NJ-Series Power Supply Unit NJ-PA/PD

Similar documents
CQM1-SF200/CS1W-SF200

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Tina 2A/B Adaptor unit

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Original instructions Tina 3A/Aps Adaptor unit

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals

Machine Automation Controller NJ-series. Startup Guide. for Motion Control W514-E1-01

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Safety Manual BT50(T) Safety relay / Expansion relay

Smile 11 AS-i Emergency stop with safe AS-i input node

NX safety stand-alone

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Phase-sequence Phase-loss Relay

RM4TG20 three-phase network control relay RM4-T - range V

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

CompactLogix Power Supplies Specifications

SPST-NO SPDT DPST-NO DPDT

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Liquid Leakage Sensor Amplifier

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Safety technique. Emergency stop module BO 5988 safemaster

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Smart DeviceNet Remote I/O Terminals

Advantium 2 Plus Alarm

Type Terminal Coil Contact form Model

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Ordering Information. Specifications. Electrode Holder Electrode Holders. Accessories (Order Separately)

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

SKR - industry relay

Memory Card (See note.)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

RY2 miniature industrial relays

WE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE a/b/g

Bimetallic Overload Relay Specifications

Operating Manual UWAPS-TINY Series

WINGLIKE ELECTRONICS CO.,LTD

E-STOP relays, safety gate monitors

General-purpose Relays

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

E2K-L. Liquid Level Sensor. Applications. Ordering Information. E-68 Proximity Sensors

Contact expansion modules

Contact expander modules

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

DLP-PU/E Instruction Manual

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Power Supplies 3. SDN-P DIN Rail Series

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

E-STOP relays, safety gate monitors

User s Manual Before using the inverter, you need to read and save the safety instructions.

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Single Phase Soft Starter

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Tactile Switch B3F Through-hole-mounting Switches in a Wide Range of Models: 6 6 mm, 12

Cat. No. W317-E1-11 SYSMAC CPM1A. Programmable Controllers OPERATION MANUAL

Voltage Regulator SPAU 341 C. Product Guide

, User s Manual

48 SERIES Relay interface modules 10 A

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

E-STOP relays, safety gate monitors

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

1756 ControlLogix Chassis Specifications

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

Telephone- and leased line modem for industrial applications TD-36

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Safety Relays ESM/ESM-F

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

ADM1TE 5/30A DIN rail single phase two wire energy meter

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

Transcription:

NJ-Series Power Supply Unit NJ-PA/PD CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O Unit via the dedicated bus. Lineups are provided for AC and DC input types with 30 W output. NJ-PD3001 Features AC input type (100 to 240 VAC)/DC input type (24 VDC) with 30 W output allows power supply to large-scale configurations. Operating output contact indicates the CPU operation status (available in all models). Ordering Information International Standards The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: culus, UC1: culus (Class I Division 2 Products for Hazardous Locations), CU: cul, N: NK, L: Lloyd, and CE: EC Directives. Contact your OMRON representative for further details and applicable conditions for these standards. Power Supply Units Product Name Power supply voltage 5-VDC output capacity Output current 24-VDC output capacity Output capacity Total power consumption 24-VDC service power supply Options RUN output Maintenance forecast monitor Model Standards AC Power Supply Unit DC Power Supply Unit 100 to 240 VAC 6.0 A 1.0 A 30 W No Yes No NJ-PA3001 24 VDC NJ-PD3001 UC1, N, L, CE Note: Power supply units for the CJ-Series cannot be used as a power supply for a CPU rack of the NJ system or as a power supply for an expansion rack. Accessories There is no accessory for the NJ-series Power Supply Unit. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 1

General Specification NJ-PA/PD Item Specifications Model NJ-PA3001 NJ-PD3001 Supply voltage 100 to 240 VAC (wide-range), 50/60 Hz 24 VDC Operating voltage and 85 to 264 VAC, 47 to 63 Hz 19.2 to 28.8 VDC frequency ranges Power consumption 120 VA max. 60 W max. Inrush current 1 Output capacity 2 Output terminal (service supply) RUN output 3 Replacement notification function Insulation resistance 4 Dielectric strength 4 5 At 100 VAC: 20 A/8 ms max. for cold start at room temperature At 200 VAC: 40 A/8 ms max. for cold start at room temperature 5 VDC, 6.0 A (including supply to CPU Unit using CPU Rack) 5 VDC, 6.0 A (using Expansion Rack) 24 VDC, 1.0 A Total: 30 W max. Not provided Contact configuration: SPST-NO Switch capacity: 250 VAC, 2 A (resistive load) 120 VAC, 0.5 A (inductive load), 24 VDC, 2A (resistive load) Not provided 20 MΩ min. (at 500 VDC) between AC external and GR terminals 2,300 VAC 50/60 Hz for 1 min between AC external and GR terminals Leakage current: 10 ma max. At 24 VDC: 30 A/20 ms max. for cold start 20 MΩ min. (at 500 VDC) between DC external and GR terminals 1,000 VAC 50/60 Hz for 1 min between DC external and GR terminals Leakage current: 10 ma max. Noise immunity 2 kv on power supply line (Conforms to IEC 61000-4-4.) Vibration resistance 5 to 8.4 Hz, 3.5-mm amplitude, 8.4 to 150 Hz, acceleration: 9.8 m/s 2 in X, Y, and Z directions for 100 min (Time coefficient: 10 min coefficient factor 10 = total time 100 min) (according to IEC 60068-2-6) Shock resistance 147 m/s 2 3 times each in X, Y, and Z directions (Relay Output Unit: 100 m/s 2 ) (according to IEC 60068-2-27) Ambient operating 0 to 55 C temperature Ambient operating humidity 10% to 90% (with no condensation) Atmosphere Must be free from corrosive gases. Ambient storage -20 to 75 C temperature Grounding Less than 100 Ω Enclosure Mounted in panel Weight 470 g max. 490 g max. 174.7 to 484.7 90 90 mm (W D H) (not including cables) CPU Rack dimensions W = 70 (Power Supply Unit) + 90 (CPU Unit) + 20 n + 31 m + 14.7 (end cover) n is the number of 32-point I/O Units or I/O Control Units and m is the number of other Units. Safety measures Conforms to culus, EC Directives, NK and LR. 1. The AC and DC values above are given for a cold start, and the AC values are at room temperature. The AC inrush control circuit uses a thermistor element with a low-temperature current control characteristic. If the ambient temperature is high or the Controller is hot-started, the thermistor will not be sufficiently cool, and the inrush current given in the table may be exceeded by up to twice the given value. The DC inrush control circuit uses a capacitor-charging delay circuit. If the power is OFF for only a short time for a hot-start, the capacitor will not sufficiently discharge and the inrush current given in the table may be exceeded by up to twice the given value. An inrush current of approximately 4 A may occur and continue for 1 s when the power is turned ON. When selecting fuses, breakers, and external DC power supply devices for external circuits, allow sufficient margin in shut-off performance. 2. Internal components in the Power Supply Unit will deteriorate or be damaged if the Power Supply Unit is used for an extended period of time exceeding the power supply output capacity or if the outputs are shorted. 3. Supported only when mounted to CPU Rack. 4. The tests can also be performed with the LG terminal and GR terminal connected to each other. 5. Change the applied voltage gradually using the adjuster on the Tester. If the full dielectric strength voltage is applied or turned OFF using the switch on the Tester, the generated impulse voltage may damage the Power Supply Unit. 2

External Interface NJ-PA/PD NJ-PA3001 POWER Indicator (PWR LED) AC input Connector LG GR RUN output NJ-PD3001 POWER Indicator (PWR LED) + (DC input) (DC input) Connector LG GR RUN output AC Input Supply 100 to 240 VAC (allowable: 85 to 264 VAC). The NJ-PA3001 has a wide input range, so it does not have voltage switching terminals. DC Input Supply 24 VDC (allowable: 19.2 to 28.8 VDC.) LG Ground to a resistance of 100 Ω or less to increase noise resistance and avoid electric shock. GR Ground to a resistance of 100 Ω or less to avoid electric shock. RUN Output The internal contacts for the RUN output turn ON when the CPU Unit is in RUN status. 3

NJ-PA/PD Wiring About Power Supply For AC/DC power supply Recommended wire diameter AWG 14 to 20 (Cross section 0.517 to 2.08 mm 2 ) For grounding wire Recommended wire diameter 2 mm 2 or thicker Crimp Terminals The terminals on the Power Supply Unit are M4, self-raising terminals with screws. Crimp Terminals for AC Power Supplies 7 mm max. Crimp Terminals for DC Power Supplies 7 mm max. 7 mm max. Crimp terminal for the grounding wire 7 mm max. 7 mm max. Precautions for Use Compatible CPU Models NJ-PA3001/NJ-PD3001 are dedicated for NJ-series. Please make sure to use NJ-PA3001/NJ-PD3001 for all products including NJ-series CPU rack and expansion rack. Power Supply Units Current Consumption Checking Current Consumption and Power Consumption After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack. Condition 1: Current Requirements There are two voltage groups for internal power consumption: 5 V and 24 V. Current consumption at 5 V (internal logic power supply) Current consumption at 24 V (relay driving power supply) Condition 2: Power Requirements For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current supplied for the voltage groups shown in the following tables. The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are shown below. Note: 1. For CPU Racks, include the CPU Unit current and power consumption in the calculations. When expanding, also include the current and power consumption of the I/O Control Unit in the calculations. 2. For Expansion Racks, include the I/O Interface Unit current and power consumption in the calculations. Power Supply Units (A) 5-VDC CPU Racks Max. current supplied (A)5-VDC Expansion Rack (B) 24 VDC (C) Max. total power supplied NJ-PA3001 6.0 A 6.0 A 1.0 A 30 W NJ-PD3001 6.0 A 6.0 A 1.0 A 30 W Including supply to the CPU Unit. Conditions 1 and 2 below must be satisfied. Condition 1: Maximum Current (1) Total Unit current consumption at 5 V (A) value (2) Total Unit current consumption at 24 V (B) value Condition 2: Maximum Power (1) 5 V + (2) 24 V (C) value 4

NJ-PA/PD Example: Calculating Total Current and Power Consumption Example: When the Following Units are Mounted to a NJ-Series CPU Rack Using a NJ-PA3001 Power Supply Unit Unit type Model Quantity Voltage group 5 V 24 V CPU Unit NJ501-1500 1 1.90 A - I/O Control Unit CJ1W-IC101 1 0.02 A - Basic I/O Units (Input Units) CJ1W-ID211 2 0.08 A - CJ1W-ID231 2 0.09 A - Basic I/O Units (Output Units) CJ1W-OC201 2 0.09 A 0.048 A Special I/O Unit CJ1W-DA041 1 0.12 A - CPU Bus Unit CJ1W-SCU22 1 0.28 A - Current consumption 1.9 A+0.02 A+0.08 A Total 2+0.09 A 2+0.09 A 0.048 A 2 2+0.12 A+0.28 Result 2.84 A ( 6.0 A) 0.096 A ( 1.0 A) Power consumption Total 2.84 5 V = 14.2 W 0.096 A 24 V = 2.3 W Result 14.2 W + 2.3 W = 16.5 W ( 30 W) Using the Sysmac Studio to Display Current Consumption and Width CPU Rack and Expansion Rack current consumption and width can be displayed by selecting CPU/Expansion Racks from the Configurations and Setup in the Multiview Explorer. If the capacity of the Power Supply Unit is exceeded, an error icon is displayed in the power supply unit of a corresponding rack. For details, refer to Sysmac Studio Operation manual (W504). 5

Dimensions NJ-PA/PD (Unit: mm) NJ-PA3001 90 90 70 NJ-PD3001 90 90 70 Related Manuals Manual name Cat. No. Model numbers Application Description NJ-series CPU Unit Hardware User s Manual W500 NJ501-@@@@ Learning the basic specifications of the NJ-series CPU Units, including introductory information, designing, installation, and maintenance. Mainly hardware information is provided. An introduction to the entire NJ-series system is provided along with the following information on a Controller built with an NJ501 CPU Unit. Features and system configuration Introduction Part names and functions General specifications Installation and wiring Maintenance and inspection Use this manual together with the NJ-series CPU Unit Software User s Manual (Cat. No. W501). 6

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2011.12 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2011 All Right Reserved.