Compact Excavator Pipe Rupture Valve

Similar documents
Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

COUNTERBALANCE VALVES

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Chapter 5: Flow Valves

3/2 Solenoid Cartridge Valve, Size 6

Pressure reducing valve, direct operated, Type ZDR 6 D

Open center control block in monoblock design MO-40

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief Valves SPV, SPVF

Seat Valves. 1 Description. Series SVH Technical data. 1.2 Performance graphs

PUMP AND MOTOR DIVISION

2-way flow control valve Type 2FRM 6

Variable Displacement Pump AA10VSO

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Check Valves Valve locator

Chapter 6: Check Valves

Flow divider (flow distributor), type TQ

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Rexroth Hydraulic Pump A10VO Series User Manual

Example. Fluid Power. Circuits

Series PVP Variable Volume Piston Pumps

Pressure Relief and Regulating Valves

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Vickers. Piston Pumps

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Pressure relief valves Size 6

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Unit 24: Applications of Pneumatics and Hydraulics

2/2 and 3/2 Way Size 6 Seat Valves

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Hydraulic Flow Control Valves

Control block EDD Modular Directional Valve

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Line rupture protection valves type LB

Unit 24: Applications of Pneumatics and Hydraulics

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

PART 2 FORKLIFT HYDRAULIC SYSTEM

Plunger Cylinder. 1 Description. 2 Technical data

KDG3V-5/7/8, 10 Series

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Fixed displacement vane pumps

Hydraulic control unit series

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

PRESSURE REDUCING CONTROL VALVE

ACCUMULATOR INSTALLATION

3/2- and 2/2-way cartridge valve type BVE

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Axial Piston Fixed Displacement Motor A2FM

PVH131/141 Variable Displacement Piston Pump - 11 Design

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Dual Path Mobile Pump

Unit 24: Applications of Pneumatics and Hydraulics

IMPORTANT DOCUMENTATION DO NOT DISCARD!

FILLING AND PURGING THE SYSTEM

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

4/2-Way Pneumatic Solenoid Valve

MANTA Piston Distributor for Oil and Fluid Grease

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Load-sensing control block in mono and sandwich plate design

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

NEM at a glance Company, product index.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

15/40/80CN Series Medium Pressure Filters

Series TMM Axial Piston Motor. Technical Information

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Control blocks for two-hand start ZSB

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Table of Contents. M Series Variable Displacement Piston Pumps

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

LOADER DIRECTIONAL CONTROL VALVE LV LV22RFSTKLB SHOWN T

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Transcription:

Compact Excavator Pipe Rupture Valve Series Reference: Classification: 430.325.355 1/11

Contents Page 1 General description................................................................ 3 2 dvantages........................................................................ 3 3 pplication........................................................................ 3 4 Technical data..................................................................... 4 5 Installation/startup................................................................. 5 5.1 Installation information......................................................... 5 5.2 djustment information......................................................... 5 6 Description of function............................................................. 6 7 Port designations.................................................................. 8 8 Circuit example.................................................................... 8 9 Standard design, sizes 16/20........................................................ 9 9.1 Dimensions.................................................................. 9 9.2 Performance graphs........................................................... 9.3 Model code key............................................................... 11 2/11

1 General description In accordance with standard EN 474 5 "Safety of earth moving machinery Requirements for hydraulic excavators", the excavator pipe rupture valve, type (Compact Flow Control and Safety Valve), prevents uncontrolled lowering of the actuator in the event of a pipe or hose rupture. In addition, the valve holds the actuator in its position when the main valve is centred. The valve also includes a secondary pressure relief function, which protects the actuator against overload. 2 dvantages The inlet and actuator ports on the CSF excavator pipe rupture valve are standard SE flanged ports, and the valve can therefore be retrofitted to existing equipment without any difficulty. Thanks to its load independent, pilot operated opening principle, variations in load pressure even right up to the maximum have no effect on the fine control characteristics and the hydraulic performance of the valve. The design of the valve means that it can be operated by very small lowering pressures. The CSF is set at the machine in a way that ensures that the excavator pipe rupture function has no effect on the hydraulic values that have already been set in the machine (pre opening principle). This means that excavators with and without a lifting function can be equipped with the same basic hydraulic system; the machines work cycles remain unchanged. The secondary pressure relief function can handle the full rated flow. When the main spool valve is a closed centre model and a secondary valve is connected in parallel, no pressure summing occurs. The secondary pressure relief valve in the excavator pipe rupture valve opens at exactly the opening pressure that has been set. There is no need for a large bore, external tank return line. 3 pplication The excavator pipe rupture valve is used wherever so required by the standards EN 474, ISO 8643 and DIN 24093 for excavators with a lifting device (e.g. a load hook on the bucket. The actuators concerned are the lift cylinder, the stick cylinder and the adjusting cylinder. It is also possible to envisage machine applications in which a pipe rupture on the actuators could produce dangerous situations e.g. machines for materials handling and demolition. ttention: the excavator pipe rupture valve may only be used for the purpose for which it has been designed! 3/11

4 Technical data General characteristics Design Mounting method Mounting attitude Flow direction Weight Description, value, unit 2 stage proportionally controlled seat valve, with initial hydraulic decompression patented follower principle flange mounting, SE 6000 psi unrestricted free flow through check valve controlled flow 3.6 kg Hydraulic characteristics Description, value, unit Nominal sizes 16 20 Nominal flow rate size 16 = 250 l/min size 20 = 350 l/min Pilot pressure range opening pressure 4 12 bar (adjustable) full opening opening pressure + 18 bar + leakage oil pressure Operating pressure Secondary PRV adjustment range Operating fluid Temperature range, seal material Viscosity range max. 420 bar min. 320 420 bar (max. up to 460 bar also possible); settings are sealed other models consult ucher Hydraulics mineral oil to DIN 51524 and DIN 51525 (HL/ HLP), other fluids consult ucher Hydraulics Nitrile = 20 C +90 C Viton = 20 C +200 C Low (N7T40) = 50 C +80 C minimum 2.8 mm 2 /s (cst)... maximum 1500 mm 2 /s (cst) recommended mm 2 /s (cst) 380 mm 2 /s (cst) Filtration NS 1638 class 9, ß 75 ISO 4406 class 18/15 (valves do not have any internal filters) Ports SE Description, value, unit to SE J518 DEC87 Threads to DIN 3852, Parts 1 and 2 Fittings to ISO 8434 1 4/11

5 Installation/startup 5.1 Installation information ttention: only trained and competent personnel may carry out any work on the excavator pipe rupture valve! The valve must not be opened without the manufacturer s express permission! Mounting bolts can be supplied as an optional extra and are grade 12.9 to DIN 912, with "Geomet" surface finish. Protect flange faces from damage and before installing the valve check that all the seals are present. The mating flange face must be of the quality specified in the catalogue. efore initial start up, bleed all air from the hydraulic system. Do not use any pipe fittings that have tapered threads. ttention: before removing or disassembling the valve, vent all hydraulic pressure from the system double check! 5.2 djustment information Pilot valve for main function The pilot valve for the lowering function is factory set during testing to the opening pressure stipulated by the customer and then sealed. clockwise increases the pressure counterclockwise decreases the pressure The change in pressure is approx. 5.8 bar per turn. ttention: the adjusting screw can be completely unscrewed it has no end stop! Important: if the adjustment seal is broken, the warranty is null and void! Pilot valve for pressure relief function The pilot valve for the pressure relief function is factory set during testing to the pressure stipulated by the customer and then sealed. The pressure is set with flow Q = approx. 0.75 l/min. clockwise increases the pressure counterclockwise decreases the pressure ttention: the adjusting screw can be completely unscrewed it has no end stop! Important: if the adjustment seal is broken, the warranty is null and void! The change in pressure is approx. 94 bar per turn. (with the spring for 320 420 bar) 5/11

6 Description of function 8 7 2 4 9 X 6 1 5 11 3 Fig. 1 300 4 012929 1 CV spring 2 Control spring 3 Spring for secondary valve 4 djusting screw for pilot valve 8 Pilot piston 9 Stroke limiter djusting screw for secondary valve 11 Emergency lowering screw 5 Poppet for secondary valve 6 Control spool 7 Pilot spool C The load control assembly Pilot valve for load control assembly Pilot valve for secondary pressure relief The neutral position (load pressure at ; and X unpressurised) In the neutral position, the excavator pipe rupture valve is held closed by the spring (2), which acts on the control spool (1), and also by the load pressure, which acts on the rear side of the control spool. The check valve function (flow ) To raise the actuator, pump pressure is applied via port to the valve seat area of the control spool (6) and causes the control spool to open, pushing against the light spring (1). The control function (flow ) 1. Decompression The pilot pressure at port X moves the pilot piston (8) in opposition to the springs (2) and the pilot spool (7) opens at the set pressure. The load pressure behind the control spool (6) now decays as it escapes past the pilot spool to port. The progressive characteristic of the decompression phase ensures that the actuator motion begins smoothly and without jerks. 6/11

2. Main opening With further increase in the pilot pressure at X, the pilot spool opens further and the reduced pressure behind the control spool falls still more. The load pressure acting on the differential area of the control spool now pushes the spool off its valve seat in the opening direction until the pressures of the oilflows into, and out of, the control spool have changed enough to produce a situation of force balance. The pilot pressure acting on the pilot piston therefore controls the open metering area of the control spool, and consequently the flow rate from. The pilot valve is compensated and is unaffected by any back pressure in port that may occur. The opening point of each excavator pipe rupture valve is precisely matched to the particular make/model of excavator and is set to the required value on the test stand with adjusting screw (4). With the optional stroke limiter (9), the pilot spool stroke can also be restricted. This in turn influences the lowering speed. Function of the secondary pressure relief valve The pilot valve for the pressure relief valve is connected directly to actuator port. When the pressure set with spring (3) is reached, the poppet (5) opens and unloads the rear side of the control spool (6) to port L. The load pressure, acting on the differential area of the control spool, now pushes the spool fully open and opens the to flow path for the full rated flow. The pilot valve is not connected to the return line and is therefore unaffected by any back pressure in port that may occur. With a closed centre directional valve, no pressure summing occurs with the necessary series connected downstream pressure relief valve. The secondary pressure can be set at any desired level with the adjusting screw (). ttention: when the pilot valve for the secondary pressure relief function opens, there is a pilot flow of 9 l/min per valve to port L. To ensure that the performance characteristics are not affected, the drain line should be sized so that the back pressure never exceeds bar. Leakage oil drain The leakage oil from both pilot cartridges as well as their spring chambers is drained to port L. This port should be drained to tank with the least possible back pressure. ny tank preload or back pressure in the drain line has a 1:1 effect on the opening values of both pilot valves. Emergency lowering screw L n optional emergency lowering screw (11) can be incorporated. The actuator is vented to port L through a ø3 connecting drilling that is normally shut off. The screw cannot be completely unscrewed. ttention: when emergency lowering has been completed, the screw must be screwed in again to restore the valve s function! 7/11

7 Port designations Port X Description ctuator/load port Flow or return port Pilot port L, L1 Drain port E, E1 Port for balance pipe in parallel cylinder applications; protected by a ø1 fixed orifice 8 Circuit example Ø1 1 E1 E 2 3 X L L1 Fig. 2 300 4 012146 1 Version with optional balance valve 2 Version with optional emergency lowering 3 Version with optional stroke limiter 8/11

9 Standard design, sizes 16/20 9.1 Dimensions R max 0.02 / 0 mm E1 40.5 52.5 E 4 137.5...141 3 31 31 14 128...131 3 X L1 E1 2 L E 3.5 31.5 72 97 b c a 88.5 131.5...133 25.5 54 85.5 37.5 E 40.5 40.5 Fig. 3 300 4 012889 89 E1 4 21 1 E E1 1 Version with optional balance valve Fitting, type 8S, for cutting ring to DIN 3861 2 Version with optional emergency lowering 3 Version with optional stroke limiter 4 Serial number Required quality of the mating surface Design Ports Dimensions X, L, L1, E, E1 a b c 16 SE 3/4" 6000 psi SE 3/4" 6000 psi G 1/4" M 15 25 20 SE 1" 6000 psi SE 1" 6000 psi G 1/4" M12 16 24 9/11

9.2 Performance graphs p to = (Q) 20 p to = (Q) 20 15 15 p [bar] p [bar] 5 5 0 0 50 0 150 200 250 300 350 0 0 50 0 150 200 250 300 350 Q [l/min] Q [l/min] Opening curve, Q = (px) at 33 bar load pressure 20 18 16 14 px [bar] 12 8 6 4 2 0 0 20 0 200 300 Q [l/min] Opening curve, Q = (px) at 0 bar load pressure 16 14 12 px [bar] 8 6 4 2 0 0 20 40 60 80 0 Q [l/min] px = pilot pressure [bar] Pressure relief valve, secondary PRV, Q = (Load) (Example curve) 500 * * * 400 * p [bar] 300 200 0 0 0 50 0 150 200 250 300 * pressure setting Q [l/min] /11

9.3 Model code key E S SV Nominal size 16 = 16 20 = 20 Model series Series = pplication Earth moving machines to EN 474, ISO 8643 Design Standard design = E = S Seal material Temperature range Nitrile (standard) 20 C to +90 C = N Nitrile (low temperature) 50 C to +80 C = T Viton (special fluids) 20 C to +200 C = V Mounting bolts Without mounting bolts = O With mounting bolts, surface treated t = D Control spool 0 l/min. = R0 250 l/min. = R250 290 l/min. = R290 Example R0: flow rate = 0 l/min. at 33 bar p Opening point setting Opening pressure... bar at approx. 20 l/min =... [bar] Secondary pressure relief Pressure relief at port Setting of the secondary pressure relief valve Pressure setting... bar at approx. 0.75 l/min Ports X, L, E To DIN 3852 Part 2 (Imperial) Fittings package for X and L (optional) Optional accessories Without balance valve alance valve in port E (parallel operation), port L open alance valve in port E1 (parallel operation), port L1 open = SV =... [bar] = Z = V = R = L Optional mechanical emergency lowering Without emergency lowering = With mechanical emergency lowering = N Optional stroke limiter Without stroke limiter = djustable stroke limiter = H Stroke limiter setting Q setting at 33 bar load pressure =... [l/min] info.nh@bucherhydraulics.com www.bucherhydraulics.com 2006 by ucher Hydraulics G, CH 6345 Neuheim. ll rights reserved. Data is provided for the purpose of product description only, and must not be considered as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. ecause the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. 11/11