Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Similar documents
Inductive sensor NI10-M18-Y1X-H1141

Pressure transmitter For general industrial applications Model A-10

Compact pressure switch Flameproof enclosure Ex d Model PCA

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Precision digital pressure gauge Model CPG1500

Technical Data. Dimensions

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Redundancy Module QUINT-DIODE/40

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Three-phase monitoring relay CM-PFE

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Rosemount 333 HART Tri-Loop

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

RM4TG20 three-phase network control relay RM4-T - range V

Rosemount 333 HART Tri-Loop

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SEISMIC VELOCITY TRANSDUCER T1-40

Safety technique. Emergency stop module BO 5988 safemaster

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

CompactLogix Power Supplies Specifications

MINI MCR-SL-R-UI(-SP)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

J TB/TW Temperature limiter, temperature monitor

Flow switches Series AD/VH

Digital input modules

Hand-held thermometer Model CTH7000

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Power Supplies 3. SDN-P DIN Rail Series

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Technical Data. Dimensions

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

38 Series - Relay interface modules A

Analog signal converters CC-E I/I Current / current isolators

Instruction Manual. T3111 T3111L T3111P T3111Ex

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Cross-beam scanning system to detect slim objects. 100 mm in

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Technical Information RIA14

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Threaded resistance thermometer Model TR10-C, with protection tube

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

38 Series - Relay interface modules A

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

TX OPEN RS232/485 module

Adjustment functions for both span and shift have been incorporated

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Plastic tube flowmeters Series PT/PS

Relés e Contatores de Estado Sólido SIRIUS

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Features. Picture. Specifications

Inductive slot sensor

Series 8146/5-V37 and Series 8150/5-V37

Waveguide Access Point WGA631. Product Guide

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

PHOENIX CONTACT Features

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Relative pressure transmitter type 520

Digital Pressure Measuring Instrument MDR480

Telephone- and leased line modem for industrial applications TD-36

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

How To Use A Flowmeter

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MasterINTERFACE 39 Series - Relay interface modules

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Transcription:

Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building and plant construction Special features For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection For the connection of reed chains in a potentiometer circuit Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magwik Connection terminals also accessible from the outside Accuracy < 0.2 K / 0.1 % Fig. left: head mounting version, model T15.H Fig. right: rail mounting version, model T15.R Description These temperature transmitters are designed for universal use in plant and machine building, and also in the process industry. They offer high accuracy and excellent protection against electromagnetic influences (EMI). Via the WIKAsoft-TT configuration software and the model PU-448 programming unit, the model T15 temperature transmitters can be parameterised very easily, quickly and with a clear overview. The model T15 transmitter also has diverse supervisory functionality, such as the monitoring of the sensor wire resistance and sensor-break detection in accordance with NAMUR NE89 as well as monitoring of the measuring range. Moreover, these transmitters have comprehensive cyclic self-monitoring functionality. Besides the selection of the sensor type and the measuring range, the software enables the error signaling operation, damping and several measuring point descriptions to be stored. Furthermore, the WIKAsoft-TT software offers a line recording functionality where the temperature profile for the sensor connected to the T15 can be displayed. WIKA data sheet TE 15.01 05/2016 Page 1 of 10

Specifications Power supply Power supply U B Load R A Ex-relevant connection values DC 8 35 V R A (U B - 8 V) / 0.0215 A with R A in Ω and U B in V see Safety-relevant characteristics (explosion-protected version) Load diagram The permissible load depends on the loop supply voltage. Load RA in Ω 14141236.02 Min. voltage Operating voltage Ex instruments Non-Ex instruments Power supply U B in V Designation of connection terminals Input Resistance thermometer/ resistance sensor in 4-wire 3-wire 2-wire Potentiometer Output 4... 20 ma loop Connection programming unit PU-448 T15.H T15.R Page 2 of 10 WIKA data sheet TE 15.01 05/2016

Temperature transmitter input Sensor type Max. configurable measuring range (MR) Standard Minimum measuring span (MS) Resistance sensor Pt100 Pt1000-200... +850 C (-328... +1,562 F) -200... +850 C (-328... +1,562 F) IEC 60751:2008 IEC 60751:2008 10 K (50 F) or 3.8 Ω (greater value applies) Potentiometer 1) Reed chains 0... 100 % (= ^ min. 1... max. 50 kω) 10 % (= ^ min. 1 kω) Measuring current at the measurement Connection methods Max. 0.2 ma (Pt100/Pt1000) Max. 0.1 ma (Reed) 1 sensor in 2-, 3-, 4-wire connection (for further information, please refer to Designation of connection terminals ) Lead resistance 3- and 4-wire connection: max. 50 Ω each wire 2-wire connection: configurable Input of the values via WIKAsoft-TT 1) R total: 10... 50 kω Basic configuration Sensor Pt100 Connection method 3-wire connection Measuring range 0... 150 C Error signalling Downscale Damping Off Analogue output, output limits, signalling Analogue output, configurable Linear to temperature per IEC 60751 Output limits per NAMUR NE43 Lower limit Upper limit 3.8 ma 20.5 ma Current value for signalling, configurable per NAMUR NE43 Downscale Upscale < 3.6 ma (3.5 ma) > 21.0 ma (21.5 ma) Time response Switch-on time (time to get the first measured value) Warm-up time Response time Damping Max. 3 s After max. 4 minutes the instrument will function to the specifications (accuracy) < 0.4 s Configurable between 1 s and 60 s Typical measuring rate Measured value update with 2- and 4-wire connection, approx. 20/s with 3-wire connection/potentiometer, approx. 5/s WIKA data sheet TE 15.01 05/2016 Page 3 of 10

Accuracy specifications 4... 20 ma Sensor Input (digital) CPU Output (analogue) Loop U i External sensor not included Accuracy input R digital I digital Accuracy output R sensor Overall instrument accuracy l loop The product-specific accuracy specifications refer to the overall instrument (Error overall = Error input + Error output ). To determine the overall error, all possible types of error must be considered. These are summarised in the following table. Special features Reference conditions Accuracy specifications Calibration temperature T ref = 23 C ±3 K Power supply U i_ref = 24 V Atmospheric pressure = 860... 1,060 hpa All accuracy specifications refer to the reference conditions. Measuring deviation per DIN EN 60770, NE145 2) Pt100, Pt1000 0.2 K or 0.1 % (greater value applies) MS < 200 K: 0.2 K MS > 200 K: 0.1 % of MS see chart Measuring deviation via span Potentiometer Relative accuracy: 0.2 % (R part /R overall in %) Absolute accuracy: 1 % (R part /R overall in Ω) Mean temperature coefficient (TC) every 1 K ambient temperature deviation from T ref ±0.01 % of the MS see chart Deviation of the current span via ambient temperature range Influence of power supply every 1 V voltage change from U i_ref Long-term drift in line with IEC 61298-2 per year ±0.005 % of the MS < 0.1 % of the MS ±0.01 % of the MS ±0.005 % of the MS < 0.1 % of the MS 2) In the event of interference caused by high-frequency electromagnetic fields in a frequency range from 80 to 400 MHz, an increased measuring deviation of up to 0.8 % is expected. During transient interferences (e.g. burst, surge, ESD) take into account an increased measuring deviation of up to 1.5 %. Measuring deviation via span Deviation of the current span via ambient temperature range 1.2 0.12 Measuring deviation in K 1 0.8 0.6 0.4 0.2 Measuring deviation Deviation in ma 0.10 0.08 0.06 0.04 0.02 Deviation in ma 0 0 0 200 400 600 800 1000 1200-50 0 50 100 Span in K Ambient temperature (T ref = 23 C) Page 4 of 10 WIKA data sheet TE 15.01 05/2016

Monitoring Sensor break monitoring Sensor short-circuit Measuring range monitoring Drag pointer (internal temperature of the electronics) Configurable Standard: downscale Configurable Standard: downscale Monitoring of the set measuring range for upper/lower deviations configurable Standard: deactivated Comparative value in relation to the permissible ambient temperature Case T15.H head mounting version T15.R rail mounting version Material Plastic PBT, glass-fibre reinforced Plastic Weight 45 g 0.2 kg Ingress protection Connection terminals, captive screws, wire cross-section Solid wire Wire with end splice Screwdriver IP00 Electronics completely potted 0.14... 2.5 mm² (AWG 24... 14) 0.14... 1.5 mm² (AWG 24... 16) Cross head (Pozidrive tip), size 2 (ISO 8764) Tightening torque 0.5 Nm 0.5 Nm IP20 0.14... 2.5 mm² (AWG 24... 14) 0.14... 2.5 mm² (AWG 24... 14) Slotted, 3 x 0.5 mm (ISO 2380) Ambient conditions Permissible ambient temperature range {-50} -40... +85 {+105} C {-58} -40... +185 {+221} F Climate class per IEC 654-1:1993 Maximum permissible humidity Model T15.H per IEC 60068-2-38:2009 Model T15.R per IEC 60068-2-30:2005 Vibration resistance per IEC 60068-2-6:2008 Shock resistance per IEC 68-2-27:2009 Salt fog per IEC 68-2-52:1996, IEC 60068-2-52:1996 Condensation Free fall in line with IEC 60721-3-2:1997, DIN EN 60721-3-2:1998 Electromagnetic compatibility (EMC) 2) per DIN EN 55011:2010, DIN EN 61326-2-3:2013, NAMUR NE21:2012, GL 2012 VI Part 7 Cx (-40... +85 C, 5... 95 % r. h.) Test max. temperature variation 65 C / -10 C, 93 % ±3 % r. h. Test max. temperature 55 C, 95 % r. h. Test Fc: 10... 2,000 Hz; 10 g, amplitude 0.75 mm Acceleration / shock width 30 g / 11 ms 100 g / 6 ms Severity level 1 Model T15.H: acceptable Model T15.R: acceptable in vertical mounting position Drop height 1.5 m Emission (group 1, class B) and interference immunity (industrial application) [HF field, HF cable, ESD, Burst, Surge] { } Items in curved brackets are options for an additional price, not for ATEX versions of the head mounting version and not for T15.R rail mounting version 2) In the event of interference caused by high-frequency electromagnetic fields in a frequency range from 80 to 400 MHz, an increased measuring deviation of up to 0.8 % is expected. During transient interferences (e.g. burst, surge, ESD) take into account an increased measuring deviation of up to 1.5 %. WIKA data sheet TE 15.01 05/2016 Page 5 of 10

Safety-relevant characteristics (explosion-protected version) Models T15.x-AI, T15.x-AC Intrinsically safe connection values for the current loop (4... 20 ma) Protection level Ex ia IIC/IIB/IIA, Ex ia IIIC or Ex ic IIC/IIB/IIA Parameters Models T15.x-AI, T15.x-AC Model T15.x-AI Gas hazardous application Dust hazardous application Terminals + / - + / - Voltage U i DC 30 V DC 30 V Current l i 130 ma 130 ma Power P i 800 mw 750/650/550 mw Effective internal capacitance C i 18.4 nf 18.4 nf Effective internal inductance L i 20 µh 20 µh Sensor circuit Parameters Model T15.x-AI Model T15.x-AC Ex ia IIC/IIB//IIA Ex ic IIC/IIB//IIA Ex ia IIIC Terminals 1-4 1-4 Voltage U o DC 30 V DC 30 V Strength of current I o 6.1 ma 6.1 ma Power P o 46 mw 46 mw Max. external IIC 30 nf 1) 180 nf 1) capacitance C o IIB IIIC 0.520 µf 1) 1.37 µf 1) IIA 1.70 µf 1) 5.40 µf 1) Max. external IIC 1 mh 2 mh inductance L o IIB IIIC 1 mh 2 mh Characteristics IIA 1 mh 2 mh Linear Due to distance requirements of the applied standards, the IS power and signal circuit and the IS sensor circuit shall be considered as being galvanically connected to each other. The intrinsically safe supply and signal circuit and the intrinsically safe sensor circuit must be considered as galvanically connected to each other (with regard to explosion protection). Ambient temperature range Application Ambient temperature range Temperature class Power P i Group II -40 C T a +85 C T4 800 mw -40 C T a +70 C T5 800 mw -40 C T a +55 C T6 800 mw Group IIIC -40 C T a +40 C N / A 750 mw -40 C T a +75 C N / A 650 mw -40 C T a +85 C N / A 550 mw N / A = not applicable 1) Internal L and C is already taken into account Comments: U o : Maximum voltage of any conductor against the other three conductors I o : Maximum output current for the least favourable connection of the internal current limiting resistors P o : U o x I o divided by 4 (linear characteristic) Page 6 of 10 WIKA data sheet TE 15.01 05/2016

Model T15.x-AN Power and signal circuit (4... 20 ma loop) Protection level Ex na IIC/IIB/IIA Parameters Model T15.x-AN Gas hazardous application Terminals + / - Voltage U i DC 35 V Current I i 21.5 ma Sensor circuit Protection level Ex na IIC/IIB/IIA Parameters Model T15.x-AN Terminals 1-4 Power P o 0.33 mw DC 3.3 V 0.1 ma Ambient temperature range Application Ambient temperature range Temperature class Group II -40 C T a +85 C T4-40 C T a +70 C T5-40 C T a +55 C T6 N / A = not applicable WIKA data sheet TE 15.01 05/2016 Page 7 of 10

Dimensions in mm Head mounting version, model T15.H Rail mounting version, model T15.R 99 17.5 7 22.5 22.5 33 44 113.6 99 17.5 2:1 The dimensions of the head-mounted transmitter match the form B DIN connection heads with extended mounting space, e.g. WIKA model BSS. The transmitters in rail mounting cases are suitable for all standard rails in accordance with IEC 60715. 113.6 Connecting PU-448 programming unit Head mounting version, model T15.H 2:1 Rail mounting version, model T15.R Attention: For direct communication via the serial interface of a PC/notebook, a model PU-448 programming unit is needed (see Accessories ). Page 8 of 10 WIKA data sheet TE 15.01 05/2016

Configuration software WIKAsoft-TT Accessories WIKA configuration software: free download from www.wika.com Model Version Order number Programming unit Simple operation 11606304 Model PU-448 LED status/diagnostic displays Compact design No further voltage supply is needed for either the programming unit or for the transmitter Incl. 1 model magwik magnetic quick connector Magnetic quick connector magwik Replacement for crocodile clips and HART terminals Fast, safe and tight electrical connection For all configuration and calibration processes 14026893 Adapter Suitable for TS 35 per DIN EN 60715 (DIN EN 50022) or TS 32 per DIN EN 50035 Material: Plastic / stainless steel Dimensions: 60 x 20 x 41.6 mm 3593789 WIKA data sheet TE 15.01 05/2016 Page 9 of 10

Approvals Logo Description Country EU declaration of conformity EMC directive EN 61326 emission (group 1, class B) and interference immunity (industrial application) ATEX directive (option) Hazardous areas European Community IECEx (option) Hazardous areas EAC (option) Electromagnetic compatibility Hazardous areas IECEx member states Eurasian Economic Community Certificates (option) 2.2 test report 3.1 inspection certificate Approvals and certificates, see website Ordering information Model / Explosion protection / Additional approvals / Permissible ambient temperature / Configuration / Certificates / Options 2015 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 10 of 10 WIKA data sheet TE 15.01 05/2016 05/2016 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de