DEMA SPRAY STATION II ASSEMBLY MODEL 606T-2 INSTALLATION INSTRUCTIONS

Similar documents
123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

123 Industrial Loop Road Paynesville, MN Phone:

123 Industrial Loop Road Paynesville, MN Phone:

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

KLE-115U Single Rack Undercounter Configuration Instruction Manual

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

Line to Refrigerator Ice/Water Dispenser

Equipped with AEM Dryflow Filter No Oil Required! INSTALLATION INSTRUCTIONS PART NUMBER DS BMW 335i 3.0L

Installation, Maintenance, & Repair Series 4000B/LF4000B

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

MODEL # Introduction

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

SunMaxx Solar Filling Station Operating Instructions

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Watts Pure Water Systems

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

VOYAGER 570G. 744A Sprayer Control

INSTANT HOT WATER RECIRCULATING SYSTEM

Foam Unit PROFOAM-R USER GUIDE

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

AIR LINE VALVES AND GAUGES

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OWNERS MANUAL. Model No GALLON "PRO" TOW SPRAYER

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

AIR OPERATED OIL PUMPS AND KITS

MODEL J SERIES CONVERTER

Your safety and the safety of others are very important.

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

Agri-Fab OWNERS MANUAL. Model No GALLON "PRO" TOW SPRAYER

MODEL G300 BRAKE BLEEDER

SINGLE STAGE INLINE FIRE PUMP

Assembly / Operation Instructions / Parts

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

ROUGHNECK II Pumpless Drain

Application Data Important Safety Information

MAC FAUCETS. Owner s Manual. Models: FA444

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Procenter Delivery System* Troubleshooting Charts

Installation Instructions S

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

Installation Operation Maintenance Troubleshooting

Generator Transfer Switch Model # HTS15-AUTO

Stainless Steel Single and Dual Circulation Kits

BERMAD Fire Protection

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Advantium 2 Plus Alarm

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Assembly and instructions

REPAIR AND MAINTENANCE MANUAL

BOWIE PUMPS OPERATION - MAINTENANCE

Float and Thermostatic Traps Series H, C and X

Installation Instructions

Dryaire Desiccant System

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Installation, Operation, Repair and Parts Manual

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+


55-Gallon Dispenser Package

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Unpacking, Installation, and Customization

Fixtures - Parts - Accessories to shampoo bowls

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09

Fluid Regulator. Instructions Parts List L LOW PRESSURE

ASSE APPROVAL. innovation > technology > future

PAINT SPRAY GUN WASHER

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

OP300S / OP350 2:1 RATIO TRANSFER PUMP

THE GIRAFFE HEAVY DUTY LINE

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

QT Residential Blower Metal Residential Blower

SAFETY SAFETY APPAREL 20,000 PSI

Operator s Manual. Pressure Injection Cell Model PC8500. Congratulations! Contents

FOAM CHAMBER MODEL - FC

CLEAN AND CLEAR PLUS CARTRIDGE FILTER

ATS Overhead Table Shelf System INSTRUCTION MANUAL

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

STABITHERM INSTALLATION & SERVICE BOOKLET

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

Transcription:

MODEL 0T-2 The 0T-2 Spray Station II Dispensers are used in any application where a chemical product must be sprayed or foamed without the use of compressed air or a high pressure pump. City water pressure and optional spray gun and foam wand attachments create the correct amount of pressure and foam for cleaning in food service applications such as supermarket meat rooms, deli areas and seafood departments. The 0T-2 is a two chemical product system that include an additional station for clear water rinsing. PVC manifold for hard water resistance Polypropylene injector for chemical resistance Polypropylene cover offers neat appearance Stainless steel back plate offers secure mounting and durability Large ball valve knobs for easy on/off action 1. PARTS CHECKLIST: ITEM DESCRIPTION QTY. A. Spray Station II Assembly 1 B. ¼ ID Tubing & Foot Strainer 2 C. Ceramic Weight 2 D. Metering Tip Kit 1 E. #10 Screw & Anchor Kit Set (Total: Screws & Anchors) 1 F. Label Card 1 2. INSTALLATION: Note: All installations must conform to local plumbing codes and use the approved backflow preventers. WARNING: Water supply should not exceed 12 psi and water temperature must not exceed 10 F. A. Mounting and Water Supply: Locate mounting holes on permanent vertical wall. Drill all holes into the drywall using a ¼ diameter bit for use with the included #10 screw and anchor set. (If mounting unit to wood and you do not plan to use the included anchors, drill 1/ holes.) Insert anchors into drilled holes and hammer them into the wall until they are flush with face of wall. Assemble the #10 screws with a phillip screwdriver into the anchors for the keyhole slots so the screw heads are sticking out of the wall approximately ½. Mount the unit by inserting the screw heads through the keyhole slots and tightening the screws. Secure the unit by inserting screws into the lower 2 holes and tightening the screws. The water inlet is equipped with a female garden hose fitting. The fitting may be removed to permit direct connection to / NPT pipe. B. Outlet Connection: Connect the discharge hose to the outlet garden hose fitting. NOTE: Be sure to clamp garden hose onto wall approximately 1 ft below the unit. (Clamp, Screws, & Anchors are supplied.) Spray guns, spray nozzles or foaming wands may be used on the hose outlet, note that the Spray Station II is designed to operate with nozzle flow rates not less than GPM total at 0 PSI. When a spray gun or nozzle is used, hose lengths must not exceed those shown in Table 1. Hoses, spray guns and foam wands are available through Dema. See the parts list on page under Optional Accessories for various styles. TABLE 1 Hose I.D. /" 1/2" /" Max. Length 1 ft. 0 ft. 100 ft. C. Chemical Supply: WARNING: USE CARE WHEN HANDLING HAZARDOUS CHEMICALS. Place the chemical container in a convenient location not more than six feet below the Spray Station II. (Greater lifts will reduce injection capabilities). The top of the container should not be above the Spray Station II. Cut the vinyl tubes to any convenient length that will allow the tubing to reach the bottom of the container. Drop the tubing ends with the strainers into the chemical containers. Push the other tubing ends over the chemical inlet barbs located on the sides of the unit. I-0 Pg. 1 of

MODEL 0T-2. FEED RATE ADJUSTMENT: The chemical feed rate is controlled by metering tips screwed into the hose barbs of the injectors on each side of the unit. The feed rates can be changed by using different sized metering tips. To select the proper sized metering tip for the desired dilution ratio, refer to Table 2. TABLE 2 METERING TIP SELECTION CHART FLUID DILUTION RATIOS WITH METERING TIP KIT (100-1K) Injection Rate for Viscosities Shown Metering Tip Color 1 cps cps 200 cps Oz/Gal Ratio Oz/Gal Ratio Oz/Gal Ratio Tan 0.0 20-1 0.2 12-1 0.20 0-1 Orange 0.0 2-1 0. -1 0.2 12-1 Turquoise 0.0 1-1 0.0 2-1 0. -1 Pink 0. 1-1 0. 1-1 0. 2-1 Clear 1.0-1 0.0 10-1 0. 2-1 Brown 1.0-1 0.0 12-1 0.0 21-1 Red 1.0-1 1.00 12-1 0.0 1-1 White 2.20-1 1.0-1 0.0 10-1 Green 2.0-1 1.0-1 0.0 12-1 Blue.20 0-1 1. -1 1.00 12-1 Yellow. 2-1 2.2-1 1.10 11-1 Black.0 20-1 2.0-1 1.1 111-1 Purple.20 1-1 2.0-1 1.20 10-1 Gray 10.0 12-1 2. -1 1.2 102-1 No Tip 12.0 10-1.0-1 1. -1 All injection ratios are based on 0 PSI inlet water pressure and a water flow rate of 2. GPM. Note: Leaner dilutions are available using DEMA metering tip kit #100-1KU or capillary tip #-1P. OPERATION: The Spray Station II permits the operator to select one of two chemicals or clear water rinse by opening and closing the appropriate valve. Only one valve should be opened at any time. If two valves are opened simultaneously, the injector will not induct chemical. When using a spray gun or foaming wand make sure that the gun on the end of the hose is in the full open position when inducting chemical.. SERVICING: CAUTION: TURN OFF WATER SUPPLY BEFORE SERVICING. A. If unit fails to draw chemical: 1. Is more than one valve open? 2. Is the hose too long? (See Table 1). Is the gun or nozzle(s) sized properly? (Refer to Section 2 B). Remove gun and/or nozzle(s) and turn on water. If the injector inducts chemical, the gun and nozzle(s) are improperly sized.. Is the metering tip blocked? Remove tip and clear blockage.. Is the hose kinked or otherwise obstructed?. Is the spray gun fully open? I-0 Pg. 2 of

B. If unit stops drawing chemical: DEMA SPRAY STATION II ASSEMBLY MODEL 0T-2 1. Is the foot strainer clogged? Lift from drum and clean. 2. Are the spray nozzle(s) partially clogged? Remove and clean.. Is the metering tip blocked? Remove and clean.. Is the injector check valve clogged? Unscrew the four cover screws to take the Spray Station II unit off the wall. Remove the three ball valve handles to separate the cover from the manifold. Remove the square, plastic metering knobs to inspect the check valve ball, spring and O-ring. CAUTION: WHEN SERVICING UNIT BE SURE THAT REPLACEMENT PARTS HAVE BEEN INSTALLED ACCORDING TO DRAWING. BE CERTAIN CHECK VALVE PARTS ARE IN PLACE. RETURNS: WARRANTY: NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT DEMA S WRITTEN PERMISSION. RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN ADVANCE OF RETURN. DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products, which have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse, or misapplication. Rubber and synthetic rubber parts such as o - rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty will be void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number, to return units for repair or replacement, must be granted in advance of return. I-0 Pg. of

MODEL 0T-2 Water Inlet Chemical Valve #1 Metering Tip Location Chemical Valve #2 Keyhole Slot (2 Places) Back Plate Metering Tip Location Mounting Holes (2 Places) Clear Rinse Water\Chemical Solution Outlet (Garden Hose Connection) Clear Vinyl Suction Tube With Foot Strainer Clear Vinyl Suction Tube With Foot Strainer I-0 Pg. of

MODEL 0T-2 1 2 11 See Page for injector breakdown 12 1 10 OPTIONAL ACCESSORIES INLET 1 1 1 1 1 1 20 VENT QTY. PART NO. DESCRIPTION 1-2-2 Water Inlet 2 --1 Top Manifold --1 P20CTC Valve Knob Handle Injector --1 0--1-1 --1 Bottom Manifold O-Ring (EP) Pipe Plug & O-Ring Assy. Pipe Adapter 10 11 --1-1-1 100-12 Adapter Outlet Fitting Vinyl Tubing 1/ ID X ' Lg. 12 1 1-10-2 2-11MP Ceramic Weight Foot Strainer QTY. PART NO. 1 22QD 1 1 0-1QD 0-1HD 1-1 -RG 1 -W 20 - OPTIONAL ACCESSORIES DESCRIPTION FOAM WAND W/ DISCONNECT HEAVY DUTY SPRAY GUN W/ DISCONNECT HEAVY DUTY SPRAY GUN HOSE (BLACK) 2' X 1/2 ID HOSE (RED) SPRING GARD 2' X 1/2 ID HOSE (WHITE) 2' X 1/2 ID BACKFLOW PREVENTER (A.S.S.E. 1012) I-0 Pg. of

MODEL 0T-2 P20CTC INJECTOR BREAKDOWN 1 2 P20CTC NO. 1 2 PART NO. 2-100-1-2-2-SP 2-2S 2-2P 2-2-2 2-- 2-2S DESCRIPTION Screw (Req'd ) Metering Tip (Specify Color) Check Valve Repair Kit O-Ring Check Valve Ball Check Valve Spring Check Valve Core O-Ring NO. PART NO. 100-1K ACCESSORIES DESCRIPTION Metering Tip Kit I-0 Pg. of