Standard Operating Procedures Clinical and Translational Research Center

Similar documents
MEASURING VITAL SIGNS TRAINING CHECKLIST

Manual Blood Pressure Measurement

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE

How to measure blood pressure using digital monitors

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

Health Technician skills checklist Health Services Department Lincoln Public Schools TEMPERATURE

Vital and Diagnostic Signs

Upper Arm Blood Pressure Monitor SC Instructions for use

Plank 1 Tool: Hypertension Medical Assistant Training (Providence Medical Group)

Project 4.2.1: Heart Rate

Blood Pressure Assessment Program Screening Guidelines

MEASURING AND RECORDING BLOOD PRESSURE

Vasc Health Risk Manag. 2011; 7: Published online 2011 November 30. doi: /VHRM.S27193 PMCID: PMC

Vtial sign #1: PULSE. Vital Signs: Assessment and Interpretation. Factors that influence pulse rate: Importance of Vital Signs

PTA 210 PTA Technique. Vital Signs

Blood pressure measurement devices. December 2013

MEDICAL ASSISTING CLINICAL

Critical Care Therapy and Respiratory Care Section

Body cavities. Body Planes

INSTRUCTION MANUAL. 7 series Blood Pressure Monitor with ComFit TM Cuff. Model BP760 ESPAÑOL ENGLISH

UNIT 1 Admitting patients

Indirect Blood Pressure Measurement

April 3, Dear Autumn Liu,

INSTRUCTION MANUAL. Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff. Model HEM-775

Measurement of Blood Pressure

Automatic Wrist Blood Pressure Monitor with

INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785CAN FRANÇAIS ENGLISH

INSTRUCTION MANUAL. 10 series Blood Pressure Monitor with ComFit TM Cuff. Model BP785 ESPAÑOL ENGLISH

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

huidige en toekomstige hemodynamische bewaking

Procedure for Inotrope Administration in the home

MEASURING AND RECORDING BLOOD PRESSURE

Reading Assignment: Tasks for the Veterinary Assistant, pages , Appendix L, O and P

Blood Pressure Guidelines and Screening Techniques

INSTRUCTION MANUAL HEM-6052

Circulation Stations

CHEM 1406 BSA/BMI Measurement Laboratory (revised 01/03//06) BSA, Body Surface Area

IQvitals PC. OPERATION MANUAL Version 8.6.1

a Centre de Médecine Cardiovasculaire, Paris, France and b Lebanese Received 7 June 2009 Revised 6 September 2009 Accepted 17 September 2009

OEM MAXNIBP Frequently Asked Questions

Anna M. Lamb DO FACOFP OMED 2010 San Francisco

Welch Allyn 1500 Patient Monitor Train the Trainer

Measuring Your Blood Pressure at Home. A Review of the Research for Adults

Making Simulation Easier. SimPad System. Laerdal Simulation Solutions. laerdal.com. laerdal.com

Section Two: Arterial Pressure Monitoring

Device Equivalence Evaluation Form

Psychology equipment

Device Equivalence Evaluation Form

Clinic Assistant Training: Level 1

DINAMAP PRO Series V2 Monitor. Operation Manual

Obstetrical Emergencies

INVESTIGATING HEART RATE AND BLOOD PRESSURE

Affordable ABPM and strictly guideline-based SBPM for accurate out-of-office blood pressure measurement.

How to Submit a School Epinephrine Report

Electrocardiogram and Heart Sounds

A Complete Range of Ankle Brachial Index (ABI) Systems for Peripheral Arterial Disease (P.A.D.) Detection

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning.

MED-AFEs Design Reference Manual

American Journal of Pharmaceutical Education 2007; 71 (1) Article 01.

DISCHARGE CRITERIA FOR PHASE I & II- POST ANESTHESIA CARE

ASSISTIVE MEDICATION ADMINISTRATION PERSONNEL EXAM (AMAP)

The information in this document is subject to change without notice.

Cardiac Catheterization

Responses to Static (Isometric) Exercise

Device Equivalence Evaluation Form

Monitoring Blood Pressure

P R E S S U R E P O I N T S S E R I E S : Measuring your blood pressure at home

An Overview of Transradial Patient Set-up. Susan R. Cooney RN,BSN,CCRN Durham VAMC Cardiac Catheterization Lab Duke University School of Nursing

Emergency Scenario. Chest Pain

INSTRUCTION MANUAL. 10 series Plus Blood Pressure Monitor with ComFit TM Cuff. Model BP791IT ESPAÑOL ENGLISH

Firefighter Rehabilitation. by Sandra Stoeckel RN,CEN,AEMT-P, Firefighter

THE ROYAL FREE HOSPITAL NHS TRUST MATERNITY CLINICAL GUIDELINES. MEOWS Guidance in Maternity

Human ECG Laboratory Experiment By

FIREGROUND REHAB PROCEDURES

Digital Blood Pressure Monitor. Model UA-767

STANDARD OPERATING GUIDELINE

All About Your Peripherally Inserted Central Catheter (PICC)

Pressure Sensor Based Estimation of Pulse Transit Time

Peripherally Inserted Central Catheter (PICC) for Outpatient

Early Warning Scores (EWS) Clinical Sessions 2011 By Bhavin Doshi

Exercise, the Electrocardiogram, and Peripheral Circulation

HAND-ARM VIBRATION SYNDROME ASSESSMENT TESTS

Activity: Build Your Own Lung

Take a few minutes for yourself and incorporate some Office Yoga into your daily routine.

HIGH BLOOD PRESSURE AND YOUR KIDNEYS

Hemodialysis Access: What You Need to Know

DEVELOPMENT OF EMBEDDED WEB SERVER FOR MEDICAL FIELD

Common Causes of Fluctuating Blood Pressure. When Fluctuating Blood Pressure Readings are Normal

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E

VITALMONITOR SOFTWARE FOR PATIENT MONITORING

Prepared by: Westat, Inc Research Boulevard Rockville, MD September 1989

Blood Pressure Accessories and Supplies

High Blood Pressure and Your Kidneys

Intro Who should read this document 2 Key Messages 2 Background 2

WRIST BLOOD PRESSURE MONITOR

LUNG VOLUMES AND CAPACITIES

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.

ThermoScan Instant Thermometer IRT 1020 Type 6005 Home Model

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

Transcription:

Standard Operating Procedures Clinical and Translational Research Center Title: Vital Signs Approved By: Number of Pages: 1 of 5 Effective Date: Revised Date: March 19, 2012 Purpose: Obtaining accurate vital sign measurements is an essential part of the research procedure. The standardization of blood pressure technique is necessary to minimize variability due to known exogenous factors and to reduce imprecision and biases in measurement. Procedure: IRB approved protocols outline the schedule for performing vital sign measurements and results are documented in the participant s chart. Identify the correct participant by asking the participant to state their name and date of birth and compare to information documented in chart prior to initiating any procedures. Normal Vital Sign Parameters: Oral temperature range: 97.6 F 99.6 F Adult pulse range: 60-100 beats/minute Systolic blood pressure range: 90-140 mmhg Diastolic blood pressure range: 60-90 mmhg O2 Saturation: 95% - 100% Page 1

A. Oral Temperature 1. For oral temperature measurement, use an oral probe. 2. Make sure the temperature probe is connected to the vital check machine if applicable, inserting the thermometer probe completely and firmly into a plastic probe cover to ensure a secure fit. 3. The probe is placed under the participant s tongue in the sublingual pocket where the richest blood supply and heat are located. 4. Record the displayed temperature 5. Normal temperature range for an adult: 97.6ºF 99.6 ºF 6. Dispose of the probe/probe cover into a waste container. B. Rectal Temperature 1. For rectal temperature measurement, use a rectal probe. 2. Have the participant lie on their side. Provide complete privacy. 3. Attach a probe cover to the probe as described in step 3 above. 4. Gently insert the probe about one-half of an inch above the sphincter muscle (the use of lubricant is optional). 5. Record the displayed temperature 6. Normal temperature range for an adult: 97.6ºF 99.6 ºF 7. Dispose of the probe/probe cover into a waste container. C. Heart Rate or Pulse 1. When using a vital check machine, the heart rate will be displayed with the B/P reading. 2. To check the heart rate manually, place the index finger and middle finger lightly on the participant s radial pulse and feel the pulsation or beat. 3. Count the beats for a full 30 seconds/or per protocol and record in the chart as beats per minute (bpm). 4. Normal range is 60 100 bpm

D. Respirations 1. Observe the participant s breathing pattern. 2. Count the number of times the participant inhales (inspiration and expiration is 1 full count) for a full 30 seconds. 3. Record the number of breaths per minute in the chart. E. Pulse Oximetery 1. Make sure the pulse oximetery sensor cable is connected to the monitor. 2. Place the sensor on the participant's finger with the LEDs positioned on the nail side. 3. A plethysmographic waveform will appear when the sensor is properly positioned. 4. Record the reading, and remove the sensor from the participant's finger unless otherwise ordered. 5. Refer to manufacturer s manual as devices may differ one from to another. F. Automated Blood Pressure 1. Select the appropriate B/P cuff according to participant's arm circumference according to reference range. 2. Secure the cuff around the participant's right upper arm (or arm designated by the protocol). 3. Check for kinks or other obstructions in the hose extending from the cuff. 4. For optimal accuracy, the participant's arm should be at the level of the heart. 5. Press the "START/STAT/STOP" button on the vital check machine to initiate a B/P reading. 6. Record the B/P and remove the cuff from the patient's arm. 7. Normal blood pressure range for an adult: 90/60 mmhg - 140/90 mmhg 8. Refer to manufacturer s manual as devices may differ one from to another.

G. Aneroid Blood Pressure 1. Selected cuff size appropriate for the participant s arm circumference is applied according to reference range. 2. The cuff is wrapped around the arm with the artery index marker located over the brachial artery and with the lower edge of the cuff 2.5 cm above the bend in the elbow. 3. Cuff is inflated rapidly to a level 30 mmhg above palpatory systolic pressure. 4. Palpatory systolic pressure is obtained by placing the index finger and middle finger lightly on the participant s radial pulse and feeling for the cessation of the pulsation while inflating the cuff. 5. Deflation is at a rate of 2 mmhg per second. As the pressure falls, the systolic pressure and diastolic pressure are recorded. Note: Some studies will call for a more stringent assessment for measuring blood pressure and will be outlined in their approved IRB Protocol Alerts /Referrals Alert levels requiring immediate notification of PI/Co-I or his designee to evaluate participant and discharge from CTRC: Systolic BP >180mmHg Diastolic BP >110 mmhg Emergency Room Referral for symptomatic participants with alert level BP includes but not limited to the following: - Headache - Chest Pain -Shortness of Breath -Visual Disturbances

Appendices: Appendix A CTRC Protocol Order Worksheet Appendix B - CTRC Progress Note