IDENTIFICATION OF GLASSWARE, PH METER, SPECTROPHOTOMETER

Similar documents
Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Phenolphthalein-NaOH Kinetics

Measurement and Calibration

The Determination of an Equilibrium Constant

The introduction of your report should be written on the on the topic of the role of indicators on acid base titrations.

COMMON LABORATORY APPARATUS

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

A Beer s Law Experiment

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Calibration of Volumetric Glassware

Calibration of Volumetric Glassware

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp , 699

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Lab #11: Determination of a Chemical Equilibrium Constant

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

EXPERIMENT 10: TITRATION AND STANDARDIZATION

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Using the Spectrophotometer

Factors Affecting Enzyme Activity

Laboratory 5: Properties of Enzymes

3 The Preparation of Buffers at Desired ph

Determination of the Mass Percentage of Copper in a Penny. Introduction

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

THE ACTIVITY OF LACTASE

Color, True and Apparent

Acid Base Titration: ph Titration Curve

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

Experiment 7: Titration of an Antacid

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Color, True and Apparent

Use of Micropipettes

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

Neutralizing an Acid and a Base

2 Spectrophotometry and the Analysis of Riboflavin

The Determination of an Equilibrium Constant

Lab 5: Quantitative Analysis- Phosphates in Water By: A Generous Student. LBS 171L Section 9 TA: Dana October 27, 2005

Experiment 6 Titration II Acid Dissociation Constant

Concentrations and Dilutions of Food Dyes

Measuring Protein Concentration through Absorption Spectrophotometry

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Colorimetric Determination of Iron in Vitamin Tablets

HiPer Ion Exchange Chromatography Teaching Kit

Acid Base Titrations

ph: Measurement and Uses

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

EXPERIMENT INTRODUCTION TO INDICATORS AND ACID-BASE TITRATIONS

CHEM 161: Beer s Law and Analysis of a Sports Drink

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off:

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

NITRIC OXIDE and NITROGEN DIOXIDE 6014

catalase 2H 2 O 2 (l) ----> 2H 2 O (l) + O 2 (g)

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

Quaternary Ammonium Compounds DOC

Vitamin C Content of Fruit Juice

Colorimetric Determination of Iron in Vitamin Tablets

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Standardization of Potassium Permanganate solution with Standard Sodium Oxalate Solution.

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Free SO 2. by Aeration-Oxidation. A n o t h e r M o r e M a n u a l!

ph Measurements of Common Substances

Acid-Base Titrations Using ph Measurements

Chemistry 118 Laboratory University of Massachusetts Boston Beer s Law

Spectrophotometric Determination of the pka of Bromothymol Blue

EXERCISE # 1.Metric Measurement & Scientific Notation

Experiment 1: Measurement and Density

How to prepare standard solutions

Chem 131A: Absorbance of Riboflavin

Determination of the amount of sodium carbonate and sodium hydroxide in a mixture by titration.

Acetic Acid Content of Vinegar: An Acid-Base Titration E10-1

18 Conductometric Titration

Chem 405 Biochemistry Lab I Experiment 2 Quantitation of an unknown protein solution.

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

Lab 2. Spectrophotometric Measurement of Glucose

Experiment 4 (Future - Lab needs an unknown)

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

Table of Content. Enzymes and Their Functions Teacher Version 1

Phosphates (ortho- and total)

Properties of Acids and Bases

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

Measuring Manganese Concentration Using Spectrophotometry

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

EDTA Titrations 1: Standardization of EDTA and Analysis of Zinc in a Supplement Tablet. by Professor David Cash. September, 2008

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

EXPERIMENT 4 Acid Strength

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

Simulation of the determination of lead azide content in waste water from explosives manufacture

2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials

Transcription:

IDENTIFICATION OF GLASSWARE, PH METER, SPECTROPHOTOMETER

AIMS Identify different glassware and the accuracy of them To be familiar with the use of pipetting technique To learn how to handle the ph meter and to measure ph values To learn how to handle the spectrophotometer

GLASSWARE 1-Conical flasks and beakers: They are used for mixing, transporting and reacting, but not for accurate volume measurements. Conical flasks beakers

2-Graduated cylinders: They are for general purpose use, but not for quantitative analysis. If greater accuracy is needed, use a pipette or volumetric flask. 3-Burettes: It is used to deliver solution in precisely-measured, variable volumes. Burettes are used primarily for titration

4-Volumetric flasks: It is used to make up a solution of fixed volume very accurately. 4) Pipettes: A pipette is used to measure small amounts of solution very accurately. Two types of pipettes commonly used are transfer pipettes and measuring pipettes.

PIPETTING TECHNIQUES Transfer pipettes(volumetric) designed to deliver accurately a fixed volume of liquid Not graduated consist of a cylindrical bulb joined at both ends to narrowed glass tubing More accurate than measuring pipettes Non-blown out Measuring pipettes(graduated) Graduated Some are blown out There are two types: Mohr and serological

MEASURING PIPETTES(GRADUATED) Mohr Graduated between two marks Serological Pipettes with graduation mark down to the tip

SMALLEST DIVISION OF GRADUATED PIPETTE How to know the smallest division of a pipette: 1 1 0.1 0.1 2 2 0.2 0.2 Smallest division: 0.1 ml Smallest division: 0.2 ml

HOW TO USE PIPETTES The pipette first should be washed with water Then rinsed with a little of the solution to be used. Why? The bottom of the curved surface is read at eye level and the volume measurement is read to the proper number of significant digits The solution is allowed to drain into the appropriate vessel with the jet of the pipette touching the wall of the vessel

PH METER Hydrogen ion concentration of many solution is low and difficult to measure accurately. So, the term ph introduced as a way of expressing hydrogen ion concentration. PH define as the negative logarithm of the hydrogen ion concentration. PH = - log10 [H+]

Since the PH determines many important aspects of the structure and activity of biological macromolecules and thus of the behavior of the cell and organisms. Note: PH range value (0-14),, the higher PH number, the lower the hydrogen ion concentration and vice versa..

There are many ways in biochemical laboratory to measure PH value such as ; and litmus s paper, a field kit PH meter. The most accurate and reliable method is

HCl (0.1N) Note: before use it needs to be calibrated The glass electrode

SPECTROPHOTOMETER spectrophotometer is instrument used to measure the intensity of light at a given wavelength that is transmitted or absorbed by a sample. *Wavelength in this instrument divided into: -Invisible range(ultraviolet) from 100 to 360 nm [Quartz cuvette are used] -Visible range (400-700 nm) [Glass or plastic cuvette are used] Blank: contain everything except the compound to be measure.

Four parts: METHOD 1-Examine the 3 pipettes A,B, and C record their types and smallest division Using distilled water, pipette a

1-standardize the PH meter by placing the electrode in a solution of known PH(PH 4, 7, 9). 2-Wash the electrode with distilled water and dry by tissue then put it into sample solution A & B, read PH. Note: After use the electrode you should storage it in distilled water and never be allowed to dry out.if the electrode get dry it will required reactivation.

- Adjust the spectrophotometer to zero using blank solution in the cuvette and read the absorbance of standard solution and the solution of unknown concentration at 280 nm. - Read your result in the table below: - Calculate the concentration of unknown solution from the following formula: Au x Cs As Where Au= Absorbance of the solution of unknown concentration As= Absorbance of the solution of standard solution Cs= concentration of standard solution - Concentration of unknown solution is =