illuminators installation guide (including IR Covert, IR PLATINUM, HYBRID and Low Voltage Series)

Similar documents
Floodlight Range Installation Guide

FIRERAY 2000 Installation Guide

5W LED Energy Saver PIR Bulkhead

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Charge Regulator SCR 12 Marine

Operating Instructions. UL325 Compliant Non-monitored

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

ST Series POWER SUPPLIES USER INSTRUCTIONS

MIC-WKT and MIC-WKT-IR

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

ARTICLE Night lessons - Lighting for network cameras

Bubble King. User Manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

Day / Night IR Color Camera User Manual V2.1.0

PART 1 PRODUCT (GENERAL)...1.

8146/5 Series Breaker Panelboards

13 Watt PORTABLE SOLAR POWER KIT

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

16/32 Channel 1U Rack Mount CCTV Power Supply

PART 1 PRODUCT (GENERAL)...1.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

USER S MANUAL HSC-24A

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Safety instructions VEGADIS DIS81.CEIA/V****

Dome Security Camera with IR night vision

LUCCI AIRFUSION QUEST II CEILING FAN

ACS-30-EU-EMDR-10-MOD

Rutland 913 Windcharger Fault Finding Guide

TIG INVERTER INSTRUCTION MANUAL

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

12-Volt 10-Amp Regulated Power Supply

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

Drayton Digistat +2RF/+3RF

RAY-MAX Integrated Solar Power Strip

4000 Series audio door entry system (using power supply) Installation Instructions IN9307.1

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Operating Instructions Bedienungsanleitung Mode d emploi

ADM1TE 5/30A DIN rail single phase two wire energy meter

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Global Water Instrumentation, Inc.

Triple Waveband Infra-Red Flame Detection

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

High definition day/night

HM-W536 Install Guide

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Battery Power Inverters

Portable Air Conditioner

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Cross-beam scanning system to detect slim objects. 100 mm in

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

2M IR Mini Dome Quick Installation Guide

V94 BULK TAPE DEGAUSSER

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Installation and Operation Guide for PD4100 Series Power Control Centers

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

MCR1900 Media Converter 19-Slot Chassis

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

INSTALLATION & SERVICE MANUAL. Display Panel

Mobile Data Power Model: MDP-25

LDG DTS-4/4R Desktop Coaxial Switch / Remote

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Contractors Guide Central Inverter System Installation

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

CO2 Alarm. Operation. Application

AUTODIALLER / QUICKDIALLER - SA132

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Operating Instructions. Room temperature controller

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

LED Security Spotlight User Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ELECTRONICS G H I J K L M

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Manual for Fire Suppression & Methane Detection System

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

TS510 & TS500. Installation & User Guide. Compatible Equipment

AutoRanging Digital MultiMeter

Video surveillance camera Installation Guide

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

12 Volt 30 Amp Digital Solar Charge Controller

Transcription:

MAX and LUX illuminators installation guide (including IR Covert, IR PLATINUM, HYBRID and Low Voltage Series) This installation guide provides instructions for installing the RAYMAX and RAYLUX series illuminators Installation Steps 1. Mount Illuminator 2. Mount Power Supply Unit (PSU) 3. Connect Illuminator to PSU 4. PSU connections 5. Connect PSU to Mains Set Up Steps 1. Position illuminator adjacent to camera and point towards scene 2. Adjust vertical angle 3. Adjust horizontal angle via Adaptive Illumination (AI) (if required) 4. Tighten all fixings Package Contents 1. Illuminator 2. Power Supply (PSU) Overview RAYMAX / RAYLUX illuminator Version 6.0 GOLDEN RULES: 1. Ensure PSU lid orientation has warning label in line with glands (see PSU diagram, right) 2. Ensure operating voltage is correct for unit being installed 3. DO NOT INPUT MAINS VOLTAGE INTO LOW VOLTAGE PSU 4. Ensure PSU is fully water tight! WARNING PSU 1

Adaptive illumination bolt LED illuminator Bracket LED output cable x2 2.5m (8.2ft) Photocell (automatic operation) LED output 1 LED output 2 Mains input! 1.5m Isolate mains before removing cover Mount PSU to flat surface Install in a well ventilated area Do not continually stare at lamp 2 Specifications subject to change without notice. Installation to be carried out by suitable trained and qualified personnel.

Installation 1m - 9m (3.3ft - 29.5ft) Model dependent Contact Raytec 3 2 Mains Lead 1 1 2 Mount illuminator Mount PSU: Do not position PSU photocell facing illuminator or other direct light sources Photocell monitors ambient lighting conditions Mount PSU on wall/flat surface with glands facing down! CAUTION: Red = +ve Black = -ve (polarity sensitive) 3 Connect Illuminator to PSU: Installers can extend or reduce lead length using appropriate cable and weather proof box! 4 LED Output x2 Mains In Telemetry Input PSU connections. Connect telemetry (if required) 5! Connect PSU to Mains CAUTION: Ensure cable glands and PSU lid are water tight by tightening the fixings 3

Set Up TARGET 1 Position illuminator adjacent to camera and point towards scene (Optional night set-up for optimum image performance) 2 Adjust vertical angle! Max x2 3 Adjust horizontal angle via Adaptive Illumination (AI) (if required) 4 Tighten all fixings! CAUTION: Do not fully loosen AI bolt. Note: Power adjust available if required (see PSU diagrams, pages 8-9) Match illumination to camera field of view Camera Camera x Light x Light Camera Light 4 Reduces performance May cause hot spots Best performance

Technical Drawings (Not to scale) Standard Bracketry 48mm (1.9 ) 23.5mm (0.9 ) 47mm (1.9 ) RM/RL 25 8.5mm (0.3 ) 25mm (1 ) 100mm (4 ) 115mm (4.5 ) 8.5mm (0.3 ) 36mm (1.4 ) 72mm (2.8 ) 52mm (2 ) 33mm (1.2 ) 8.5mm (0.3 ) 140mm (5.5 ) RM/RL 200/150/100/50 RM/RL 300 Optional Bracketry Wall Mount Ptz Mount Dome Mount Pole Mount 5

PSU Specifications INFRA-RED Series PSU RM300 RM200 RM150 RM100 RM50 RM25 Input universal<120w universal<80w universal<60w universal<40w universal<20w universal<10w Fuse 2.5A anti-surge 2.5A anti-surge 2.5A anti-surge 2.5A anti-surge 1A anti-surge 1A anti-surge Typical Output (Standard) 6.6A @ 13.5V 4.4A @ 13.5V 3.6A @ 13.5V 2.4A @ 13.5V 1A @ 13.5V 0.5A @ 13.5V Typical Output (IR PLATINUM) Typical Output (IR Covert) Adjustable Power 9A @ 14V 6A @ 14V 6A @ 14V 4A @ 14V 2A @ 14V 1A @ 14V 9A @ 14V 6A @ 14V 6A @ 14V 4A @ 14V 2A @ 14V 1A @ 14V 10% - 100% 10% - 100% 10% - 100% 10% - 100% 10% - 100% 10% - 100% Weight 2.3 kg (5.1lbs) 1.85 kg (4.1lbs) 2.3 kg (5.1lbs) 1.65 kg (3.6lbs) 0.9 kg (2lbs) 0.8 kg (1.8lbs) L x W x D Drilling 240 x 160 x 81mm (9.4 x 6.3 x 3.2 ) @ 225 x 123mm (8.9 x 4.8 ) 160 x 160 x 81mm (6.3 x 6.3 x 3.2 ) @ 145 x 123mm (5.7 x 4.8 ) 240 x 160 x 81mm (9.4 x 6.3 x 3.2 ) @ 225 x 123mm (8.9 x 4.8 ) 160 x 160 x 81mm (6.3 x 6.3 x 3.2 ) @ 145 x 123mm (5.7 x 4.8 ) 130 x 130 x 60mm 130 x 130 x 60mm (5.1 x 5.1 x 2.4 ) (5.1 x 5.1 x 2.4 ) @ 113 x 113mm (4.4 x 4.4 ) @ 113 x 113mm (4.4 x 4.4 ) WHITE-LIGHT Series PSU RL300 RL200 RL150 RL100 RL50 RL25 Input universal<120w universal < 80W universal<60w universal <40W universal <20W universal <10W Fuse 2.5A anti-surge 2.5A anti-surge 2.5A anti-surge 2.5A anti-surge 1A anti-surge 1A anti-surge Typical Output 6.3A @ 13.5V 4.2A @ 13.5V 4.2A @ 13.5V 2.8A @ 13.5V 1.4A @ 13.5V 0.7A @ 13.5V Adjustable Power 10% - 100% 10% - 100% 10% - 100% 10% - 100% 10% - 100% 10% - 100% Weight 2.3 kg (5.1lbs) 1.85 kg (4.1lbs) 2.3 kg (5.1lbs) 1.65 kg (3.6lbs) 0.9 kg (2lbs) 0.8 kg (1.8lbs) L x W x D Drilling 240 x 160 x 81mm (9.4 x 6.3 x 3.2 ) @ 225 x 123mm (8.9 x 4.8 ) 160 x 160 x 81mm (6.3 x 6.3 x 3.2 ) @ 145 x 123mm (5.7 x 4.8 ) 240 x 160 x 81mm (9.4 x 6.3 x 3.2 ) @ 225 x 123mm (8.9 x 4.8 ) 160 x 160 x 81mm (6.3 x 6.3 x 3.2 ) @ 145 x 123mm (5.7 x 4.8 ) 130 x 130 x 60mm 130 x 130 x 60mm (5.1 x 5.1 x 2.4 ) (5.1 x 5.1 x 2.4 ) @ 113 x 113mm (4.4 x 4.4 ) @ 113 x 113mm (4.4 x 4.4 ) HYBRID Series PSU Input Fuse Typical Output Adjustable Power Weight L x W x D Drilling universal<120w 2.5A anti-surge Model dependent Contact Raytec 10% - 100% 2.3 kg (5.1lbs) 240 x 160 x 81mm (9.4 x 6.3 x 3.2 ) @ 225 x 123mm (8.9 x 4.8 ) 6

Low Voltage PSU (LVP) Specification INFRA-RED AND WHITE-LIGHT Series PSU (Excluding Platinum and Covert Series) 300 200 150 100 50 25 Input x 24V AC/DC x 24V AC/DC 12/24V AC/DC 12/24V AC/DC Fuse x 5A x 5A 3A 3A Typical Output (Infra-Red) Typical Output (White-Light) Adjustable Power x 4.4A @ 13.5V x 2.4A @ 13.5V 1A @ 13.5V 0.5A @ 13.5V x 4.2A @ 13.5V x 2.8A @ 13.5V 1.4A @ 13.5V 0.7A @ 13.5V x 10% - 100% x 10% - 100% 10% - 100% 10% - 100% Weight x 1.85 kg (4.1lbs) x 1.65 kg (3.6lbs) 0.9 kg (2lbs) 0.8 kg (1.8lbs) L x W x D x 160 x 160 x 81mm (6.3 x 6.3 x 3.2 ) x 160 x 160 x 81mm (6.3 x 6.3 x 3.2 ) 130 x 130 x 60mm 130 x 130 x 60mm (5.1 x 5.1 x 2.4 ) (5.1 x 5.1 x 2.4 ) Drilling x @ 145 x 123mm (5.7 x 4.8 ) x @ 145 x 123mm (5.7 x 4.8 ) @ 113 x 113mm (4.4 x 4.4 ) @ 113 x 113mm (4.4 x 4.4 )! NOTE: Ensure operating voltage is correct for unit being installed. DO NOT INPUT MAINS VOLTAGE INTO LOW VOLTAGE PSUs. Power Supply Features Maximum Projected Area (M²) STANDARD PSU Adjustable photocell PULSED PSU - PU Analogue version RM/RL25 (Single panel) 0.0086 Adjustable power TTL version Telemetry input No photocell Adjustable power RM/RL50 (Single panel) 0.0155 12V DC output @ 1.5A Synchronised with camera RM/RL50 Adaptive Illumination (Double panel) 0.0173 RM/RL100 (Single Panel) 0.0279 PREMIUM PSU-PR Adjustable photocell Adjustable power Telemetry input Photocell following contact, volt free relay contact - normally open (day) to normally closed (night) 12V DC output @ 1.5A PREMIUM TIMER PSU-PRT Adjustable photocell Adjustable power Telemetry input Photocell following contact, volt free relay contact - normally open (day) to normally closed (night) 12V DC output @ 1.5A Timer function RM/RL100 Adaptive Illumination (Double Panel) RM/RL150 Adaptive Illumination (Triple Panel) RM/RL200 Adaptive Illumination (Double Panel) RM/RL300 Adaptive Illumination (Triple Panel) 0.0311 0.0466 0.0559 0.0838 7

Power Supply Diagrams (Not to scale) INFRA-RED and WHITE-LIGHT RM/RL 50/25 Models (Not to scale) Photocell Power Adjust Telemetry Input - requires zero volt, latched input Photocell Sensitivity LED Output x2 (Polarity Sensitive) Mains Input 100V to 230V AC Auto-Sensing INFRA-RED and WHITE-LIGHT RM/RL 200/100 Models (Model shown: RM/RL 100 Premium) (Not to scale) 12V DC power output (Premium PSU only) Photocell following contact - volt free, non polarity sensitive (Premium PSU only) Telemetry Input - requires zero volt, latched input Photocell Power Adjust Photocell Sensitivity LED Output x2 (Polarity Sensitive) Mains Input 100V to 230V AC Auto-Sensing 8

INFRA-RED and WHITE-LIGHT RM/RL 300/150 and Hybrid Models (Final specification model dependant - model shown: RM/RL 300 Premium) Note - Hybrid control boards will be labelled IR/WL Photocell following contact - volt free, non polarity sensitive (Premium PSU only) Telemetry Input requires zero volt, latched input Photocell Sensitivity Photocell 12V DC Power Output (Premium PSU only) Power Adjust Up to x3 LED Output (Polarity Sensitive) (Model Dependant) Mains Input (100V to 230V AC) Auto-Sensing Hybrid PSU Models Factory Setting: IR controlled by photocell WL controlled by telemetry night time only Attach 1 wire of volt free input into photocell following output on top control board and other wire of volt free input into telemetry input on bottom board. Other set up options available...contact Raytec. 9

Trouble Shooting Ensure all tests are undertaken by a qualified, trained engineer Ensure safe working practices are followed at all times PLEASE NOTE: If the external flexible cable or cord is damaged, it shall be exclusively replaced by manufacturer, service agent or similarly qualified person to avoid a hazard. Step 1: Basics Check polarity of Lamp connection red=+ve, black=-ve Check telemetry link is in Check photocell is working Check power setting pot fully clockwise Check mains input Check fuse intact If OK Step 2: Lamp Test Check voltage of lamp o/p approx 14V (8V for pulsed units) Check current of lamp see instructions for correct current setting To check lamp current (this must be done while both LED panels are connected to the PSU) remove +ve LED from both lamp supply cables and connect multimeter set to 10A current in line with the lamp. [One lead of multimeter in common (COM), other lead into 10A socket of multimeter; set multimeter to 10A readings]. Refer to PSU Specifications for correct current settings, see pages 6-7. Step 3: Set-up Camera, lens and illumination Check alignment of lamp Check camera lens fully open at night & set correctly Check model number to Raytec performance specification to ensure required distance is achievable 10

Step 4: Call Raytec for further assistance Note down: Model and serial number of illuminator Camera make and model Lens make and model If the Raytec lamp is still not delivering the required performance, please contact us for further assistance. Additional Information UL 1838 & CSA 22.2 No 9.0 96 Classification Suitable for indoor and outdoor use Suitable for use in wet locations Suitable for mounting on flammable surfaces Suitable for combustible surface use Suitable for temperatures not exceeding 35 C Do not connect PSU to an ungrounded supply Do not install within 10ft of pool or spa Do not use with dimmers Do not connect two or more power supplies in parallel This product must be installed by a person familiar with the construction and operation of the product and the hazards involved, in accordance with the applicable installation code. The device is accepted as a component of a landscape lighting system where the suitability of the combination shall be determined by CSA or local inspection authorities having jurisdiction. Such systems should be protected by a ground fault circuit interrupter of the Class A type. Raytec Warranty Please register you Raytec LED Illuminator(s) for its 5 year warranty by visiting www.rayteccctv.com/products/warranty-card 11

UK / Europe T: +44 (0) 1670 520055 F: +44 (0) 1670 819760 sales@rayteccctv.com 12 RRII/13/2.1 Americas (Toll Free) T: +1 888 505 8335 ussales@rayteccctv.com www.rayteccctv.com