FCC Test report for LED Panel Light Models ZY-P4-36W CDS series

Similar documents
FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

Regulatory requirements - USA

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Radiometrics Guide to FCC & Canada Compliance. for Unintentional Radiators

Electrified Door Hardware Why Planning for FCC Certification is Key to Success in the Door Hardware Industry

RAPPORTO DI PROVA / TEST REPORT

MoCA Adapter MC1001 v2 Installation Guide

ACRS 2.0 User Manual 1

Wireless Travel Mouse with 5-Buttons User Manual

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

Electromagnetic Compatibility Test Report Test results of Floww equipment

9,'(2 #6(3$5$725 8VHU V#0DQXDO

3.5 mm Audio Jack. Manual innoxplore ix B24 A2DP Stereo Bluetooth Audio Adapter Dongle 3.5mm Audio Jack [ix B24] Contents

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

Rocket 640L/644L 6Gb/s SATA Host Adapter Quick Installation Guide

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

RedTitan Print2PC Parallel Port Converter. Quick Installation Guide - US English. Product contents. Introduction. PC System Requirements

WPR400 Wireless Portable Reader

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

PRO 5000 CPE 1D Quick Installation Guide

Model 70A00-1. GSM Cellular Communications Center

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

PROGRAMMER INSTALLATION INSTRUCTIONS

EZCast 5GHz. Rev ! Quick Start Guide. Introduction

USER MANUAL VS92A / VS94A / VS98A

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Pebble. E-Paper Watch for iphone and Android. 1 Button A. 4 Button B. 5 Button C. 2 Display. 6 Button D. 3 Charge Port

DVI to Mini DisplayPort Converter. EXT-DVI-2-MDP User Manual

No. S8351. S8351 External Bluetooth module for mz series transmitter OPERATING INSTRUCTION

Broadband Telecommunications Drop Amplifier

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Declaration of Conformity.

Power Over Ethernet Adapters POE101

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

Rocket Channel SATA 6Gb/s PCI-Express 2.0 x8 HBA

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

Key. ➍ Micro USB Port ➎ Operating System Toggle Keys ➏ Foam Screen Protectors. ➊ On/Off switch ➋ Bluetooth Connect Button (flashes when searching)

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

TD-8610/TD-8610B External ADSL2+ MODEM

FB-500A User s Manual

ST122VGAU. Instruction Manual. VGA Video Switch. 2-Port Automatic VGA Video Switch

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

User Manual CABLE TESTER CT100. Professional 6-in-1 Cable Tester

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

RocketRAID 600 Series 6Gb/s SATA RAID Host Adapters (RocketRAID 620 and RocketRAID 622)

USER GUIDE. Access to the Server is via the following webpage:

How To Replace A 10/100Mbps Switch With A G1005D/G1008D (Mini) And G100D/ G1008D (Mini And Mini) (Mini/Mini) (Micro) (Power) (

Atomic Projection Alarm with Indoor and Outdoor Temperature

WUA Mbps Wireless USB Network Adapter

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

SanDisk Connect Wireless Flash Drive QUICK START GUIDE

ARCHOS (

Pad. Quick Start Guide

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer

Wave/PC Interactive System USB Adapter Kit. Installation Guide

Quick Start Guide. Version: 1.01 Date: 19/03/2010

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

EMC TEST REPORT For. Webcam. Model Number: CAM67U

P-660HN n Wireless ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware Version 1.10 Edition 1, 9/2010. IP Address:

TEST REPORT EN (1997) +A1 (2001)

Wireless Infrared IR Remote Extender ft (100m)

Installer Guide smart connect

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

USB Serial Adapter ICUSB232SM3. Instruction Manual. 1-Port 3ft USB to RS232 DB9 Serial Adapter Cable

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

PCXpocket 440. Professional Digital Audio Card. User s manual. DU IS=A

Bluetooth Stereo Headphone. User Guide. Hive

Usage, Installation, Warranty and Service Information

TL-PS310U Single USB 2.0 Port MFP and Storage Server

3.5 External Hard Drive Enclosure

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Declaration of Conformity.

Creatix g Adapter CTX405 V.1/V.2 User Manual

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

User Guide. Cordless Optical Mouse N2953

BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:

Instruction Guide. 4 Port Laptop-Sized USB 2.0 Mini Hub ST4200MINI. The Professionals Source For Hard-to-Find Computer Parts

Disclaimers. Important Notice

User guide. Miracast Wireless Display IM10

Declaration of Conformity.

reflecta Super 8 Scanner

ExpressCard USB 3.0 Controller Adapter Card

USB Dual Handset Adapter for Nortel 1100-Series IP Phones

Stretch DisplayPort TM

Industrial 1 Port RS232/422/485 to Dual Ethernet Serial Device Server

5.8GHz Audio/Video Sender

56-A11A Plantronics Calisto Headset with Bluetooth USB Adapter. User Guide

Telephone- and leased line modem for industrial applications TD-36

4 Port VGA Video Audio Switch with RS232 control

User s Manual Model KB990W

AXIS 291 1U Video Server Rack Installation Guide

Transcription:

4312774.52 FCC Test report for LED Panel Light Models ZY-P4-36W CDS series Guangzhou, date of issue: 2013-09-24 Author Ryan Liang By order of James Industry Group Co., Ltd at Hong Kong, China Author : Ryan Liang Reviewed : Tim Yan Pages : 20 pages Annex : NIL DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Building A3, No.3 Qiyun Road, Science City, Guangzhou Hi-Tech Industrial Development Zone, Guangzhou, P.R. China Tel +86 20 6661 2000 Fax +86 20 6661 2001 www.dekra-certification.com

- Page 2 of 20-4312774.52 CONTENTS page 1 Conclusion... 3 2 Summary... 4 2.1 Applied standards... 4 2.2 Reference standards... 4 2.3 Overview of results... 4 3 Classification... 5 4 General Information... 6 4.1 Model description... 6 4.2 Product Information... 8 4.3 Customer Information... 8 4.4 Product labeling... 9 4.5 User information... 9 5 Test information... 10 5.1 Test facility... 10 5.2 Measurement procedure... 10 5.3 Test data... 10 5.4 Environmental conditions... 10 6 Conducted emissions... 11 6.1 Measurement procedure... 11 6.2 Measurement equipment... 11 6.3 Measurement data... 12 7 Radiated emissions... 15 7.1 Measurement procedure... 15 7.2 Measurement equipment... 15 7.3 Measurement data... 16 8 Test setup and arrangement... 18 9 Product Internal Photo... 19

- Page 3 of 20-4312774.52 1 CONCLUSION The device under test (DUT) as mentioned in this report complies with the stated requirements of the FCC Part 15, Class B. The tested system is classified as digital device Class B marked for use in a residential environment notwithstanding use in commercial, business and industrial environments. The conclusion and results stated in this test report are based on a non-recurrent examination of sample(s) provided by the applicant. The tests described in this report do not result in the right to use any approval mark as conferred by DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch As far as the tests were based on certain specifications; these are mentioned in the report.

- Page 4 of 20-4312774.52 2 SUMMARY This chapter presents an overview of standards and results. Refer to the next chapters for details of measured test results and applied test levels. 2.1 Applied standards Standard Year Title FCC part 15 2013 Federal Communications Commission (FCC) Radio Frequency Devices 2.2 Reference standards Standard Year Title ANSI C63.4 2009 American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 40 GHz 2.3 Overview of results Emission tests Conducted emission Radiated emission Result PASS PASS

- Page 5 of 20-4312774.52 3 CLASSIFICATION This chapter presents an overview of the applicable classification and procedure. The following procedure has been selected to confirm the compliance of the device under test: Verification procedure: The Device under Test (DUT) is subject to the Verification procedure. The Verification procedure is defined in 47CFR Part 2 section 2.902 and described in section 2.951 through 2.957 of the FCC rules. Base on client s declaration, the following applicable Class has been selected: Class A : The intended user environment of the device under test is limited to industrial environments and classified as a digital device class A. Class B : The intended user environment of the device under tests is in commercial and light-industrial environments and classified as a digital device class B. For the device under test the following measurement clauses are applicable: 47CFR Part 15 Subpart B Unintentional radiators. Section 15.107(b) Conducted emissions Class A Section 15.107(a) Conducted emissions Class B Section 15.109(b) Radiated emissions Class A Section 15.109(a) Radiated emissions Class B

- Page 6 of 20-4312774.52 4 GENERAL INFORMATION 4.1 Model description The apparatus as supplied for the test is LED Panel Light, model ZY-P4-36W CDS is intended for residential use, the products contain electronic control circuitry but without earth connection and no component susceptible to magnetic fields. All models use same LED driver and same construction, the difference is the rating, the difference list as below table 1: Model Rating power Use same driver ZY-P4-36W CDS 36W ZY-P4-36W CNS 36W ZY-P4-30W CDS 30W ZY-P4-30W CNS 30W ZY-P3-30W CDS 30W ZY-P3-30W CNS 30W ZY-P1-36W CDS 36W Model ZY-S35W-36-C1000 ZY-P1-36W CNS 36W ZY-P1-30W CDS 30W ZY-P1-30W CNS 30W ZY-P8-30W CDS 30W ZY-P8-30W CNS 30W Table 1 Hence, model ZY-P4-36W CDS were subject for full test, and the corresponding data is representative of derivative models list in table 1 as well.

- Page 7 of 20-4312774.52 Figure 1 model ZY-P4-36W CDS Figure 2 model ZY-P4-36W CDS The Operating Modes as stated in the User Manual are on mode and off mode.

- Page 8 of 20-4312774.52 4.2 Product Information Equipment under test Trade mark Tested Type U nominal P rated Highest frequency used in the device LED Panel Light James ZY-P4-36W CDS 100Vac, 60Hz, Class I, 36W less than 108 MHz Representative Type ZY-P4-36W CDS series U nominal 100Vac, 60Hz, Class I P rated Refer table 1 Highest frequency used in the device less than 108 MHz 4.3 Customer Information Applicant / Manufacturer James Industry Group Co., Ltd Contact person Mr DENG JINSHENG Telephone +852-3173 3712 Telefax +852-3173 3713 Address Room 1205(S01), 12/F., Tai Sang Bank Bldg 130-132 DES VOEUX RD, CENTRAL, HONGKONG Factory DONGGUAN ZHIYUAN LIGHTING TECHNOLOGY CO., LTD Contact person Mr DENG JINSHENG Telephone +86-13500093572 Telefax +86-769-22991702 ChuangYe Industry Park, XinXiBian, LiXinNiuShan, Address DongCheng District, DongGuan City, GuangDong Province, China 523128

- Page 9 of 20-4312774.52 4.4 Product labeling According to section 15.19, the DUT shall have the following statement labeled to its housing on a conspicuous location: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4.5 User information The user- or instruction manual shall: Caution the user that changes or modifications not expressly approved by the responsible party for compliance could void the user s authority to operate the equipment. Inform the user about special RF emission protection measures, which are delivered with the product, for example shielded cables. Contain the following statement in case of a Class B digital device: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and the receiver - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/tv technician for help

- Page 10 of 20-4312774.52 5 TEST INFORMATION 5.1 Test facility The FCC has per public notice declared these measurement facilities to be reviewed and to be in compliance with the requirements of Section 2.948 of the FCC Rules. 5.2 Measurement procedure The DUT was configured for testing in a typical user configuration. The maximum test configuration was put to the tests. The DUT was tested as complete system. 5.3 Test data Location Address DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Building A3, No.3 Qiyun Road, Science City, Guangzhou Hi-Tech Industrial Development Zone, Guangzhou, P.R. China Date 2013-07-02 to 2013-09-09 Supervised by Ryan Liang 5.4 Environmental conditions Tests have been performed in a controlled laboratory environment, where the environmental conditions are maintained within the applicable ranges. Ambient temperature 15 C 35 C Relative Humidity air 30% - 60%

- Page 11 of 20-4312774.52 6 CONDUCTED EMISSIONS 6.1 Measurement procedure In accordance with section 15.107 the conducted radio frequency disturbance voltages between each of the power lines (live and neutral) and the ground terminal are determined over the frequency range from 150 khz to 30 MHz. The test set-up is in accordance with the requirements of ANSI C63.4. The AC power line conducted emission measurements were performed at the line voltage of 120 Vac and at the power frequency of 60 Hz. The initial step in collecting conducted data is a peak scan measurement over the frequency range of interest. Significant peaks are marked, and these peaks are re-measured using a quasi peak and average detector. This procedure is implemented in the utilized test receiver by the incorporated EMI firmware. The test receiver used also meets the requirement as mentioned in section 15.35 measurement detector functions and bandwidths. The test receiver employs a CISPR quasi-peak detector function with a bandwidth of 9-10 khz. 6.2 Measurement equipment Instrumentation Model Serial no. Cal interval EMI receiver R&S ESCI Annual LISN R&S ENV216 Annual CABLE R&S 3M Annual Shielded room Feite Electronic -- Annual

- Page 12 of 20-4312774.52 6.3 Measurement data Limits Standard 47CFR subpart B clause 15.107 (a) (Class B) Frequency [MHz] Limit QP [db(µv)] Limit AV [db(µv)] 0,15 0,50 66 56 *) 56-46 *) 0,50 5,0 56 46 0,50 30,0 60 50 *) Limits decreasing linearly with the logarithm of the frequency Port Test method Test-mode AC mains LISN On mode Results Live dbµv 90 Att 10 db AUTO RBW 9 khz MT 1 s PREAMP ON 1 MHz 10 MHz 1 PK MAXH 80 70 2 AV MAXH FCCBQ 60 FCCBA 50 TDS 40 30 6DB DC 20 10 0-10 150 khz 30 MHz

- Page 13 of 20-4312774.52 EDIT PEAK LIST (Final Measurement Results) Trace1: FCCBQ Trace2: FCCBA Trace3: --- TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 1 Quasi Peak 150 khz 62.80-3.19 1 Quasi Peak 4.054 MHz 52.68-3.32 1 Quasi Peak 3.518 MHz 52.33-3.66 2 Average 3.878 MHz 40.36-5.63 2 Average 182 khz 48.58-5.80 2 Average 3.526 MHz 39.87-6.12 1 Quasi Peak 16.15 MHz 52.36-7.63 2 Average 16.694 MHz 41.89-8.10 2 Average 17.77 MHz 40.84-9.15 1 Quasi Peak 1.99 MHz 45.65-10.34 1 Quasi Peak 18.538 MHz 48.62-11.37 1 Quasi Peak 8.046 MHz 48.53-11.46 2 Average 2.03 MHz 34.37-11.63 2 Average 7.734 MHz 38.15-11.85 1 Quasi Peak 258 khz 47.39-14.09 1 Quasi Peak 1.074 MHz 41.38-14.62 1 Quasi Peak 478 khz 40.55-15.81 2 Average 482 khz 29.92-16.38 2 Average 418 khz 30.08-17.40 2 Average 1.198 MHz 28.44-17.55 No other significant emissions were measured at the frequency range of interest employing both the QP and AV detectors. Neutral dbµv 90 Att 10 db AUTO RBW 9 khz MT 1 s PREAMP ON 1 MHz 10 MHz 1 PK MAXH 80 70 2 AV MAXH FCCBQ 60 FCCBA 50 TDS 40 30 6DB DC 20 10 0-10 150 khz 30 MHz

- Page 14 of 20-4312774.52 EDIT PEAK LIST (Final Measurement Results) Trace1: FCCBQ Trace2: FCCBA Trace3: --- TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 1 Quasi Peak 150 khz 62.81-3.18 1 Quasi Peak 3.878 MHz 52.73-3.26 2 Average 182 khz 49.44-4.95 1 Quasi Peak 3.466 MHz 50.43-5.56 2 Average 3.522 MHz 40.34-5.65 2 Average 3.706 MHz 39.87-6.12 2 Average 15.822 MHz 41.90-8.09 1 Quasi Peak 16.762 MHz 51.85-8.14 2 Average 17.958 MHz 41.21-8.78 1 Quasi Peak 17.966 MHz 50.65-9.34 1 Quasi Peak 1.974 MHz 45.30-10.69 2 Average 7.522 MHz 39.05-10.94 1 Quasi Peak 7.698 MHz 48.90-11.09 2 Average 1.97 MHz 34.06-11.93 1 Quasi Peak 258 khz 48.61-12.88 2 Average 478 khz 31.67-14.70 1 Quasi Peak 434 khz 40.50-16.67 1 Quasi Peak 1.086 MHz 39.31-16.68 2 Average 302 khz 32.70-17.48 2 Average 1.082 MHz 27.85-18.14 No other significant emissions were measured at the frequency range of interest employing both the QP and AV detectors. Refer to chapter 8 for the test set-up. Conclusion: PASS

- Page 15 of 20-4312774.52 7 RADIATED EMISSIONS 7.1 Measurement procedure In accordance with section 15.109.a the field strength levels of radiated emissions from this digital device class B at a measurement distance of 3 meters were determined. If the highest internal frequency used in the DUT is less than 108 MHz, then the frequency range of interest shall be measured to 1 GHz. The measurements are conducted in accordance with the methodology as described in ANSI C63.4, as required by sections 15.31 and 15.33 of 47CFR. Below or equal to 1 GHz, preliminary radiation measurements are performed in a semi anechoic room at a 3 meter measurement distance. The measurement receiver calculates the resulting field strength using the correction factors for cable loss and antenna. The final measurements are performed in the semi anechoic room at a 3 meter measurement distance too. At those frequencies where relevant significant levels were detected during the pre-scan the actual field strength level is measured using the CISPR quasi-peak detector with bandwidth of 120 khz. The highest levels measured with horizontal or vertical polarization are mentioned on the next page. 7.2 Measurement equipment Instrumentation Model Serial no. Cal interval EMI receiver R&S ESCI Annual Antenna (30MHz-3GHz) SCHWARZBECK VULB9163 Annual CABLE SCHWARZBECK 10M Annual Chamber ETS.LINDGREN 9*6*6 Annual

- Page 16 of 20-4312774.52 7.3 Measurement data Limits Standard 47CFR subpart B clause 15.109 (a) (Class B) Measuring distance 3 meters Frequency [MHz] QP [db(µv/m)] microvolts/meter 30 88 40,0 100 88 216 43,5 150 216 960 46,0 200 960 1000 53,9 500 Port Test set-up Test mode Enclosure with cabling 3 m Semi-Anechoic chamber On mode Results Horizontal dbµv /m 70 Att 10 db RBW 120 khz MT 10 ms PREAMP ON 100 MHz 1 GHz 1 PK MAXH 60 50 TDS FCC-B 40 30 6DB DC 20 10 0 30 MHz 1 GHz No significant emissions were recorded employing the QP detector at the frequency range of interest (More than 20 db below limits).

- Page 17 of 20-4312774.52 Vertical dbµv /m 70 Att 10 db RBW 120 khz MT 1 s PREAMP ON 100 MHz 1 GHz 1 PK MAXH 60 50 TDS FCC-B 40 30 6DB DC 20 10 0 30 MHz 1 GHz EDIT PEAK LIST (Final Measurement Results) Trace1: FCC-B Trace2: --- Trace3: --- TRACE FREQUENCY LEVEL dbµv/m DELTA LIMIT db 1 Quasi Peak 30.76 MHz 34.05-5.94 No other significant emissions were recorded employing the QP detector at the frequency range of interest. Refer to chapter 8 for the test set-up. Conclusion: PASS

- Page 18 of 20-4312774.52 8 TEST SETUP AND ARRANGEMENT The photograph shows the tested device. Figure 3 Conducted Emission test setup Figure 4 Radiated emission test setup

- Page 19 of 20-4312774.52 9 PRODUCT INTERNAL PHOTO LED driver LED driver

- Page 20 of 20-4312774.52 LED driver PCB view LED driver PCB view