Ultrasonic Flowmeter Range

Similar documents
How To Use A Flowmeter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Turbine Flowmeter Vision 1000 Flowrates 0,1-2,5L/min. Turbine Flowmeter Vision 2000 Flowrates 0,5-35L/min

Turbine Flow Sensor Series VTR

For Multi-Parameter Meters see mvx

ELECTROMAGNETIC FLOWMETER COMPACT

Mass Flow Meters & Controllers

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Centro-Matic Automatic Lubrication Systems System Controls

Typical Aluminum GFM Mass Flow Meter

Electromagnetic Flow Meter

Series DFMT Digital Paddlewheel Flowmeter

COMBIMASS. Technical Data COMBIMASS eco-bio +

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Flow switches Series AD/VH

Plastic tube flowmeters Series PT/PS

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Model 111 Mass Flow Instruments

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Thermal Flow Sensor Die

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Precision Mass Flow Meters / Controllers for Liquids and Gases

Custody Transfer Measurement. with the V-Cone Flowmeter

Innovation for cost reduction in pneumatics. Leakage monitoring. Measurement of compressed air consumption.

TELEDYNE HASTINGS INSTRUMENTS

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

How To Use A Ds340 (Dsp)

Duct Humidity Transmitter

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

crm+25/d/tc/e Extract from our online catalogue: Current to:

Conductive Level Switch FK 2 Technical Data:

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

The Do s and Don ts of Pressure Transducers

Power consumption (kw)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Digital inductive conductivity transmitter

TMS TANK MANAGEMENT SYSTEM

PRODUCT PROFILE FEATURES

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Features. Picture. Specifications

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Inductive Proximity Sensors

SITRANS F flowmeters SITRANS F M

Models SFP33 & SFP32 Pressure Transmitters

Vacuum drying oven for non-flammable solvents

Sanitary Type Electronic Flow Switches

The Unique Accelabar Flow Meter

Various Technics of Liquids and Solids Level Measurements. (Part 3)

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Variable V Area Flowmeter Rotameter The Original

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Transmitter Interface Program

Cooling Channel Optimization

USB-500 Series Low-Cost Data Loggers and Accessories

O C M III. Open Channel Flow Monitor

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Excellence through Versatility

Smart Sensing Solutions Since 1954

Using meters to measure steam flow

OEM-EP Pressure Controllers

RAINCONTROL LCD Special

photoelectric highlights

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Instruction Manual. T3111 T3111L T3111P T3111Ex

4 Posiflow Proportional Solenoid Valves

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

S300 Series Dust Monitors

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

EVAL-UFDC-1/UFDC-1M-16

Thermal Mass Flow Meter (Series MST)

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Relative and absolute pressure switch type 529

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

9000 Series Accelerometers Specifications

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Transcription:

TM B r e a k t hr ough F l owmeter Technology Ultrasonic Flowmeter Range

IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot plant Fuel cells Pharmaceutical Chemical & petrochemical Model 760 TM

The Titan pedigree With over 40 years experience in flowmeter innovation and manufacture, Titan s company philosophy of pushing the envelope by trying to do things a little different and better has resulted in sales of over 500,000 products into 50 countries worldwide and a repeat purchase percentage of 95% something which Company founder Trevor Forster is justly proud of. Today Titan supplies innovative flow measurement solutions into a broad range of sectors, including medical, industrial, food & drink, laboratory and pharmaceutical. Its latest innovation, the Atrato flowmeter range, is set to challenge conventional flowmeter thinking the world over. The culmination of eight years research and development in collaboration with the Department of Process & Engineering at Cranfield University, it can handle low flows from laminar to turbulent and is largely immune from viscosity. It has excellent turndown, repeatability and linearity and can monitor flow over a range of 200:1. Accuracy is better than +/-1.0%. FEATURES Choice of materials ±1.0% of reading ±0.1% repeatability 4 Flow ranges Pulse output USB interface 10/30 Bar rating Viton seals as std. Choice of end fittings 10-24 Vdc 60 C or 110 C Max Flow switch Rate & total option 200:1 turndown Non metallic options Analogue outputs The Atrato Flowmeter range Utilising patented technology that enables it to operate with excellent accuracy over very wide flow ranges, across the whole span, the Atrato range of inline flowmeters is a genuine breakthrough in flowmeter technology. Its rugged, clean bore construction makes the Atrato ideal for a whole range of low flow applications and its USB port allows software connectivity at literally the touch of a button. Its signal processing system permits flow measurement across the whole Reynolds number range allowing both viscous and non-viscous products to be metered accurately.

Atrato is a genuine step change in flowmeter technology TM

A powerful measuring system The time of flight measuring system measures both the upstream and downstream flight times and half the difference is the velocity of the fluid. Our patented system measures these time differences to an accuracy of better than 250 picoseconds giving our excellent meter performance. As the pipe geometry is known the resulting pulse output is accurate for the volume passed. This performance is further enhanced by our primary signal to noise ratio which is typically 2000:1 and at times as high as 3000:1. BENEFITS High reliability No moving parts Fast response Through bore design Easy to use OEM versions Computer interface The USB connection permits the user to directly monitor the rate and total on their laptop as well as altering some of the operating parameters such as the pulse resolution and units. If the rate and total or the analogue boards are used their programming and operation can be accessed directly. Inquire for details of data logging and operational statistical output possibilities. Heritage The development of the Atrato began in 2001 with a corporate decision to develop the best noninvasive small bore flow meter in the world as part of a long term strategic plan. One of the foremost fluid engineering establishments (The Cranfield Institute of Technology) was commissioned to develop the device along with Titan and this joint project has been continuous since that date. Titan have exclusive global rights for the technology which is subject to two granted patents and two more applications will be made in the near future.

TM Order Codes Flow range 710 2-500 ml/min 720 0.01-1.7 L/min 740 0.02-5 L/min 760 0.1-20 L/min O Ring material V Viton End fittings Body material Electronics N Nitrile E EPDM S Silicon 0 3/8 John Guest 10 bar 1 1/2 BSP PEEK 10 bar 2 1/2 NPT 316 St St 30 bar 3 1/2 BSP 316 St St 30 bar 0 PEEK / 316 St St 1 PEEK / Borosilicate glass Standard Materials of Construction Body and tube PEEK / St St O Ring seal Viton Output Pulse End fittings 1/2 BSP A Analogue output D Display & analogue output RA 110 C Sensor remote electronics analogue output RD 110 C Sensor remote electronics display & analogue output E.G. 760 V 0 0 A is a flow range of 0.1 to 20 L/Min, Viton seal, 3/8 John Guest fitting, PEEK body with 316 stainless steel tube flowmeter with a 4-20mA analogue output.

How it works The Atrato system uses the well proven time of flight measuring method which is far more reliable and accurate than Doppler shift measurement where reflected signals are required from irregularities in the liquid. The Atrato crystals are plain disks with a hole in the centre forming a washer, which are excited in such a way that they oscillate radially as opposed to the normal mode of excitement which is across the thickness of the ceramic. This strong radial signal sends symmetrical pulses directly into the tube. Because of these annular ring crystals the sound travelling down the liquid can be considered as a plain wave. The signal to noise ratio is remarkable as there is little background noise and high signal strengths. At times the signal to noise ratio is as high as 3000:1. As the system is fully balanced at zero flows the two signals are identical and cancel each other out. This gives a very stable zero flow condition and is the basis of the Atrato s high ratio between minimum and maximum flows. As the flow increases these signals go out of phase and we measure this phase shift to an accuracy equivalent to 250 picoseconds. In addition, the sound waves travelling down the tube in the Atrato operating system are symmetrical and as a result any changes in the fluid s velocity profile across the pipe diameter will be averaged out by the signal as it passes from the transmitter to the receiver. It is therefore irrelevant whether the fluid velocity profile is fully formed with turbulent flow or completely laminar with a classic parabolic profile. In practice this gives the Atrato an excellent immunity to Reynolds number changes and a good high viscosity performance. Model Flow Range Linearity & Maximum Pulses per litre L/Min reading frequency Hz (full flow) 710 0.002 0.5 1.5 400 10000 720 0.07 1.7 1.0 400 10000 740 0.02 5.0 1.5 400 4000 760 0.1 20.0 1.5 400 1000

TM Technical Specifications Linearity ±1.0% of reading over flow range Repeatability ±0.1% from 25% to 100% ±0.5% from 0 to 25% Housing Temperature range or Fluid temperature range IP54 Storage temperature -20 to 110 C Pressure rating Pulse output Relay PIN 6 Transistor output input PIN 7 Transistor output LCD display input -10 to 60 C assembly with enclosed electronics -10 to 110 C sensor only (for use with remote electronics) -10 to 60 C remote electronics -10 to 60 C or -10 to 110 C with remote electronics 10 bar standard, 30 bar with stainless steel end fittings PNP or NPN maximum frequency 400 Hz 24 Vdc 500mA max non inductive PNP 24 V @ 20mA maximum Pull down resistor required (10K ohm) NPN 24 V @ 20mA maximum Pull up resistor required (10K ohm) Reflective 6 x 8mm high main characters 2.5mm enunciators Gal. cc. Kg. gms. Ltr. /min /Hr /Sec 4 20mA output into 250 ohm maximum 14 bit resolution ±0.1% linearity (plus flowmeter accuracy) 0 10 Volt output 14 bit resolution (14 V dc min supply voltage) ±0.1% linearity (plus flowmeter accuracy) 0 5 Volt output 12 bit resolution USB Wiring terminals TypeA connector Windows XP or later 1mm maximum Power supply 10 24 Vdc (14-24 Vdc for 4-20mA or 0-10 V) Power consumption Connections Wetted materials 110mA (plus analogue output current) 1/2 BSP male PEEK or 1/2 NPT or BSP 316 stainless steel. 3/8 John Guest push-in Peek, 316 stainless steel, Borosilicate glass Choice of elastomers Distributed by: TITAN ENTERPRISES LTD. Coldharbour Business Park, Sherborne, Dorset DT9 4JW Phone: +44 (0)1935 812790 Fax: +44 (0)1935 812890 Email: sales@atratoflowmeters.com www.atratoflowmeters.com Telf.: 96 816 2005-96 111 3302 Mail: comercial@sensovant.com Web: www.sensovant.com