A. This Section includes the following sanitary drainage piping specialties:

Similar documents
SECTION SOIL AND WASTE SYSTEMS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

FLOOR AND AREA DRAINS

SECTION COMMERCIAL PLUMBING FIXTURES

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

SECTION FACILITY STORM DRAINAGE PIPING

GRATES AND DRAINS HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

ROOF DRAINS TABLE OF CONTENTS

roline Commercial Drainage Products Catalog & Price List Effective April 2, 2012 watts.com

CODE GUIDE 302 and Glossary of Industry Terms

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION STORM DRAINAGE SYSTEM

PLUMBING ROUGH IN INSPECTION

CHAPTER 11 STORM DRAINAGE

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Jay R. Smith Mfg. Co.

CLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS

Fabricated Drainage Products

CHAPTER 11 STORM DRAINAGE

FLOOR DRAINS FLOOR DRAINS. SUPER-FLO Features

FIRING RANGE PHASE 1 DESIGN

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

Plugging Home Drains to Prevent Sewage Backup

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Jay R. Smith Mfg. Co.

Carriers, Fixtures & Piping

A. This Section includes the following for soil, waste, and vent piping inside the building:

A. Submit data on all materials, fittings, accessories and equipment.

SECTION GROUND WATER STORAGE TANKS

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

SECTION PLUMBING FIXTURES. A. Section includes the following conventional plumbing fixtures and related components:

EMERGENCY PLUMBING FIXTURES

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

- 3 - SANITARY SEWER BACK-UP

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

When Should Examination Preparation Begin?

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

2006 Codes. Please verify the following before calling for inspection

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Residential Plumbing BCN 1058

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

What to Expect From the Examination. How to Study the Plumbing Codes

PRESSURE REDUCING CONTROL VALVE

Top 10+ Mistakes of DWV plumbing design

Packaged Terminal Air Conditioner Wall Sleeve Installation

B. Accessible Fixture: Plumbing fixtures that can be approached, entered, and used by people with disabilities.

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

SECTION STORM DRAIN SYSTEM

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

SECTION DUCTILE IRON PIPE AND FITTINGS

Wastewater Capital Projects Management Standard Construction Specification

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

Basic Principles for Sizing Grease Interceptors

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

MIFAB Floor Drain Selection Guide

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

Mitigating Basement Backups

SANITARY SEWER SPECIFICATIONS

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

frostdrainage.com Floor Drains & Rodding Eyes

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

foundation designed to keep water out of the basement.

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

CHAPTER 7 SANITARY DRAINAGE

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

MIFAB INTERCEPTOR SELECTION GUIDE

SECTION SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

Amendments to the 2012 International Plumbing Code

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

LS 2540 SEWER LATERALS AND INSPECTION TEES

2010 Residential Water Heater Replacement Check List

How To Make A House Safe

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Float and Thermostatic Traps Series H, C and X

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Copper and Copper Alloy Tube, Pipe and Fittings

SECTION POLYVINYL CHLORIDE (PVC) PIPE

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Element D Services Plumbing

SECTION 807 PUMP STATION REHABILITATION

SECTION DUCTILE IRON PIPE AND FITTINGS

Chapter 3 Pre-Installation, Foundations and Piers

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Flygt Ball Check Valves

DIVISION 22 PLUMBING PLUMBING EQUIPMENT Domestic Water Heaters

SECTION UNDERGROUND ELECTRIC SERVICE

SMITH MFG. CO. PROTECT YOUR INVESTMENTS. Automatic Backwater Valve SMITH MORRIS GROUP INTERNATIONAL.

PUBLIC RESTROOMS, DESIGN INTENT

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Town House Center Highway North Huntingdon, PA 15642

CHAPTER 11 STORM DRAINAGE

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Transcription:

SECTION 221319 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Backwater valves. 2. Floor drains and floor sinks. 3. Roof flashing assemblies. 4. Miscellaneous sanitary drainage piping specialties. 5. Grease traps. 1.2 SUBMITTALS A. Product Data: For each type of product indicated, include rated capacities, materials, finishes, dimensions, required clearances, operating characteristics, and accessories. B. Operation and maintenance data for the 1. Grease traps. 2. Grease interceptors. 1.3 QUALITY ASSURANCE A. Drainage piping specialties shall bear label, stamp, or other markings of specified testing agency. PART 2 - PRODUCTS 2.1 BACKWATER VALVES A. Horizontal, Cast-Iron Backwater Valves: b. Smith, Jay R. Mfr. Co.; Division of Smith Industries, Inc. c. Watts Drainage Products Inc. d. Zurn Plumbing Products Group; Specification Drainage Operation. 2. Standard: ASME A112.14.1. 3. Size: Same as connected piping. 4. Body: Cast iron. 221319-1

5. Cover: Cast iron with bolted or threaded access check valve. 6. End Connections: Hub and spigot or hubless to match adjacent piping. 7. Type Check Valve: Removable, bronze, swing check, factory assembled or field modified to hang closed. 8. Extension: ASTM A 74, Service class; full-size, cast-iron, soil-pipe extension to fieldinstalled cleanout at floor; replaces backwater valve cover. B. Drain-Outlet Backwater Valves: b. Smith, Jay R. Mfr. Co.; Division of Smith Industries, Inc. c. Watts Drainage Products Inc. d. Zurn Plumbing Products Group; Specification Drainage Operation. 2. Size: Same as floor drain outlet. 3. Body: Cast iron or bronze made for vertical installation in bottom outlet of floor drain. 4. Check Valve: Removable ball float. 5. Inlet: Threaded. 6. Outlet: Threaded or spigot. 2.2 FLOOR DRAINS AND FLOOR SINKS A. Cast-Iron Floor Drains; Equipment Rooms and Unfinished Areas: Drainage Products, FD-320-5-7 or a comparable product by one of the 2. Standard: ASME A112.6.3. 3. Pattern: Floor drain. 4. Body Material: Gray iron. 5. Seepage Flange: Not required. 6. Anchor Flange: Required. 7. Clamping Device: Required in surfaces with a waterproof membrane. 8. Outlet: Bottom. 9. Coating on Interior and Exposed Exterior Surfaces: Epoxy. 10. Sediment Bucket: Shallow-type. 11. Top or Strainer Material: Ductile Iron. 12. Top of Body and Strainer Finish: Ductile Iron. 13. Top Shape: Round. 14. Dimensions of Top or Strainer: 8 inch diameter. 15. Top Loading Classification: Heavy Duty. 16. Funnel: Not required. 17. Inlet Fitting: Gray iron, with threaded inlet and threaded or spigot outlet, and trap-seal 221319-2

B. Cast-Iron Floor Drains; Finished Areas: Drainage Products, FD-100-A5-7 or a comparable product by one of the 2. Standard: ASME A112.6.3. 3. Pattern: Floor drain. 4. Body Material: Gray iron. 5. Seepage Flange: Required. 6. Anchor Flange: Required. 7. Clamping Device: Required in surfaces with a waterproof membrane. 8. Outlet: Bottom. 9. Coating on Interior and Exposed Exterior Surfaces: Epoxy. 10. Sediment Bucket: Not required. 11. Top or Strainer Material: Nickel bronze. 12. Top of Body and Strainer Finish: Nickel bronze. 13. Top Shape: Square. 14. Dimensions of Top or Strainer: 6 inch by 6 inch square. 15. Top Loading Classification: Medium Duty. 16. Funnel: Not required. 17. Inlet Fitting: Gray iron, with threaded inlet and threaded or spigot outlet, and trap-seal C. Cast-Iron Floor Drains; ADA Floor Drain: Drainage Products, FD-100-RS-517-7 or a comparable product by one of the 2. Standard: ASME A112.6.3. 3. Pattern: Floor drain. 4. Body Material: Gray iron. 5. Seepage Flange: Required. 6. Anchor Flange: Required. 7. Clamping Device: Required in surfaces with a waterproof membrane. 8. Outlet: Bottom. 9. Coating on Interior and Exposed Exterior Surfaces: Epoxy. 10. Sediment Bucket: Not required. 11. Top or Strainer Material: Nickel bronze. 12. Top of Body and Strainer Finish: Nickel bronze. 13. Top Shape: Rectangular. 14. Dimensions of Top or Strainer: 5 inch by 17 inch rectangular strainer. 15. Top Loading Classification: Medium Duty. 221319-3

16. Funnel: Not required. 17. Inlet Fitting: Gray iron, with threaded inlet and threaded or spigot outlet, and trap-seal D. Cast-Iron Shower Drain: Drainage Products, FD-100-A6 or a comparable product by one of the 2. Standard: ASME A112.6.3. 3. Pattern: Floor. 4. Body Material: Gray iron. 5. Seepage Flange: Required. 6. Anchor Flange: Required. 7. Clamping Device: Required in surfaces with a waterproof membrane. 8. Outlet: Bottom. 9. Coating on Interior and Exposed Exterior Surfaces: Epoxy. 10. Sediment Bucket: Not required. 11. Top or Strainer Material: Nickel bronze. 12. Top of Body and Strainer Finish: Nickel bronze. 13. Top Shape: Round. 14. Dimensions of Top or Strainer: 6 inch diameter. 15. Top Loading Classification: Medium Duty. 16. Funnel: Not required. 17. Inlet Fitting: Gray iron, with threaded inlet and threaded or spigot outlet, and trap-seal E. Cast-Iron Floor Sink; Equipment Rooms and Unfinished Areas: Drainage Products, FD-760-7-150 or a comparable product by one of the 2. Standard: ASME A112.6.7. 3. Body Material: Gray iron. 4. Seepage Flange: Required. 5. Clamping Device: Required in surfaces with a waterproof membrane. 6. Outlet: Bottom. 7. Coating on Interior and Exposed Exterior Surfaces: Acid-resistant enamel. 8. Strainer: Dome-type. 9. Grate Material: Cast-iron. 10. Grate Finish: Acid-resistant enamel. 11. Top Shape: Square. 221319-4

12. Grate Coverage: 1/2. 13. Dimensions: 12 inch square top with 10 inch deep sump. 14. Top Loading Classification: Light Duty. 15. Outlet Fitting: Spigot outlet, and trap-seal F. Cast-Iron Floor Sink; Finished Areas: Drainage Products, FD-710-7 or a comparable product by one of the 2. Standard: ASME A112.6.7. 3. Body Material: Gray iron. 4. Seepage Flange: Required. 5. Clamping Device: Required in surfaces with a waterproof membrane. 6. Outlet: Bottom. 7. Coating on Interior and Exposed Exterior Surfaces: Acid-resistant enamel. 8. Strainer: Dome-type. 9. Grate Material: Cast-iron. 10. Grate Finish: Acid-resistant enamel. 11. Top Shape: Square. 12. Grate Coverage: 3/4. 13. Dimensions: 8 inch square top with 6 inch deep sump. 14. Top Loading Classification: Light Duty. 15. Outlet Fitting: Spigot outlet, and trap-seal 2.3 ROOF FLASHING ASSEMBLIES A. Roof Flashing Assemblies: a. Acorn Engineering Company; Elmdor/Stoneman Div. b. Thaler Metal Industries Ltd. B. Description: Manufactured assembly made of minimum 4.0-lb/sq. ft., 0.0625-inch- thick, lead flashing collar and skirt extending at least 8 inches from pipe, with galvanized-steel boot reinforcement and counterflashing fitting. 1. Open-Top Vent Cap: Without cap. 2. Extended Vent Cap: Where indicated or required, with field-installed, vandal-proof vent cap. 221319-5

2.4 MISCELLANEOUS SANITARY DRAINAGE PIPING SPECIALTIES A. Open Drains: 1. Description: Shop or field fabricate from ASTM A 74, Service class, hub-and-spigot, cast-iron, soil-pipe fittings. Include P-trap, hub-and-spigot riser section; and where required, increaser fitting joined with ASTM C 564, rubber gaskets. 2. Size: Same as connected waste piping with increaser fitting of size indicated. B. Deep-Seal Traps: 1. Description: Cast-iron or bronze casting, with inlet and outlet matching connected piping and cleanout trap-seal 2. Size: Same as connected waste piping. a. NPS 2: 4-inch- minimum water seal. b. NPS 2-1/2 and Larger: 5-inch- minimum water seal. C. Floor-Drain, Trap-Seal Primer Fittings: 1. Description: Cast iron, with threaded inlet and threaded or spigot outlet, and trap-seal 2. Size: Same as floor drain outlet with NPS 1/2 side inlet. D. Air-Gap Fittings: 1. Standard: ASME A112.1.2, for fitting designed to ensure fixed, positive air gap between installed inlet and outlet piping. 2. Body: Bronze or cast iron. 3. Inlet: Opening in top of body. 4. Outlet: Larger than inlet. 5. Size: Same as connected waste piping and with inlet large enough for associated indirect waste piping. E. Sleeve Flashing Device: 1. Description: Manufactured, cast-iron fitting, with clamping device, that forms sleeve for pipe floor penetrations of floor membrane. Include galvanized-steel pipe extension in top of fitting that will extend 2 inches above finished floor and galvanized-steel pipe extension in bottom of fitting that will extend through floor slab. 2. Size: As required for close fit to riser or stack piping. F. Stack Flashing Fittings: 1. Description: Counterflashing-type, cast-iron fitting, with bottom recess for terminating roof membrane, and with threaded or hub top for extending vent pipe. 2. Size: Same as connected stack vent or vent stack. G. Vent Caps: 1. Description: Cast-iron body with threaded or hub inlet and vandal-proof design. Include vented hood and setscrews to secure to vent pipe. 2. Size: Same as connected stack vent or vent stack. 221319-6

H. Air-Admittance Valves: a. Sioux Chief Manufacturing Co., Inc. b. Studor, Inc. 2. Description: Plastic housing with mechanically-operated sealing diaphragm, designed to admit air into vent piping and to prevent transmission of sewer gas into building. 3. Stack Vent Valve: a. Standard: ASSE 1050. b. Application: Termination of vent stack inside of building. 4. Fixture Vent Valve: a. Standard: ASSE 1051. b. Application: Connection to a vent serving a single fixture. 2.5 GREASE TRAPS A. Grease Traps: b. MIFAB, Inc. c. Rockford Sanitary Systems, Inc. d. Smith, Jay R. Mfg. Co.; Division of Smith Industries, Inc. e. Tyler Pipe; Wade Div. f. Watts Drainage Products Inc. g. Zurn Plumbing Products Group; Specification Drainage Operation. 2. Standard: ASME A112.14.3 and PDI-G101, for intercepting and retaining fats, oils, and greases from food-preparation or -processing wastewater. 3. Plumbing and Drainage Institute Seal: Required. 4. Body Material: Cast iron or steel. 5. Interior Lining: Corrosion-resistant enamel. 6. Exterior Coating: Corrosion-resistant enamel. 7. Flow Rate: See Drawings. 8. Grease Retention Capacity: See Drawings. 9. Inlet and Outlet Size: See Drawings. 10. End Connections: Flanged, hub, or threaded. 11. Cleanout: Integral. 12. Mounting: Above floor or recessed, flush with floor as indicated on Drawings. 13. Flow-Control Fitting: Required. 14. Operation: Manual cleaning. 221319-7

PART 3 - EXECUTION 3.1 INSTALLATION A. Refer to Division 22 Section "Common Work Results for Plumbing" for piping joining materials, joint construction, and basic installation requirements. B. Install backwater valves in building drain piping. For interior installation, provide cleanout deck plate flush with floor and centered over backwater valve cover, and of adequate size to remove valve cover for servicing. C. Install floor drains at low points of surface areas to be drained. Set grates of drains flush with finished floor, unless otherwise indicated. 1. Position floor drains for easy access and maintenance. 2. Set floor drains below elevation of surrounding finished floor to allow floor drainage. Set with grates depressed according to Architectural Drawings or to the following drainage area radii if not indicated otherwise: a. Radius, 30 Inches or Less: Equivalent to 1 percent slope, but not less than 1/4- inch total depression. b. Radius, 30 to 60 Inches: Equivalent to 1 percent slope. c. Radius, 60 Inches or Larger: Equivalent to 1 percent slope, but not greater than 1- inch total depression. 3. Install floor-drain flashing collar or flange so no leakage occurs between drain and adjoining flooring. Maintain integrity of waterproof membranes where penetrated. 4. Install individual traps for floor drains connected to sanitary building drain, unless otherwise indicated. D. Install flashing fittings on sanitary stack vents and vent stacks that extend through roof. E. Assemble open drain fittings and install with top of hub 2 inches above floor. F. Install deep-seal traps on floor drains and other waste outlets, if indicated. G. Install floor-drain, trap-seal primer fittings on inlet to floor drains that require trap-seal primer connection. 1. Exception: Fitting may be omitted if trap has trap-seal primer connection. 2. Size: Same as floor drain inlet. H. Install air-gap fittings on draining-type backflow preventers and on indirect-waste piping discharge into sanitary drainage system. I. Install sleeve flashing device with each riser and stack passing through floors with waterproof membrane. J. Install vent caps on each vent pipe passing through roof. K. Install grease traps, including trapping, venting, and flow-control fitting, according to authorities having jurisdiction and with clear space for servicing. 221319-8

1. Above-Floor Installation: Set unit with bottom resting on floor, unless otherwise indicated. 2. Flush with Floor Installation: Set unit and extension, if required, with cover flush with finished floor. L. Install traps on plumbing specialty drain outlets. Omit traps on indirect wastes unless trap is indicated. M. Install escutcheons at wall, floor, and ceiling penetrations in exposed finished locations and within cabinets and millwork. Use deep-pattern escutcheons if required to conceal protruding pipe fittings. 3.2 CONNECTIONS A. Piping installation requirements are specified in other Division 15 Sections. Drawings indicate general arrangement of piping, fittings, and specialties. B. Install piping adjacent to equipment to allow service and maintenance. C. Grease Trap: Connect inlet and outlet to unit, and connect flow-control fitting and vent to unit inlet piping. Install valve on outlet of automatic drawoff-type unit. 3.3 LABELING AND IDENTIFYING A. Equipment Nameplates and Signs: Install engraved plastic-laminate equipment nameplate or sign on or near each grease trap. B. Distinguish among multiple units, inform operator of operational requirements, indicate safety and emergency precautions, and warn of hazards and improper operations, in addition to identifying unit. Nameplates and signs are specified in Division 15 Section "Identification for Plumbing Piping and Equipment." 3.4 PROTECTION A. Protect drains during remainder of construction period to avoid clogging with dirt or debris and to prevent damage from traffic or construction work. B. Place plugs in ends of uncompleted piping at end of each day or when work stops. END OF SECTION 221319-9