DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.



Similar documents
Smile. The All-In-One Heating Controller

Heating Controller. Building Technologies HVAC Products

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Installation & User Instructions

RRV934. Multi-controller. Synco living

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

Aerona Air Source Heat Pumps

User Manual THR840DUK Digital Thermostat

User's Instructions. Alpha HE CB25/33 and HE SY25

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Drayton Digistat +2RF/+3RF

HCE80/HCC80/HCE80R/HCC80R

Electronic Control Devices The European Product Catalogue 2007

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

T5000 T000 LCD Digital Fan Coil Thermostat

Electronic Control Devices The European Product Catalogue 2007

Controls for fan coil units and cassettes

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

OZW30. Central Unit SYNERGYR

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Controller Automation, Model II+

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Inwall Room Temperature Unit

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

Satchwell CSC COMPENSATORS FEATURES

Heating and Hot Water Services Controls General Technical Specification

Duct Humidity Transmitter

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

T7560A,B,C Digital Wall Module

Y-200 Multi-Stage Sequencer

CO2 Alarm. Operation. Application

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

HERZ-Thermal Actuators

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Master & Amplifier For ModuSat Communal Heating

RY2 miniature industrial relays

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

ES-LCD User Control SD Card Location

SMART SENSOR COLLECTION

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ABB i-bus KNX Fan Coil Controller FC/S 1.1

PD 100A. Printing data system

TMS TANK MANAGEMENT SYSTEM

Easy drop down menu allows quick set up, the clear large display offers a choice of menus and the interface echo can be constantly seen if needed.

FIREDEX Conventional Fire Panels

Thermostats. comfort at your command

ELECTRIC CENTRAL HEATING FLOW BOILER

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

RAINCONTROL LCD Special

Adjustable room thermostat for heating only or cooling only systems

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

STERILIZERS, LABORATORY DRYING OVENS

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Homeowner Quick Start Guide. Version 2

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Flush-mounted room thermostats

Digital timer thermosatat. isense. Installation and Service Manual AG

FX07 Field Controller

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Daikin Altherma Hybrid Heat Pump

Wireless 7 Day Programmable Room Thermostat

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

KONRAD. Hybrid Fancoil Series

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Electric Flow Boiler

CONTROL STRATEGIES FOR HVAC SYSTEMS

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Temperature & Humidity SMS Alert Controller

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

38 Series - Relay interface modules A

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Transcription:

1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings.

02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring optimiser/ compensators, capable of controlling one or two boilers in sequence with HWS time control. Designed for easy installation and operation in small/medium commercial properties, they are a costeffective option for achieving significant improvements in energy use. Product A A GLANCE Easy set-up - these controllers are selfconfiguring, matching the connected sensors Easy to use - simple, intuitive user interface Flexible application - caters for a wide variety of control schemes Energy efficiency - optimiser function delivers consistent energy savings rouble-free operation - proven reliability minimises problems and ensures peace of mind Self-Configuration he 1100 and 1400 are self-configuring. he controller recognises the application by the sensors that are connected to it, and configures itself accordingly. he use of sensible default settings, and self-adaptive optimiser and compensator routines, means that the system can be set to work quickly after the required temperatures and times have been entered. he controller will automatically fine tune, matching the building s requirements. o further reduce installation costs, a single outside sensor can pass information to other 1100/1400 s on the same site. Ease of Operation he user interface is designed to make day-to-day operation of the controllers as easy as possible. he large LCD display shows current status at a glance. he front panel control switch provides easy selection options, including an override to allow the heating to be turned on and off without the need to change the settings at the controller. his can also be achieved by means of a remote switch unit. Schneider Electric One High Street, North Andover, MA 01845 USA elephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings SDS-1100_1400-A4.BU.N.EN.9.2008.0.00.CC

03 1100 & 1400 Energy Controllers Features (continued) Enhanced Boiler Performance Boiler control in sequence with optional automatic weekly rotation provides stable control conditions, eliminating short cycling during light load conditions and enhancing boiler performance and life. Product Selection AC offers a complete range of field devices to match the operating requirements of the 1100 and 1400. Our regional sales office will advise you in choosing the right models for new projects and for upgrading CMC and CSMC installations. Bright LEDs indicate which functions are on, clearly showing the controller s output status. An alarm is included to display a number of operating faults. he large four-line display normally shows the time, date, a selected temperature and the current operating status. It is also used to view alarms and change settings. An intuitive, menu driven, LCD display makes setting and commissioning easy. he control switch selects a choice of settings: normal automatic control of heating and hot water; summer operation of hot water only; constant heating; frost protection only; a set position to change times and temperatures. A service mode allows for plant maintenance without alteration of controller settings. Schneider Electric One High Street, North Andover, MA 01845 USA elephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings SDS-1100_1400-A4.BU.N.EN.9.2008.0.00.CC

04 1100 & 1400 Energy Controllers Applications DO DW DO DR DR DO DO DW DW he 1100 and 1400 provide total heating control, controlling both the heat source and the heat emitters, whether conventional radiators, under-floor coils, fan convectors or other devices. Many different applications DR are possible. DO DO DO DW DO DR DR F DR DW DO DO Applications DR DR DO F DW DO DW F DW DR Optimisation Only DO DW Optimisation with Boiler Compensation one or two boiler control DO DR Valve Compensation only fixed F time start boiler sequence control DW DR DW DO DO DW DO DO DO DO DR DO DO DR DR F DW DR DW DO DO DO DR DR DW DW DW DW DW F DW DW DO DW F DW DR Optimisation and Boiler DW Sequence Control F DW DW DW DR DO DO DO DR DW DR DO DO DR F DR DO DR DO DO Optimisation with DW DW DO DO Valve Compensation DR DR F DR DW DW DO DO DO F DR F DR DW DW DW DW F DR DO DO Optimisation and Valve/boiler DW DW Compensation one or two boiler control DW DW DW DO DR DR DO Step Controller No.3 No.4 DO DW DR DR DR DO F F F DR DO DR DO DO F DR DO DO DW F DW DW DW Boiler F Compensation F fixed time start DW DW one or two boiler control DO DO DO DO DW DW DW DW DO DO DR DR F DW DW DR DW DW DO DO DO F DR Valve Compensation F DR only fixed time start DW DW DW DW DW DW DW F F DR DR Optimisation with Valve Compensation and Step Controller boiler sequence control DW DO DW F F DW DW DW F F DO DO DW DO DO DO F F DR DO DR DO DO DW DW Step Controller DW DO DO F F DW DW DW DW DR No.3 No.4 DO DO F DR DR F No.3 No.4 DW DW F F DO DO DR DW DW DR DR DW DW DW DW DW DW DW DW F F F F DR DO DR DO DO DO DO DW DW DO DW DW DO DO DW DW DW DW DO DO F F Step Controller Step Controller DW DW DO DO DR No.3 No.4 DR No.3 No.4 Step Controller Step Controller DW DW DW DW F F DW DW DR DR No.4 No.3 No.3 No.4 DR DO DO DR DO DO DW DW Step Step Controller DW DW DR No.3 No.4 DR No.3 No.4 Schneider Electric One High Street, North Andover, MA 01845 USA elephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings SDS-1100_1400-A4.BU.N.EN.9.2008.0.00.CC

05 1100 & 1400 Energy Controllers Functions Functions Self configuring controller Self adaptive optimum start Self adaptive optimum stop Day economy switch off Boiler sequence control Weekly boiler rotation Valve compensation Boiler compensation Valve/boiler compensation Self-adaptive compensator option Adjustable space temperature reset on compensator Night set back (space or flow temperature) Variable pump overrun Hot water time channel Multi-stage frost protection Valve/pump summer exercise Holiday scheduling BS/GM auto clock change Summer/winter operation Front panel selector AUO / SUMMER / CON / FROS / SERVICE Remote override facility Alarm indicator Optimum Start Space temperature Ordinary timer start Optimiser start latest possible he controller starts and stops the plant at the earliest or latest possible time to reduce energy consumption. Weather Compensated Control Max Flow temp. Min Saving 1700 0900 hours Self adaption Outside temperature Max he flow temperature is adjusted to the outside to match heat losses from the building, preventing overheating and maintaining comfort. Schneider Electric One High Street, North Andover, MA 01845 USA elephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings SDS-1100_1400-A4.BU.N.EN.9.2008.0.00.CC

06 1100 & 1400 Energy Controllers Specifications 1100 & 1400 ypes 1100 Energy Controller using A series sensors 1400 Energy Controller using standard Satchwell sensors Electrical/Mechanical Power supply 230 Vac, 15 VA (50/60 Hz) Relay ratings SPNO 230 Vac, 3 A resistive, 1 A inductive Operating conditions 0 to 50 C, 5 to 95% rh non-condensing Construction Case Moulded polycarbonate plastic case, Fire resistant to UL94-V-0 Dimensions Controller 191 x 144 x 106 mm Protection class IP40 Complies with EC directives EMC, LVD Mounting Panel or surface mount Easy Installation he separate wiring base unit allows easy wall or panel mounting and access to the terminals. A single screw secures the controller to the base. Gold plated pins ensure good contact between controller and wiring base. All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. Schneider Electric One High Street, North Andover, MA 01845 USA elephone: +1 978 975 9600 Fax: +1 978 975 9698 www.schneider-electric.com/buildings 2008-2009 Schneider Electric. All rights reserved. SDS-1100_1400-A4.BU.N.EN.9.2008.0.00.CC September 2008 pdw