V. Netherlands

NETWORK ENABLED EQUIPMENT MONITOR

IntesisBox KNX Modbus TCP master

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

IntesisBox KNX - LON

For Multi-Parameter Meters see mvx

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Multi-Range Programmable DC Power Supplies 9115 Series

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

40.3. Control Relays and Timers

Installation manual. Generator Paralleling Controller GPC multi-line C

Loop-IP6700 TDMoEthernet

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

R60 USB to CAN interface Manual (1.5 EN)

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

INTRODUCTION FEATURES OF THE ICM

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Industrial Bar Code Scanners

Digital Keypad Use s Manual

IntesisBox KNX Mitsubishi Heavy Industries AC

Indoor / Outdoor Antenna

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

FIREDEX Conventional Fire Panels

FX07 Field Controller

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Energy Management Power Analyzer Type WM14-96 Basic Version

Digital input modules

PowerLogic Sub Meter Display (SMD and SMDOPN)

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

T200, PTP/IEEE 1588 Grandmaster Clock and

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Loop-IP6702 TDMoEthernet

KNX Panasonic Air Conditioners

RS - SPM. Serial parallel translator module

EDI Distributor Control Interface Wiring and Setup Instructions

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

LTM-1338B. Plus Communications Manual

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

F2400 FOM II Series Fiber Optic Modem Technical Manual

Transcription:

GFM GFM with Mounted GFC GFC with Mounted Design Features BULLETIN EM201412 n Displays instantaneous, total and accumulated flow rates. n Built-in Flow Linearizer (10 point linearization of the flow curve). n Up to 47 different volumetric and mass flow engineering units. n Large 13mm (0.51") digits for flow rate and 5.5mm (0.21") for Total. n Digital RS-232 or RS-485 interface (multi-drop capability of up to 64 devices.) n Compact design for unit mount, panel mount, wall mount or field mount applications. n User-programmable, optically-isolated pulse output. n Two programmable, optically-isolated, digital outputs. n Flow controllers, set point command control via local LCD or digital interface. n Programmable set point table with ramping up/down capability up to 16 steps. n Free Configuration and Monitoring Utility software. 26

Signal Input and Signal Output Applications For flow meters and controllers with analog 0-5 (5-10) (0-10)Vdc, 4-20mA input output interface, where flow indications / control and totalizers or alarm functions are required. Also when re-transmission of the flow rate and/or totalizer functions via optically-isolated pulse output or serial communication is desired. Local or programmable set point control for flow controllers (no host PC presence required). Activation of user-supplied equipment via programmable optically-isolated digital outputs when flow alarms or totalizers events are active. Display The graphical LCD display has large 13mm (0.51") digits for flow rate and 5.5mm (0.21") for total and can be set by user to simultaneously show different combination of the flow parameters: flow rate, totalizers, flow alarms, and diagnostic events. All configuration parameter settings are easily accessed via a simple user-interface menu driven by a 6 button key-pad which can be password-protected. n 0-5 Vdc (Input/Output) n 5-10 Vdc (Output only) n 0-10 Vdc (Input/Output) n 4-20 ma (Input/Output) For flow meters and / or flow controllers, provides jumpers selectable for 0-5 Vdc or 4-20 ma analog set point control signals. The flow rate set point can be adjusted locally via key-pad, remotely via host PC using digital communication interface, or programmed in advance using built-in 16 steps batch table with ramping up/down support. Programmable Pulse Output The programmable flow pulse output is operating independently from totalizers and based on configuration settings can provide pulse frequency proportional to instantaneous fluid flow rate. The LCD/keypad and digital communication interface commands are provided to: n Enable/Disable Pulse Output. n Configure Pulse Output start flow rate (in % of full scale). n Configure the Unit/Pulse value (in current volumetric or mass flow units). n Configure Pulse Active On Time (10-6550 ms). Programmable Totalizers provides two independent programmable flow totalizers. Both totalizers are updated every 100 ms and can be set to activate different events. Main totalizer accumulated total is backed-up in EEPROM memory every second. The LCD/keypad and digital communication interface commands are provided to: 27 n Enable/Disable totalizing the flow. n Start the totalizer at a preset flow rate (in % of full scale). n Assign action at a preset total volume (Event Volume). n Configure power on delay (in seconds). n Configure Auto Reset at preset volume. n Configure Auto Reset delay (in seconds). n Reset the totalizer to ZERO. BULLETIN EM201412

Programmable Alarms provides the user with a flexible alarm/warning system that monitors the fluid flow for conditions that fall outside configurable limits as well as visual feedback for the user via the LCD or via an optically-isolated output. The flow alarm has several attributes which can be configured by the user via LCD/Keypad or digital communication interface: n Enable/Disable flow alarm. n Low flow alarm settings (in % of full scale). n High flow alarm settings (in % of full scale). n Flow alarm action delay. n Flow alarm action latch mode. Digital Communication All process data and settings can be read and modified manually via local LCD Key-pad or through the digital RS- 232 or RS-485 communication interface. Proprietary ASCII software interface command set and free Communication Utility software are provided. TABLE 17 - SPECIFICANS ADC/DAC RESOLUN: ANALOG INPUTS ANALOG OUTPUTS: LCD: KEY-PAD: PULSE OUTPUT: DIGITAL OUTPUT: DIGITAL INTERFACE: PROTOCOL: SPEED: CONFIGURAN: ADDRESSING: TYPE: 12 bit 0-5 Vdc, 4-20 ma, 5-10 Vdc (jumper-selectable), 0-10 Vdc (special order) 0-5 Vdc, 4-20 ma (jumper-selectable) 128x64 graphic LCD with instantaneous Flow reading and Total volume indication. Adjustable LCD contrast and back light. Local 6 tactical push buttons. User-programmable, optically-isolated, with preset active low time interval (10 6550 ms). Two programmable, optically-isolated, UCE @ 40Vdc, ICE @ 150 ma (Voltage Isolation: 250 Vrms). RS-232 or RS-485 (multidrop capability up to 64 devices) Proprietary ASCII software interface command set. 1200-2400 - 4800-9600 -19200 38400 57600 115200 baud (user selectable). Stop bit: 1 Data bits: 8 Parity: None Flow Control: None Maximum 255 addresses (for RS-485 option only). RS232 or RS485 2-wire. POWER REQUIREMENTS: 12 26 Vdc (up to 60 ma maximum). INTERFACE CONNECTORS: Process I/O signals and Digital RS-232/RS-485 interface miniature 9 pin female D-SUB connector. Digital optically-isolated outputs: TERM BLOCK HEADER 4POS 3.5MM Male Pins, Shrouded. ENVIRONMENT: Installation Level II, Pollution Degree II, (Per IEC 664). ELECTROMAGNETIC COMPATIBILITY: OPERATING TEMPERATURE: Compliant ref. 89/336/EEC as amended. Emission Standard: EN 55011:1991, Group 1, Class A Immunity Standard: EN 55082-1:1992-10 C to +70 C (14 F to +158 F). BULLETIN EM201412 DIMENSIONS: 86.4 x 76.2 x 19.1 mm (3.4" x 3.0" x 0.75") - W x H x D. WEIGHT: Appr. 125g / 0.3 lbs 28

ACCESSORIES TABLE 18 - ACCESSORY'S PART NUMBER DESCRIPN WHEN REQUIRED 29 KIT-TM-DD KIT-TM-RD KIT-TM-FD KIT-TC-110NA-2C KIT-TC-110NA-2N KIT-TC-110NA-4C KIT-TC-110NA-4N KIT-TC-230EU-2C KIT-TC-230EU -2N KIT-TC-230EU -4C KIT-TC-230EU -4N KIT-TC-240AU-2C KIT-TC-240AU-2N KIT-TC-240AU-4C KIT-TC-240AU-4N KIT-TC-240UK-2C KIT-TC-240UK -2N KIT-TC-240UK -4C KIT-TC-240UK-4N KIT-TC-240UK-2AC KIT-TC-240UK-4AC GFM flow meter mounting kit, shielded cable with two 9 pins D-connectors for process signals and communication branch. GFM flow meter mounting kit, 4 wire cable between GFM RJ11 and 9 pin D-connector. GFM flow meter mounting kit, flat wire cable between GFM and 9 pin D-connectors. plug 110 Vac to 12 Vdc power supply, communication branch. plug 110 Vac to 12 Vdc power supply. plug 110 Vac to 24 Vdc power supply, communication branch. plug 110 Vac to 24 Vdc power supply. 230 Vac to 12 Vdc power supply, communication branch. 230 Vac to 12 Vdc power supply. 230 Vac to 24 Vdc power supply, communication branch. 230 Vac to 24 Vdc power supply. plug 240 Vac to 12 Vdc power supply, communication branch. plug 240 Vac to 12 Vdc power supply. plug 240 Vac to 24 Vdc power supply, communication branch. plug 240 Vac to 12 Vdc power supply. Vac to 12 Vdc power supply, communication branch. Vac to 12 Vdc power supply. Vac to 24 Vdc power supply, communication branch. Vac to 24 Vdc power supply. Vac to 12 Vdc power supply, communication branch, analog 4-20 ma output branch from GFC. Vac to 24 Vdc power supply, communication branch, analog 4-20 ma output branch from GFC. GFM + digital communication with Host PC or PLC. GFM (12 Vdc power option only), 5-10 Vdc input, no GFM, 0-5Vdc input no GFC, 0-5 Vdc input, North America 12 Vdc power supply, GFC, 0-5 Vdc input, North America 12 Vdc power supply. GFC, 0-5 Vdc input, North America 12 Vdc power supply. GFC, 0-5 Vdc input, North America 24 Vdc power supply. GFC, 0-5 Vdc input, Europe 12 Vdc power supply, digital communication. GFC, 0-5 Vdc input, Europe 12 Vdc power supply. GFC, 0-5 Vdc input, Europe 24 Vdc power supply, digital communication. GFC, 0-5 Vdc input, Europe 24 Vdc power supply. GFC, 0-5 Vdc input, Australia 12 Vdc power supply, GFC, 0-5 Vdc input, Australia 12 Vdc power supply. GFC, 0-5 Vdc input, Australia 24 Vdc power supply, GFC, 0-5 Vdc input, Australia 24 Vdc power supply. GFC, 0-5 Vdc input, UK 12 Vdc power supply, GFC, 0-5 Vdc input, UK 12 Vdc power supply. GFC, 0-5 Vdc input, UK 24 Vdc power supply, GFC, 0-5 Vdc input, UK 24 Vdc power supply. GFC, 0-5 Vdc input, UK 12 Vdc power supply, digital communication, analog 4-20 ma output branch from GFC. GFC, 0-5 Vdc input, UK 24 Vdc power supply, digital communication, analog 4-20 ma output branch from GFC. KIT-TM GFM flow meter mounting kit, no cables. GFM, user-supplied custom cables. KIT-TC GFC flow controller mounting kit, no cables. GFC, user-supplied custom cables. CBL-DA9-X 9 conductor round shielded cable consisting of a 9 pin Female D Sub-Connector (plug) on one end, and loose wires on the other end. For stand alone option, user-supplied power supply. Note: X represent the length of the cable in feet BULLETIN EM201412

ORDERING INFORMAN FOR TOTALIZER FLOW MONITOR / CONTROLLER MODEL DISPLAY / KEYPAD N No Display / No Key Pad L LCD / Key Pad INPUT SIGNAL A 0-5 VDC B 4-20 ma C 0-10 VDC D 5-10 VDC OUTPUT SIGNAL A 0-5 VDC B 4-20 ma C 0-10 VDC DIGITAL INTERFACE 2 RS-232 5 RS-485 L A A 2 EXAMPLE: -LAA2 Totalizer I/O Flow Monitor / Controller with LCD Key Pad, 0-5 VDC Input, 0-5 VDC Output and RS-232 Digital Interface. BULLETIN EM201412 30