CG100 Series. Corrosion Thickness Gauges

Similar documents
Viscosity - Flow Cups. elcometer.com

Elcometer Viscosity Cups (AFNOR, BS, DIN, FORD, ISO)

Ultrasonic Load Monitoring

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

Ultrasonic Wave Propagation Review

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Scanning Acoustic Microscopy Training

US-SPI New generation of High performances Ultrasonic device

Microwave Meter. Instruction Manual

PRODUCT PROFILE FEATURES

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

US-Key New generation of High performances Ultrasonic device

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

Instruction Manual Service Program ULTRA-PROG-IR

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Gage Applied Technologies

How To Use A Ds340 (Dsp)

Measuring electric and magnetic fields

O C M III. Open Channel Flow Monitor

Datalogger DL/N 70 Version:

DM4E DM4 DM4 DL. Operating Manual

USB-500/600 Series Low-Cost Data Loggers and Accessories

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated testing of square and round bars

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

How To Use A Sound Card With A Subsonic Sound Card

Wahl C50 Calibrator FEATURES

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Replacing Displacers with Guided Wave Radar

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Paint Test Equipment. Stargloss Gloss Meter Data Sheet

SEMICONDUCTOR TECHNICAL DATA

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

TI GPS PPS Timing Application Note

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

E190Q Lecture 5 Autonomous Robot Navigation

Multifunction devices

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

Navi-Radar 4000 and Navi-Sailor 4000 ECS for workboats and small crafts BIG SOLUTIONS FOR SMALL VESSELS

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

RF Measurements Using a Modular Digitizer

Agilent E5100A Network Analyzer

Series DFMT Digital Paddlewheel Flowmeter

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Impact Echo Scanning Technology for Internal Grout Condition Evaluation in Post-Tensioned Bridge Ducts

Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Agilent 8762/3/4A,B,C Coaxial Switches

PORTABLE FLOW METER KITS TDS-100H

crm+25/d/tc/e Extract from our online catalogue: Current to:

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SOUND LEVEL METER 94405

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

5X, Mark 5X, Mark 5X Pro & Elite 4X

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

Non-destructive testing Ð Ultrasonic examination

Physical Specifications (Custom design available.)

T Substation Maintenance and Commissioning Test Equipment

Op Amp Circuit Collection

HDO700 P FIBRE OPTIC TRANSMITTER

Agilent 4338B Milliohm Meter

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Agilent 4339B/4349B High Resistance Meters

Encoded Phased Array Bridge Pin Inspection

CISPR 17 Measurements

Frequency selective monitoring and logging of environmental electromagnetic fields

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Type-D EEG System for Regular EEG Clinic

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

NON-DESTRUCTIVE TESTING OF PIPELINES. L. Annila. Abstract

Wide format scanning reformatted Small Light Easy to use Portable Self-contained

PORTAFLOW 300. Ultrasonic Flowmeter Manual

Low Frequency Velocity Sensor

Description of OPCARD 01/100. Single Channel PCI-bus Ultrasonic PR Card Ultrasonic card with integrated pulser and receiver

Wireless Data Logger Monitoring Systems

ELECRAFT KX3 EXTENDED VFO TEMPERATURE COMPENSATION PROCEDURE Copyright 2012 Elecraft LLC Rev. A8, October 27, 2012

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

HOOK-X Series. Operation manual. lowrance.com ENGLISH. HOOK-4x HOOK-5x HOOK-7x

USB-500 Series Low-Cost Data Loggers and Accessories

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Product Information Sheet UH28CS-12kV Hi Pot Tester

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Unmatched Metal Hardness Testing

PXI. GSM/EDGE Measurement Suite

1. SAFETY INFORMATION

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Handbook on the Ultrasonic Examination. Austenitic Welds

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

User's Guide. Integrating Sound Level Datalogger. Model Introduction

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

Transcription:

CG100 Series 1 Corrosion Thickness Gauges

CG100B, CG100BDL, CG100ABDL & CG100ABDL+ The most advanced in the Elcometer NDT range, these easy to use corrosion gauges provide inspectors with all the features necessary to accurately measure the material and coating thickness at the same time. Offering a full range of measurement modes including: Pulse-Echo Temp Comp Mode (PETP) and Coating Only Mode (CT) to Pulse-Echo Coating Mode (PECT), the CG100 range allows the inspector to choose the right tool for the job. Featuring automatic gain control (AGC) for ease of use or manual adjustment (-30dB to 70dB) to increase the amplitude of the received echo to suit the material properties, the CG100 series are ideal gauges for all applications. The time corrected gain (TCG) feature automatically compensates for sound attenuation through a material, further increasing the performance of the gauge. Built-in Gates allow users to set the measurement parameters either on or between waveforms, bypassing any surface echoes or noise from the material. Threshold adjustment allows users to adjust the sensitivity of the gauge to detect signals with lower amplitudes. The CG100BDL, CG100ABDL & CG100ABDL+ stores up to 16,000 readings with individual waveforms in alpha numeric batches with full data logging via RS232 data output to Elcometer NDT data management software. With its high contrasting colour display the CG100ABDL+ has a refresh rate of 120Hz providing users with an instant measurement response. 2

Thickness Gauges Advantages Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT) Adjustable gain: -30dB to 70dB range Automatic gain control (AGC) Time corrected gain (TCG) Gate control Threshold adjustment 64 User defined setups Multiple language display Multiple calibration and material selection options High speed scan mode: 32 readings per second Differential and minimal thickness alarm modes Data storage capability: 16,000 readings and waveforms or B-Scans Download to Data management software 3

CG100B, CG100BDL, CG100ABDL & CG100ABDL+ Model & Part Number CG100B CG100BDL Display Mode: Material thickness digits display B-Scan cross sectional display Combined B-Scan and digits display Scan bar display Coating thickness display A-Scan display Measurement Mode¹ Measurement Rate Manual: Scan mode Scan bar display PE, PETP (Temp Compensation), EE (ThruPaint ), EEV, CT (Coating) & PECT 4 readings per second 50 readings per second 6 readings per second PE, PETP (Temp Compensation), EE (ThruPaint ), EEV, CT (Coating) & PECT 4 readings per second 50 readings per second 6 readings per second PE: 0.63-508mm (0.025-19.999 inches) PETP: 0.63-508mm (0.025-19.999 inches) EE: 2.54-102mm (0.100-4.000 inches) EEV: 1.27-25.4mm (0.050-1.000 inches) CT: 0.01-2.54mm (0.001-0.100 inches) PECT: 0.63-508mm (0.025-19.999 inches) PECT: 0.01-2.54mm (0.001-0.100 inches) Measuring Range² PE: 0.63-508mm (0.025-19.999 inches) PETP: 0.63-508mm (0.025-19.999 inches) EE: 2.54-102mm (0.100-4.000 inches) EEV: 1.27-25.4mm (0.050-1.000 inches) CT: 0.01-2.54mm (0.001-0.100 inches) PECT: 0.63-508mm (0.025-19.999 inches) PECT: 0.01-2.54mm (0.001-0.100 inches) Measurement Accuracy² ±0.01mm (±0.001 inches) ±0.01mm (±0.001 inches) Measurement Resolution 0.01mm (0.001 inches) 0.01mm (0.001 inches) Velocity Calibration Range 1250-13,995m/s (0.0492-0.5510in/ms) 1250-13,995m/s (0.0492-0.5510in/ms) Additional Features:³ High speed scan mode Differential mode Limit alarm mode B-Scan display speed 15 seconds per screen 15 seconds per screen Flaw Mode Calibration Setups Gates 6 factory & 64 user-definable setups transferrable to and from a PC archive 6 factory & 64 user-definable setups transferrable to and from a PC archive Damping Pulser Type dual square wave pulsers up to 140Hz pulse repetition rate dual square wave pulsers up to 140Hz pulse repetition rate Gain Timing time corrected gain (TCG), automatic gain control (AGC) with 110dB range (limited), or selectable gain: vlow, low, medium hi or vhi precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer time corrected gain (TCG), automatic gain control (AGC) with 110dB range (limited), or selectable gain: vlow, low, medium hi or vhi precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer PE Pulse - Echo Mode The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection. PETP Pulse - Echo Temp Comp Mode Similar to the PE mode, PETP takes into account and compensates for the variations in measurement caused by temperature variations. 4

Specifications CG100ABDL CG100ABDL+ Model & Part Number + Rectified, - Rectified, Full Waveform (RF) PE, PETP (Temp Compensation), EE (ThruPaint ), EEV, CT (Coating) & PECT 4 readings per second 50 readings per second 6 readings per second PE: 0.63-508mm (0.025-19.999 inches) PETP: 0.63-508mm (0.025-19.999 inches) EE: 1.27-102mm (0.050-4.000 inches) EEV: 1.27-25.4mm (0.050-1.000 inches) CT: 0.01-2.54mm (0.001-0.100 inches) PECT: 0.63-508mm (0.025-19.999 inches) PECT: 0.01-2.54mm (0.001-0.100 inches) + Rectified, - Rectified, Full Waveform (RF) PE, PETP (Temp Compensation), EE (ThruPaint ), EEV, CT (Coating) & PECT 4 readings per second 32 readings per second 6 readings per second PE: 0.63-508mm (0.025-19.999 inches) PETP: 0.63-508mm (0.025-19.999 inches) EE: 1.27-102mm (0.050-4.000 inches) EEV: 1.27-25.4mm (0.050-1.000 inches) CT: 0.01-2.54mm (0.001-0.100 inches) PECT: 0.63-508mm (0.025-19.999 inches) PECT: 0.01-2.54mm (0.001-0.100 inches) Display Mode: Material thickness digits display B-Scan cross sectional display Combined B-Scan and digits display Scan bar display Coating thickness display A-Scan display Measurement Mode¹ Measurement Rate Manual: Scan mode Scan bar display Measuring Range² ±0.01mm (±0.001 inches) ±0.01mm (±0.001 inches) Measurement Accuracy² 0.01mm (0.001 inches) 0.01mm (0.001 inches) Measurement Resolution 1250-13,995m/s (0.0492-0.5510in/ms) 1250-9,999m/s (0.0492-0.3936in/ms) Velocity Calibration Range Additional Features:³ High speed scan mode Differential mode Limit alarm mode adjustable display speed adjustable display speed B-Scan display speed Basic prove-up flaw detection using Basic prove-up flaw detection using Flaw Mode single element angle beam transducers single element angle beam transducers 6 factory & 64 user-definable setups transferrable to and from a PC archive 3 fully adjustable gates: start, stop, width & threshold dual 200 volt square wave pulsers with adjustable pulse width (spike, thin, wide) and 50 volt cut/boost for greater penetration manual, automatic gain control (AGC) with 110dB range (limited), time corrected gain (TCG) precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer 6 factory & 64 user-definable setups transferrable to and from a PC archive 3 fully adjustable gates: start, stop, width & threshold adjustable; impedance matching for optimising transducer performance dual 200 volt square wave pulsers with adjustable pulse width (spike, thin, wide) and 50 volt cut/boost for greater penetration manual, automatic gain control (AGC) with 110dB range (limited), time corrected gain (TCG) precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer Calibration Setups Gates Damping Pulser Type Gain Timing EE Echo - Echo Mode Also known as the ThruPaint Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary. EEV Echo - Echo Verify Mode The echo-echo verify mode measures by comparing the values between 3 reflections and is commonly used to eliminate errors from surface coatings and to make measurements in multiple layered materials. ¹ PE: Pulse-Echo Mode, PETP: Pulse-Echo Temperature Compensation Mode, EE: Echo-Echo (ThruPaint ) Mode, EEV: Echo-Echo Verify, CT: Coating Thickness Mode, PECT: Pulse-Echo, Coating Thickness Mode; See page 3 for further information ² Measuring range & accuracy depends on material, surface conditions and the transducer selected ³ See page 5 for a full explanation of the features 5

CG100B, CG100BDL, CG100ABDL & CG100ABDL+ Model & Part Number CG100B CG100BDL Data logging 16,000 with B-scan image & gauge settings 210,000 - coating, material, min, max thickness sequential and grid logging Alpha numeric batch identification OBSTRUCT indicates inaccessible locations Calibration Options single, two point, velocity & material type single, two point, velocity & material type Transducer Probe Type dual element dual element Transducer Frequency Range 1-10MHz 1-10MHz Transducer Recognition automatic & manual - selectable from a list automatic & manual - selectable from a list V-path / dual path error correction automatic automatic Probe Zero automatic & manual (via integrated probe disk) automatic & manual (via integrated probe disk) Display 1/8 VGA (grayscale) 62 x 45.7mm (2.4 x 1.8 inches) viewable area 1/8 VGA (grayscale) 62 x 45.7mm (2.4 x 1.8 inches) viewable area Display Refresh Rate 25Hz 25Hz Units (selectable) mm or inches mm or inches Backlight on / off / auto on / off / auto Repeatability / Stability Indicator Battery Type 3 x AA alkaline 3 x AA alkaline Battery Life (approximate) 150 hours 150 hours Low Battery Indicator Battery Save Mode auto auto Operating Temperature -10 to 60ºC (14 to 140ºF) -10 to 60ºC (14 to 140ºF) Size (w x h x d) 63.5 x 165.0 x 31.5mm (2.5 x 6.5 x 1.24 inches) 63.5 x 165.0 x 31.5mm (2.5 x 6.5 x 1.24 inches) Weight (including batteries) 383g (13.5oz) 383g (13.5oz) Aluminium case design with gasket sealed end caps, waterproof membrane keypad Transducer Connector Type LEMO LEMO RS232 Interface Bi-directional Bi-directional Packing List Elcometer NDT CG100B gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries Elcometer NDT CG100BDL gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries, software, transfer cable CT Coating Only Mode Displays the thickness of the coating applied to the material. PECT Pulse - Echo Coating Mode Displays both the material thickness (PE) and the coating thickness (CT) at the same time. 6

Specifications (continued) CG100ABDL CG100ABDL+ Model & Part Number 16,000 with A/B-scan image & gauge settings 8,000 with A/B-scan image & gauge settings Data logging 210,000 - coating, material, min, max thickness 210,000 - coating, material, min, max thickness sequential and grid logging sequential and grid logging Alpha numeric batch identification Alpha numeric batch identification OBSTRUCT indicates inaccessible locations OBSTRUCT indicates inaccessible locations single, two point, velocity & material type single, two point, velocity & material type Calibration Options dual element & flaw prove up dual element & flaw prove up Transducer Probe Type 1-10MHz 1-10MHz Transducer Frequency Range automatic & manual - selectable from a list automatic & manual - selectable from a list Transducer Recognition automatic automatic V-path / dual path error correction automatic & manual (via integrated probe disk) automatic & manual (via integrated probe disk) Probe Zero 1/8 VGA (grayscale) 62 x 45.7mm (2.4 x 1.8 inches) viewable area 1/4 VGA AMOLED colour display 57.6 x 43.2mm (2.27 x 1.78 inches) viewable area Display 25Hz 120Hz Display Refresh Rate mm or inches mm or inches Units (selectable) on / off / auto adjustable brightness Backlight Repeatability / Stability Indicator 3 x AA alkaline 3 x AA alkaline Battery Type 50 hours 25 hours Battery Life (approximate) Low Battery Indicator auto auto Battery Save Mode -10 to 60ºC (14 to 140ºF) -10 to 60ºC (14 to 140ºF) Operating Temperature 63.5 x 165.0 x 31.5mm (2.5 x 6.5 x 1.24 inches) 63.5 x 165.0 x 31.5mm (2.5 x 6.5 x 1.24 inches) Size (w x h x d) 383g (13.5oz) 383g (13.5oz) Weight (including batteries) Aluminium case design with gasket sealed end caps, waterproof membrane keypad LEMO LEMO Transducer Connector Type Bi-directional Bi-directional RS232 Interface Elcometer NDT CG100ABDL gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries, software, transfer cable Elcometer NDT CG100ABDL+ gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries, software, transfer cable Packing List TCG Time Corrected Gain Time corrected gain increases gain as time increases, in order to achieve an over all level of sensitivity for the same flaw/reflector at different distances. FLAW MODE Basic Flaw Mode Basic prove-up flaw detection using single element angle beam transducers is available on the CG100ABDL and CG100ABDL+ corrosion thickness gauges. ¹ PE: Pulse-Echo Mode, PETP: Pulse-Echo Temperature Compensation Mode, EE: Echo-Echo (ThruPaint ) Mode, EEV: Echo-Echo Verify, CT: Coating Thickness Mode, PECT: Pulse-Echo, Coating Thickness Mode; See page 3 for further information ² Measuring range & accuracy depends on material, surface conditions and the transducer selected ³ See page 5 for a full explanation of the features 7

Corrosion Gauges Precision Gauges Flaw Detection Velocity Gauges Sonic Gauges Bolt Gauges ENGLAND Elcometer Limited Manchester M43 6BU Tel: +44 (0)161 371 6000 Fax: +44 (0)161 371 6010 e-mail: sales@elcometer.com USA Elcometer Inc Rochester Hills Michigan 48309 Tel: +1 248 650 0500 Toll Free: 800 521 0635 Fax: +1 248 650 0501 e-mail: inc@elcometer.com REPUBLIC OF SINGAPORE Elcometer (Asia) Pte Ltd Singapore 589472, Tel: +65 6462 2822 Fax: +65 6462 2860 e-mail: asia@elcometer.com JAPAN Elcometer KK Minato-ku, Tokyo Tel: +81 (0)3-4530-9714 Fax: +81 (0)3-4530-9713 e-mail: jp_info@elcometer.com FRANCE Elcometer Sarl 45430 BOU Tel: +33 (0)2 38 86 33 44 Fax: +33 (0)2 38 91 37 66 e-mail: fr_info@elcometer.com 8 GERMANY Elcometer Instruments GmbH D-73431 Aalen Tel: +49(0)7361 52806 0 Fax: +49(0)7361 52806 77 e-mail: de_info@elcometer.de BELGIUM Elcometer SA B-4681 Hermalle /s Argenteau Tel: +32 (0)4 379 96 10 Fax: +32 (0)4 374 06 03 e-mail: be_info@elcometer.com THE NETHERLANDS Elcometer NL 3584 BH Utrecht Tel: +31 (0)30 210.7005 Fax: +31 (0)30 210.6666 email: nl_info@elcometer.com Elcometer Limited, 2011. SLI0054 Issue 1 All rights reserved. No part of this document may be reproduced, transmitted, stored (in a retrieval system or otherwise), or translated into any language, in any form, or by any means, without the prior written permission of Elcometer Limited. Elcometer is a registered trademark of Elcometer Limited. ThruPaint is a trademark of Elcometer Limited. All other trademarks are acknowledged. Due to our policy of continuous improvement, Elcometer Limited reserves the right to change specifications without notice.