Bonding Agent Underneath Sealant: Shear Bond Strength to Oil-Contaminated Enamel



Similar documents
Adhesive Solutions. Scotchbond Universal Adhesive. SEM pictures of Scotchbond Universal Adhesive. One bottle for all cases! Total-Etch and Self-Etch

Our Mission: Protecting partially. erupted teeth. With Fuji TriageTM from GC. One of many GC solutions for caring for youngsters.

Shear bond strength of metallic brackets bonded with a new orthodontic composite

Clinical randomized controlled study of Class II restorations of a highly filled nanohybrid resin composite (4U)

Effect of salivary contamination at different steps of the bonding process on the microleakage around Class V restorations

Influence of Diet and Oral Hygiene Practices on Retention of Fissure Sealant in Rural and Urban Children An in vivo Study

1- Fatigue-Resistance and Microleakage of CAD/CAM Ceramic and Composite Molar crowns

In vivo evaluation of different techniques for establishment of proximal contacts in posterior resin composite restorations

CLASSIFICATION OF CARIOUS LESIONS AND TOOTH PREPARATION.

Eliminating effect of Er, Cr: YSGG laser irradiation on the smear layer of dentin

Taylor Dental Assisting School Course Description

Updating Recommendations for School-based Sealant Programs. Barbara Gooch DMD, MPH Division of Oral Health

Objective: To assess microleakage in conservative class V cavities prepared with

The Queen Mary Cavity Free Incremental Children s Programme

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Atraumatic Restorative Treatment - ART

Secondary Caries or Not? And Does it Matter? David C. Sarrett, D.M.D., M.S. April 3, 2009

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Dentaport ZX Reliable Apex Location Perfect Endodontics Curing with High-Powered Parallel Precision

priti crown Your patients deserve you

THE EFFECT OF STORAGE SOLUTIONS ON ENAMEL OF BOVINE TEETH

Influence of Water Storage Time on the Bond Strength of Etch-and-Rinse and Self-Etching Adhesive Systems

Minimal Intervention Dentistry: Part 2. Strategies for Addressing Restorative Challenges in Older Patients

Woodlake Dental s Tray set up A Guide on How to Prepare Dental Procedure Trays.

Rebilda DC. Rebilda Post System. Rebilda

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

Crown Dilaceration in Permanent Teeth after Trauma to the Primary Predecessors: Report of Three Cases

Totally lightweight, totally flexible, totally titanium.

Jacket crown. Advantage : Crown and Bridge

THE CLASSIC COMPOSITE FOR EXQUISITE ESTHETICS

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

A 3-Step Approach to Improving Quality Outcomes in Safety Net Dental Programs

Etching time evaluation on the shear bond strength of two adhesive systems in primary teeth

Using The Canary System to Develop a Caries Management Program for Children. we design therapies to treat or remineralize early carious lesions?

Profiles for floors of same height Cerfix Projoint

Adper Easy Bond. Self-Etch Adhesive. Your invitation to the. heavyweight showdown. November 28 30, 2010 Booth #4407.

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Class I and II Indirect Tooth-Colored Restorations

Effect of photoactivation methods and base materials on the stress generated by the polymerization shrinkage of a resin composite

School-Based Oral Health Care. A Choice for Michigan Children.indd 1

RECOATING AND RENEWING SPF ROOFING SYSTEMS

CAN ULTRASOUND APPLICATION INFLUENCE THE BOND STRENGTH OF SELF-ADHESIVE RESIN CEMENTS TO DENTIN?

Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6

The important topic of sealants was discussed during

Job Ready Assessment Blueprint. Dental Assisting. Test Code: 4026 / Version: 01

Structur. Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR

This paper summarizes current trends in the

Ando A., Nakamura Y., Kanbara R., Kumano H., Miyata T., Masuda T., Ohno Y. and Tanaka Y.

Chart 1. Chart 2. How to Use the Following Charts. Be sure to follow the legal requirements to perform dental radiographic procedures.

Dental care and treatment for patients with head and neck cancer. Department of Restorative Dentistry Information for patients

Improving your margins

Composite artistry- speedy mock up

Analysis of forces developed during root canal filling by different operators

FAQs - RelyX TM Unicem 2 Automix/Clicker

Totally lightweight, totally flexible, totally titanium.

Application Instructions for Avery Dennison Films SF S LTR EZ RS, Conform Chrome

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

ARTICLE DENTAL ASSISTANTS CHAPTER DUTIES

DENTAL FOR EVERYONE SUMMARY OF BENEFITS, LIMITATIONS AND EXCLUSIONS

Press Abutment Solutions

Scotch-Weld. Low-Odor Acrylic Adhesives DP810 DP810 NS. Technical Data June, 2004

Lesson 2: Save your Smile from Tooth Decay

ADA Standards Committee on Dental Products National Standards Status of Projects. Standard # Title of Standard WG Status Activity

THE VOICE OF TECHNO-CLINICAL DENTISTRY

Full Crown Module: Learner Level 1

Preventive Care Solutions. Clinpro White Varnish With Tri-Calcium Phosphate. It s good to have a little. extra protection

Ohio Department of Health. School-based Dental Sealant Program Manual Bureau of Community Health Services and Patient-Centered Primary Care 2012

20TDNH 214. Course Description:

Surface Engineering Solutions Rebuild, Repair and Protect Industrial Equipment

Universal Crown and Bridge Preparation

R44 SERVICE BULLETIN SB-89 (supersedes R44 Safety Alert dated 23 February 2015)

everstick everstick fibre reinforcements in orthodontics Clinical Guide Reliable anchorage Aesthetic retention everstick ORTHO

Wecryl Waterproofing System under surfacing supplied by others

Clinpro. White Varnish with Tri-Calcium Phosphate. Protection that delivers better performance. NEW with Tri-Calcium Phosphate

3 Scotch-Weld TM. Epoxy Adhesive DP110 Translucent and Gray. Technical Data December, 2009

Powertome Assisted Atraumatic Tooth Extraction

GUIDELINES FOR HANDLING FABRICATION INSTALLATION AND CLEANING

WATERPROOFING OF WET ROOMS

stone model bonding tray improve the accuracy

Dental Assistant Job Description

Humana Health Plans of Florida. Important:

Your child s heart problem and dental care

Buy 1, Get 1 FREE! (Refills: Contain 2 Syringes (2g each), 20 Dispensing Tips, Technique Guide, Direction for Use)

Richmond Crown- A Conventional Approach for Restoration of Badly Broken Posterior Teeth

Preventive Care Solutions. Clinpro. Comfortable Oral Care. The healthy. smile concept. Clinpro Prophy Powder Clinpro Prophy Paste

DISTRICT OF COLUMBIA MUNICIPAL REGULATIONS FOR DENTAL ASSISTANTS

The Water Race: Hydrophobic & Hydrophilic Surfaces

Formation of Oriented Fibers Using Injection of PEO Solutions inside Electric Fields Defined by Two Parallel Suspended Electrodes

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

Tooth Decay. What Is Tooth Decay? Tooth decay happens when you have an infection of your teeth.

Technical Data Sheet February 2014

First Dental Visit by Age One

Transcription:

50 Braz Dent J (2010) 21(1): 50-54 M.C. Borsatto et al. ISSN 0103-6440 Bonding Agent Underneath Sealant: Shear Bond Strength to Oil-Contaminated Enamel Maria Cristina BORSATTO 1 Michelle Yamamoto THOMAZ 1 Marta Maria Martins Giamatei CONTENTE 1 Jaciara Miranda GOMES-SILVA 1 Talitha de Siqueira MELLARA 1 Rodrigo GALO 2 Regina Guenka PALMA-DIBB 3 1 Department of Pediatric Clinics, Preventive and Community Dentistry, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, SP, Brazil 2 Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, SP, Brazil 3 Department of Restorative Dentistry, Ribeirão Preto Dental School, University of São Paulo, Ribeirão Preto, SP, Brazil This study evaluated in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with either an ethanol-based (Adper Single Bond 2 - SB) or an acetone-based (Prime & Bond - PB) adhesive system under conditions of oil contamination. Mesial and distal enamel surfaces from 30 sound third molars were randomly assigned to 2 groups (n=30): I - no oil contamination; II - oil contamination. Contamination (0.25 ml during 10 s) was performed after 37% phosphoric acid etching with an air/oil spray. The specimens were randomly assigned to subgroups, according to the bonding protocol adopted: subgroup A - F was applied to enamel without an intermediate bonding agent layer; In subgroups B and C, SB and PB, respectively, were applied, light-cured, and then F was applied and light-cured. Shear bond strength was tested at a crosshead speed of 0.5 mm/min in a universal testing machine. Means (± SD) in MPa were: IA-11.28 (±1.84); IIA-12.02 (±1.15); IB-9.73 (±2.38); IIB-9.62 (±2.29); IC-28.30 (±1.63); and IIC-25.50 (±1.91). It may be concluded that the oil contamination affected negatively the sealant bonding to enamel and the acetone-based adhesive system (PB) layer applied underneath the sealant was able to prevent its deleterious effects to adhesion. Key Words: pit-and-fissure sealant, shear bond strength, oil contamination, adhesive system. INTRODUCTION In the light of the contemporary dental principles, as often as possible, noninvasive strategies have preferably been instituted rather than invasive healing treatments (1). Efforts have been focused on reducing patients risk for caries by stimulating the adoption of preventive measures and highlighting the relevance of a partnership approach between patients and dentists for the ultimate success of caries control. Caries risk assessment is also an essential step to provide an individualbased, comprehensive treatment planning. The high susceptibility of pits and fissures to carious attack and the rapid onset of the disease at these sites soon after tooth eruption are reported by several studies. In this context, treating caries-susceptible pits and fissures with resin sealants has been considered an outstanding adjunctive resource to oral health care strategies and fluoride therapy to decrease occlusal caries initiation and/or progression (2). Nevertheless, the preventive benefits of such treatment rely directly upon the ability of the sealing material to thoroughly fill pits, fissures, and/or anatomical defects and remain completely intact and bonded to the enamel surface Correspondence: Profa. Dra. Maria Cristina Borsatto, Faculdade de Odontologia de Ribeirão Preto, USP, Departamento de Clínica Infantil, Odontologia Preventiva e Social, Avenida do Café, s/n, Monte Alegre, 14040-904 Ribeirão Preto, SP, Brasil. Tel: +55-16-3602-4114. Fax: +55-16-3633-0999. e-mail: borsatto@forp.usp.br

Bonding agent underneath sealants 51 for a lifetime, thus preventing caries from developing underneath the sealant restoration (3). Low utilization of sealants has been attributed to lack of confidence in their bonding to enamel and to the difficulty of achieving adequate dry field isolation (4). Salivary pellicle, moisture, organic debris, blood and oil from air compressors and from hand-pieces have been also identified as potential contaminants of tooth surfaces that may lead to bonding failure (5). Total etching with 30-40% phosphoric acid, rinsing and drying the surface to obtain a uniformly white, dull, chalk-like appearance is one of the steps on the sealant technique. In this context, the presence of oil in the air/water syringes from air compressors could create a potential source of contamination coating the enamel surface after the acid etching step. This contamination must be a matter of concern to the professional, since their presence is relatively unknown, and their results are unexpected. Several studies have shown the benefits of adding a bonding agent layer between the etched enamel and the sealant to increase the bond strength in the face of moisture and salivary contamination (6-8). The literature is still scarce in articles investigating the oil contamination of tooth substrates and its effects on adhesion (9-12). In addition, there appear to be no study evaluating the sealant technique and the association of adhesives systems as intermediary bonding agents prior to sealant placement under conditions of oil contamination. Therefore, this study assessed in vitro the shear bond strength of a resin-based pit-and-fissure sealant associated with 2 adhesives systems as intermediate agents under air compressor oil contamination. MATERIAL AND METHODS This study was approved by the Research Ethics Committee of Ribeirão Preto Dental School, University of São Paulo. Freshly extracted sound human third molars were hand scaled and cleaned with water/ pumice slurry in rotating bristle brushes to remove calculus and root-adhered debris, and were examined under a 20 magnifier to discard those with structural defects. Thirty teeth were selected for the study and stored in 0.9% saline with 0.4% sodium azide at 4 C. Prior to use, the teeth were washed in running water to eliminate storage solution residues, the roots were removed 3 mm below the cementoenamel junction and the crowns were embedded in polyester resin using polyvinyl chloride rings (2.1 cm diameter and 1.1 cm height). After resin polymerization, the rings were discarded and the mesial and distal enamel surfaces were ground wet with #320- to #400-grit silicon carbide (SiC) papers (Buehler Ltd., Lake Bluff, IL, USA) in a low-speed polishing machine (Politriz DP-9U2; Struers, A/S, Copenhagen, Denmark). The specimens were then hand polished with wet #600-grit SiC paper to obtain flat, smooth test surfaces, which were cleaned by rubber cup/pumice prophylaxis for 10 s. For standardization, the bonding sites were demarcated by attaching a piece of insulating tape with a 3-mm-diameter central hole on was attached to each surface. The 60 test surfaces were randomly assigned to 2 groups (n=30) of equal size, as follow: I - oil contamination; II - no oil contamination. In oil contaminated group, before the adhesive system/ sealant application, the acid-etched enamel bonding site was contaminated for 10 s with one spray (25 µl) of air/oil from air compressor at a distance of 2 to 3 cm, covering the enamel surface to be bonded. The enamel surfaces were etched with a 35% phosphoric acid gel (Scotchbond etchant; 3M/ESPE, St. Paul, MN, USA ) for 15 s, rinsed thoroughly for 15 s, dried with a mild, oil-free air stream to obtain a uniformly white, dull, chalk-like appearance. The following materials were tested: a filled resin-based pit-and-fissure sealant [Fluroshield; Dentsply/Caulk, Milford, DE, USA] and single-bottle ethanol-based adhesive system [Adper Single Bond 2; 3M ESPE] and a single-botlle acetone-based adhesive system [Prime & Bond 2.1; Dentsply/Caulk] were used according to manufacturers instructions. Then the groups were randomly assigned to 3 subgroups, according to the bonding protocol adopted. Subgroup A - Fluroshield was applied to the demarcated etched enamel site and light-cured for 20 s. Subgroup B - Adper Single Bond 2 (SB) was applied to the etched enamel bonding site in a uniform layer, slightly thinned with a mild, oil-free air stream and light-cured for 10 s with a visible light curing unit (XL 3000; 3M/ESPE) with 450 mw/cm 2 output, as measured with a curing radiometer (Demetron Research Corp., Danbury, CT, USA). Next, Fluroshield was applied and light-cured for 20 s. Subgroup C - A uniform layer of Prime & Bond 2.1 (PB) bonding agent was applied as described in subgroup B and light-cured for 20 s with the same light

52 M.C. Borsatto et al. curing unit. Next, Fluroshield was applied and lightcured for 20 s. The tested adhesive system and the sealant were carefully applied to tooth surface with disposable brush tips (Microbrush Corporation, Orlando, FL, USA) to avoid excess and pooling of adhesive along the edges of the insulating tape that could affect tension distribution during the shearing test and the validity of results. After completion of the bonding protocols, the specimens were individually fixed in a metallic clamping device (developed at the Houston Biomaterials Research Center, University of Texas Dental Branch, Houston, TX, USA and manufactured at the Precision Workshop of Ribeirão Preto Dental School, University of São Paulo, Brazil)that secured the test dentin surface parallel to a flat base. A split bisected polytetrafluoroethylene jig was positioned on the tooth/resin block, providing a cylindrical cavity (4 mm high x 3 mm diameter) that was coincident with the demarcated enamel bonding site. Sealant was inserted into the jig in increments, each polymerized for 20 s. As the cavity was filled, the specimen was released from the clamping device and jig, leaving a sealant cylinder (4 mm x 3 mm) adhered to the enamel surface. After 24-h storage in distilled water at 37 º C, shear bond strength was determined using a knife-edge blade in a universal testing machine (Mod. MEM 2000; EMIC Ltda, São José dos Pinhais, PR, Brazil) at a crosshead speed of 0.5 mm/min with a 50 kgf load cell. The means (in MPa) and standard deviations were calculated and data were analyzed statistically by one-way ANOVA. Because sample distribution was not normal, the t-test non-parametric test was used for multiple comparisons at 1% significance level. RESULTS Shear bond strength means and standard deviations for oil-contaminated and non-contaminated groups are shown in Table 1. No statistically significant difference (p>0.01) was observed among subgroups IA, IIA, IB and IIB, which means that sealant association with the ethanolbased adhesive system did not prevent the deleterious effects of oil contamination on adhesion. The association of Prime Bond 2.1 adhesive system to Fluroshield sealant increased the shear bond strength with significantly higher mean bond strength values (p<0.01) compared to the others subgroups. DISCUSSION Adhesive procedures can be compromised by field contamination that results in a decrease in bonding strength (9-11). The presence of oil in the air/water syringes from air compressors could create a potential source of contamination coating the enamel surface on the sealant application technique, since rinsing and drying the surface to obtain a uniformly white, dull, chalk-like appearance is required after the acid etching step. Effective oil filters on air lines are not used in most dental offices and thus the oil that comes from air compressors provides an unpredictable clinical outcome and a potential negative factor in dental adhesion because its presence is relatively unknown, and their results are unexpected. Air pureness depends on the presence of effective filters and adequate maintenance of compressors (5). The literature is still scarce in articles investigating oil contamination on dental substrates and its effects on adhesion. In the present study, it was observed that oil contamination affected negatively the resin sealant bonding to enamel. Enamel was contaminated after acid etching in order to simulate the clinical situation of drying (with oil contaminated compressed air lines) the enamel surface during sealant placement. Some authors (11,12) have reported that handpiece oil contamination before the application of the adhesive system interfered Table 1. Shear bond strength means (MPa) to the experimental groups. Subgroups IA - F applied to noncontaminated enamel IB - SB and F applied to noncontaminated enamel IIA - oil contamination + F IIB - oil contamination + SB and F IC - PB and F applied to noncontaminated enamel IIC - oil contamination + F and PB Means (±SD) 12.28±1.84a 12.02±1.15a 9.73±2.38a 9.62±2.29a 28.30±1.63b 25.50±1.91b Fluroshield = F; Adper Single Bond 2 = SB; Prime & Bond = PB. Different letters indicate statistically significant difference (p<0.01).

Bonding agent underneath sealants 53 with bonding to enamel. However, others authors (9,10) stated that handpiece lubricant did not significantly affect enamel bond strengths. Rosa et al. (13) observed little effect on bonding of adhesive systems to enamel under handpiece oil contamination performed after acid etching. It is important to point out that different types of adhesive systems were tested by those authors. Additionally, to the best of our knowledge, no study has yet evaluated oil contamination on sealant technique. Over the last decades, the application of an intermediate bonding agent layer underneath the sealant has been widely suggested. The findings of several studies (4,6,14-17) have shown that the use of adhesive systems along with resin sealants may improve bonding to etched enamel under dry and contamination conditions. It is likely that solvents, such as ethanol and acetone, present in the currently available single-bottle adhesives are able to remove any residual moisture from the etched enamel, carrying the resin monomers into close adaptation with the surface (15,18). Furthermore, the hydrophilic monomers present in these materials increase the surface wetting and resin penetration, counteracting the adverse effects of organic contamination (saliva or oil) on bonding to tooth structure (17). In the present study the association of the sealant with Prime & Bond adhesive system increased the bond strength to enamel. The ethanol-based adhesive system used in the present study (Single Bond) contains water as a co-solvent, which produces lower volatility compared to the acetone-based adhesive system (Prime & Bond). This cleansing effect of the acetone solvent could be responsible for the higher bond strength obtained for the sealant associated with Prime & Bond adhesive system. The lack of reported studies testing the same methodology and materials did not allow stating a reliable comparison with outcomes in the literature. It is important to emphasize that this paper in no way suggests that improper technique for sealant placement can be advocated at all. However, it is estimated that a large number of dental offices have oil contamination in their air lines (5), although manufacturers recommend periodic changes of the filters. Thus, contamination of etched enamel might occur. Our expectation is that the findings of this study may help improveing clinician confidence in sealant success, even in circumstances of application that are far less than ideal. Based on the findings of this study and within the limitations of an in vitro investigation, the following conclusions can be drawn: 1. Oil contamination affected negatively the resin sealant bonding to enamel; 2. Sealant association with the acetone-based adhesive system was able to prevent the deleterious effects of oil contamination on adhesion. RESUMO Este estudo avaliou in vitro a resistência ao cisalhamento (RC) de um selante resinoso [Fluroshield (F); Dentsply/Caulk] em associação com um sistema adesivo com solvente a base de etanol [Adper Single Bond 2 (SB); 3M/ESPE] ou a base de acetona [Prime & Bond (PB); 3M/ESPE] após contaminação com óleo do esmalte. Superfícies mesiais e distais de esmalte de 30 terceiros molares hígidos foram aleatoriamente alocadas em 2 grupos (n=30): I - contaminação com óleo; II - sem contaminação. A contaminação foi realizada (0,25 ml;10 s) com um jato de ar/ óleo após o condicionamento do esmalte com ácido fosfórico a 37%. Os espécimes foram aleatoriamente alocados em subgrupos, de acordo com a técnica adesiva empregada: A - F foi aplicado sobre o esmalte condicionado sem sistema adesivo; B - SB + F; C - PB + F. RC foi testada em uma máquina universal de ensaios (0,5 mm/min; 50 kgf) e os dados analisados por ANOVA e t-teste (α=0,01). As médias de RC em MPa foram: IA-11,28 (±1,84); IIA-12,02(±1,15); IB-9,73 (±2,38); IIB-9,62 (±2,29); IC-28,30 (±1.63); e IIC-25,50 (±1,91). Conclui-se que a contaminação com o óleo afetou a adesão do selante resinoso ao esmalte e o sistema adesivo com solvente a base de acetona (Prime & Bond) aplicado sob o selante foi capaz de impedir os efeitos deletérios da contaminação com óleo. REFERENCES 1. Lygidakis NA,Dimou G,Stamataki E.Retention of fissure sealants using two different methods of application in teeth with hypomineralised molars (MIH): A 4 year clinical study. Eur Arch Paediatr Dent 2009;10:223-226. 2. Splieth CH, Ekstrand KR, Alkilzy M, Clarkson J, Meyer- Lueckel H, Martignon S et al.. Sealants in Dentistry: Outcomes of the ORCA Saturday Afternoon Symposium 2007. Caries Res 2010;44:3-13. 3. Dennison JB, Straffon LH, Smith RC. Effectiveness of sealant treatment over five years in an insured population. J Am Dent Assoc 2000;131:597-605. 4. Hevinga MA, Opdam NJ, Frencken JE, Bronkhorst EM, Truin GJ. Microleakage and sealant penetration in contaminated carious fissures. J Dent 2007;35:909-914. 5. Gooch BF, Griffin SO, Gray SK, Kohn WG, Rozier RG, Siegal M et al.. Preventing dental caries through school-based sealant programs: updated recommendations and reviews of evidence. J Am Dent Assoc 2009;140:1356-1365. 6. Gomes-Silva JM, Torres CP, Contente MM, Oliveira MA, Palma- Dibb RG, Borsatto MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347. 7. Borsatto MC, Corona SA, Alves AG, Chimello DT, Catirse AB, Palma-Dibb RG. Influence of salivary contamination on marginal microleakage of pit and fissure sealants. Am J Dent 2004;17:365-

54 M.C. Borsatto et al. 367. 8. Torres CP, Balbo P, Gomes-Silva JM, Ramos RP, Palma-Dibb RG, Borsatto MC. Effect of individual or simultaneous curing on sealant bond strength. J Dent Child 2005;72:31-35. 9. Xie J, Powers JM, McGuckin RS. In vitro bond strength of two adhesives to enamel and dentin under normal and contaminated conditions. Dent Mater 1993;9:295-299. 10. Powers JM, Finger WJ, Xie J. Bonding of composite resin to contaminated human enamel and dentin. J Prosthodont 1995;4:28-32. 11. Knight JS, Draughn R, Evans MD. Effects of handpiece lubrication on resin-based composite bond strength to enamel. Am J Dent 1999;12:1116-1118. 12. Matos AB, Oliveira DC, Vieira SN, Netto NG, Powers JM. Influence of oil contamination on in vitro bond strength of bonding agents to dental substrates. Am J Dent 2008;21:101-104. 13. Rosa BT, Heymann HO, Swift EJ, Perdigão J, Ritter AV. Shear bond strength of one-bottle adhesive to oil-contaminated enamel. J Esthet Dent 2000;12:139-145. 14. Choi JW, Drummond JL, Dooley R, Punwani I, Soh JM. The efficacy of primer on sealant shear bond strength. Pediatr Dent 1997;19:286-288. 15. Fritz UB, Finger WJ, Stean H. Salivary contamination during bonding procedures with a one-bottle adhesive system. Quintessence Int 1998;29:567-572. 16. Tulunoglu O, Bodur H, Uctasli M, Alacam A. The effect of bonding agents on the microleakage and bond strength of sealant in primary teeth. J Oral Rehabil 1999;26:436-441. 17. Gomes-Silva JM, Torres CP, Contente MMMG, Oliveira MAHM, Palma-Dibb RG, Borsatto MC. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing. Braz Dent J 2008;19:341-347. 18. Hebling J, Feigal RJ. Use of one bottle adhesive as an intermediate bonding layer to reduce sealant microleakage on saliva-contaminated enamel. Am J Dent 2000;13:187-191. Accepted March 17, 2010