FX07 Field Controller

FX07 Field Controller

FX16 Master Controller

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Model: DC-A2IO Advanced HVAC Controller

T7560A,B,C Digital Wall Module

T5000 T000 LCD Digital Fan Coil Thermostat

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

IntesisBox KNX - LON

HMI display Installation Guide

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Rack mounted telephone- and leased line modem for industrial applications

Duct Humidity Transmitter

DCS Series 1 kw, 1.2 kw, & 3 kw

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

IntesisBox KNX Modbus RTU master

Telephone- and leased line modem for industrial applications TD-36

Inwall Room Temperature Unit

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

TAC I/NETTM MR-AHU-HP. Application Specific Controller

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Heating Controller. Building Technologies HVAC Products

How To Use A Ds340 (Dsp)

Frequency Converter Fv

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

EBS852 (Contrac) Power Electronic Unit

Optimize your simple machines... Modicon M218 Selection Guide

IntesisBox KNX Modbus TCP master

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

38 Series - Relay interface modules A

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

EFC Frequency converters

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

IntesisBox KNX LG Air Conditioning

Unidirectional Transmitter/ Receiver Units Introduction

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

38 Series - Relay interface modules A

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

CONFIGURABLE SAFETY RELAYS

TAC I/NETTM. Process Control Unit

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Material test chamber with mechanical convection

KNX Panasonic Air Conditioners

PD 100A. Printing data system

The multi-functional integrator Supercal 531

Sterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Technical Data Sheet. 3DLevelScanner

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Quick Connect. quick - simple - efficient.

3DLevelScanner II TECHNICAL DATA SHEET

Vitosoft 200 Vitodata 300 Vitocom 300 Vitocom 100

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Smile. The All-In-One Heating Controller

CONFIGURABLE SAFETY RELAYS

DUCT SMOKE DETECTOR D4120

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Power Meter Series 700

Temperature & Humidity SMS Alert Controller

Controller board and power supply for vivimat III systems

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ACS-30-EU-EMDR-10-MOD

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Ordering Part Numbers:

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Application/Connection Examples

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

O C M III. Open Channel Flow Monitor

Remote Monitoring and REC 501 Control Unit Product Guide

HCE80/HCC80/HCE80R/HCC80R

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

User manual Rev 1.3 Contents

40.3. Control Relays and Timers

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Flow Monitoring System

Panel Meters and Controllers Modular Panel Meter Type EDM 35

T7079A,B Solid State Remote Temperature Controllers

Electronic, Digital and Mechanical Vibration Switches

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Transcription:

FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating, Air Conditioning, and Refrigeration (HVACR) applications. The controller has 17 physical inputs and outputs and supports a wide range of temperature sensors and actuating devices. Active sensors for the measurement of humidity, pressure, and other variables are also supported. The FX07 also includes an onboard Real-Time Clock to support the start-stop scheduling of equipment and realtime based control sequences. The FX07 has an optional attractive Liquid Crystal Display (LCD) with a set of graphic status icons used in the most common HVACR applications. The controller also supports a remote panel or wall mounted Medium User Interface (MUI). Communication cards are available to enable the controller to be integrated into an N2 Open or LONWORKS network of a building automation system. For stand-alone applications, the FX07 Field Controller also features communications services to transmit event notification messages via Short Messaging Service (SMS). Using the FX Tools software package, the FX07 terminal unit controller is fully configurable for a wide range of commercial HVACR applications. These applications include small refrigeration compressors, close control units, roof-top air handlers, fan coil units, unit ventilators, and chilled or heating ceiling beam installations. Features Freely Programmable Controller Network Communication Card Options Remote Communication Services Optional Integral Liquid Crystal Display User Interface with Four Control Buttons Analog Outputs with Pulse Width Modulated (PWM) Option Models with Various Output Configurations of Solid State Triacs and Line Voltage Relays FX07 Field Controller Without Display Model Dimensions in mm (inches) 24 VAC/VDC Models - Selection Table Without Display With Integral Display 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), no communication card LP-FX07D00-000C LP-FX07D50-000C 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), N2 Open card LP-FX07D01-000C LP-FX07D51-000C 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), LONWORKS card LP-FX07D02-000C LP-FX07D52-000C 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), RS-232C card LP-FX07D03-000C LP-FX07D53-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), no communication card LP-FX07D20-000C LP-FX07D70-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), N2 Open card LP-FX07D21-000C LP-FX07D71-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), LONWORKS card LP-FX07D22-000C LP-FX07D72-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), RS-232C card LP-FX07D23-000C LP-FX07D73-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs), no comm. card LP-FX07D30-000C LP-FX07D80-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs), N2 Open card LP-FX07D31-000C LP-FX07D81-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs), LONWORKS card LP-FX07D32-000C LP-FX07D82-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs) RS-232C card LP-FX07D33-000C LP-FX07D83-000C - Page 6 -

FX07 Field Controller (2/4) 90-240 VAC/VDC Models - Selection Table Without Display With Integral Display 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), no communication card LP-FX07A00-000C LP-FX07A50-000C 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), N2 Open card LP-FX07A01-000C LP-FX07A51-000C 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), LONWORKS card LP-FX07A02-000C LP-FX07A52-000C 4 AIs, 5 DIs, 2 AOs (0-10 V or PWM), 6 DOs (Relays), RS-232C card LP-FX07A03-000C LP-FX07A53-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), no communication card LP-FX07A20-000C LP-FX07A70-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), N2 Open card LP-FX07A21-000C LP-FX07A71-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), LONWORKS card LP-FX07A22-000C LP-FX07A72-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (4 Relays, 2 Triacs), RS-232C card LP-FX07A23-000C LP-FX07A73-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs), no comm. card LP-FX07A30-000C LP-FX07A80-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs), N2 Open card LP-FX07A31-000C LP-FX07A81-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs), LONWORKS card LP-FX07A32-000C LP-FX07A82-000C 4 AIs, 5 DIs, 2 AOs (0-10 V), 6 DOs (3 Interlocked Relays, 1 Free Relay, 2 Triacs) RS-232C card LP-FX07A33-000C LP-FX07A83-000C Communication Card - Selection Table N2 Open Communication Card LONWORKS Communication Card RS-232 Communication Card LP-NET071-000C LP-NET072-000C LP-NET073-000C User Interfaces - Selection Table Remote Medium User Interface (MUI Version 3) - Panel Mount (non-isolated model) Remote Medium User Interface (MUI Version 3) - Wall Mount (isolated model) Link cable for the connection of the FX07 to the Panel Mount MUI display - 3 m (9.8 ft) LP-DIS60P20-0C LP-DIS60P21-0C LP-KIT007-000C Software - Selection Table FX Tools Pro CD-Rom (FX Builder, FX Builder Express, FX CommPro N2, FX CommPro LON) New User FX Tools Pro CD-Rom (FX Builder, FX Builder Express, FX CommPro N2, FX CommPro LON) Upgrade LP-FXTPRO-0 LP-FXTPRO-6 Accessories - Selection Table FX Programming Key Power Supply Adapter for Programming Key: 230 VAC/12 VDC Null modem cable for computer connection, 3 m (9.8 ft) Null modem cable for computer connection, 15 m (49.2 ft) LP-KIT100-000C DT-9100-8901 LP-KIT007-013C LP-KIT007-014C - Page 7 -

FX07 Field Controller (3/4) Room Command Modules - Selection Table Room Sensor Modules 80 mm x 80 mm (3.15 x 3.15 in.), C (TM Series without Display) Room Sensor Module, temperature sensor only Room Sensor Module, occupancy button and LED Room Sensor Module, 12-28 C setpoint dial, occupancy button and LED Room Sensor Module, 12-28 C setpoint dial, occupancy button and LED, fan speed override Room Sensor Module, +/- setpoint dial, occupancy button and LED Room Sensor Module, +/- setpoint dial, occupancy button and LED, fan speed override Room Sensor Module, 12-28 C setpoint dial Room Sensor Module, +/- setpoint dial TM-2140-0000 TM-2150-0000 TM-2160-0000 TM-2160-0002 TM-2160-0005 TM-2160-0007 TM-2190-0000 TM-2190-0005 Room Command Modules - Selection Table Network Room Modules with Serial Bus Connection to FX07 80 mm x 80 mm (3.15 x 3.15 in.), C Network Room Module, temperature sensor only, no display, no setpoint dial Network Room Module with LCD display, temperature sensor, setpoint dial, occupancy function LP-NRM001-000C LP-NRM002-000C Digital (Binary) Outputs for Specific Models Model Channel Type Remark/Application FX07D0x-xxx FX07D5x-xxx FX07A0x-xxx FX07A5x-xxx FX07D2x-xxx FX07D3x-xxx FX07D7x-xxx FX07D8x-xxx FX07A2x-xxx FX07A3x-xxx FX07A7x-xxx FX07A8x-xxx FX07D2x-xxx FX07D3x-xxx FX07D7x-xxx FX07D8x-xxx FX07A2x-xxx FX07A3x-xxx FX07A7x-xxx FX07A8x-xxx DO1, DO2, DO3 DO4, DO5, DO6 SPST 8(3)A, SPST 3(1)A, Heavy duty relays that can be used to switch electric heater up to 2 KW at 230 VAC. (Europe only) Each relay contact is independent with its own common terminal. Each relay contact is independent with its own common terminal. DO1, DO2 0.5A/24 VAC Triacs Low voltage 3-point incremental actuators and thermal actuators DO1, DO2 DO3 DO4 DO6 0.5A / 250 VAC Triacs SPST 8(3)A, SPST 3(1)A, Line voltage 3-point incremental actuators and thermal actuators. Can also be used to switch 24 VAC low voltage devices. Heavy duty relay that can be used to switch electric heater up to 2 KW at 230 VAC (Europe only). On the FX07x2x-xxx and FX07x7-xxx models, each relay contact is independent with its own common terminal. On the FX07x3x-xxx and FX07x8-xxx model, DO4, DO5, DO6 Relays are physically interlocked such that only one output can be closed at one time. Application: 3-speed fan motors. - Page 8 -

FX07 Field Controller (4/4) Technical Specifications Product Codes Power Supply Requirements Power Consumption Protection Class Ambient Operating Conditions LP-FX07xxx-xxx LP-FX07Dxx-xxx: 24 VAC/DC ±15%, 50/60 Hz - SELV (Europe) - Class 2 North America LP-FX07Axx-xxx: 90 to 240 VAC, 50/60 Hz LP-FX07Dxx-xxx: 9 VA maximum LP-FX07Axx-xxx: 17 VA maximum IP20 CEI/EN60529-40 C to 50 C (-40 to 122 F), 10 to 95% RH (non condensing) Note that the integral user interface does not operate below -20 C (-4 F) Ambient Storage Conditions -40 C to +70 C (-40 to 158 F), 10 to 95% RH (non condensing) Dimensions (H x W x D) 145 mm (5.7 in.) including terminals x 108 mm (4.26 in.) x 49 mm (1.93 in.) - 62 mm (2.45 in.) with display Weight (with package) 0.60 kg (1.32 lb) Integral LCD Display Resolution -999 to 999 or 99.9 to 99.9 Digital Inputs Voltage free contacts Transition counter function at 50 Hz (minimum 10 ms ON and minimum 10 ms OFF) Analog Inputs and Accuracy at 20 C (68 F) Ambient Not isolated. Software configurable. Sensor Type Range Accuracy (sensor error not included) A99-40 to 100 C (-40 to 212 F) ±0.5 C (±1 F) NTC K10-20 to 70 C (-4 to 158 F) ±0.5 C (±1 F) PT1000 Extended -40 to 160 C (-40 to 320 F) ±0.5 C (±1 F) Ni1000-40 to 120 C (-40 to 248 F) ±0.5 C (±1 F) Active 0...10 V 0..10 VDC ±0.05 VDC Active Ratio-metric 0.5 to 4.5 VDC ±0.05 VDC Analog Outputs 0...10 VDC, 3 ma, not isolated for actuating and control devices. Pulse Width Modulation (PWM) Signal at 100 Hz cycle frequency Relay Outputs Dielectric test voltage on open relay contact: 1,000 VAC RMS Maximum relay switching rate at nominal load: 6 operations / min Average relay contact life: 30,000 operations at maximum load. Connection Terminals for outputs Screw terminals for max 2 x 1.5 mm 2 (AWG16) wires, included in the package. and Power Supply Connection Terminals for inputs and LON/N2 Open Bus Screw terminals for max. 1 x 1.5 mm 2 (AWG16) wires or 2 x Belden cable, 2-core twisted pair with shield 0.8 mm (AWG20), included in the package CE Compliance 89/336 EEC directive: EN 61000-6-3, EN 61000-6-1 73/23 EEC directive: EN 60730 UL Compliance UL873, UL916 - Page 9 -