Heat Pump Pool and Spa Heater QUICK START GUIDE

Similar documents
Heat Pump. Quick Start Guide Models: 035, 055, 075, 090, 115, 110, 120, 121, 135, 155, 156, & 175

SWIMMING POOL HEAT PUMP

USER S MANUAL HSC-24A

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

CARING FOR YOUR WATER HEATER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner

Split Type Room Air Conditioner. KSWM units

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Instruction manual for Firstline FCS12000CH

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Operating Instructions Split System Air Conditioner

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Operating Instructions Air Conditioner

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Use and Care Manual. Model CPA12KH AIR CONDITIONER

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Overheating limit control

OPTIONAL SLENDER REMOTE CONTROL

SWIMMING POOL HEAT PUMP Owners Manual

Tankless Water Heater

SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE

Room Air Conditioners

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

, User s Manual

United Technologies USER'S MANUAL. Split Type Room Air Conditioner

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Operating Instructions Air Conditioner

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual

WINDOW ROOM AIR CONDITIONER

Dealer Sales & Service Guide

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

AIR CONDITIONER INSTALLATION MANUAL

OTF Oil Fired Pool Heater

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

SL280UHV SERIES GAS FURNACE WARNING

Oil and Coolant Circulating Heating System. Model - OCSM

INFRARED QUARTZ WALL HEATER

PANASONIC TROUBLE SHOOTING GUIDE

Ceiling Mount Air Handler Manual

Taurus Series YORK Window Air Conditioners

14. Troubleshooting Guide

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

HEATER, AIR CONDITIONING AND VENTILATION

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Quest 105, Dry155, and 205 Dual

AIR-CONDITIONER SPLIT TYPE

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

R410A SPLIT SERIES DC INVERTER

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

ALL IN ONE. Heat Pump Water Heater

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

AROS SMART WINDOW AIR CONDITIONER

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Panel Mounted Air Conditioners by Dantherm, Inc.

Trouble Shooting. Pump

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

Installation and maintenance instructions. Danfoss Vent

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

COMPRESSED AIR DRYER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

AIR CONDITIONER (SPLIT TYPE)

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

TIG INVERTER INSTRUCTION MANUAL

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

G & F Manufacturing Swimming Pool Heat Pump

Split Air Conditioner

DUCT TYPE AIR CONDITIONER

INDOOR UNIT/OUTDOOR UNIT

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

AIR CONDITIONER Duct Type OPERATING MANUAL

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

AROS SMART WINDOW AIR CONDITIONER

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

ClearView 100. Instruction Manual

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Transcription:

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/orproperty damage! Retain instructions for future reference. Heat Pump Pool and Spa Heater QUICK START GUIDE Model ECO500 50,000 BTU Heat & Cool 1

SECTION 1 - GENERAL INFORMATION CONTACTING www.ecoaquapro.com Phone (877) 278-2797 8:00 a.m. to 5:00 p.m. Eastern time, Monday through Friday Fax (888) 610-3839 SAFETY For personal safety, and to avoid damage to equipment, follow all safety instructions displayed in this guide. Repair and service of your heat pump must be performed by qualified service personnel. Failure to properly install, operate, maintain, or repair the heat pump will void factory warranty. Please note "WARNING" signals relate to personal safety, while "CAUTION signals promote avoiding damage to equipment. Follow all National Electric Codes (NEC) unless State or Local guidelines supersede. When installing and using your heat pump, basic safety precautions must always be followed WARNING - Failure to heed the following may result in injury or death. Heat pumps contain no owner-repairable components. Electrical Installation should be by Licensed Electrician only. Service to the refrigerant circuit must be performed only by qualified HVAC Technicians. Heat pumps utilize high voltage and rotating equipment. Use caution when servicing. Heater contains refrigerant under pressure. Recover refrigerant before opening system. Prolonged immersion in water warmer than normal body temperature can cause fatal Hyperthermia. The use of alcohol, drugs, or medication can greatly increase the risk of fatal Hyperthermia. Persons having an adverse medical history, or pregnant women, should consult a physician before using a hot tub or spa. In addition, children and the extreme elderly should be supervised by a responsible adult. CAUTION - Failure to heed the following may result in equipment damage. Improper water chemistry can cause damage to pump, filter, pool shell, etc. To avoid equipment damage, maintain Pool/Spa water per standards detailed later in this manual. Water flow exceeding max flow requires a bypass. Damage due to excessive water flow will void warranty. SAVE THESE INSTRUCTIONS WINTERIZING In areas where freezing conditions are a rare occurrence, allow the filtration system to run continuously throughout the freeze period. Typically, during light freeze conditions, circulating (moving) water will not freeze. In areas where freezing conditions are prevalent and sustained, the heat pump must be winterized as follows: 1) Disconnect all electrical power to the heater; turn off circulating pump. 2) At the two (2) connection unions, disconnect the plumbing to the heater (removal is counter-clockwise). 2

3) If your unit has an external drain plug, remove plug. This plug would be located at lower, front corner of heater (position may vary between models). Allow water to drain out of the condenser. Replace the winterizing plug by threading the plug in clockwise until just snug, then apply an additional 1/8 turn. 4) If no drain plug is found, unit is self-draining from unions. Check online manuals for appropriate winterizing procedures on heat pumps older than 2005. 5) To prevent insects and vermin from entering the plumbing during the winterized period, partially reconnect the two (2) plumbing connection unions: couple each union one or two threads; this will permit condensation to drain, but will prevent most insects and animals from entering the plumbing circuit. START UP To ready a winterized heat pump for use, simply retighten plumbing connection unions. Hand-tight is generally sufficient. Warning A. DO NOT use this unit for any other purpose than to regulate swimming pool water temperature. Utilization for any other application will void warranty. B. The inlet & outlet connection joint can not support any other piping system s weight. C. Make sure outlet air does not hurt any person, animal & plant. D. Please make sure to switch off the power before any examination and repair. Precautions A. The unit must be installed & maintained by professional technician, the Power layout must comply with local concerned regulation. Please read the manual carefully. B. Set proper temperature in order to get desired water temperature. C. Please do not stack substances that can block air flow near inlet or outlet area. D. The unit will automatically start up upon power available although power stop during operation. E. If the machine is stopped for a long time or in winter season please cut off the power supply and drain water clear of the machine by opening the tap of inlet pipe. F. Do not put your hand or pole into air outlet of evaporator, forbid to disassemble the working fan. G. If any abnormal status occurs such as abnormal noise, smell, smoke, electricity leakage, please switch off power immediately and contact your local dealer, please do not check the unit by yourself. H. Do not store combustible or flammable material near unit. I. Application 1- Set swimming pool water temp efficiently and economically to provide you comfort and pleasure 2- User may choose the model technical parameter according to professional guide, this series of swimming pool heater has been optimized in factory (refer to technical parameter table). 3

Technical Parameters Model Heating capacity Cooling capacity 50HC 50000 BTU 29000 BTU Voltage 208-240v Frequency/phase 60Hz/1 PH Compressor RLA/LRA Fan motor rating Refrigerant(R410A) Noise 11.6A/60.2A 0.5 A 56.4oz 50 db(a) Dimension 50HC 4

5

Installation Guide 1. Electric Wiring Diagram 6

7

Pool Heat Pump Customer Remote Control System illustration. a. The 5 & 6 terminal are the connectors with switch of customer remote control system. If not operate this remote control system, pls connect terminal 5 & 6 with a wire. b. If switch on 5 & 6 terminal (run customer remote control system), heat pump will operate as instruction on LED of heat pump. LED indicator light up as current heat pump operation status. If switch off 5 & 6 terminal (not run customer remote control system), heat pump will stop. All indicators light out. Run customer remote control system, switch on terminal 5 & 6, heat pump will operate as heat pump LED instruction, switch off terminal 5 & 6, heat pump will stop operation 2. Installation instruction and requirement The swimming pool heater must be installed by a professional. The users are not qualified to install by themselves, otherwise damage may happen to the heater or threat the body safety of the user. A Installation 1-The swimming pool heater should be installed in a place with good ventilation; 2-The frame must be fixed by bolts to concrete foundation or brackets. The concrete foundation must be solid and fastened; the bracket must be strong enough antirust treated. 3-Please don t stack substances that will block air flow near inlet or outlet area, and there is no barrier within 50cm behind the main machine, or the efficiency of the heater will be reduced or even stopped. 4-When the machine is running, there will be condensation water discharged from the bottom, please pay attention to it. Please hold the drainage nozzle (accessory) into the hole and clip it well, and then connect a pipe to drain the condensation water out. B Wiring 1-Connect to appropriate power supply; the voltage should comply with the rated voltage of the products. Earth the machine well. 2-Wiring must be handled by a professional technician according to the circuit diagram. 3-Set leakage protector according to the local code for wiring 4-The layout of power cable and signal cable should be orderly and not affecting each other. C Switch on after finishing all wiring construction and re-checking. 8

Operation Instruction Picture for keys Operation Display a. The display shows Time when the machine is off b. The display shows Temperature of the swimming pool water when the machine is on. Water temperature setting(heating machine has no cooling function) a. Press MODE key can switch HEAT-SPA-COOL circulating mode. b. Available no matter the machine is on or off. Press HEAT or COOL light up. c. Press the key or to set water temperature. The controller indicates flashing temp. Press or to adjust to your desired water temp. d. 5 seconds later, the controller display will back to the normal mode. SPA water temperature setting(for machine with spa function only): a. Available no matter the machine is on or off. Press MODE to SPA light up. b. Press the key or to set water temperature. The controller indicates flashing temp. Press or to adjust to your desired water temp c. 5 seconds later, the controller display will back to the normal mode. Time setting (Military Based Time is USED FYI) a. Available no matter the machine is on or off. b. Press key to set time when the clock on the screen is flashing, press again to set 9

hour. Use or to adjust hour. Before the flashing stops, press to set minute. Use or to adjust. After adjusting press and water temperature will be displayed. 30 seconds later the controller display will be back to the normal mode. Timer on and off a. Press set timer on. When the indicator light is on and the time is flashing, press again to set hour. Use or to adjust. Before the flashing stops, press to set minute. b. Use or to adjust. After adjusting, press and water temperature will been seen. 30 seconds later, the controller display will be back to the normal mode. c. Press to set timer off. When the indicator light is on and the time is flashing, press again to set hour. Use or to adjust before flashing stop, press to set minute. Use or to adjust. After adjusting, press and water temperature will been seen. 30 seconds later, the controller display will be back to the normal mode. Cancel timer on and off Press or to cancel timer on and off. When the number is flashing, press when timer indicator light is off and LED shows water temperature, the timer on and off is canceled. 30 seconds later, the controller display will be back to the normal mode. Testing 1 Inspection before use A Check installation of the whole machine and the pipe connections according to the pipe connecting drawing; B Check the electric wiring according to the electric wiring diagram; and ground the connection. C Make sure that the main machine power switch is off D Check the temperature setting. E Check the air inlet and outlet. 2 Troubleshooting A The user must Start the Pump before the Machine, And Turn off the Heat Pump before the Pump, or the machine will be damaged. B The user should start the pump, check for any leakage of water; and then set suitable temperature in the thermostat, and then switch on power supply. 10

C In order to protect the swimming pool heater, the machine is equipped with a time lag starting function, when starting the heat pump, the blower will run 3 minutes earlier than the compressor. D After the swimming pool heater starts up, check for any abnormal noise from the machine. Precautions Attention A Set proper temperature in order to get comfortable water temperature; to avoid overheating or overcooling. B Please don t stack substances that can block air flow near inlet or outlet area, or the efficiency of the heater will be reduced or even stopped. C Please don t put hands into outlet of the swimming pool heater, and don t remove the screen of the fan at any time. D If there are abnormal conditions such as noise, smell, smoke and electrical leakage, please switch off the machine immediately and contact the local dealer. Don t try to repair it yourself. E Don t use or stock combustible gas or liquid such as thinners, paint and fuel to avoid fire. F In order to optimize the heating effect; please install heat preservation insulation on pipes between swimming pool and the heater. During running period of the swimming pool heater, please use a recommended cover on the swimming pool. G Connecting pipes of the swimming pool and the heater should be 10m, or the heating effect of the heater cannot be ensured. Safety A Please keep the main power supply switch far away from the children. B When a power cut happens during running, and later the power is restored; the heater will start up automatically. So please switch off the power supply when there is a power cut, and reset temp when power is restored. C Please switch off the main power supply in lightning and storm weather to prevent from machine damage that caused by lightning. D If the machine is stopped for a long time please cut off the power supply and drain water clear of the machine by opening the tap of inlet pipe. Maintenance A Cut off power supply of the heater before any examination and repair. B In winter seasons, please drain water clear of the machine, cut off power supply to prevent any machine damage, and cover the machine body with plastic foil to avoid dust. C Please clean this machine with household detergents or clean water, NEVER gasoline, thinners or any similar fuel. 11

D. Check bolts, cables and connections regularly. Trouble shooting for common faults Faulty Reason Solutions Not starting Main power is off Switch off Burnt out fuse Circuit breaker drops out Wait for power to be reinstated Switch on Replace it Switch Circuit Breaker back on Blocked air inlet Clean out the stem There is air outlet Blocked air outlet Clean out the stem but the heating is 3 minutes time lag protection Please wait not satisfactory Temperature set too low Increase temperature setting accordingly If the above mentioned faults cannot be solved, please contact the professional and inform model and detailed faulty condition. Atten: Please don t disassemble and repair the swimming pool heater by yourself, please leave it to the professionals. Failure code EE 1 EE 2 EE 3 EE 4 PP 1 PP 2 PP 3 PP 4 PP 5 PP 6 PP 7 High pressure protection Low pressure protection Low water pressure protection Over current (3 phase machine) Pool ( SPA )heater sensor failure Exhaust sensor failure Coil pipe sensor failure Intake pipe sensor failure Air temp sensor failure Compressor exhaust overload protection When the temperature<+32, auto stop protection not Failure 12