is then retained absolutely without interruption.

Similar documents
is then retained absolutely without interruption.

Actuator-Sensor-Interface

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

SITOP UPS1600 / UPS1100. SITOP power supply SITOP UPS1600 / UPS1100. Overview. Safety information. Description, device design, dimension drawing 2

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PHOENIX CONTACT - 01/2007

TX OPEN RS232/485 module

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

I STAR COMPUTER CO., LTD

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

instabus KNX / EIB System System E F G H

Product and functional description

Modular I/O System Analog and Digital Interface Modules

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

SYSTEM DESCRIPTION Termination Boards

Rack mounted telephone- and leased line modem for industrial applications

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

PHOENIX CONTACT Features

Telephone- and leased line modem for industrial applications TD-36

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power Supplies 3. SDN-P DIN Rail Series

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Three-phase monitoring relay CM-PFE

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

PCS0100en Persy Control Services B.V. Netherlands

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Redundancy Module QUINT-DIODE/40

Digital input modules

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

MINI MCR-SL-R-UI(-SP)

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Emergency lighting units EM powerled

How To Use A Power Supply Unit (Upu)

Mobile Data Power Model: MDP-25

DALI RC BASIC SO. Control unit Operating instructions

DLP-PU/E Instruction Manual

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Preset Counter signo 721

User Manual for CH-PFC76810

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

J TB/TW Temperature limiter, temperature monitor

connecdim Gateway G1 Ethernet TCP/IP to DALI

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Drayton Digistat +2RF/+3RF

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

OZS Web server. For LPB/BSB plants

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

VOICE RECORDING SYSTEM ISDN PRI / BRI

TORKEL 820 Battery Load Unit

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Multifunction devices

CompactLogix Power Supplies Specifications

IO-RM3 3-Stage Relay Module

Safety technique. Emergency stop module BO 5988 safemaster

Online UPS. PowerWalker VFI 1000R/1U

Operating Manual UWAPS-TINY Series

RM4TG20 three-phase network control relay RM4-T - range V

Application/Connection Examples

SVR 12/24V and SVR Akku 12V Installation instructions

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

SYSTEM 45. C R H Electronics Design

Duct Humidity Transmitter

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

HCR3.2/.. Chipcard reader HOTEL SOLUTION

38 Series - Relay interface modules A

Uninterruptible Power Supply

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Transcription:

Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 40 A Compact design, only 102 mm wide Completely uninterruptible mains buffering through immediate electronic connection of the battery as soon as the DC UPS input voltage falls below the value set using DIP switches. High level of security and availability through monitoring of availability, battery supply lead, battery ageing (message "Battery replacement required") and battery charge (message "Battery charge >85%") Support for automatic warm restart of industrial PCs through selectable shutdown characteristics. Optionally with USB interface. SW tool available as download at http://www.siemens.com/sitop Executes with WinNT4.0, Win2000 and WinXP. The following diagrams show examples of the timing of the input and output voltages at the terminals of the DC UPS module as well as the timing of the message signals (relays) and of the remote signal (interface). "Long" voltage failure with DC UPS without USB port (Fig. 1) Voltage return only following expiry of buffer time tp (t3 follows t4): Upon failure of the input voltage on the DC UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage V out is then retained absolutely without interruption. The floating changeover contact "o.k./bat" switches over to its off position "Bat". At the same point in time t1, the buffer time tp set on the DIP switches is started automatically. The fact that the DIP switch is set to "Interruption output V out " in this example has no effect because the input voltage returns at time t3 only following expiry of the set buffer time (time t4). "Short" voltage failure with DC UPS without USB port (Fig. 2) Voltage return before expiry of buffer time tp (t3 before t4): Upon failure of the input voltage on the DC UPS module (time t1), the battery "Bat" immediately takes over the DC supply,

Page 2 of 11 and the output voltage V out is then retained absolutely without interruption. The floating changeover contact "o.k./bat" switches over to its off position "Bat". At the same point in time t1, the buffer time tp set on the DIP switches is started automatically. With the DIP switch set to "Interruption output V out ", the output voltage V out is automatically interrupted for 5 s following expiry of the set buffer time tp (time t4). The battery has already been disconnected because the input voltage has returned at the time t3. If the DIP switch is not set to "Interruption output V out " there is no interruption in this example because the input voltage has already returned at time t3 prior to expiry of the set buffer time (time t4). Buffer time (time t4) automatically interrupted for 5 s, and the battery which has not yet been disconnected because of the missing input voltage is simultaneously disconnected from the output. Fig. 1 "Long voltage failure" Fig. 2 "Short voltage failure" DC UPS without USB port (6EP1931-2FC21) DIP switch positions on device: buffer time tp (from 5 to 635 s with bottom row Nos. 2 to 7)//t = according to setting (with bottom row No. 1 to left)/xxxx = with setting for interruption V out (with bottom row No. 8 to left) Legend: V in : input voltage at terminals X1.1 X1.2 V out : output voltage at terminals X1.3 X1.4 and X1.5 - X1.6 ok: signal for input voltage V in OK or above the set battery connection threshold Bat: signal for battery operation (batteries connected to output, batteries power the load)

Page 3 of 11 Remote: signal for remote timer start with signal level = 0 at pin 7 of 9-pin serial port (pin 7 is usually the positive power supply for the port) t1: input voltage V in failed or fallen below set connection threshold t2: buffer time set on DIP switches is started by remote timer start (signal level = 0) t3: input voltage V in rises above set connection threshold t4: end of set buffer time (output is switched off and/or battery is disconnected) t5: output is connected again 5 s after shutdown tp: buffer time set on the DIP switches (bottom row Nos. 2 to 7) "Long" voltage failure with DC UPS with USB port (Fig. 3) Voltage return only following expiry of buffer time tp (t3 follows t4): Upon failure of the input voltage on the DC UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage V out is then retained absolutely without interruption. The floating changeover contact "o.k./bat" switches over to its off position "Bat". The buffer time tp set on the DIP switches is started at the user-selectable time t2 by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial port following previous signal timing according to instruction manual). The fact that the DIP switch is set to "Interruption output V out " in this example has no effect because the input voltage returns at time t3 only following expiry of the set buffer time (time t4). Note: Without a remote signal level = 0 with a setting t = max. duration, there is no interruption in the output voltage in this case because the set buffer time is not started (or interruption only if the exhaustive discharge protection disconnects the battery and the input voltage has not returned by then). "Short" voltage failure with DC UPS with USB port (Fig. 4) Voltage return before expiry of buffer time tp (t3 before t4): Upon failure of the input voltage on the DC UPS module (time t1), the battery "Bat" immediately takes over the DC supply, and the output voltage V out is then retained absolutely without interruption. The floating changeover contact "o.k./bat" switches over to its off position "Bat". The buffer time tp set on the DIP switches is started at the user-selectable time t2 by means of the signal "Remote timer start" (signal level = 0 at pin 7 of the 9-pin serial port following previous signal timing according to instruction manual). With the DIP switch set to "Interruption output V out ", the output voltage V out is automatically interrupted for 5 s following expiry of the set buffer time tp (time t4). The battery has already been disconnected because the input voltage has returned at the time t3. The interruption in the output voltage V out for 5 s permits an automatic restart for many industrial PCs, even if the mains voltage (or the input voltage V in on the DC UPS module) returns during shutdown of the PC as in this example. Note: Without a remote signal level = 0 with a setting t = max. duration, there is no interruption in the output voltage here because the set buffer time is not started.

Page 4 of 11 Fig. 3 "Long voltage failure" Fig. 4 "Short voltage failure" DC UPS with serial or USB port (6EP1931-2FC42) DIP switch positions on device: buffer time tp (from 5 to 635 s with bottom row Nos. 2 to 7)/t = max. time (with bottom row No. 1 to left)/interruption V out (with bottom row No. 8 to left) Legend: V in : input voltage at terminals X1.1 X1.2 V out : output voltage at terminals X1.3 X1.4 and X1.5 - X1.6 ok: signal for input voltage V in OK or above the set battery connection threshold Bat: signal for battery operation (batteries connected to output, batteries power the load) Remote: signal for remote timer start with signal level = 0 at pin 7 of 9-pin serial port (pin 7 is usually the positive power supply for the port) t1: input voltage V in failed or fallen below set connection threshold t2: buffer time set on DIP switches is started by remote timer start (signal level = 0) t3: input voltage V in rises above set connection threshold t4: end of set buffer time (output is switched off and/or battery is disconnected) t5: output is connected again 5 s after shutdown tp: buffer time set on the DIP switches (bottom row Nos. 2 to 7)

Page 5 of 11

Page 6 of 11 DC UPS module 40 A Order No. 6EP1 931-2FC21 6EP1 931-2FC42 (with USB interface) Input L+/ M in normal operation 1) Rated voltage V in rated Voltage range Connection threshold for battery Rated current I in rated Regulated direct voltage 24 V DC 22 to 29 V DC 22.5 V DC ± 0.1 V (factory setting), adjustable in the range 22 to 25.5 V DC (in 0.5-V steps) 40 A + approx. 2.6 A with empty battery Mains buffering Mains buffering time On/off control circuit Buffering time Interruption Dependent on connected battery and load current: with 2x 2) battery module 7 Ah (6EP1935-6ME21) at +25 C: approx. 2 min. at 40 A with 1x battery module 7 Ah (6EP1935-6ME21) at +25 C: approx. 2 min. at 20 A; 15 min. at 10 A; 38 min. at 5 A with 2x 2) battery module 12 Ah (6EP1935-6ME21) at +25 C: approx. 11 min. at 40 A with 1x battery module 12 Ah (6EP1935-6ME21) at +25 C: approx. 11 min. at 20 A; 30 min. at 10 A; 60 min. at 6 A External floating NO contact (max. load 15 V DC / max. 10 ma) required. If the control circuit is open, the battery is separated from the output L+ and the mains buffering is thus interrupted. Adjustable using DIP switch to a maximum buffering time up to forced shutdown through exhaustive discharge protection (at approx. 19 V) or to a time limit of 5 to 635 s (in 10-s steps) Adjustable using DIP switch, either: Interruption in output voltage for min. 5 s following expiry of set buffer time to support automatic restarting of industrial PCs Interruption-free power supply to consumers following return of input voltage Output L+/ M in normal operation

Page 7 of 11 Rated voltage V out rated Voltage range Output current Dynamic current with overload Dynamic current with short-circuit Output +Bat / -Bat in normal operation End-of-charge voltage Load current 24 V DC (output voltage of SITOP power supply) Input voltage Vi less approx. 0.5 V DC 0 to 40 A Electronic shutdown of the output at 1.05 to 1.4 x I out rated after approx. 80 ms with automatic restart attempts (approx. 20 s intervals between restart attempts) Electronic current limiting to 1.5 to 3 x I out rated for approx. 20 ms, then electronic shutdown of the output with automatic restart attempts (approximately 20 s intervals between restart attempts) CVCC charging characteristic (first constant current then constant voltage) 27.0 V DC ± 0.1 V (factory setting), adjustable in the range 26.3 to 29.3 V DC (in 0.1-V steps) Approx. 2 A (factory setting), â adjustable to 1 A or 2 A (charging is carried out with closed and open on/off circuit) Efficiency/heat losses At V out rated, I out rated, approx. With battery operation, approx. 97.2% / 28.6 W 96.9% / 33.6 W Protection and monitoring Polarity reversal protection Overload protection Short-circuit protection Exhaustive discharge protection Against polarity reversal on input voltage and batteries Electronic shutdown of the output at 1.05 to 1.4 x I out rated after approx. 80 ms with automatic restart attempts (approx. 20 s intervals between restart attempts) Electronic current limiting to 1.5 to 3 x I out rated for approx. 20 ms, then electronic shutdown of the output with automatic restart attempts (approximately 20 s intervals between restart attempts). Built-in, non-accessible 64 A fuse Automatic shutdown if battery voltage below approx. 19 V

Page 8 of 11 Monitoring "Open-circuit in battery circuit" Monitoring "Battery replacement required" Monitoring "Battery charge status > 85%" Alarm signal if battery circuit not closed or if it opens during operation (cyclic check approximately every 20 s) Alarm signal flashes at approx. 1/4 Hz (approx. 2 s alarm, approx. 2 s no alarm, approx. 2 s alarm etc.). Checking every 4 hours if no buffering operation or shutdown has occurred. No monitoring is carried out if the compatibility switch position is "On"! Signal to indicate that batteries are charged to at least 85% of rated capacity Signaling 3) Normal operation Buffering or battery operation (battery supplies load alone or in addition to PS in the case of overload) Alarm (backup not ready, or prewarning from < 20.4 V battery voltage) "Battery charge status > 85%" Compatibility switch (only with 6EP1931-2EC21) Green LED (o.k.) and floating changeover contact "24 V DC o.k. / Bat" at setting "24 V DC o.k." 4) Yellow LED (Bat) and floating changeover contact "24 V DC o.k. / Bat" at setting "Bat" (= off position) Red LED (alarm) and floating changeover contact at setting "Alarm" (= off position). Causes for lack of backup readiness during normal operation can include: Off status or open on/off control circuit, battery module not connected, polarity reversal or defective battery (battery voltage < 18.5 V) or open-circuit between battery and UPS module. Scan and thus update of the signal every 20 s. Alarm signal flashing at approx. 1/4 Hz signals that battery replacement is necessary. Causes for lack of availability during buffering can include: Battery voltage has dropped below 20.4 V DC (= prewarning before shutdown through exhaustive discharge protection) as well as shutdown of the battery due to overload, short-circuit, exhaustive discharge protection or expired backup time. The red LED then goes out Second green LED (Bat > 85%) and floating NO contact closed (off position = open) The following can be selected using DIP switches:

Page 9 of 11 Switch position "Off" - "significant properties analogous to new DC UPS range" or "On" - "analogous to previous DC UPS module 40, 6EP1931-2FC01" Compatibility switch position "On": Modified output of alarm signal: - in the event of a wire breakage between the battery module and the DC UPS module, the red LED flashes at 1/3 Hz and the floating changeover contact (alarm) switches at approx.1/3 Hz A battery test is not carried out Optional interface and software USB port Only on 6EP1 931-2FC42 Output of all signals and receipt of signal "Remote timer start". Technical design: Specification 2.0 with full speed, i.e. 2 Mbit/s. Supplied with +5 V by DC UPS ("self- powered"). Required connection to PC: Commercially available 4-core shielded cable, 90 Ohm, max. 5 m, USB series "A" connector to PC and USB series "B" connector to DC UPS Software A software tool (runs under WinNT 4.0, Win 2000 and WinXP) for reading out and processing the signals is available for downloading from the Internet at Control signals http://www.siemens.com/sitop This site also provides more information on the interface. On/off control signal "Remote timer start" via USB port Buffering is terminated or the battery is disconnected from the output by opening the control circuit (or by using DIP switches on the unit). All other functions are retained. Starts mains buffering for the time set Safety Primary/secondary galvanic isolation Protection class (EN 60950) No Class III (ext. circuit and power supply unit: SELV required in accordance with EN 60950) EMC Emitted interference Radio interference suppression in accordance with EN 55022, limit value curve B

Page 10 of 11 Noise immunity Noise immunity in accordance with EN 61000-6-2 Ambient conditions Ambient temperature in operation 0 to +60 C with natural convention Transport/storage temperature -40 to +70 C Degree of protection (EN 60529) Humidity class IP20 Conditions of use in accordance with EN 60721, climate class 3K3 (relative atmospheric humidity 5 to 85% and absolute atmospheric humidity 1 g/m³ to 25 g/m³; no condensation) Approvals CE UL/CSA CE conformity in accordance with 89/336 EEC UL 508 / CSA C22.2, File E197259 Mechanical system Input connections 24 V DC 2 screw-type terminals for 0.33 to 10 mm² / 22 to 7 AWG Output connections 24 V DC 4 screw-type terminals for 0.33 to 10 mm² / 22 to 7 AWG Battery module connections 24 V DC 2 screw-type terminals for 0.33 to 10 mm² / 22 to 7 AWG Connections for control circuit and signals 10 screw-type terminals for 0.5 to 2.5 mm² / 20 to 13 AWG Dimensions (W x H x D) in mm 102 x 125 x 125 Required clearances Weight 50 mm above the unit and 50 mm below the unit Approx. 1.1 kg (with USB port: approx. 1.1 kg) Mounting Snaps onto DIN rail DIN EN 50022-35x15/7.5 1) All SITOP 24 V DC power supplies are permissible without restriction 2) Two battery modules connected in parallel are required in order to achieve 40 A 3) Permissible contact rating: 60 V DC / 1 A or 30 V AC / 1 A 4) "24 V DC o.k." means: Voltage of the power supply unit is greater than the battery connection threshold set on the DC UPS module 40

Page 11 of 11