H 4135A: Relay in Terminal Housing

Similar documents
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Redundancy Module QUINT-DIODE/40

Inductive sensor NI10-M18-Y1X-H1141

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RM4TG20 three-phase network control relay RM4-T - range V

Contact expander modules

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RY2 miniature industrial relays

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Contact expansion modules

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

E-STOP relays, safety gate monitors

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

PHOENIX CONTACT Features

Three-phase monitoring relay CM-PFE

49 Series - Relay interface modules A. Features

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Pluggable interface relays CR-P Pcb relays

38 Series - Relay interface modules A

Product Catalogue. Relays with forcibly guided contacts

SMS 4 / SMS 5 safety mat Product information

CONFIGURABLE SAFETY RELAYS

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

CompactLogix Power Supplies Specifications

Control and Distribution Boxes made of Stainless Steel Series 8150

PNOZsigma - Base units

E-STOP relays, safety gate monitors

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

SPST-NO SPDT DPST-NO DPDT

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Safety technique. Emergency stop module BO 5988 safemaster

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

38 Series - Relay interface modules A

Inductive slot sensor

Safety Manual BT50(T) Safety relay / Expansion relay

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Electro-pneumatic control valves

MINI MCR-SL-R-UI(-SP)

Technical Data. Dimensions

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Control Devices Catalogue. Control Devices. Preferred and Standard Products

48 SERIES Relay interface modules 10 A

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Technical Data. Dimensions

Linear Luminaire with LED Series EXLUX 6402/2

5SV Residual Current Protective Devices

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Thermistor motor protection

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Type: DILM9 10(24VDC) Article No.:

Explosion proof enclosures

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Operating Manual UWAPS-TINY Series

Type: DILM32 10(24V50HZ) Article No.:

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Electronic overload relay EF19 and EF45

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Power Supplies 3. SDN-P DIN Rail Series

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

2.12. page Products for Explosion hazardous Environment

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

CONFIGURABLE SAFETY RELAYS

Solenoid Valve Island Type 3965

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Type: DILM50(230V50HZ,240V60HZ) Article No.:

E-STOP relays, safety gate monitors

Operating Instructions

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

ACS-30-EU-EMDR-10-MOD

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Safety automation solutions

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Transcription:

H 4135A HI 803 003 E (1647) H 4135A: Relay in Terminal Housing safety-related, for circuits up to SIL 3 in accordance with IEC 61508 F1: max. 4 A (time-lag), delivery condition: 4 A (time-lag) Figure 1: Block Diagram The module is tested in accordance with: IEC 61508, Part 1-7:2010 IEC 61511:2016 EN 50156-1:2015 EN 60664-1:2007 EN 50178:1997 VDE 0160 EN 298:2012 NFPA 85:2015 NFPA 86:2015 The device may be used in environments meeting the requirements of the following standards: EN 61000-6-2:2005 EN 61000-6-7:2015 EN 61326-3-1:2008 EN 61326-3-2:2008 The device is suitable for switching safety-related circuits. The device thus be used for safety shutdowns, e.g., for shutting down the entire fuel supply in combustion plants. All rights reserved. Equipment subject to change without notice. Page 1 of 6 HIMA Paul Hildebrandt GmbH, P.O. Box 1261, 68777 Brühl English translation of the German original document:

HI 803 003 E (1647) H 4135A i The module is equipped with diverse relays. Terminal 8 may only be used for monitoring the F1 fuse and must not be used for supplying a voltage! Input voltage 24 VDC, -15...+20 % Current consumption 40 ma Output Potential-free make contact Relay data: see below Switching time approx. 8 ms Reset time approx. 6 ms Ambient temperature -25...+60 C Degree of protection IP20 in accordance with EN 60529 (VDE 0470 Part 1) Power dissipation 1 3 W The device features safe separation between the output contact and the input in accordance with EN 50178. The air and creepage distances are designed for overvoltage class III up to 300 V. Relay Data Contact material AgNi, hard gold plated Switching voltage 5 V, 250 VAC / 220 VDC Switching current 10 ma 4 A Fuse 4 A (time-lag), delivery condition: 4 A (time-lag) Switching capacity AC 500 VA, cos > 0.5 830 VA, cos > 0.9 1000 VA, cos > 1.0 Switching capacity DC Up to 30 V: 120 W Up to 70 V: 50 W Up to 127 V: 25 W Up to 220 V: 10 W Remark: With inductive loads, suitable measures such as the use of free-wheeling diodes must be implemented to prevent induction voltages when de-energizing the relay. Bounce time Lifetime mechanical electrical approx. 1 ms 30 x 10 6 switching operations 2.5 x 10 5 switching operations (at ohmic full load and 0.1 switching operations per second) Page 2 of 6 English translation of the German original document:

H 4135A HI 803 003 E (1647) Mechanical Design and Dimensions Depth: 70.5 mm Width: 20 mm Height: 80 mm Figure 2: Mechanical Design and Dimensions Terminal cross-section 0.25 2.5 mm² (AWG 14) Tightening torque 0.5 0.6 Nm Stripping length 8 mm Type of mounting On 35 mm DIN rail or on C rail Mounting position Horizontal or vertical Mounting distance Not required 1 Operating Instructions Observe the following points when installing and operating the H 4135A device: 1.1 Use of H 4135A in Zone 2 The H 4135A device is suitable for mounting in the explosive atmospheres of zone 2. To this end, the special conditions must be observed. The device meets the requirements of the following directives and standards: Compliance Standard Description IECEx IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - ATEX 2014/34/EU EN 60079-0:2012 + A11:2013 General requirements IECEx IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment ATEX 2014/34/EU EN 60079-15:2010 protection by degree of protection "n" Table 1: Standard for HIMA Components in Zone 2 English translation of the German original document: Page 3 of 6

HI 803 003 E (1647) H 4135A The device must be labeled with the following Ex marking: II 3G Ex nc IIC T4 Gc Marking Description Explosion protection marking complying with the relevant directive. II 3G Ex na nc IIC T4 Equipment group, for all areas with explosive atmosphere, other than underground mines. Equipment category, for use in areas in which explosive gas atmosphere is unlikely to occur or, if it does occur, will persist for a short period only. Explosion protection complying with the relevant standard. Type of protection for non-sparking equipment. Type of protection for sparking, sealed equipment. Gas group for explosive gas atmospheres, typical gas is hydrogen. Temperature class T4, with a maximum surface temperature of 135 C. Gc Equipment protection level, it corresponds to ATEX equipment category 3G. Table 2: Ex Marking DescriptionH 4135A Special conditions for H 4135A 1. To ensure compliance with category 3G, the specified devices must be installed in an enclosure that fulfils the requirements of the EN/IEC 60079-15 with degree of protection IP54 or better. 2. The device must be provided with a warning: Warning: Work is only permitted in the de-energized state Exception: If a potentially explosive atmosphere has been precluded, work can also be performed when the device is under voltage. 3. The device is designed for operation not exceeding pollution degree 2. 4. The enclosure in use must be able to safely handle the generated power dissipation. 5. The maximum switching current permitted at ambient temperatures of 50 C or higher and with no mounting distance is 3 A. With a 5 mm mounting distance, the maximum switching current value is 4 A. Applicable standards: IEC 60079-14:2013 / EN 60079-14:2014 Explosive atmospheres - Part 14: Electrical installations design, selection and erection The requirements for type of protection "n" must be observed. Page 4 of 6 English translation of the German original document:

H 4135A HI 803 003 E (1647) 1.2 Proof Test The users must ensure that SIL 3 applications in accordance with IEC 61508 are subject to a proof test in intervals of no longer than 5 years (proof test interval). SIL 2 applications must be subject to a proof test every 20 years. The required proof test can be performed on site without removing the device. 1.2.1 Proof Test Execution In particular, this test is intended to determine if each of the three relay contacts connected in series is open in the de-energized state. A multimeter or a continuity tester is needed to perform the test. To perform the proof test 1. Shut off the device. 2. De-energize the contact circuit. 3. Connect the continuity tester to terminals 7 and 8. If properly fused, continuity is reported (e.g., through an acoustic signal). Through this step, the continuity tester is also tested. 4. Connect the continuity tester to terminal 7 and TP1. No continuity must be reported. 5. Connect the continuity tester to TP1 and TP2. No continuity must be reported. 6. Connect the continuity tester to TP2 and terminal 6. No continuity must be reported. If no continuity is reported during steps 4 through 6, the contacts of the three relays are properly open. The proof test is then successfully completed and the H 4135A device can be used for another proof test interval. 1.3 Replacing the Fuses After a fuse has triggered, it must be replaced. The relay operation must then be checked, see Chapter 1.2.1 for further details. 1.4 Repair Components may only be repaired or replaced by the manufacturer in accordance with the valid standards and the TÜV requirements. 1.5 Certificate and Declaration of Conformity The certificate and declaration of conformity are available on the HIMA website, at www.hima.de and www.hima.com. English translation of the German original document: Page 5 of 6

HI 803 003 E (1647) H 4135A Page 6 of 6 English translation of the German original document: