PRODUCT OVERVIEW & CUSTOM PRODUCTS



Similar documents
EMR Corp N. 19th Avenue Phoenix, Arizona Toll Free: Tel: (623) Fax: (623)

Bi-Directional Amplifier Systems

USER MANUAL. Kramer Electronics, Ltd. Models:

PS 155 WIRELESS INTERCOM USER MANUAL

Receiver Multicoupler & R.F. Preselectors

MASTR III RF Package, VHF

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

DSA800 Series Spectrum Analyzer

Alarm Clock USER GUIDE

LDG DTS-4/4R Desktop Coaxial Switch / Remote

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

PagePac PAGEPAL V

User Manual PT-E-HIP

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

USER MANUAL. Kramer Electronics, Ltd. Models:

Why is Passive Intermodulation Important?

FREQUENCY RESPONSE ANALYZERS

M2M Cellular Signal Amplifier

Load Cell Amplifier Module. Instruction Manual LCA

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

F2400 FOM II Series Fiber Optic Modem Technical Manual

How To Tune A Duplexer

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

Powerware Relay-Serial Card User s Guide

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

DVB-T Television Repeater Jim Andrews, KH6HTV

ELEMENTS OF CABLE TELEVISION

Weather Radio Alarm Clock

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

Guide. Installation. Signal Booster. Wilson. In-Building Wireless Smart Technology Signal Booster. Contents:

PRECISION MICRODYNAMICS QUOTE / CONTRACT TERMS & CONDITIONS

MTR3000 BASE STATION / REPEATER & SATELLITE RECEIVER

FB-500A User s Manual

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

This product has the equivalent gain performance with the 14 element Yagi antenna.

TUNABLE ANTENNAFIER LT/DT SERIES INSTALLATION INSTRUCTIONS

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

Unidirectional Transmitter/ Receiver Units Introduction

Performance Specifications

HI-FI FM TRANSMITTER. MS-100 series INSTRUCTION MANUAL

AMC GENERIC WARRANTY POLICY GUIDE

Wireless Base Station Single and Multiple Headsets

"FP", "FR", "FQ" Series Bandpass Filters

MOTOTRBO PROFESSIONAL DIGITAL TWO-WAY RADIO REPEATERS

USER MANUAL DUET EXECUTIVE USB DESKTOP SPEAKERPHONE

PC Tab Security System INSTRUCTION MANUAL

ANT1750F Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle

ClearGain Tower Mounted Amplifiers A Deployment Guide for Wireless Carriers

Owner s Manual channel amplifier

MS900AC-B-LS User Information

Agilent 8753ET/8753ES Network Analyzers

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

ALARM CLOCK RADIO FOR ipod/iphone

GPS 35 USB. installation and quick start guide

Compact SDI Routers KUMO 1604 KUMO 1616 KUMO CP

Experiment 7: Familiarization with the Network Analyzer

Guide. Installation. Wilson Electronics, Inc. Adjustable Gain Signal Boosters

Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ

Bid Specifications. FDMA / FSK Digital Radio Communications System. Bid must include the following:

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

TS-300-MSF TS-300 INSTALLATION AND CONFIGURATION MANUAL

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

AVerMedia AVerKey imicro User s Manual

Advantium 2 Plus Alarm

Mobile 3G. Cellular Signal Booster Need help? Tech Support Mon.- Fri. Hours: 7 am to 6 pm MST

Product Specification instalert Rapid Messenger Variable Message Sign

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

The main purpose of the study was to answer the three following questions:

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Contents. 2 NP560-NP562 Installation Guide YML821 Rev1

BroadBand PowerShield. User Manual

General Terms and Conditions for Online Sales of TomTom Inc ( TomTom )

Wilson. Adjustable Gain Signal Boosters AG Pro 75, AG Pro 70, AG Pro Installer, AG SOHO 65, AG SOHO 60

NETWORK TECHNOLOGY. Long Range Radio Networks

MAINTENANCE & ADJUSTMENT

Triton Systems of Delaware, LLC Warranty Statement / Return Policy

Interfacing the Yaesu DR 1X

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

INSTRUCTION MANUAL MODEL PCD-88

2. OVERVIEW OF COMMUNICATION SYSTEMS

Limited Warranty for PV Modules

All Hazards Weather Alert Radio WR-100

Single Port T1/E1 Tap

MOTOTRBO DIGITAL TWO-WAY RADIO REPEATERS

ACRS 2.0 User Manual 1

USB 3.0* Radio Frequency Interference Impact on 2.4 GHz Wireless Devices

User Manual TuneCast Auto for ipod

Transponder for GainMaker Amplifiers

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Hutton Communications, Inc GSA Pricelist

VK-250 WARRANTY REGISTRATION FORM

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

VJ 6040 Mobile Digital TV UHF Antenna Evaluation Board

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

VDSL Ethernet LAN Extender

Transcription:

Bill Lieske, Sr. was involved in radio communications for more than 60 years. At the age of 13 Bill, Sr. started what evolved into a lifelong passion by obtaining his amateur radio license. In WWII Bill, Sr. was chosen by the US Army to be involved in the burgeoning new technology of the time, radar. Upon being honorably discharged after WWII Bill s passion for all things radio led him into stints with public safety agencies, Motorola, RJ Communications and Sinclair, all leading, eventually, to his decision to venture on his own and EMR Corporation was founded in 1980. As the founder and chief engineer of EMR Corporation, Bill s approach to RF systems and component designs was without parallel in the industry. Bill Sr. s work helped set industry standards in the U.S. and international land mobile communications and antenna site management industries. His practical approach to ferrite and hybrid device design positioned EMR as an OEM supplier to both the Land Mobile Radio (LMR) as well as the TV and FM broadcast industries. Cavity resonant, filters, duplexers, combiners and multicouplers are natural companion products to ferrite and hybrid devices. So, it wasn t long before EMR began offering these additional products to not only OEM s but to RF Distributors and Dealers. Now under Bill Lieske, Jr. s guidance, EMR continues to thrive operating under the same business and manufacturing principals that were instilled by Bill, Sr. Today, EMR offers a complete line of antenna site and mobile filtering products covering the R.F. spectrum from 30 MHz to 2.8 GHz, and products capable of handling power levels up to 2 KW. Our line is extensive, we have many products to provide effective communications in today s challenging R.F. environments. Founder William (Bill) Lieske, Sr. (1923-2008) With EMR s specialized team member s, top-notch engineering, and state of the art manufacturing we can design and manufacture a wide variety of custom products as well as standard products. EMR excels in unique designs and welcomes all design inquiries. From our founding, our corporate philosophy has been, is, and will be to provide the highest quality products, at the greatest level of technical excellence, with the most practical consideration, at an economical price. President Bill Lieske, Jr. General Manager Steve Broscious VP Engineer Douglas Ferrini Production Manager Rod Defoor

PRODUCT OVERVIEW & CUSTOM PRODUCTS EMR standard product offering is comprised of a mature line of high quality, highly reliable: isolators, filters (1/4 wave, helical, combline, hogout, aperture coupled), receive LNA s (single stage, two stage or quadrature E-pHEMT), multicouplers, tower top multicouplers (amplifier bypass, b/u with auto switching), combiners (hybrid ferrite, filter ferrite, active and passive short haul/control station, repeater system), duplexers (1/4 wave, helical, mobile 50 and 100 watt versions), bidirectional and unidirectional systems (upgrades include higher gain, UPS w/battery backup, monitor/alarm both local and remote), site monitoring and many other component level devices necessary to provide effective communications in today s challenging RF environments. Custom products are one of our specialties, contact us with your unique requirements and we will design a custom product for you.

IN-BUILDING SYSTEMS & ACCESSORIES BENEFITS & FEATURES OF EMR ENHANCEMENT SYSTEMS: Designed specifically to meet your enhancement needs. Amplifiers are unique to enhancement signal characteristics and F.C.C. type accepted. System gain set provisions and signal overload protection assures optimum performance. Filtering is custom designed and tuned to meet individual system requirements. NFPA and/or IFC Compliant Optional 24/7 System Monitoring Ultra reliable - Field tested designs utilizing the highest quality components. Five year warranty System design assistance provided. We will ask you to provide details of the structure(s) to be enhanced. Certain measurements and tests must often be made in order that signal distribution may be determined. This work can be accomplished by your technical staff or EMR Corp. In-Building Coverage Bi-Directional & Uni-Directional Systems

TRANSMITTER COMBINERS - CAVITY FERRITE & HYBRID LOW LOSS TRANSMITTER COMBINERS 66-960 MHz Standard transmitter combiner input connectors are N Type. Other connector types are available by request. If combined output power exceeds 400 W, 7/16 DIN connectors are recommended. Large cavities are available for tighter channel spacing and higher transmit power. Hybrid Combiners are available from 2 to 16 channels Hybrid Combiners with more than 2 channels include all internal cabling

RX MULTICOUPLERS Multicouplers are supplied complete, pretuned and ready for installation. Standard components include preselector, adjustable gain amplifier, receiver signal power divider(s). Multicouplers with up to 8 ports, are mounted on a 5.25 x 19 x 10 relay rack panel and chassis. Standard antenna input connectors are Type N Female. Our compact design 1 RU Receiver Multicoupler is ideal for limited space settings. Contact our factory for additional details on this product. Standard Tower Top Multicoupler Components: Preselector Adjustable gain amplifier DC pick off with lightening protection Weather resistant aluminum NEMA enclosure N Female input/output connectors 2 saddle mast mounting brackets

ANTENNA DUPLEXERS Economical Base Station Duplexers & Specialized Duplexers Full Line of Base Station Bandpass & Pass Reject Duplexers Mobile Duplexers

COMPACT INTEGRATED COMBINING SYSTEMS SYS SERIES PRODUCT FEATURES: Available for up to 100 w Power Applications: VHF, UHF, 700, 800 & 900 MHz. Up to 8 Channels Suited for On-site and local area: Industrial Applications for local area coverage. Compact size: Only 3 RU height (5.25 vertical Height for 25 W, 2, 3 and 4 CH version). Full duplex: Ideal for New digital RF Repeater Systems including idas, MOTOTRBO and NXDN HOMELAND SECURITY RF COMBINING SOLUTIONS SFR1 SERIES PRODUCT FEATURES: Frequency Bands: 154-174 (20 MHz BW) 350-650 (20 MHz BW) 650-960 (63 MHz BW) Practical Compact Design Up to 8 Channels TX Insertion Loss: 8 to 16 db Input Power: 50 Watts RX to RX Isolation: 60+ db Connectors: Type N Female

POWER MONITORING + POWER SENSOR ipm1 Product Features: PTT (Push-to-Talk) Test PTT Sense COR (Carrier-on-Receiver) Sense System Log - View reading via web browser Alarm e-mail notifications Real time clock with NIST Sync Forward & reverse power graphs VSWR graphs Contact closure & LED alarm Rack mounting for multiple devices POWER SENSOR: Model: 2491/T-2(ADCRMS) 134-174 MHz Model: 2591/T-2(ADCRMS) 380-512 MHz Model: 2691/T-2(ADCRMS) 650-960 MHz Power Input: 1000 W (Max. Continuous) Operating BW: 50 MHz (Min.) Return Loss (io Port): 20 db (Min.) Insertion Loss: 0.15 db (Max.) Directivity: 25 db (Min.) Connectors: N-Female, RJ11 Impedance: 50 ohm Overall Dimensions: 1.5 x 1.3 x 4.2

CAVITY RESONATORS & ACCESSORIES High Power Cavity Resonators up to 3 KW Hybrid Couplers Harmonic Filters RX Amplifiers Impedance Matchers Load Terminations Power Attenuators Directional Couplers Bandpass & Pass Reject Cavities from 66 MHz to 2.0 GHz

COMPLETE LINE OF FERRITE DEVICES FROM 66 MHz - 2.8 GHz Low Power Isolators for Data Trunking & Broadcast Applications Medium Power Isolators for LMR, Cellular & Trunking Applications High Power Isolators for special product design specific to Broadcast, Aeronautical & Maritime applications. High Power Isolators & Intermodulation Panels for Paging Applications.

Five Year Warranty Satisfaction Guaranteed System Engineering Technical Excellence In-House Machine Shop Practical Designs Competitively Priced Top Quality Products Best Technical Support in the Industry Flexibility to Customer Requirements Exceptional Customer Service

WE VE MOVED! Our expansive 24,000 sq. ft. building houses EMR s core manufacturing, engineering, test lab, executive, sales/marketing and administrative departments.

ORDERING, TERMS & POLICIES ORDER PLACEMENT: All prices shown are list price, FOB factory (Phoenix Arizona - USA) and are subject to change without prior notice. Prices include domestic packaging and are exclusive of federal, state or local excise or sales taxes, duty or brokerage charges on export shipments. Unless otherwise negotiated freight will be prepaid and added to the invoice. OPERATING FREQUENCIES: Operating frequencies and power levels used in preparing EMR products are those provided by the customer. Errors in operating frequencies or power levels made by EMR will be corrected at no charge. Errors due to faulty information from the customer are subject to all shipping charges and any material and/or labor cost incurred by EMR Corporation to correct the order. TERMS OF SALE: Terms of sales are C.O.D., or Cash with Order unless other terms have been established prior to shipment. Open account status will be extended upon reasonable assurance of credit worthiness. Past due accounts are subject to a late charge of up to 2.0% monthly, beginning 30 days after the date of issuance of our valid invoices. ORDER ACCEPTANCE: An order is considered contractually valid when a purchase order is accepted by mail, telephone, facsimile or e-mail. Cancellations made less than 15 days prior to scheduled ship date may be subject to a cancellation charge. CLAIMS FOR SHIPPING LOSS OR DAMAGE: All shipments will be made via the customers specified mode of transportation. If coded best way the shipment will be consigned to the most economical, reliable commercial carrier. Insurance will be taken unless the customer specifically takes responsibility for shipping loss or damage. Although claims for loss are the responsibility of the consignee, EMR will assist in all ways in making claims and tracking for loss or damage to any of its shipment. MODIFICATION AND DELAYS: EMR reserves the right to make design changes or modifications to any of its products without specific prior notification provided that such modifications do not materially reduce the value or performance of the equipment concerned. EMR will not be responsible for delays in shipment occasioned by slow or interrupted deliveries to EMR of components, materials or processes necessary to the completion of any project as originally scheduled. PRODUCT RETURNS: Merchandise returned without having first obtained written acknowledgment from EMR may be rejected. Unless otherwise authorized, credit or refund will not exceeds 90% of originally invoiced amounts, and in no event shall include transportation costs. Return authorizations shall expire in 60 days unless otherwise specifically noted. MECHANICAL SEALS: EMR provides mechanical seals on many of its products. These seals insure that the unit has not been modified or tampered with once it has left the factory. Breaking these seals without consent from an authorized EMR Corporation engineer or technician may void the warranty policy stated below. STANDARD WARRANTY POLICY: EMR Corporation, hereinafter called EMR, warrants that all equipment of its manufacture shall be free from defects in design, material and workmanship for a period of 5 years from date of shipment unless otherwise covered by special warranty. If any such product, entirely or in part, fails to produce the performance as set forth in the brochure, quotations or literature provided by EMR, such product will be replaced or repaired at EMR s expense provided that the failure was not the result of alteration, misuse, tampering, misapplication, shipping damage or vandalism. If a product failure is found to be the fault of EMR the cost of transportation to the EMR factory and its return will be born by EMR. A reasonable charge for travel and subsistence costs will be invoiced when on-site repairs are necessary. Should EMR supply components not of its own manufacture, but specified by a customer, the warranty shall reflect the original manufacturers warranty, only. It is understood that this statement constitutes EMR s entire and only warranty, there being no other warranties expressed or implied in law or in fact, including implied warranties of fitness. In no event shall EMR be liable for damages, either direct or consequential, that may be occasioned by any defect in material, workmanship or product support. DESTINATION CONTROL STATEMENT: EMR Corporation strictly adheres to all laws and regulations of the United States Government regarding the export or re-export of our products outside the United States of America. EMR Corporation requires notification regarding the intention to export any products outside the United States of America. Information for the export or re-export requires country of ULTIMATE destination, purchasing individual(s), corporations, financial institution(s), shipping documentation, and shipping entities. This information must be disclosed and on file at EMR Corporation prior to any shipments in accordance with the Export Administration Regulations. Any action contrary to U.S. laws is strictly prohibited.