Model PX-3.1 Position Transmitter

Similar documents
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Contents. Document information

Servo Info and Centering

Service Information CALIBRATION PROCEDURE AND TROUBLESHOOTING FOR LINEAR GOVERNOR CONTROLLERS NOTE

WE-350 Series ¼ Turn Electric Actuator

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Telefon (+45) Telefax (+45) Installation and operating manual

Lab 3 - DC Circuits and Ohm s Law

PRODUCT PROFILE FEATURES

A descriptive definition of valve actuators

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

OPL BASIC. Dosing System for Professional Laundry machines. Contents

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

GLOLAB Two Wire Stepper Motor Positioner

Know-how makes the difference. Electrical Actuators

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Duct Humidity Transmitter

Loop Calibration and Maintenance

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

HQ Series ¼ Turn Actuator

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Owner's Copy December 14, 2011 ELECTRICAL INSTRUCTIONS FOR ADVANTEX EA OR EX MODELS

MDC Series

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Electric Rotary Actuator - On/Off or programmable control actuator

Air damper actuators

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Sanitary Type Electronic Flow Switches

Kit Watt Audio Amplifier

Sierra S-Series Smart Interface Software User Manual

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

Fuel Injection Pump, Rotary ( )

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

A1000 Cheat Sheet (Open Loop Vector)

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Modular I/O System Analog and Digital Interface Modules

Proximity Switches RS (Reed Switch)

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

OPERATION MANUAL VALVE CHECKER G

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ECEN 1400, Introduction to Analog and Digital Electronics

Electric Actuator Smart Controller

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Talon and Talon SR User Manual

2-Pair HDSL1 Adtran Fiber Optic Link System

Combustible Gas Transmitter RK-05

Current Loop Application Note 1495

Operating Instructions. UL325 Compliant Non-monitored

Troubleshooting and Diagnostics

Gas Turbine Fuel Control Valve

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

PTU Series Ultrahigh-Purity Pressure Transducers

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Electronic Flow Switches

Series 71, 72, and 76 Modutrol IV Motors

Fire Fighter Phone System Installation Instructions

Model 201 Wiegand Touchpad Reader Installation Guide

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Gemini II. Subwoofer System OWNERS MANUAL

Water Leak Detection System

Absolute Rotary Encoder E6CP

Worcester DS/DM Series UltraSwitch Switch box

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

TC-9102 Series Surface Mount Temperature Controllers

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

12-Volt Negative Ground Installation Instructions

12 Volt 30 Amp Digital Solar Charge Controller

In-Line Electronic Flow Switches

Automatic Voltage Regulator User s Manual

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

289 SERIES FLOW METER TRANSMITTERS

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Model 43AP Pneumatic Controller, Style B

INSTALLATION/PROGRAMMING INSTRUCTIONS 928 ENTRYCHECK

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

PHD User Manual. Table of Contents

Build A Video Switcher. Reprinted with permission from Electronics Now Magazine September 1997 issue

INSTRUCTION MANUAL. SIGNAL AMPLIFIER 4-20 ma

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

Unit 24: Applications of Pneumatics and Hydraulics

Nokeval. User's Manual Models 301 / 302 / 305

HYDRA HV OPERATION MANUAL. 2.0 Making Connections on your HYDRA speed control. Rosin core electrical solder

Odyssey of the Mind Technology Fair. Simple Electronics

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

QR12 (1.22 ) Diameter Optical Encoder

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

ABB Drives. User s Manual HTL Encoder Interface FEN-31

USER MANUAL. EZRUN Series Brushless Speed Controller EZRUN-150A-PRO

Servo Motors (SensorDAQ only) Evaluation copy. Vernier Digital Control Unit (DCU) LabQuest or LabPro power supply

Global Motion Technology Inc Web THCSA200. Capacitive sensor plasma & Oxy-fuel Torch Height Control

Transcription:

Document # 027-0026-0403 Copyright 1990-2003 by Thunderco, Inc. P.O. Box 920795 909 Fisher Street Houston, Texas 77292-0795 Ph:713-681-4686/Fax:713-681-4688 All Rights Reserved This document replaces all previous editions. Contents Description... 2 Specifications... 2 Features... 3 Mounting Dimensions... 4 Wiring Diagram... 4 Calibration &/or Changing Measurement Range... 5 Reversing the Output... 7 Circuit Card Replacement... 8 T-9000 I/H Interface Devices Model PX 3.1-1

Description The PX-3.1 is a rotary position transmitter that outputs a linear 4-20 ma DC instrument signal based on the resistance change of a rotary potentiometer. The PX-3.1 electronics are housed in an explosion proof enclosure that can be mounted to an adaptor designed for your device. There are a variety of feedback shaft options available. Included with the Model PX-3.1 are two end of travel adjustable limit switches. Side view, Model PX-3.1 The Model PX-3.1 can be directly coupled to rotational devices such as ball or butterfly valves or lever driven for position measurement of linear devices such as globe or gate valves. The Model PX-3.1 replaces the Model PX-3 & is field upgradable through circuit card replacement. Calibration procedures are simplified and do differ. Specifications Supply voltage: 18-40 VDC Output: 4-20 ma DC, proportional to travel Loop Load: 1000 Ohms @ 18 VDC, 1200 Ohms @ 24 VDC Operating Temperature Range: -40 deg. F to 180 deg. F Field Adjustable Travel Range (+/- 15 deg.): 60 deg., 90 deg., 120 deg. Housing:Explosion Proof for NEC Class 1, DIV. 1, Group D. Designed for Nema 4, 4X, 7, & 9 Adaptors: A variety of input shaft arrangements are available Limit Switches: Standard Mechanical Limit Switch 2 SPDT, 10 Amp AC/DC Optional Proximity Limit Switch 2 SPST, 100 ma max @ 10-30 VDC cam adjustable T-9000 I/H Interface Devices Model PX 3.1-2

Features Loop powered for easy installation Simple field calibration Field reversible output Top view, Model PX-3 Field adjustable to 60, 90 and 120 degree rotation with adjustment of +/- 15 degrees for each range 2 adjustable, end of stroke limit switches Side view, Model PX-3 T-9000 I/H Interface Devices Model PX 3.1-3

Mounting Dimensions Model PX-3 Position Transmitter showing various output shaft configurations with side & bottom views Wiring Diagram (+) (-) 24-40 VDC power supply Measurement display, recorder, SCADA, etc.(1200 Ohms max.) The Model PX-3.1 is a loop powered transmitter that requires a 24-40 VDC power supply and current loop display or measurement device such as a Thunderco Model LPD-3.5 loop powered display, SCADA system, programmable controller or feedback electronics such as the Thunderco Model 5591 or 9020 I/H Controller Interface Note: Loop position does not matter. Limit switches require 2 wires each if used. Limit switch wiring not shown. (+) Red Model PX-3 (-) Black T-9000 I/H Interface Devices Model PX 3.1-4

Calibration &/or Changing Measurement Range Loosen the lower two set screws on the flexible coupling that is attached to the blue feedback potentiometer. This will allow adjustment of the feedback potentiometer during calibration. Side view, Model PX-3 Remove the jumper on the bottom side of board 103-0148 at the location shown. This will break the current loop. Place a current meter across the two pins. This procedure will place your meter in series with the current loop and allow you to read the 4-20 ma measurement signal from the PX-3.1. Note: When calibration is completed this jumper must be put back in place after the current meter is removed or the current loop will be open. Top view, Circuit Board 103-0148 T-9000 I/H Interface Devices Model PX 3.1-5

Calibration & / or Changing Measurement Range (con't) Move the programming shunt on the daughter board #103-0155 to the position corresponding to the desired measurement range. Power up the transmitter observing the current meter in series with the current loop. Circuit Board 103-0155 Special PX-3.1-30 Rotation Shunt +/- 5 Degrees 0-25 1 0-30 2 0-35 3 Standard PX-3.1 Rotation Shunt +/- 15 Degrees 0-60 1 0-90 2 0-120 3 Caution: For early models only: Disconnect the power immediately if the current in the current loop is above 50 ma and rotate potentiometer to decrease the current and try again. Calibrate transmitter. Do not hookup backwards or damage to the circuit card may result. On newer models a diode protects against reverse polarity installation and no current is seen if unit is hooked up backwards. -Rotate the feedback potentiometer until a minimum current value is seen before it goes into the dead zone of the 330 degree potentiometer (the dead zone will generate current above 25 ma). Adjust the zero potentiometer until approximately 3.6-3.8 ma is read on the current meter. Make a slight movement of the feedback potentiometer in the current increasing direction and verify current change. It is possible to install incorrectly so that no current change occurs for the first few degrees of movement due to the dead zone of the potentiometer. Rotate the potentiometer until 4.0 ma is output. Tighten set screws. This is a coarse adjust only. -Fine adjust the "ZERO" potentiometer to 4.00 ma output. -Rotate the measured device to its full span position. -Adjust the "SPAN" potentiometer to 20 ma output. -Repeat "ZERO" and "SPAN" adjustment. They are interactive. -Remove the current meter and replace the jumper at the test pins. T-9000 I/H Interface Devices Model PX 3.1-6

Reversing the Output To reverse the output, move the shunts on header shown. Normal output (4 ma @ close, current increases in a counter-clockwise direction looking at the cover of the enclosure) Shunt at pin locations 1 & 3 Circuit Board 103-0155 Reversed output (4 ma @ open, current increases in a clockwise direction) Shunt at pin locations 2 & 4 T-9000 I/H Interface Devices Model PX 3.1-7

Circuit Card Replacement Remove screws holding the circuit card in place. red(+) black(-) Top view, Model PX-3 Loosen lower 2 setscrews on flexible coupling and remove circuit card. Loosen upper 2 setscrews on flexible coupling and move the coupling to the new circuit card, re-tighten upper setscrews. Side view, Model PX-3 Re-assemble the transmitter using the new circuit card. If you are upgrading from a Model PX-3 to a PX-3.1, an additional pair of standoffs is required and should be included in the upgrade card package. Follow calibration procedures outlined in previous section. T-9000 I/H Interface Devices Model PX 3.1-8