SPECIFICATION SHEET 24VDC 12VDC. Dimmer + Driver SPEC SHEET 1 OF 5 OVERVIEW FEATURES & BENEFITS COLOURS AND FINISHES APPROVED 24V LED FIXTURES

Similar documents
STRATO LED Drivers 70W, Single output

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

STR7 Low Profile LED Strip Luminaire

Welcome to this presentation on Driving LEDs AC-DC Power Supplies, part of OSRAM Opto Semiconductors LED Fundamentals series. In this presentation we

12V Dimmable Driver EL-TMDRVR

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Product and functional description

Advantium 2 Plus Alarm

HMI display Installation Guide

Inspired LED Price List

Duct Humidity Transmitter

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Connecting the Channel A

15 Series - Electronic step relay and dimmer. Features SERIE

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

INSTALLATION INSTRUCTIONS

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

How To Read A Pipe From A Sensor

Cove lighting and tight space RGB LED luminaire

MCR1900 Media Converter 19-Slot Chassis

High Bay Occupancy Sensor Selection Guide

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

IntesisBox KNX - LON

OPTOTRONIC LED Power Supply OT180W/UNV/800C/2DIMLT2/P6 - Technical Specifications

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Intersection Preassembled 19-inch Rack

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Drayton Digistat +2RF/+3RF

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

Application Note: Emergency Battery Backup System (EBBS) Solutions for the XIM Platform

SECTION LOW VOLTAGE LIGHTING CONTROLS

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

16/32 Channel 1U Rack Mount CCTV Power Supply

LED DIMMING A HELPFUL GUIDE...

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

Color Mark Sensor with Red or Green LED E3S-VS

LIEBERT VNSA Installation Sheet

HM-W536 Install Guide

INSTALLATION INSTRUCTION Touch Panel Switch with Occupancy Sensor

DuroSite TM High Bay Lighting

On/Off Relay Switch and 3-Way Switch Kit

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

FLEX by 3M Light Module System

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

D4 HP Dimmer User s Manual Rev City Theatrical, Inc.

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

LED-INTA-0024V-41-F-O

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Operating Instructions. Room temperature controller

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

IntesisBox KNX Mitsubishi Heavy Industries AC

Power Supplies 3. SDN-P DIN Rail Series

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Tina 2A/B Adaptor unit

UNRIVALED EMERGENCY SOLUTIONS FOR LEDs CLASS 2 OUTPUT COMPLIANCE WITH AUTO-SENSE FORWARD VOLTAGE

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Datasheet. Arrant-Light Oy. 120W DR Series

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Antenna Splitter ASA 1. Instruction manual

1247 Norwood Avenue, Itasca, IL (800)

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Original instructions Tina 3A/Aps Adaptor unit

Video Conference Indirect Wash LED Fixture

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Agilent 87421A/87422A Power Supply

LED control gear. LED control gear

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

Redundancy Module QUINT-DIODE/40

How To Test A Power Distribution Unit

Model 201 Wiegand Touchpad Reader Installation Guide

38 Series - Relay interface modules A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

User s Manual Before using the inverter, you need to read and save the safety instructions.

I STAR COMPUTER CO., LTD

INDEX CLS FLORENCE GIII SAFETY INFORMATION CONTENT. Manual Version 2.0 May Index 2

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

PUCK LED 3W, 12V AC/DC REV

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

RGB Light Panel Applications. RGB LED Light Panel FEATURES & BENEFITS SPECIFICATION SHEET

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

New Architectural Accessories

Transcription:

12VDC 24VDC DRY LOCATION DIMMABLE Dimmer Driver SPECIFICATION SHEET OVERVIEW SWITCHEX simplifies LED array lighting systems by combining an inwall LED dimmer switch and power supply into a single integrated unit. SWITCHEX mounts in a standard in-wall switch box, accepts 120V AC and converts to low voltage DC. SWITCHEX is compatible with 2-channel 12V and 24VDC tape lights and fixtures. FEATURES & BENEFITS COLOURS AND FINISHES First LED Driver In-Wall Dimmer Switch in one unit. Simplifies LED installation by eliminating compatibility issues between driver and dimmer. Fits in a standard recessed electrical box. 100% - 1% smooth dimming. No minimum load. Single Pole preset dimmer with on/off push switch. Adjustable voltage output dial to address voltage drop. Includes voltage barrier partition to install high and low voltage circuit in same switch box. No derating required when ganging units. Power failure memory: If power is interrupted, SWITCHEX will return to setting prior to interruption. 3x included face plates: White, Light Almond, and Dark Brown (trim plates not included). APPROVED 24V LED FIXTURES White Light Almond Dark Brown Black LED Strip Series LED estrip LED Globe Light LED Hard Strip LED Thin Star LED Mini Star II LED Britestrip APPROVED 12V LED FIXTURES LED Mini Disc Light LED Disc Light Item # Project SPEC SHEET 1 OF 5

SPECIFICATIONS Compliance & Regulatory Approvals culus Listed (US & Canada) Low Voltage Lighting System #E472619. FCC Approved. Complies with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. RoHS Certified. CE Certified. Conforms to NEC Code 725.136 (See Mechanical Diagram): Class 1 and Class 2 circuit in same enclosure must be separated by a barrier (partition) unless Class 2 circuit conductors are install in accordance with 725.41 Class 1 Circuits. Input Input Voltage: 120VAC (108 ~ 132VAC), 50/60Hz (47 ~ 63Hz) Power Factor: >0.9 @ 120VAC 60Hz max load. Total Harmonic Distortion (THD): 20% @ 120VAC 60Hz max load. Tested to comply in accordance with IEC 61000-3-2. Stand-by Power: 0.5W. Efficiency: 91% @ 120VAC max load. Input Current: <1.0A @ 120VAC max load. In-Rush Current: Meets NEMA-410 requirement at any nominal input full sine wave voltage and maximum load at 25 C. Leakage Current: <500μA @ 120VAC. Surge/Transient: Tested to meet transients defined in IEC 6100-4-4, level 3 & IEC 6100-4-5, level 3. Output Dimming: Output voltage is adjustable via sliding lever Voltage Adjustment Dial: Increases output 1V to compensate for voltage drop from control to luminaire. Startup Time: The main supply output voltages remain within the regulation limit of /- 3%. Protections: Short circuit, thermal runway, and over voltage. Output Ripple Current: 20% of the rated output current @ 120VAC max load. Environmental Requirements Indoor use only. Ambient Operating Temperature: 0 C to 40 C Humidity: 8 ~ 90% relative humidity, non-condensing. DIMMER MODELS Input Output Max Load SX-12V-DD-60W 12 VDC, 5A 120VAC SX-24V-DD-100W 24 VDC 100 W, 4.2A Each Item # includes following accessories: SWITCHEX Barrier Face Plate (3)* Twisted Connector (4) * Face Plates are interchangeable: Mounting Screw (2) Squeeze Lift Off Snap in new colour TRIM PLATES (SOLD SEPARATELY) ITEM # DI-SE-TP-WH DI-SE-TP-LA DI-SE-TP-BR COLOUR/FINISH White Light Almond Dark Brown SYSTEM DIAGRAM TRIM PLATES (SOLD SEPARATELY) L (BLK) N (WHT) 120 VAC ~ 60Hz SWITCHEX (Dimmer Driver) V (BLUE) V (RED) 12 or 24 VDC LED ARRAY / FIXTURE ITEM # DI-SE-FP-BL COLOUR/FINISH Black Includes Black Switchex Face Plate & Trim Plate. Ground (GRN) SPEC SHEET 2 OF 5

OPERATION MOUNTING Slide to adjust brightness 100% - 1%. Push to turn ON/OFF. WALL BOX (Sold separately) SWITCHEX MECHANICAL DIAGRAM TRIM PLATE (Sold separately) SWITCHEX Front Back Side with Voltage Barrier 3.82 in. (97mm) 3.3 in. (83mm) 2.6 in. (66mm) 4.1 in. (105mm) 1.6 in. (41mm) 0.1 in. (3mm) 0.2 in. (6mm) 1.3 in. (33mm) 1.7 in. (44mm) 2.1 in. (54mm) 1.4 in. (35mm) 1.8 in. (47mm) Trim Plate Front Side Barrier Top Side 1.6 in. (40mm) 0.4 in. (9mm) 3.82 in. (97mm) 4.51 in. (114mm) 0.3 in. (2mm) 1.8 in. (47mm) For shallow boxes, barrier can be shortened. Grip with pliers. Bend back and forth until fin breaks off. 2.8 in. (70mm) 0.25 in. (6mm) SPEC SHEET 3 OF 5

VOLTAGE DROP CHARTS For best performance and lumen output, ensure proper wire gauge is installed to compensate for voltage drop of low voltage circuits. Example: 12V Voltage Drop & Length Distance Chart 18 AWG 34 ft. 17 ft. 11 ft. 8 ft. 6 ft. 5 ft. 16 AWG 54 ft. 27 ft. 18 ft. 13 ft. 10 ft. 9 ft. 14 AWG 86 ft. 43 ft. 29 ft. 21 ft. 17 ft. 14 ft. 4.2 A 12 AWG 134 ft. 68 ft. 45 ft. 34 ft. 27 ft. 22 ft. 10 AWG 199 ft. 99 ft. 66 ft. 49 ft. 39 ft. 33 ft. Determine load size. Let s assume load is 55 W. Round up to nearest load. Determine distance from SWITCHEX to load. Let s assume the distance is 20 ft. It s recommended to install 12 AWG to eliminate excess voltage drop. 12V Voltage Drop & Length Distance Chart 24V Voltage Drop & Length Distance Chart.42 A VOLTAGE ADJUSTMENT 1.3 A 18 AWG 34 ft. 17 ft. 11 ft. 8 ft. 6 ft. 5 ft. 16 AWG 54 ft. 27 ft. 18 ft. 13 ft. 10 ft. 9 ft. 4.2 A 14 AWG 86 ft. 43 ft. 29 ft. 21 ft. 17 ft. 14 ft. 12 AWG 134 ft. 68 ft. 45 ft. 34 ft. 27 ft. 22 ft. 10 AWG 199 ft. 99 ft. 66 ft. 49 ft. 39 ft. 33 ft. 70 W 2.9 A 80 W 18 AWG 134 ft. 68 ft. 45 ft. 33 ft. 27 ft. 22 ft. 19 ft. 17 ft. 14 ft. 16 AWG 215 ft. 109 ft. 72 ft. 54 ft. 43 ft. 36 ft. 31 ft. 27 ft. 22 ft. 14 AWG 345 ft. 174 ft. 115 ft. 86 ft. 69 ft. 57 ft. 49 ft. 43 ft. 36 ft. 12 AWG 539 ft. 272 ft. 181 ft. 135 ft. 108 ft. 90 ft. 77 ft. 68 ft. 56 ft. 10 AWG 784 ft. 397 ft. 263 ft. 197 ft. 158 ft. 131 ft. 112 ft. 98 ft. 82 ft. 100 W 4. 2 A SWITCHEX can provide a 1V boost if the fixture is receiving noticeable light degradation. a. Pop off face plate as shown in Step 4 of INSTALLATION. b. Use a small screwdriver to adjust output voltage by turning adjustment dial clockwise. V ADJ SPEC SHEET 4 OF 5

SAFETY & WARNINGS 1. UNLIKE TRADITIONAL DIMMING CONTROLS, SWITCHEX REQUIRES UNIQUE WIRING STEPS. READ ALL WARNINGS AND INSTALLATION INSTRUCTIONS THOROUGHLY. 2. Install in accordance with national and local electrical code regulations. 3. This product is intended to be installed and serviced by a qualified, licensed electrician. 4. CEC Code: Rule 16-212 requires the separation of Class 2 conductors from various other circuits like electric power, Class 1, and electric lighting through appropriate minimum separations or barriers of raceway, cable or other metal or non-metal material. 5. Only install compatible 12V or 24V Constant Voltage DC fixtures or warranty will be void. 6. Do not modify product beyond instructions or warranty will be void. WARRANTY Limited Warranty This product has a five (5) year limited warranty from the date of shipment. This warranty does not include the additional accessories referenced in this specification sheet. Complete warranty details for fixtures and additional accessories are available at www. magiclite.com under the Tools & Resources tab. For warranty related questions, please contact product support. Consumer s Acknowledgment Magic Lite stands behind its products when they are used properly and according to our specifications. By purchasing our products, the purchaser agrees and acknowledges that lighting design, configuration and installation is a complex process, wherein seemingly minor factors or changes in layout and infield adjustments can have a significant impact on an entire system. Choosing the correct components is essential. Magic Lite is able to work with the original purchaser to make an appropriate product selection to the extent of the limited information that the customer can provide, but it is virtually impossible for Magic Lite to design a system that foresees every unknown factor. For this reason, this Warranty does not cover problems caused by improper design, configuration or installation issues. Any statement from a Magic Lite employee or agent regarding a customer s bill of goods and/ or purchase order is NOT an acknowledgment that the products purchased are designed and configured correctly. The purchase agrees and acknowledges that it is the customer s responsibility to adhere strictly to all information contained in the Product Specification Sheets. There is often more than one way to design, configure and layout an LED lighting application properly to achieve the same lighting effect. Magic Lite strongly recommends that licensed professionals be used in the design and installation of lighting systems that include Magic Lite products. The specifications include important information that a designer and installer should carefully review and strictly follow. Qualified designers and certified and/or licensed installers, with access to the final installation environment, customer goals, and Magic Lite product specifications can make the requisite decisions appropriate for a successful finished lighting application. 1150 Northside Road, Unit 14 Burlington, Ontario L7M 1W8 Canada T: 905 825-9592 F: 905-825-8334 SPEC SHEET 5 OF 5