EMC TEST REPORT. Oina VV AB. Dispenser system. Accurate speedcontrol BM/ Report no: Approved by Tobias Gustavsson

Similar documents
TEST REPORT EN (1997) +A1 (2001)

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Electromagnetic Compatibility Test Report Test results of Floww equipment

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

Test Report #: Date: April 8, 2005

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Declaration of Conformity.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

Declaration of Conformity.

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC Test for Compliance with EU EMC Directive 2004/108/EU

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Declaration of Conformity.

Declaration of Conformity.

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

Declaration of Conformity.

RAPPORTO DI PROVA / TEST REPORT

Declaration of Conformity.

Telephone- and leased line modem for industrial applications TD-36

Dual Chamber Temporary External Pacemaker

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

STRATO LED Drivers 70W, Single output

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

Rules for Classification and Construction Additional Rules and Guidelines

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

The EMI-Receiver according to CISPR

38 Series - Relay interface modules A

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

Jens-EMC ApS. Randersvej 6 DK-8600 Silkeborg Denmark. EMC test report SeaCom. AC48/SeaCom1000 & AC128/SeaCom2100

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

CERTIFICATE OF CONFORMITY

38 Series - Relay interface modules A

7.5 Watt AC-DC Switch Power Supply

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

TEST REPORT FROM RFI GLOBAL SERVICES LTD

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

40 Years of experience in EMC testing

Waveguide Access Point WGA631. Product Guide

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Energy Management Energy Meter Type EM23 DIN

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

Rack mounted telephone- and leased line modem for industrial applications

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Uncertainty evaluations in EMC measurements

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

EMC for test engineers by. Laplace Instruments Ltd. An introduction to the world of EMC compliance testing for engineers new to the topic.

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

Disk Contents: Limit Lines and Transducer Factors

PRODUCT DATA SHEET AUDIO LINE COMBINATION ALC

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

30 In Compliance October

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Espotel Test Laboratory Services. November 20, 2014

DATA SHEET DVI - HDCP Extension Cable

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Current Probes. User Manual

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

for Communication Systems Protection EMI CD-ROM INCLUDED

Cond-IS RF Conducted Immunity System

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

RAPPORTO DI PROVA TEST REPORT. Titolo (Title): EMC Immunity test and measure of the harmonic components and Flicker on. SP40 plus

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

80 Series - Modular timers 16 A. Features

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

SAR ASSOCIATED WITH THE USE OF HANDS-FREE MOBILE TELEPHONES

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Advancements in Lightning Test Services

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Declaration of Conformity.

Transcription:

EMC TEST REPORT Oina VV AB Dispenser system Accurate speedcontrol BM/ Report no: 09006 Prepared by Ulf Heiding Approved by Tobias Gustavsson Date 2009-01-23 This report may not be reproduced other than in full, except with the prior written approval of Dectron AB. Dectron AB Tel sw. board +46 (0)485 563 900 Org. & VAT no SE556339-0300 Thörnblads väg 6 Göran Tordsson +46 (0)485 563 908 Postgiro 86 83 83-1 SE-386 90 FÄRJESTADEN Ulf Heiding +46 (0)485 563 904 Bankgiro 5440-9347 SWEDEN Tobias Gustavsson +46 (0)485 563 905 Web-site www.dectron.se Dectron test report 09006 Page 1 of 23

Table of contents Report no: 09006 Page Front... 1 Table of contents... 2 Head information... 3 Test summary... 4 Measurements uncertainties... 5 Conducted disturbance test set-up... 6 Radiated disturbance test set-up... 7 Immunity test equipment... 8 Emission test equipment... 9 Immunity test results Electrostatic discharge (ESD) acc. to EN 61000-4-2... 10 Radiated radio frequency electromagnetic field acc. to EN 61000-4-3... 11 Electrical fast transient/burst acc. to EN 61000-4-4... 12 Surge acc. to EN 61000-4-5... 13 Induced radio frequency field acc. to EN 61000-4-6... 14 Voltage dips and short interruptions acc. to EN 61000-4-11... 15 Emission test results Conducted disturbance voltage... 16-19 Radiated disturbance, worst-case... 20-23 Dectron test report 09006 Page 2 of 23

Report no 09006 Head information Date 2009-01-23 Prepared by Ulf Heiding Customer Oina VV AB Postal address Stäksholmen, SE-139 90 Värmdö, Sweden Tel +46 8 773 34 35 Contact person Anders Lovas Fax +46 8 571 60 145 Type of apparatus Dispenser system Type no Accurate speedcontrol BM/ Voltage 230 Vac No of phases 1 Current - A Power 35 W Class I, earthed Class II, double insulated DC application Tested acc to Emission: EN 61000-6-3:2007 Immunity: EN 61000-6-2:2005, EN 61000-4-2, -3, -4, -5, -6, -11 Test result Approved Note The test results in this report apply only to the tested sample of EUT. Not approved Mains adapter used: Nordic power model 0055 AC to DC adapter, 24Vdc, 1.5A. Criteria for normal performance: No noticeable change of motor speed, no change of state, no accidental starts or stops were allowed. Immunity tests made with speed 50%, internal control. Dectron test report 09006 Page 3 of 23

Test summary Report no: 09006 Emission according to EN 61000-6-3:2007 * Environmental phenomena Basic Standard Result Comments Conducted disturbance EN 61000-6-3:2007 Passed * Radiated disturbance EN 61000-6-3:2007 Passed * Harmonics EN 61000-3-2: 2001 Not applicable < 75W Flicker EN 61000-3-3: 1995, A1: 2001 Not applicable < 75W Immunity according to EN 61000-6-2:2005 * Environmental phenomena Basic Standard Test specifications Result Comments Electrostatic discharge (ESD) EN 61000-4-2: 1995 Contact discharge Air discharge 2, 4 kv 2, 4, 8 kv Passed Passed Radio-frequency electromagnetic field EN 61000-4-3: 1997 80-2 700 MHz 10 V/m AM 80%, 1 khz sinus Passed * Tested with + 20 % Fast transients EN 61000-4-4: 1995 Coupling network Capacitive clamp 2 kv 1 kv Passed Passed Surges EN 61000-4-5: 1995 Line to line Line to earth 0.5, 1 kv - kv Passed Not applicable Class II Induced radiofrequency field EN 61000-4-6: 1996 0.15-80 MHz 10 V RMS AM 80%, 1 khz sinus Passed * Tested with + 20 % Power frequency magnetic field Voltage dips and interruptions EN 61000-4-8: 1994 - A/m 50 Hz Not applicable ** EN 61000-4-11: 1995 * Test not within the scope of the accreditation. Residual voltage Time 0 % 20 ms 40 % 200 ms 70 % 500 ms 0 % 5 s Passed Passed Passed Passed ** Not applicable since the EUT does not contain any devices that are sensitive to the specified level of magnetic field. Dectron test report 09006 Page 4 of 23

Measurements uncertainties Report no: 09006 The reported expanded uncertainty U lab is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance with the documents CISPR16-4-2 and UKAS LAB34. Conducted disturbance, mains terminals ± 2,9 db Radiated disturbance measured in Semi Anechoic Chamber (SAC) 30-200 MHz horizontal polarisation ± 9,0 db vertical polarisation ± 7,7 db 200-1 000 MHz horizontal polarisation ± 3,7 db vertical polarisation ± 5,3 db Radiated disturbance measured in Weather Protected Open Area Test Site (OATS) 30-200 MHz horizontal polarisation ± 3,5 db vertical polarisation ± 5,6 db 200-1 000 MHz horizontal polarisation ± 3,9 db vertical polarisation ± 5,1 db Compliance or non-compliance with a disturbance limit is determined according to the following, quoted from CISPR 16-4-2:2003. If U lab is less or equal to U cispr then: compliance is deemed to occur if no measured disturbance exceeds the disturbance limit; non-compliance is deemed to occur if any measured disturbance exceeds the disturbance limit. If U lab is greater than U cispr then: compliance is deemed to occur if no measured disturbance, increased by (U lab -U cispr ), exceeds the disturbance limit; non-compliance is deemed to occur if any measured disturbance, (U lab -U cispr ), exceeds the disturbance limit. The expanded uncertainty U cispr is for: conducted disturbance, mains port 150 khz 30 MHz ±3,6 db radiated disturbance, 30 1 000 MHz ±5,2 db Dectron test report 09006 Page 5 of 23

Conducted disturbance test set-up Report no: 09006 Dispenser system Accurate speedcontrol BM/ Measuring performed in Semi Anechoic Chamber (SAC) Bonded to wall Plan view for tabletop equipment Table Wall of screened room AMN EUT Mains lead 80 cm 40 cm Dectron test report 09006 Page 6 of 23

Radiated disturbance test set-up Report no: 09006 Dispenser system Accurate speedcontrol BM/ Measuring is performed in Semi Anechoic Chamber (SAC) with antenna distance 3 m. Left picture shows front view and corresponds to azimuth 0. Rotation is made clockwise up to 360 at peak search. Pre-scan with PK-detector is made at antenna height 1.3 m, 0 and 90 azimuth and horizontal and vertical antenna polarisation. Worst-case is shown in graph. The reported QP-values in the table represents worst-case found by rotating the EUT between 0 and 360 azimuth and varying the antenna height between 1 and 4 m and changing the antenna polarisation between horizontal and vertical. Deviation from standard: The used SAC is non-compliant with the NSA requirements of ±4 db according to CISPR 16-1 in the frequency range 30-200 MHz. Dectron test report 09006 Page 7 of 23

Immunity test equipment Report no 09006 Signal generator 9 khz - 2.4 GHz Marconi 2024 Signal generator 9 khz - 3.3 GHz Rohde & Schwarz SML03 RF power amplifier 10 khz - 250 MHz, 75 W Amplifier Research 75A250 RF power amplifier 25-1 000 MHz, 30 W Amplifier Research 30W1000M7 HF power amplifier dual band 1-4 GHz, 30/17 W Milmega AS0104-3017 Electromagnetic field strength meter 20 Hz - 18 GHz PMM 8051 Optical repeater PMM 8051 OR-1 E-field probe 500 khz - 3 GHz, max 120 V/m PMM BA-01 E-field probe 10 MHz - 1 GHz, max 30 V/m PMM BA-05 Level control 10 khz - 1 GHz Amplifier Research 888 Bilog antenna 30 MHz - 1GHz Chase CBL 6111B Bilog antenna 30 MHz - 3 GHz Chase CBL 6112A Double ridged broadband horn antenna 0.7 6.5 GHz Schwarzbeck BBHA 9120 LFA ESD simulator 0.2-16.5 kv (EN 61000-4-2) Schaffner NSG 435 Fast transient/burst generator (EN 61000-4-4) Schaffner NSG 2025 Capacitive clamp (EN 61000-4-4) Schaffner CDN 126 Surge pulse generator, 1.2/50, 8/20 (EN 61000-4-5) Schaffner NSG 2050 / PNW 2050 Pulse coupling network, 1 & 3 phase (EN 61000-4-5) Schaffner CDN 131/133 Used Pulse coupling network, signal line 40 Ω (EN 61000-4-5) Schaffner CDN 116 Coupling network 150 khz - 230 MHz (EN 61000-4-6) Schaffner CDN 516S EM injection clamp 10 khz - 1 GHz (EN 61000-4-6) FCC F2031 S/N 215 Power frequency and pulse magnetic field (EN 61000-4-8/9) Magnetic coil / Schaffner NSG 2050 / Combi generator, burst, surge, voltage dips (EN 61000-4-11) Schaffner Best Plus Pulse coupling network (EN 61000-4-4, -5) Schaffner CDN 135 5 kva AC power source (EN 61000-3-13) Schaffner NSG 1007 Load dump pulse generator (ISO 7637-2 test pulse 5) Temperature and humidity measurement instrument Testo 615 Oscilloscope DC - 100 MHz, 500Ms Tektronix THS720 STD Oscilloscope DC - 300 MHz, 2,5 Gs Tektronix TDS 3032 Linear power supply 24 Vdc 10 A SF 10A-230 Rotating table / Moving antenna ±180 / 1-4 m, hor & vert polarisation / Screen room 1.8 x 1.8 x 2.4 m for measuring equipment SAC, Semi Anechoic Chamber OATS, Open Area Test Site In situ measurement at.. Siemens 10 x 5 x 5 m 8 x 15 x 5 m Dectron test report 09006 Page 8 of 23

Emission test equipment Report no 09006 Measuring system 5 Hz - 1 GHz Rohde & Schwarz ESS Measuring system 9 khz 2.5 GHz Rohde & Schwarz ESPC Spectrum analyser 9 khz - 1.8 GHz Tektronix 2712 Used Mains equivalent 5 μh//50 Ω, 160 A Rohde & Schwarz ESH 3-Z6 Mains equivalent 50 μh//50 Ω, 2 x 16 A Rohde & Schwarz ESH 3-Z5 Mains equivalent 50 μh//50 Ω, 4 x 25 A Rohde & Schwarz SH 2-Z5 Mains equivalent 50 μh//50 Ω, 4 x 100 A FCC-LISN-50-100-4 Absorbing clamp 30-1000 MHz Rohde & Schwarz MDS-21, s/n 893668/012 Absorbing clamp 30-300 MHz R&S MDS 9, s/n 69087 Bilog antenna 30 MHz - 1 GHz Chase CBL6111B Bilog antenna 30 MHz - 3 GHz Chase CBL6112A Double ridged broadband horn antenna 0,7 6,5 GHz Schwarzbeck BBHA 9120 LFA Active antenna 30Hz - 50 MHz Emco 3301B Triple loop antenna 2M, 9 khz - 30 MHz Rohde & Schwarz HM 020 Control unit Rohde & Schwarz BG 020 Balance-to-unbalance transformer, 150 khz - 1.605 MHz Acc to CISPR 15 Fig A.2a Pulse limiter 10 db Rohde & Schwarz ESH 3-Z2 Current probe, 9 khz - 30 MHz Rohde & Schwarz ESH 2-Z1 Voltage probe 1500 Ω, 9 khz - 30 MHz, -29 db Emco 3701 Line Probe acc. to CISPR Harmonics & flicker test system (EN 61000-3-2, -3) Schaffner ProfLine 2100 (CCN 1000 + NSG1007) Harmonic current meter (EN 61000-3-2) Fluke 41 / 43 / Measuring receiver 85 khz - 30 MHz Schwarzbeck FSME 1515 Discontinuous interference analyzer Chase DIA 1500, Ser. No. 1523 Oscilloscope DC - 100 MHz, 500 Ms Tektronix THS720STD Oscilloscope DC - 300 MHz, 2,5 Gs Tektronix TDS 3032 Linear DC power supply 0-350 V, 7 A NT-97 Power supply 0-30 Vdc 10 A (SMPS) Delta Elektronika MST 030-10 Power supply 24 Vdc 10 A (Linear) SF 10A-230 Battery 12 V 60 Ah / 12 V 60 Ah / Rotating table / Moving antenna ± 180 / Height 1-4 m, hor & vert polarization / Screen room 1.8 x 1.8 x 2.4 m for measuring equipment SAC, Semi Anechoic Chamber OATS, Open Area Test Site In situ measurement at Siemens 10 x 5 x 5 m 8 x 15 x 5 m Dectron test report 09006 Page 9 of 23

EN 61000-4-2: Electrostatic discharge (ESD) immunity test Report no 09006 EUT Dispenser system Accurate speedcontrol BM/ Test voltage (kv) Contact discharge 2 4 6 8 Special Test voltage (kv) Air discharge 2 4 8 15 Special Note 10 discharges each of positive and negative polarity. Temperature 23 C (15-35 C) Relative humidity 28 % * (30-60 %) *) Outside specified range according to the standard. Test result The test results may be classified on the basis of the operating conditions and the functional specifications of the equipment under test, according to the following performance criteria: A. Normal performance within the specification limits. B. Temporary degradation or loss of function or performance, which is recoverable. C. Temporary degradation or loss of function or performance, which requires operator intervention or system reset. D. Degradation or loss of function, which is not recoverable, due to damage of equipment (components). Required criterion for compliance: B Passed Not passed Notes It has been demonstrated that the ESD generator meets the specified requirements in the standard with at least a 95% confidence. Visual control of function of EUT. Criteria for normal performance: See head note. Test points shown in picture. Tested by Tobias Gustavsson Date 2009-01-23 Dectron test report 09006 Page 10 of 23

EN 61000-4-3: Radiated radio frequency electromagnetic field immunity test Report no 09006 EUT Dispenser system Accurate speedcontrol BM/ Test field strength Frequency range Frequency step Dwell time Test result 10 V/m 80-2 700 MHz 1 % 3 s Vertical and horizontal polarisation. Amplitude modulation 80 %, 1 khz, sinusoidal. Pulse modulation 100 %, 200 Hz (850-950 MHz, GSM). Level 20 V/m. Pulse modulation 100 %, 1 Hz, 50% duty cycle. The test results may be classified on the basis of the operating conditions and the functional specifications of the equipment under test, according to the following performance criteria: A. Normal performance within the specification limits. B. Temporary degradation or loss of function or performance, which is recoverable. C. Temporary degradation or loss of function or performance, which requires operator intervention or system reset. D. Degradation or loss of function, which is not recoverable, due to damage of equipment (components). Required criterion for compliance: A Passed Not passed Notes All tests performed with 2 V/m above specified test level. Visual control of function of EUT with video camera. Criteria for normal performance: See head note. Tested by Tobias Gustavsson Date 2009-01-22 Dectron test report 09006 Page 11 of 23

EN 61000-4-4: Electrical fast transient/burst immunity test Report no 09006 EUT Dispenser system Accurate speedcontrol BM/ Test voltage Couplers Note 2 kv N+L1 1 kv Capacitive clamp Duration 1 min Frequency 5 khz Repetition rate 300 ms Positive and negative polarity Test result The test results may be classified on the basis of the operating conditions and the functional specifications of the equipment under test, according to the following performance criteria: A. Normal performance within the specification limits. B. Temporary degradation or loss of function or performance, which is recoverable. C. Temporary degradation or loss of function or performance, which requires operator intervention or system reset. D. Degradation or loss of function, which is not recoverable, due to damage of equipment (components). Required criterion for compliance: B Passed Not passed Notes It has been demonstrated that the burst generator meets the specified requirements in the standard with at least a 95% confidence. Visual control of function of EUT. Criteria for normal performance: See head note. Mains input tested in coupling unit. Remote control cable tested in capacitive clamp. Tested by Ulf Heiding Date 2009-01-22 Dectron test report 09006 Page 12 of 23

EN 61000-4-5: Surge immunity test Report no 09006 EUT Dispenser system Accurate speedcontrol BM/ Test voltage Couplers Note 0.5 kv, 1 kv (line to line, R I 2 Ω) - kv (line to earth, R I 12 Ω) L1-N - 5 positive and 5 negative surges Synchronous at 90, 180 and 270 degrees Repetition rate 10 s * (* deviation from standard) Test result The test results may be classified on the basis of the operating conditions and the functional specifications of the equipment under test, according to the following performance criteria: A. Normal performance within the specification limits. B. Temporary degradation or loss of function or performance, which is recoverable. C. Temporary degradation or loss of function or performance, which requires operator intervention or system reset. D. Degradation or loss of function, which is not recoverable, due to damage of equipment (components). Required criterion for compliance: B Passed Not passed Notes It has been demonstrated that the surge generator meets the specified requirements in the standard with at least a 95% confidence. Visual control of function of EUT. Criteria for normal performance: See head note. Tested by Ulf Heiding Date 2009-01-22 Dectron test report 09006 Page 13 of 23

EN 61000-4-6: Induced radio frequency field immunity test Report no 09006 EUT Dispenser system Accurate speedcontrol BM/ Test field strength Frequency range Frequency step Dwell time 10 V 0,15-80 MHz 1 % 3 s Continuous wave. Amplitude modulation 80 %, 1 khz, sinusoidal. Pulse modulation 100 %, 1 Hz, 50% duty cycle. Test result The test results may be classified on the basis of the operating conditions and the functional specifications of the equipment under test, according to the following performance criteria: A. Normal performance within the specification limits. B. Temporary degradation or loss of function or performance, which is recoverable. C. Temporary degradation or loss of function or performance, which requires operator intervention or system reset. D. Degradation or loss of function, which is not recoverable, due to damage of equipment (components). Required criterion for compliance: A Passed Not passed Notes All tests performed with 2 V above chosen test level. Visual control of function of EUT. Criteria for normal performance: See head note. Mains input tested in CDN516. Remote control cable tested in EM-clamp. Tested by Tobias Gustavsson Date 2009-01-22 Dectron test report 09006 Page 14 of 23

EN 61000-4-11: Voltage dips and short interruptions immunity test Report no 09006 EUT Dispenser system Accurate speedcontrol BM/ Residual voltage Cycles Time 0 % 40 % 70 % 0 % 1 20 ms 10 200 ms 25 500 ms 250 5 s Required performance criterion B C C C Test result criterion A A A C Each test repeated 3 times with 30 seconds interval. Test result The test results may be classified on the basis of the operating conditions and the functional specifications of the equipment under test, according to the following performance criteria: A. Normal performance within the specification limits. B. Temporary degradation or loss of function or performance, which is recoverable. C. Temporary degradation or loss of function or performance, which requires operator intervention or system reset. D. Degradation or loss of function, which is not recoverable, due to damage of equipment (components). Required criterion for compliance: See above Passed Not passed Notes Visual control of function of EUT. Mains = 229.3 Vac. Criteria for normal performance: See head note. Tested by Ulf Heiding Date 2009-01-22 Dectron test report 09006 Page 15 of 23

Dectron EMC-Lab RFI Voltage Report No: 09006-01 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, < 36 W, speed: 100%, free running Tobias Gustavsson EN 61000-6-3 Nordic power model 0055 24Vdc, 1,5A 20 jan 2009 14:40 Result File: 09006-01.dat : Oina VV AB, Accurate speedcontrol BM/FMI, cond Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150kHz 30MHz 0,8% 10kHz PK+AV 2msec Auto ON 60dB Transducer No. Start Stop Name 1 1 9kHz 30MHz P_limiter_13 2 9kHz 30MHz Cable_46_48 21 9kHz 30MHz LISN_14_1_fas Final Measurement: Detectors: X QP / + AV Meas Time: Subranges: Acc Margin: 1sec 25 17 db dbµv 100 QP AV 90 80 70 60 50 40 30 20 10 0 0,15 1,0 10,0 30,0 MHz PAGE 1 Dectron test report 09006 Page 16 of 23

Dectron EMC-Lab RFI Voltage Report No: 09006-01 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, < 36 W, speed: 100%, free running Tobias Gustavsson EN 61000-6-3 Nordic power model 0055 24Vdc, 1,5A 20 jan 2009 14:40 Result File: 09006-01.dat : Oina VV AB, Accurate speedcontrol BM/FMI, cond Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150kHz 30MHz 0,8% 10kHz PK+AV 2msec Auto ON 60dB Transducer No. Start Stop Name 1 1 9kHz 30MHz P_limiter_13 2 9kHz 30MHz Cable_46_48 21 9kHz 30MHz LISN_14_1_fas Final Measurement: Detectors: X QP / + AV Meas Time: Subranges: Acc Margin: 1sec 25 17 db Final Measurement Results Frequency MHz QP Level dbµv QP Limit dbµv QP Delta db Phase - PE - 8,2554 39,34 60,00 20,66 N fl Frequency MHz AV Level dbµv AV Limit dbµv AV Delta db Phase - PE - 0,31723 34,86 49,78 14,92 N fl 0,42263 35,20 47,40 12,20 L1 fl 0,52826 35,03 46,00 10,97 L1 fl 0,63452 36,25 46,00 9,75 L1 fl 0,73824 29,70 46,00 16,30 L1 fl 8,2554 29,67 50,00 20,33 L1 fl 8,65968 25,73 50,00 24,27 N fl * limit exceeded Indicated Phase/PE shows Configuration of max. Emission PAGE 2 Dectron test report 09006 Page 17 of 23

Dectron EMC-Lab RFI Voltage Report No: 09006-02 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, < 36 W, speed: 50%, free running Tobias Gustavsson EN 61000-6-3 Nordic power model 0055 24Vdc, 1,5A 20 jan 2009 14:34 Result File: 09006-02.dat : Oina VV AB, Accurate speedcontrol BM/FMI, cond Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150kHz 30MHz 0,8% 10kHz PK+AV 2msec Auto ON 60dB Transducer No. Start Stop Name 1 1 9kHz 30MHz P_limiter_13 2 9kHz 30MHz Cable_46_48 21 9kHz 30MHz LISN_14_1_fas Final Measurement: Detectors: X QP / + AV Meas Time: Subranges: Acc Margin: 1sec 25 17 db dbµv 100 QP AV 90 80 70 60 50 40 30 20 10 0 0,15 1,0 10,0 30,0 MHz PAGE 1 Dectron test report 09006 Page 18 of 23

Dectron EMC-Lab RFI Voltage Report No: 09006-02 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, < 36 W, speed: 50%, free running Tobias Gustavsson EN 61000-6-3 Nordic power model 0055 24Vdc, 1,5A 20 jan 2009 14:34 Result File: 09006-02.dat : Oina VV AB, Accurate speedcontrol BM/FMI, cond Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 150kHz 30MHz 0,8% 10kHz PK+AV 2msec Auto ON 60dB Transducer No. Start Stop Name 1 1 9kHz 30MHz P_limiter_13 2 9kHz 30MHz Cable_46_48 21 9kHz 30MHz LISN_14_1_fas Final Measurement: Detectors: X QP / + AV Meas Time: Subranges: Acc Margin: 1sec 25 17 db Final Measurement Results Frequency MHz QP Level dbµv QP Limit dbµv QP Delta db Phase - PE - 0,53249 38,19 56,00 17,81 L1 fl Frequency MHz AV Level dbµv AV Limit dbµv AV Delta db Phase - PE - 0,31977 33,00 49,71 16,71 N fl 0,42601 33,94 47,33 13,39 L1 fl 0,53249 34,87 46,00 11,13 L1 fl 0,63959 30,78 46,00 15,22 L1 fl 0,74414 27,80 46,00 18,20 L1 fl 0,85209 21,57 46,00 24,43 L1 fl 8,0604 25,52 50,00 24,48 L1 fl * limit exceeded Indicated Phase/PE shows Configuration of max. Emission PAGE 2 Dectron test report 09006 Page 19 of 23

Dectron EMC-Lab RFI Field Report No: 09006-11 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Result File: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, <36W, speed 100%, free running Ulf Heiding EN 61000-6-3 QP-values are measured at worst case regarding to antenna height, polarization and EUT azimuth. Field measuring in screened room damped with ferrites and absorbers. Dist. 3 m. 09006-11.dat : Oina VV AB, Accurate speedcontrol BM/FMI, rad 19 jan 2009 16:16 Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 30MHz 1000MHz 0,1% 120kHz PK 1msec Auto ON 60dB Transducer No. Start Stop Name 1 1 30MHz 1000MHz Cables_47_49 21 30MHz 1000MHz CBL6112_d Final Measurement: Detector: X QP Meas Time: Subranges: Acc Margin: 1sec 25 12 db dbµv/m 80 _6_3 70 60 50 40 30 20 10 0 30,0 100,0 1000,0 MHz PAGE 1 Dectron test report 09006 Page 20 of 23

Dectron EMC-Lab RFI Field Report No: 09006-11 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Result File: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, <36W, speed 100%, free running Ulf Heiding EN 61000-6-3 QP-values are measured at worst case regarding to antenna height, polarization and EUT azimuth. Field measuring in screened room damped with ferrites and absorbers. Dist. 3 m. 09006-11.dat : Oina VV AB, Accurate speedcontrol BM/FMI, rad 19 jan 2009 16:16 Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 30MHz 1000MHz 0,1% 120kHz PK 1msec Auto ON 60dB Transducer No. Start Stop Name 1 1 30MHz 1000MHz Cables_47_49 21 30MHz 1000MHz CBL6112_d Final Measurement: Detector: X QP Meas Time: Subranges: Acc Margin: 1sec 25 12 db Final Measurement Results Frequency MHz QP Level dbµv/m QP Limit dbµv/m QP Delta EUT Azimuth Ant. height Ant. pol. db deg m 32,5298 22,70 40,00 17,30 5 1,0 ver 71,1482 19,78 40,00 20,22 35 1,0 ver 114,1518 18,34 40,00 21,66 0 1,0 ver 116,5731 17,74 40,00 22,26 10 1,0 ver 138,8552 17,38 40,00 22,62 350 1,0 ver * limit exceeded PAGE 2 Dectron test report 09006 Page 21 of 23

Dectron EMC-Lab RFI Field Report No: 09006-12 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Result File: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, <36W, speed 50%, free running Ulf Heiding EN 61000-6-3 QP-values are measured at worst case regarding to antenna height, polarization and EUT azimuth. Field measuring in screened room damped with ferrites and absorbers. Dist. 3 m. 09006-12.dat : Oina VV AB, Accurate speedcontrol BM/FMI, rad 19 jan 2009 16:37 Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 30MHz 1000MHz 0,1% 120kHz PK 1msec Auto ON 60dB Transducer No. Start Stop Name 1 1 30MHz 1000MHz Cables_47_49 21 30MHz 1000MHz CBL6112_d Final Measurement: Detector: X QP Meas Time: Subranges: Acc Margin: 1sec 25 12 db dbµv/m 80 _6_3 70 60 50 40 30 20 10 0 30,0 100,0 1000,0 MHz PAGE 1 Dectron test report 09006 Page 22 of 23

Dectron EMC-Lab RFI Field Report No: 09006-12 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: Result File: Accurate Speedcontrol BM/FMI Oina VV AB 230 Vac 50 Hz, <36W, speed 50%, free running Ulf Heiding EN 61000-6-3 QP-values are measured at worst case regarding to antenna height, polarization and EUT azimuth. Field measuring in screened room damped with ferrites and absorbers. Dist. 3 m. 09006-12.dat : Oina VV AB, Accurate speedcontrol BM/FMI, rad 19 jan 2009 16:37 Scan Settings (1 Range) Frequencies Receiver Settings Start Stop Step IF BW Detector M-Time Atten Preamp OpRge 30MHz 1000MHz 0,1% 120kHz PK 1msec Auto ON 60dB Transducer No. Start Stop Name 1 1 30MHz 1000MHz Cables_47_49 21 30MHz 1000MHz CBL6112_d Final Measurement: Detector: X QP Meas Time: Subranges: Acc Margin: 1sec 25 12 db Final Measurement Results Frequency MHz QP Level dbµv/m QP Limit dbµv/m QP Delta EUT Azimuth Ant. height Ant. pol. db deg m 30,7898 23,14 40,00 16,86 320 1,0 ver 71,0062 19,32 40,00 20,68 355 1,0 ver 78,5485 17,45 40,00 22,55 355 1,3 ver 113,81 24,23 40,00 15,77 50 2,7 hor 115,2985 25,18 40,00 14,82 55 2,8 hor * limit exceeded PAGE 2 Dectron test report 09006 Page 23 of 23