KPA Fan-out Bracket (Two brackets may be installed. Each bracket holds up to 12 BTF kits.)

Similar documents
Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

5800 Temperature Sensor Cable Assembly

COYOTE PUP CLOSURE FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 17" (152.4 mm x mm)

Installation Instructions

Andersen Electric Window Opener for Andersen Awning and Roof Windows

DCF Optimized Rack System

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

Rack installation instructions

Rack Installation Instructions

INSTRUCTIONS: LocknCharge Laptop Carts

9,000lb capacity 4 Post Lift Installation Manual

42U/45U 28" Wide Rack Installation & Service Guide

LIEBERT VNSA Installation Sheet

Pretium Connector Housings

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Ceiling Mounted Folding Attic Ladders Installation Instructions

PRS X-axis E-chain installation: For tools with a 12 Z-Axis

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

430 Power/Electronics Replacement

GPS AutoSteer System Installation Manual

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

Part Name/Description Part Number Quantity. Power Cable

ONTRAC WIRE MESH CABLE TRAY SYSTEM

Procedure for Cutting and Respooling Fiber Optic Cable

39HQ Airovision Air Handling Units

Operating Instructions

HP 16/18-Port Cable Management Kit Installation Guide

TONNEAU INSTALLATION GUIDE

GENUINE PARTS INSTALLATION INSTRUCTIONS

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

Panel Track Installation Guide

CamSplice Assembly Manual

KEYPAD LOCK RETROFIT KIT

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Speed-Mat Rectangle Cutter

OWNER S MANUAL Table Tennis Table Patent Pending

with installation dynafact boost GAUGE this manual is for use with systems

Determine the desired location fixture and center the coaxial cord location to the electrical box.

INSTALLATION INSTRUCTIONS

ilan Ethernet Box for 9100 Installation Manual

TECHNICAL GUIDE. For Self-Shielded Guns - 300, 400 and 500 amp SAFETY AND WARRANTY INFORMATION INSTALLATION MAINTENANCE GUIDE TECHNICAL DATA OPTIONS

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

AM/FM ANTENNA RELOCATION KIT

TOYOTA TUNDRA 2015 Billet Grille w/led DRL

Owner s Manual & Safety Instructions

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Installation Instructions

RZ Guardrail System Installation Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

AMF112 Instruction Manual

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

R O A D M A S T E R, I N C.

2178-S Fiber Optic Splice Case

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

758 Heavy-duty Ratchet Guy Wire Cutter

AMF112 ( <00>) 13mm (1/2 in.)

Chelsea Loft Bed WARNING:

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

R O A D M A S T E R, I N C.

Control Box Wiring For PRSstandard Tool

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Roll-Up Door Maintenance Guide

Operating Instructions

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

I BEAM TRACK INSTALLATION

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

March 14, Installation of Bay, Bow and Garden Windows

Extra Tall Wide Span Gate

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

Seismic Installation for Attic Storage System

FL ADJUSTABLE RIDER BACKREST MOUNTING HARDWARE KIT

RayClic Connection System Installation Instructions

ReachFree ID Installation Instructions For Portal TI, Sentinel and C-Start. Unitec

WARNING: Important: Keep these instructions for future reference. Gate Instructions (1) Assembly and Installation Instructions

INSTALLATION MANUAL. Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

BIX Termination Blocks

4RU High Density Shelf Installation Instructions

ASSEMBLY INSTRUCTIONS FOR L&L EASY-FIRE AND SCHOOL-MASTER KILNS

CETAC Z-Drive Assembly

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Guidelines for Earthquake Bracing Residential Water Heaters

Transcription:

related literature STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 1 OF 11 Fiber Zone Box p/n 003-695, Issue 4 1. Tools and Materials Panel-lifter (suction cup for laminate panels or hook-and-loop for carpeted panels) for accessing the raised floor. Screwdriver and other standard tools (pliers, etc.) Mounting hardware is not provided. The type of hardware used depends on the mounting location; wall anchors may be required for adequate support on sheetrock walls. 2. Components 4 Wallmounting Brackets Tiltable 19-inch Frame Quick-release Latches 4 Radius Control Guides Ground Stud Fan-out Bracket (Two brackets may be installed. Each bracket holds up to 12 BTF kits.) Universal Cable Clamp Record Label Door Latch Figure 1 Quick-release latches on each corner of the inner tray allow the tray to be removed from the cabinet for ease of fiber routing, if desired. The unit is 21 inches wide by 21 inches high by 9 inches deep. It weights 11 kg (24 pounds). KPA-2409 PRETERMINATED SYSTEMS CABLES CONNECTORS CABLE ASSEMBLIES HARDWARE TOOL KITS AND ACCESSORIES TEST EQUIPMENT SPLICE EQUIPMENT FAN-OUT KITS TRAINING

3. gaining access to the Fiber Zone Box (FZB) 3.1. To Open the Door Unlock the door; then remove the key. Pull the latch handle up and turn it one-quarter turn. KPA-2408 Figure 2 3.2. To Allow Inner Tray to be Removed Remove the two packing screws indicated to enable the inner tray to be removed when the quick-release latches are activated. Packing Screws KPA-2410 Figure 3 3.3. To Remove the Door Step 4: Step 5: Remove the hole plug and insert a screwdriver through the hole. Loosen the screw on the hinge bracket. Slide the hinge bracket out of the way. Slide the door up to disengage the hinge pin. Lift door off the cabinet. KPA-2411 Figure 4 4. Mounting the cabinet 4.1. To a Wall Install (4) supplied wall-mounting brackets to cabinet using provided screws (Figure 1). Determine the mounting location. Select a flat vertical surface for mounting to prevent warping. IMPORTANT: Make sure there is adequate space for the door to open without interference. Use a pencil to mark the wall through the holes in the mounting brackets. Step 4: Drive the screws in at these locations. Step 5: Hang the cabinet on the screws and tighten screws securely. STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 2 OF 11

4.2. Underneath a Raised Floor 4.2.1 Direct Method Select an installation location and remove five adjacent floor tiles in a + pattern using a panel-lift tool. The unit will be installed in the center of the +. Although the FZB can be installed by removing only two floor tiles or panels (when it is not practical to remove more), removing five panels facilitates installation and inspection for obstacles. TPA-3999 Install provided floor trim plates (p/n 10-031423- 001) on both sides of the housing with provided screws. Figure 5 TPA-4001 Step 4: Lower housing into center opening of floor tiles. Opening the door and using the interior ledge of the housing as a handle may facilitate installation. The trim plates should rest directly on the floor system posts or stanchions. Reinstall all floor tiles with the panel-lifter tool. Ensure tiles are even with adjacent tiles. If the floor tile over the FZB will not lay flat and even, it may be necessary to install the box below the stringers as described in Section 4.2.3. Figure 6 IMPORTANT: Due to variations in raised floor systems, installation sequences may deviate from this direct installation method. If necessary, proceed to Section 4.2.2 or 4.2.3 for alternative installation methods. TPA-4000 Figure 7 STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 3 OF 11

4.2.2 Alternative Method 1 If unable to successfully install the unit under a raised floor following the instructions in Section 4.2.1: TPA-4002 Remove one of the trim plates and reinsert the housing into the center opening. Allow the side where the trim plate was removed to drop below the stringer on that side (Figure 8). Figure 8 Position the trim plate into the gap between the stringer and the FZB. Reinstall the trim plate to the side of the unit with the provided screws (Figure 8 inset). (It may require two people to perform this operation.) Reinstall all floor tiles with the panel-lifter tool. Ensure tiles are even with adjacent tiles. If the floor tile over the FZB will not lay flat and even, it may be necessary to install the box below the stringers as described in Section 4.2.3. 4.2.3 Alternative Method 2 With some raised floor systems and/or if desired, the FZB may be mounted directly to the substructure. If there are no cables or conduit running under the FZB, the bottom of the unit will rest directly on the substructure or concrete floor. Ensure there is enough depth for the top of the unit to be just below the stringers. Remove stringers, lower FZB into the opening below the level of the stringers, and reinstall the stringers. Reinstall all floor tiles with the panel-lifter tool. Ensure tiles are even with adjacent tiles. STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 4 OF 11

4.3. In a Suspended Ceiling In a suspended ceiling, the door of the FZB can replace the tile for optimal accessibility. To do so, a ceiling trim plate kit ((p/n FZB-04U-CLG, ordered separately) must be installed onto the FZB. Mounting hardware and supports are not included. Use framing members (threaded rod in conjunction with metal struts) or support wires compliant with NEC Article 314.23 D (Supports for Suspending Ceilings). Support wires must be capable of supporting a fully loaded FZB (maximum 50 lb.). Install (4) supplied wallmount brackets to the FZB using the provided screws. Install ceiling trim plate kit ((p/n FZB-04U CLG) as shown in Figure 9. Ceiling Trim Plates Wallmount Brackets TPA-4003 Figure 9 Determine mounting location of FZB in the ceiling and remove two ceiling panels or tiles (Figure 10). TPA-4004 Figure 10 Step 4: Step 5: Measure distance to building red-iron or other structural or supporting elements. Use this measurement, plus any slack length required for tieing the wire or installing nuts on threaded rod, to determine the length of each of the four support wires or rods. Attach the tie wires (or threaded rod) to the supporting element. Tie wires are simply tied or wrapped around the supporting truss or girder. In the case of threaded rods, use a supporting bracket and hardware compliant with the manufacturer s instructions. STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 5 OF 11

Step 6: Step 7: Tilt the FZB at an angle to allow it to pass through with the trim plates and mounting brackets installed. Pass the box through the opening in the ceiling (Figure 11). Position the box in place so that the trim plates rest directly on the suspended ceiling stringers or cross members while attaching the primary support wires or rods. Figure 11 Step 8: Step 9: Pass the supporting tie wires or threaded rods through the mounting brackets (Figure 12). If using wire, simply pass the wire through the hole in the mounting bracket, loop back up, and make several wraps around the wire. Adjust the tension by bending the wire with a pair of pliers. It is important not to allow the suspended ceiling stringers to bear the weight of the FZB. TPA-4006 Figure 12 If using threaded rods, it may be necessary to adjust the top or bottom supporting bolts/nuts. Step 10: Ensure the FZB is level and offset slightly from the stringers or crossmembers so that the FZB is only slightly resting on the suspending ceiling. Step 11: Reinstall the ceiling panels / tiles to complete the installation (Figure 13). Ensure that the door is properly closed and locked to prevent unauthorized access and harm from the door swinging down. TPA-4007 Figure 13 STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 6 OF 11

5. Strain-relieving the cable Perform cable sheath removal steps per instructions for the type of termination being performed. Expose 10 feet of buffer tube for fan-out applications. Remove cable jacket appropriately for direct connectorization of multi-fiber indoor cable. Do not expose the bare fiber until you are ready to terminate it. IMPORTANT: To maintain a NEMA 12K rating, cable must enter the cabinet through a watertight cord connector fitting. Two fittings are included. 5.1. Using the Cord Connector Fitting Step 4: Step 5: Step 6: Remove the 1-inch knockout to install the cord connector. Install cord connectors with the knurled nut on the outside of the housing. To clamp the housing tightly, orient the washers so that there is a gap between them in the center as they are clamped together (Figure 14). Secure the cord connector on the inside of the housing using the provided lock nut. Thread the cable through the fitting. Tighten the nuts. 5.2. Using the Universal Cable Clamp (UCC) Housing Lock Nut Reducing Washer Cord Connector Knurled Nut KPA-2176 Figure 14 Attach the UCC clamshell to the strain-relief bracket using the screws provided in the UCC kit (). Install cable into the UCC following the instructions provided with the UCC kit. KPA-2413 Figure 15 To secure cable entering from the rear of the cabinet, attach the strain-relief bracket to the inner tray directly above the cable entry knockout. IMPORTANT: When using Plug & Play system, the cable must enter the housing from the sides. The NEMA 12K rating cannot be maintained using Plug & Play cable because the watertight fitting cannot be used. Bracket KPA-2412 Figure 16 STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 7 OF 11

6. Grounding Armored Cable A ground kit (purchased separately is required for armored cable. Attach the ground wire to the cable armor according to the instructions provided with the ground kit. Attach the other end of the ground wire to the ground stud inside the cabinet (Figure 17). Then, run a #6 AWG ground wire (purchased separately at any electrical supply store) from the ground stud to the primary building ground according to the local code authority. IMPORTANT: To maintain the NEMA 12K rating, the ground wire must utilize a watertight connector (purchased separately). 7. Installing Cable If using the optional splicing kit, cables must enter from the top or bottom of the unit. Remove the blank panels and install connector panels or modules into the unit. Connector panels with connector adapters are purchased separately. Ground Wire Figure 17 If fibers are not already connectorized, install connectors onto the fibers according to the instructions provided with the connectors. You may use the optional splicing kit (p/n FZB- SPLC-85) to splice stubbed modules or pigtails to the cables. Refer to the instructions provided with the kit for fiber routing configurations. Refer to the instructions provided with the splice trays for fiber strip lengths and routing inside the trays. Clean the connectors as described in this section and install them into the connector panels. You may lift up on the 19-inch frame and secure it in a slanted position to make it easier to install connectors into the panel. Obey the following precautions in order not to damage the surface of the connector and make it unusable: Use a clean tissue soaked in alcohol to gently clean the connector. Do not press heavily on it as you clean. Dry the connector prior to installation by using a dry tissue or blowing it dry with compressed air. Clean all areas that will contact the connector adapter. Do not force the connector into the receptacle. If the connector does not fit easily into the receptacle, back it out and reinstall. Install threaded connectors into the adapter and tighten. Do not OVERTIGHTEN. Do not allow the connector body (ferrule) to turn as you screw it into place. This causes the surfaces to grind against each other. Step 4: Route the fiber around the fiber guides on the inner tray. Make sure there is adequate slack so that the fiber bend radius is maintained across the routing guides. Refer to Figure 18 for examples of routing configurations. KPA-2414 STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 8 OF 11

Side Entry Top Entry KPA-2415 KPA-2416 Figure 18 Step 5: When installing cable for the Plug & Play system, route to modules as shown in Figure 19. Side Entry Top Entry KPA-2417 KPA-2418 8. Installing Buffer Tube Fan-out Bodies Figure 19 Loose-tube fiber optic cable can be installed using buffer tube fan-out (BTF) kits (purchased separately). The FZB unit allows termination of distribution cable using kits. Up to twelve BTF kits can be installed on each fan-out bracket. Install the fan-out bracket using the provided screws. Route the buffer tubes around the guides. STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 9 OF 11

Step 4: Step 5: Position the buffer tubes against the fan-out bracket. Mark the location of the fan-out on the buffer tubes to determine the length required. Install fan-out assemblies and connectors according to the instructions provided with the BTF kits. Slide the fan-out bodies into the bracket and secure using a cable tie (Figure 20). Buffer Tubes Cable Tie Buffer Tube Fanout Bodies KPA-2419 Figure 20 Step 6: Step 7: Route the connectorized fan-out tubing around the guides and plug connectors into the connector panel (Figure 21). Refer to the connector care instructions in section 9.3 to clean the connectors and avoid damage to them during installation. Record information appropriately on the record label on the inside of the door. IMPORTANT: Accurate record keeping is imperative for an organized installation. Side Entry Top Entry KPA-2420 KPA-2421 Figure 21 STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 10 OF 11

9. Maintaining the Equipment The unit requires very little maintenance to make sure fibers and parts remain in good condition. Loose Parts: Check nuts, bolts and screws for looseness and tighten. Moisture: Check the housing for accumulated moisture and place moisture absorbent packets as needed. Fiber Bends: Check fiber optic cable to make sure bends do not violate the minimum bend radius. Check cable for unnecessary strain. Check cable entries and exits for crimping or crushing. Documentation: Check record label to make sure it is clear and accurate. Corning Cable Systems LLC PO Box 489 Hickory, NC 28603-0489 USA 1-800-743-2671 FAX +1-828-325-5060 International +1-828-901-5000 http://www.corning.com/cablesystems Corning Cable Systems reserves the right to improve, enhance, and modify the features and specifications of Corning Cable Systems products without prior notification. Plug & Play is a trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. 2012 Corning Cable Systems. All rights reserved. Published in Mexico. STANDARD RECOMMENDED PROCEDURE 003-695 ISSUE 4 January 2012 PAGE 11 OF 11