Phospholipid Removal Plates

Similar documents
Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Oasis HLB Cartridges and 96-Well Plates

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

ProteinChip Energy Absorbing Molecules (EAM)

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

[ Care and Use Manual ]

A Complete Solution for Method Linearity in HPLC and UHPLC

Overview. Purpose. Methods. Results

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

How To Test For Contamination In Large Volume Water

Delivering a. New Era. of Technical. Support Services

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Chemical analysis service, Turner s Green Technology Group

Introduction. Methods. Sample Processing

Supplementary Materials and Methods (Metabolomics analysis)

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

A Novel Approach to Low Volume Sample Preparation

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Electrospray Ion Trap Mass Spectrometry. Introduction

WATERS QUANTITATIVE ANALYSIS solutions

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Updating the QIAcube operating software

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

PrepTip. Reverse Phase PrepTip User Guide

Gas Chromatography Liner Selection Guide

ApplicationNOTE Introduction

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

Purification of reaction mixtures using flash chromatography.

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

High-Throughput 3-D Chromatography Through Ion Exchange SPE

[ DISQUE DISPERSIVE SAMPLE PREPARATION EXTRACTION PRODUCTS ] QuEChERS. Simplifed

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Analytical Test Report

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Innovative vs Traditional

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

Diode, Schottky SMB/DO-214AA. Page <1> 24/04/08 V1.1. Dimensions Inches (Millimeters)

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Dissolved and precipitated oxalate

High Sensitivity MS Determination of Carryover in a New Autosampler Design

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

Sample Preparation for Forensic Toxicology and Clinical Research. Part 1: Sample Preparation Options

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

RapidFire for High Throughput Screening in early Drug Discovery

METHOD OF ANALYSIS. N methyl 2-pyrrolidone

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

QIAsymphony RGQ Protocol Sheet

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.

relating to household s disposable income. A Gini Coefficient of zero indicates

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

Thermo Scientific Mass Spectrometric Immunoassay (MSIA)

An In-Gel Digestion Protocol

ab vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.

Transcription:

Phospholipid Removal Plates Remove Phospholipids Remove Protein No Method Development

One Quick Method, Three Big Advantages 1 2 Remove Proteins from 96 samples at once Eliminate Phospholipids that cause ion suppression and increase your column lifetime! 3 No Method Development; one method for acids, bases, and neutrals Remove Proteins Solvent Shielding Technology prevents dripping of organic solvent, allowing for protein precipitation within the wells of the Phree Phospholipid Removal Plate. Eliminate Phospholipids The Phree sorbent selectively removes phospholipids from precipitated plasma samples. Proteins Phospholipids Target Analyte 212 Phenomenex, Inc. All rights reserved. 2

Be Free of Phospholipids and Proteins We have demonstrated that Phree Phospholipid Removal Plates resulted in >98 % decrease in the peak area of the six phospholipids we monitored in rat plasma compared to traditional protein crash. We highly recommend the use of these plates for high throughput LC-MS/MS bioanalytical sample preparation. Nina Khoshaba WIL Research 3 Steps Above Traditional Protein Precipitation...pp. 4-5 An Improved Phospholipid Removal Solution...pp. 6-7 Skip the Method Development...pp. 8-9 Technical Support...p. 1 Ordering Information...p. 11 3

3 Steps Above Traditional Protein Precipitation 1. Protein Precipitation Does Not Remove Phospholipids Endogenous phospholipids are a primary source of ion suppression and resulting matrix effects in bioanalytical LC/MS work. Ion suppression caused by the presence of phospholipids can result in: irreproducible results quantitation issues loss in method sensitivity matrix to matrix bias Total Phospholipid Profile Protein Precipitation vs. Phree Phospholipid Removal Plates 4.5e6 4.e6 3.5e6 3.e6 2.5e6 2.e6 Plasma Cleanup: 1 µl plasma plus 3 µl acetonitrile with 1 % formic acid Column: Kinetex 2.6 µm C18 1 Å Dimensions: 5 x 2.1 mm Part No.: B-4462-AN Mobile Phase: A:.1% Formic acid in Water B:.1% Formic acid in Methanol Gradient: Time (min).5 15.5 15.51 19.5 % B 95 95 Flow Rate: 4 µl/min Detection: Mass Spectrometer (MS) @ 425 C; 184 amu Temperature: 22 C 1.5e6 1.e6 5.e5 App ID 211 1 2 3 4 5 6 7 8 9 1 11 min ~ 5x Zoom 9.e4 8.5e4 8.e4 7.5e4 7.e4 6.5e4 6.e4 5.5e4 5.e4 4.5e4 4.e4 3.5e4 3.e4 2.5e4 2.e4 1.5e4 1.e4 5.. Selectively remove phospholipids with Phree Phree extracted plasma Protein precipitated plasma 1 2 3 4 5 6 7 8 9 1 11 min App ID 212 Phospholipid profile monitored using m/z 184-184 4

2. Reduce Ion Suppression The presence of phospholipids in plasma samples produces zones of ion suppression that correlate exactly with the phospholipid elution profile when analyzed via mass spectrometer (MS). Protein Precipitated Plasma Phree Extracted Plasma 1.2e6 1.e6 Ion suppression is observed 1.2e6 1.e6 8.e5 6.e5 8.e5 6.e5 Suppression zone is eliminated 4.e5 2.e5 App ID 213 4.e5 2.e5 App ID 213..2.6 1. 1.4 1.8 2.2 2.6 min.2.6 1. 1.4 1.8 2.2 2.6 min Suppression Zone Phospholipids m/z 184-184 Amoxapine was infused post-column to establish an ion suppression/enhancement profile with both protein precipitated plasma (left) and Phree extracted plasma (right), showing that Phree can successfully reduce ion suppression. Amoxapine m/z 314-271 3. Maximize Sensitivity and Column Lifetime Phospholipids reduce the sensitivity of the MS signal and shorten column lifetime when they build up over time. Column Sensitivity after 25 Injections 3 25 ~5, µl plasma injected without significant loss of sensitivity 2 Peak Area Counts 15 Reduced sensitivity is immediately observed Diclofenac in Phree Extracted Plasma Diclofenac in Protein Precipitated Plasma 1 Phospholipid build up results in significant loss of sensitivity 5 5 1 15 2 25 Injection Number (2 µl of Plasma) To assess the effect of phospholipid build up, repetitive 2 µl injections of diclofenac in protein precipitated plasma versus diclofenac in Phree extracted plasma were made. 5

An Improved Phospholipid Removal Solution Remove All Classes of Phospholipids Lysophosphatidylcholines and phosphatidylcholines both contribute to matrix effects. Remove all classes of phospholipids using Phree Phospholipid Removal Plates. 1.5e6 1.4e6 1.3e6 1.2e6 1.1e6 1.e6 9.e5 8.e5 7.e5 6.e5 5.e5 4.e5 3.e5 Phenomenex Phree Agilent Captiva NDLipids Supelco HybridSPE Plasma Cleanup: 1 µl plasma plus 3 µl acetonitrile with 1 % formic acid Column: Kinetex 2.6 µm C18 1 Å Dimensions: 5 x 2.1 mm Part No.: B-4462-AN Mobile Phase: A:.1% Formic acid in Water B:.1% Formic acid in Methanol Gradient: Time (min).5 15.5 15.51 19.5 % B 95 95 Flow Rate: 4 µl/min Detection: Mass Spectrometer (MS) @ 425 C; 184 amu Temperature: 22 C 2.e5 1.e5 1 2 3 4 5 6 7 8 9 1 min ~ 25x Zoom 4.8e4 4.4e4 4.e4 3.6e4 3.2e4 2.8e4 2.4e4 2.e4 1.6e4 Phree is most effective at removing all classes of phospholipids 1.2e4 8 4 1 2 3 4 5 6 7 8 9 1 min App ID 215 Phospholipid profile monitored using m/z 184-184 Agilent is a registered trademark of Agilent Technologies Inc. Captiva is a trademark of Agilent Technologies, Inc. Supelco and HybridSPE are registered trademarks of Sigma-Aldrich Co. Comparative separations may not be representative of all applications. 6

Extended Phospholipid Capacity The Phree sorbent has an extended capacity for phospholipids, allowing you to load up to 4 µl of plasma without significant breakthrough of phospholipids. 4.6e5 4.4e5 4.2e5 4.e5 3.8e5 3.6e5 3.4e5 3.2e5 3.e5 2.8e5 2.6e5 2.4e5 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 6.e4 4.e4 2.e4 2 1 2 3 4 5 6 7 8 9 1 11 min Phospholipid profile monitored using m/z 184-184 ~ 4x Zoom Plasma Cleanup: 4 µl plasma plus 1.2 ml acetonitrile with 1 % formic acid Column: Kinetex 2.6 µm C18 1 Å Dimensions: 5 x 2.1 mm Part No.: B-4462-AN Mobile Phase: A:.1% Formic acid in Water B:.1% Formic acid in Methanol Gradient: Time (min).5 15.5 15.51 19.5 Phenomenex Phree Waters Ostro % B 95 95 Flow Rate: 4 µl/min Detection: Mass Spectrometer (MS) @ 425 C; 184 amu Temperature: 22 C App ID 246 Waters Corporation states that the true maximum recommended plasma volume that can be processed using the Ostro plate is 35 µl due to well volume limitations. Ostro is a trademark of Waters Corporation. Comparative separations may not be representative of all applications. 7

Skip the Method Development One Method for Acids, Bases, and Neutrals ACN or MeOH 1 1. Dispense Organic solvent into the wells of the Phree Phospholipid Removal Plate in a volume of 3-4x the volume of the intended plasma sample. Maximum volume of organic solvent should not exceed 1.2 ml. Recommended organic solvents are listed below. 2 2. Add 25 µl 4 µl plasma directly into the organic solvent in each well of the Phree Phospholipid Removal Plate. Maintain a final ratio of 3:1 to 4:1 organic solvent:plasma. 4 3 3. Vortex* 2 minutes at maximum possible speed, taking care not to allow cross contamination. Sample can stand for up to 25 minutes. 4. Filter Centrifuge: Place the Phree Phospholipid Removal Plate on top of a collection plate and centrifuge at 5 g for 5 minutes or until filtrate is collected. Vacuum: Place the Phree Phospholipid Removal Plate onto a suitable 96-well sample manifold or robot. Ensure that a 96-well collection plate is positioned inside the manifold or under the Phree Phospholipid Removal Plate. Vacuum at 2-7 inch Hg for up to 5 minutes or until filtrate is collected. Positive Pressure: Place the Phree Phospholipid Removal Plate on top of a collection plate and apply 2-5 psi using a positive pressure manifold. * When used with a liquid-handling instrument or automation, aspirate/dispense cycles may be used to promote in-tip mixing and precipitation. This will ensure complete precipitation and filtration. Vortexing is not necessary when in-tip mixing is performed. Recommended Organic Solvents Solvent Solvent Volume Plasma Volume Acetonitrile with 1 % Formic acid 3 µl 1 µl Methanol with 1 % Formic acid 4 µl 1 µl Tip Phenomenex collection plates and sealing mats pair perfectly with Phree Phospholipied Removal Plates. Go to page 11 for a complete list of collection plates and sealing mats. 8

High Recoveries of Target Analytes The Phree general protocol has been developed to produce high recoveries of acids, bases, and neutrals while simultaneously removing all classes of phospholipids. Absolute Recoveries of Acids, Bases, and Neutrals 1% 9% 8% 7% Absolute Recovery (%) % 5% 4% 3% 2% 1% Diclofenac Naproxen Prednisone Acetaminophen Metoprolol Amitriptyline Acids Neutrals Bases % Analyte Recovery data was obtained by calculating the average absolute recoveries of analytes extracted from 3 Phree plates. 9

Sample Preparation Specialists are Ready to Assist You Two Levels of Method Development Support Level 1 Contact one of our dedicated sample preparation specialists for immediate method development assistance. Level 2 Send your sample to our analytical services group for custom method development. Visit www.phenomenex.com/phenologix for more information. Get Started Speak with your Sample Preparation Specialist: By phone: 31-212-555 or your local Phenomenex representative By email: Support@phenomenex.com Phenomenex s prompt support is very important for us to achieve our work. I thank them for their persistent support and innovative products. Allena Ji Wyeth 1

Order Phree Now! Part No. Description Unit Price 8E-S133-TGB Phree Phospholipid Removal 96-Well Plates 2/box Collection Plates (deep well, polypropylene) AH-7192 Strata 96-Well Collection Plate 35 µl/well 5/pk AH-7193 Strata 96-Well Collection Plate 1 ml/well 5/pk AH-7194 Strata 96-Well Collection Plate 2 ml/well 5/pk AH-8635 Strata 96-Well Collection Plate, 2 ml Square/Round-Conical 5/pk AH-8636 Strata 96-Well Collection Plate, 2 ml Round/Round, 8 mm 5/pk AH-7279 Strata 96-Well Collection Plate, 1 ml/well Round, 7 mm 5/pk Sealing Mats AH-8597 Sealing Mats, Pierceable, 96-Square Well, Silicone 5/pk AH-8598 Sealing Mats, Pre-Slit, 96-Square Well, Silicone 5/pk AH-8631 Sealing Mats, Pierceable, 96-Round Well 7 mm, Silicone 5/pk AH-8632 Sealing Mats, Pre-Slit, 96-Round Well 7 mm, Silicone 5/pk AH-8633 Sealing Mats, Pierceable, 96-Round Well 8 mm, Silicone 5/pk AH-8634 Sealing Mats, Pre-Slit, 96-Round Well 8 mm, Silicone 5/pk AH-7362 Sealing Tape Pad 1/pk Vacuum Manifold AH-895 Strata 96-Well Plate Manifold, Universal with Vacuum Gauge ea If Phree Phospholipid Removal Plates do not perform as well or better than your current phospholipid removal plate, return the product with your comparative data within 45 days for a full refund. Tip For more information about Phenomenex sample preparation products, visit www.phenomenex.com/sampleprepinfo Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www.phenomenex.com/termsandconditions. Trademarks Strata and Kinetex are registered trademarks of Phenomenex. Phree and Solvent Shielding Technology are trademarks of Phenomenex. Agilent is a registered trademark, and Captiva is a trademark of Agilent Technologies, Inc. Supelco and HybridSPE are registered trademarks of Sigma-Aldrich Co. Waters is a registered trademark, and Ostro is a trademark of Waters Corporation. Disclaimer Phenomenex is in no way affiliated with Agilent Technologies, Sigma Aldrich, or Waters Corporation. Comparative separations may not be representative of all applications. The opinions stated herein are solely those of the speaker and not necessarily those of any company or organization. 212 Phenomenex, Inc. All rights reserved. 11

Phospholipid Removal Plates Australia t: 2-9428-6444 f: 2-9428-6445 auinfo@phenomenex.com Austria t: 1-319-131 f: 1-319-13 anfrage@phenomenex.com Belgium t: +31 ()3-24187 f: +31 ()3-2383749 beinfo@phenomenex.com Canada t: (8) 543-3681 f: (31) 328-7768 info@phenomenex.com Denmark t: 4824 848 f: +45 481 6265 nordicinfo@phenomenex.com Finland t: 9 4789 63 f: +45 481 6265 nordicinfo@phenomenex.com France t: 1 3 9 21 1 f: 1 3 9 21 11 franceinfo@phenomenex.com Germany t: 21-5883- f: 21-5883-11 anfrage@phenomenex.com India t: 4-312 24 f: 4-312 2411 indiainfo@phenomenex.com Ireland t: 1 247 545 f: +44 1625-51796 eireinfo@phenomenex.com Italy t: 51 6327511 f: 51 6327555 italiainfo@phenomenex.com Luxembourg t: +31 ()3-24187 f: +31 ()3-2383749 nlinfo@phenomenex.com Mexico t: 1-8-844-5226 f: 1-31-328-7768 tecnicomx@phenomenex.com The Netherlands t: 3-24187 f: 3-2383749 nlinfo@phenomenex.com New Zealand t: 9-478951 f: 9-478952 nzinfo@phenomenex.com Norway t: 81 2 5 f: +45 481 6265 nordicinfo@phenomenex.com Puerto Rico t: (8) 541-HPLC f: (31) 328-7768 info@phenomenex.com Sweden t: 8 611 695 f: +45 481 6265 nordicinfo@phenomenex.com United Kingdom t: 1625-51367 f: 1625-51796 ukinfo@phenomenex.com All other countries: Corporate Office USA t: (31) 212-555 f: (31) 328-7768 info@phenomenex.com BR8859711_W www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com