Datasheet. OSRAM SubstiTUBE Trio 2

Similar documents
Innovative. Lum. Flux** [lm]

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

Radiance Angle [ ] Color Temp. [K]

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

IVIOS LED III. LUM Technical Information

Product Information. LED SUPERSTAR MR Adv. Product Overview. Benefits. Key Features

DuroSite TM High Bay Lighting

LED SUPERSTAR MR Product description

KIT DOWNLIGHT HALOSPOT 111 ES

PLVZ1-LIN DC > , PLVZ1-LIN DC > ,

EC-Declaration of Conformity Annex

LED Tubular Lamp / Kit Guide

ECOPTIMO T8. Version IRIS 2002,S.A. C/San Agustin, Madrid SPAIN T F

Technical Specification

The most sustainable lighting solution. QL 85W Induction Lighting System

E-CORE LED WEATHERPROOF 2 DATA SHEET 1 / 5. Application:

QLT1500GB (120 ) QLT1500GH (60 ) 18W

Flux CCT. CRI SDCM (lm) (K) (V) (ma) (W) (lm/w)

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

Why Philips LEDtube? LED Lamps EMEA February February 2015_BG LS & E LEDlamps

2013 / ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

Product Information LED PARATHOM PAR Product Overview. Benefits. Key Features

2015 / 9C DOC-01 OSRAM GmbH Marcel-Breuer-Str München Germany. Lamp controlgear HTi DALI 105/

LIGHTING and LIGHTING SYSTEMS

T5 LongLast. GE Lighting DATA SHEET

Features. High Brightness LED Light source

120W High Bay II Datasheet

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Operating instructions II / 2004

The new generation of energy saving tube lighting

Operating instructions IV / 2007

Product Overview. & clear sparkling. Key Features. mm 150 g mm 150 g

Led lighting products

SAMSUNG ELECTRONICS LED

The right. LEDtube. every time. LEDlamps

OSRAM DULUX SUPERSTAR MICRO TWIST

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

LED High Bay Light 100W

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

High / Low Bay Datasheet

DULUX L 55 W/840 2G11

High / Low Bay Datasheet

Fortimo LED Line Gen3

9W T8 LED TUBE 2FT GENERAL INFORMATION

Lumination LED Luminaires

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA

COOL Shelf Quick Connect

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

Low / High Bay Datasheet

BSE Geluid en Licht Pagina 1 van 5. Description

LED DIMMING A HELPFUL GUIDE...

Lumination LED Luminaires

High / Low Bay Datasheet

Cree Edge and LEDway by Cree Compared to Induction Lamp Luminaires

How To Make A Light Bulb From An Osmram Dulux Lamp

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

illuminer 150W High/Low Bay Datasheet E Join the LED Revolution Solid-State Lighting Series

Application/ Requirements for LED Lighting Products Certification Scheme

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

Product Overview. & clear sparkling. Key Features. mm 150 g mm 150 g

Product Line DUST. The family of hermetic luminaires

T5 Watt-Miser Linear Fluorescent lamps

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

LED light engine / OLED LED flexible. Umodule LLE-FLEX umodule LLE FLEX ADVANCED

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

Product and functional description

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

ENERGY SAVING CATALOGUE

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

STRATO LED Drivers 70W, Single output

Why Philips LEDtube? Leander Bloot Product marketing LEDtubes LED Lamps EMEA January January 2014_BG LS & E LEDlamps

Low Bay High Bay. Lighting. Industrial Series. The best lighting level for better working performance.

Industrial plastic LED light fittings Industrial metal LED light fittings Emergency LED light fittings

Linear Luminaire with LED Series EXLUX 6402/2

Cross-beam scanning system to detect slim objects. 100 mm in

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

Evolve LED Garage Light

Downlights Panels Floodlights Lowbay Highbay Streetlights Tubes Induction Linear

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

T8 1200mm LED Tube 18 W FICHA TÉCNICA (1/5)

DETAS -DLEDS Division

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

EDGE Park / R Mounting R recessed

Welcome to this presentation on Driving LEDs Resistors and Linear Drivers, part of OSRAM Opto Semiconductors LED Fundamentals series.

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

2D and 2D Watt-Miser. GE Lighting DATA SHEET. Compact Fluorescent Lamps Non-Integrated 16, 21, 28, 38W 2D Watt-Miser and 55W 2D. Product information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Datasheet. Arrant-Light Oy. 120W DR Series

Guide to Starters Guide to Starters Page 1 of 17

LINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 EN60598 / EN62031 / EN62471.

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Transcription:

www.osram.com OSRAM SubstiTUBE Trio 2 Datasheet Innovative LED-lamp, easy and safe to use in CCG installations as direct retrofit. Energy saving potential of up to 60% by replacing T8 fluorescent tubes. Instant 100% light without flickering. No mercury. Applicable in supermarket, warehouses, cold storage, supply rooms, corridors, industry, stairways, garages, indirect illumination etc; for applications with long operating hours. Technical Data Product Color Color Temp. Lum. Flux [lm] Voltage [V] / Frequency [Hz] Power [W] Full width half maximum beam angle [ ] ST8-HT2-075-865 Cool Daylight 6500 K 750 ST8-HT2-075-840 Cool White 4000 K 750 8W ST8-HT2-065-830 Warm White 3000 K 650 ST8-HT4-140-865 Cool Daylight 6500 K 1400 ST8-HT4-140-840 Cool White 4000 K 1400 15W ST8-HT4-125-830 Warm White 3000 K 1250 ST8-HT4-170-865 Cool Daylight 6500 K 1700 200-240 V 50 / 60 Hz *(Rated 230V) 140 ST8-HT4-170-840 Cool White 4000 K 1700 20W ST8-HT4-150-830 Warm White 3000 K 1500 ST8-HT4-220-865 Cool Daylight 6500 K 2200 ST8-HT4-220-840 Cool White 4000 K 2200 23W ST8-HT4-200-830 Warm White 3000 K 2000 All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. * Rated voltage Technical Features Page 1 of 6 (Rev. 1) Oct 2013

OSRAM Linear LED lamp in T8 shape with G13 socket Suitable for operation with magnetic ballast Direct retrofit for CCG luminaires; replacement of lamp and including starter and no rewiring is necessary Polycarbonate cover Full integrated electronic driver complies to relevant standards CRI 80-85 Complies with draft of relevant safety standards Power factor > 0.9 More than 30,000 hours lifetime Overpower, overheat, short and open circuit protected High color and light homogeneity RoHS-conformity, no mercury Not for operation with ECG, not suitable for dimming Minimum / Maximum ratings Ambient temperature Ta Storage temperature Ts Operating temperature Tc 2ft 4ft -10 45 C -20... 65 C -20... 75 C Mechanical & Electrical Specifications Models A B C Net weight ST8-HT2 588 mm 602 mm 28mm 118g ST8-HT4 1198 mm 1212 mm 28mm 205g Standards (According to IEC 60081) Optics: Diffused PC Cover Mounting: G13 Protection Class: IP20 Tensile Strength (N/mm²), Compressive strength (N/mm²) & Impact strength (kj/m²esp. kn/m): IEC 61195 and IEC 60061 ESD Protection: IEC 61547 Dimming Function: N.A. Rated Voltage: 220-240V~, 50/60Hz Power Factor: >0.9 @ direct mains, >0.9 @ CCG non compensated Safety Protection: Short circuit protection / open loop protection Photo-biological Safety: IEC 62471 Page 2 of 6 (Rev. 1) Oct 2013

OSRAM Flammability: Glow wire test (650 C) Insulation class: IEC 61347-2-13 Safety Requirements IEC 60598-1 + IEC 61347-2-13 + IEC 61195 + IEC 60061 + IEC 62776 proposal Environment: RoHS EMC / radio disturbance characteristics: EN 55015 (CISPR 15) EMC / immunity: IEC 61547 (IEC 61000-3-2 and -3-3) Page 3 of 6 (Rev. 1) Oct 2013

OSRAM Installation Instructions Please ensure that the voltage supply is disconnected. Carefully remove the fluorescent tube and conventional starter according to the lamp holder type. Insert SubstiTUBE Trio and SubstiTUBE Starter properly. Below an example for typical lamp holder types is described Turn the conventional lamp 90 degrees and take it out of the socket. Remove the conventional starter by turning it. Insert and latch the SubstiTUBE Start into starter socket. Insert SubstiTUBE Trio into socket and locate into position by turning 90. Check light emission direction Safety and Application notes The SubstiTUBE Trio must be handled with care, and do not operate the product that in a damaged condition. When operating with CCG (magnetic ballast), SubstiTUBE Starter has to be inserted to replace the conventional fluorescent lamp starter as well. If the conventional starter is not replaced, the SubstiTUBE Trio will start blinking and be damaged! Do not use SubstiTUBE Trio in luminaires which do not have any conventional starter or whereby the conventional starter cannot be replaced. Not suitable for luminaires with serial lamp connection i.e. more than one tube at one magnetic ballast. The SubstiTUBE Trio Trio lamp emits light at limited angle, unlike conventional fluorescent tube in 360 omni direction. Due to the light distribution characteristic of the SubstiTUBE Trio, the resulting luminaires light characteristic is likely to change. It is not guaranteed that e.g. standards for lighting at working places will be complied with after replacement. A photometric check of the installation is highly recommended. The effective energy savings depend on the efficiency of the luminaires setup to be replaced and should be considered individually case by case basis. Particularly magnetic ballast losses are reduced to ohmic losses and are typically only about 1 W. The SubstiTUBE Trio is protected according to IP20. Applications with external risk of moisture and dust can be served with an adequately protected luminaires. SubstiTUBE Trio may also be driven directly on line voltage. In order to grant a safe operation mode please refer to the application note for installation information. Photobiological Safety of Lamps and Lamp Systems according to IEC 62471 Risk Group: Exempt Page 4 of 6 (Rev. 1) Oct 2013

OSRAM The LED tube isn t suitable to be used in emergency luminaries designed for doublecapped fluorescent lamp(s). LED tube Non-dimmable LED tube suitable for 50Hz or 60Hz operation LED tube should be used in dry conditions or in a luminaries that provides protection. The product includes two parts: a LED tube and a LED starter. Increased weight may reduce the mechanical stability of certain luminaries and lamp holders and may impair contact making and lamp retention. Suitable to be used in combination with magnetic ballast only. Only to be used with provided SubstiTUBE LED starter. This lamp is designed for general lighting service (excluding e.g. explosive atmospheres). Page 5 of 6 (Rev. 1) Oct 2013

OSRAM Ordering guide Product name Light color IC EAN 10 (Single Unit) S-Unit ST8-HT2-075-865 Cool Daylight/ 6500K AA707200055 4052899137318 ST8-HT2-075-840 Cool White/ 4000K AA707210055 4052899137295 ST8-HT2-065-830 Warm White/ 3000K AA707220055 4052899137271 ST8-HT4-140-865 Cool Daylight/ 6500K AA685700055 4052899137370 ST8-HT4-140-840 Cool White/ 4000K AA685710055 4052899137356 ST8-HT4-150-830 Warm White/ 3000K AA685720055 4052899137332 ST8-HT4-170-865 Cool Daylight/ 6500K AA707260055 4052899137431 25 x 1 ST8-HT4-170-840 Cool White/ 4000K AA707270055 4052899137417 ST8-HT4-150-830 Warm White/ 3000K AA707280055 4052899137394 ST8-HT4-220-865 Cool Daylight/ 6500K AA707290055 4052899172425 ST8-HT4-220-840 Cool White/ 4000K AA707300055 4052899172401 ST8-HT4-200-830 Warm White/ 3000K AA707310055 4052899172388 SALES & TECHNICAL SUPPORT OSRAM Asia Pacific 16 th Floor, China Resource Building, Sales and technical support is given by the 26 Harbour Road, Wanchai, Hong Kong local OSRAM subsidiaries. Complete +852 3652 5678 subsidiaries listing is available at OSRAM www.osram.com homepage. Page 6 of 6 (Rev. 1) Oct 2013