CAEN Tools for Discovery

Similar documents
The accurate calibration of all detectors is crucial for the subsequent data

The data acquisition system of the XMASS experiment

Pixie Viewer Online Help

Febex Data Acquisition System

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

GAMMA-RAY SPECTRA REFERENCES

A Digital Spectrometer Approach to Obtaining Multiple Time-Resolved Gamma-Ray. Spectra for Pulsed Spectroscopy. W. K. Warburton a

Electron-Muon Ranger (EMR)

ISTITUTO NAZIONALE DI FISICA NUCLEARE

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

Algorithms for digital γ-ray spectroscopy

Tutorial 4.6 Gamma Spectrum Analysis

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Experiment 5. Lasers and laser mode structure

Electronics GRETINA Project

RF Measurements Using a Modular Digitizer

Accurate Measurement of the Mains Electricity Frequency

Electron-Muon Ranger (EMR)

VME Data Acquisition System: Fundamentals and Beyond. Abhinav Kumar Bhabha Atomic Research Centre, Mumbai March 2011

DAC Digital To Analog Converter

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

LLRF. Digital RF Stabilization System

DEVELOPMENT OF DEVICES AND METHODS FOR PHASE AND AC LINEARITY MEASUREMENTS IN DIGITIZERS

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

How To Use A High Definition Oscilloscope

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

LEVERAGING FPGA AND CPLD DIGITAL LOGIC TO IMPLEMENT ANALOG TO DIGITAL CONVERTERS

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

APPLICATION NOTE GaGe CompuScope based Lightning Monitoring System

How To Use An Ionsonic Microscope

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Radiation Detection and Measurement

ORTEC. Fast-Timing Discriminator Introduction. Choosing the Right Timing Discriminator for the Application. Counting

Overview of the GRETINA Auxiliary Detector Interface

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

ECONseries Low Cost USB DAQ

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Description: Multiparameter System (4 or 8 channels)

PoS(PhotoDet 2012)068

Digital to Analog and Analog to Digital Conversion

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

The 104 Duke_ACC Machine

CHAPTER 11: Flip Flops

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Proton tracking for medical imaging and dosimetry

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Neutron Detection Setups proposed for

Clock Jitter Definitions and Measurement Methods

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Atomic and Nuclear Physics Laboratory (Physics 4780)

PLAS: Analog memory ASIC Conceptual design & development status

T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades

Atmel Norway XMEGA Introduction

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

Switch Mode Power Supply Topologies

Development of the electromagnetic calorimeter waveform digitizers for the Fermilab Muon g-2 experiment

PCM Encoding and Decoding:

CHAPTER 6 PHOTON COUNTING

S2000 Spectrometer Data Sheet

ORTEC AN34 Experiment 7 High-Resolution Gamma-Ray Spectroscopy

AGIPD Interface Electronic Prototyping

Chapter 6: From Digital-to-Analog and Back Again

MONOCHROME RGB YCbCr VIDEO DIGITIZER

Interfacing Analog to Digital Data Converters

What is LOG Storm and what is it useful for?

Section 3. Sensor to ADC Design Example

Evaluation Tools for the Performance of a NESTOR Test Detector

Measurement of Muon Lifetime and Mass Using Cosmic Ray Showers

Embest DSO2300 USB Oscilloscope

Experiment # 9. Clock generator circuits & Counters. Eng. Waleed Y. Mousa

Counters and Decoders

SignalPad Data Logging and Analysis Software

Reconfigurable System-on-Chip Design

Current Probes, More Useful Than You Think

An Innovative, portable MCA based on Digital Signal Processing. R.D. Bingham, R.M. Keyser, T.R. Twomey

Apple iphone/ipod Touch - ieffect Mobile Guitar Effect Accessory & Application

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

Lab 1: The Digital Oscilloscope

Timer A (0 and 1) and PWM EE3376

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.

DIGITAL COUNTERS. Q B Q A = 00 initially. Q B Q A = 01 after the first clock pulse.

Instructions for Setting the T560 Digital Delay Generator for the Target Delay

Vector Signal Analyzer FSQ-K70

Introduction to Geiger Counters

Transcription:

Viareggio April 22, 2010 Introduction The aim of this paper is to compare the energy resolution of two gamma ray spectroscopy setups based on two different acquisition chains; the first chain uses an analog V792N QDC, the other one is based on a 12 bit, 250 MS/s V1720 digitizer with a charge integrating Digital Pulse Processing (DPP CI). In order to perform the comparison between the two chains, gamma ray sources were used, 137 Cs and 60 Co. The spectra of the sources were acquired by the two different chains and compared performing least squares fits on the characteristic emission peaks in order to estimate the energy resolutions. Traditional analog QDC chain and Digital Pulse Processing [1] The function of the Front End electronics for nuclear physics applications is to acquire the electrical charge pulses generated by a radiation detector (see Fig. 1), to extract the quantities of interest and to convert them into a digital format that are then acquired, saved and analyzed by a computer. In most applications, the quantities of interest are the particle energy (proportional to the charge released by the particle in the detector) and the time of arrival. The acquisition system is usually completed by digital logic units whose purpose is to make coincidences, generate triggers, PARTICLE TYPE vetoes and other signals that take into account the correlation DETECTOR TIMING CHARGE = ENERGY between different channels and may give further information such as the particle position or trajectory. Traditionally, the electronic readout systems for particle detectors have been made of almost all analog chains. Each block of the chain has a specific function, so that you need to interconnect several blocks in order to make a system able to extract all the quantities of interest. This approach is rather rigid POSITION or TRAJECTORY Fig. 1: Electrical charge pulse generated by a detector because you need to change the hardware blocks in case you want to perform another type of acquisition to measure different parameters. In the case of some detectors, e.g. PMTs, that give a signal sufficiently strong to be fed directly into the readout electronics, the energy information is represented by the area below the pulse and this is normally measured by a Charge ADC (QDC). The QDC (see Fig. 2) is a pure integrator that requires a gate signal to define the integrating window. In some applications (most likely in beam experiments) the gate is provided by the system that knows in advance when the signals have to be integrated. Unfortunately, when this is not the case, it is necessary to generate the gate from the detector signals; to do that, you need to split the signals, send one branch to the discriminators and use a coincidence logic. It is also necessary to add a delay line (typically a long cable) on the signal path to the QDC input in order to match the pulses with the gate (which arrives with some latency respect to the analog pulses that produced it). DETECTOR CFD GATE DELAYED SIGNAL TIME Fig. 2: Signals in the QDC based chain Q = ENERGY ZERO CROSSING CHARGE INTEGRATION In an ideal acquisition system, the analog signal is converted into a digital data stream as earliest as possible and then transferred, without any loss of information, to a computer that can make the analysis and measure the quantities of interest off line. This is the basic principle of operation of a Waveform Digitizer (also known as Transient Recorder or Flash ADC). However, in the real world, there are some restrictions: the A/D conversion is always affected by an error that depends on the sampling frequency and the number of bit (resolution) of the ADC. Besides the loss of information due to the A/D conversion error, the major problem of the fully digital approach is the huge amount of data to readout. It is almost impossible to have a system in which the data throughput rate allows the acquisition (i.e. digitization) to be sustained continuously on all the inputs. Therefore, it is necessary to restrict the acquisition to some selected parts of the signals. Like in a common oscilloscope, this happens firstly by means of the trigger whose purpose is to define a certain time window in which the signal has to be recorded (acquisition window). The difference between a common oscilloscope and a digitizer is that the latter has several memory buffers for the triggers and can save subsequent acquisition windows without any dead time between them. Therefore, the acquisition can take place without the loss of any event, no matter what is the frequency and the distribution of them, at least until the readout rate allows the memory buffer to be read and freed on average faster than they are written, thus 1

avoiding the memory to go full. In a digitizer, there is an FPGA that continuously writes the digital samples coming from the ADC into a circular memory buffer; when it receives the trigger, it keeps saving the post trigger samples, then freezes that buffer (which is made available for the readout) and continues to save the samples into a new buffer. The record length (number of samples in the acquisition window) and the size of the post trigger are both programmable. In any case, the big advantage of the digitizers respect to the traditional acquisition systems is that the DPP algorithms are implemented in an FPGA and can be reprogrammed at any time. In one single module you have the complete information and the INPUT INPUT a b TRG & TIMING FILTER D DELAY b = RiseTime TIMING FILTER a = Low Pass mean GATE Nsbl = Baseline mean DELAYED INPUT D = Delay (Pre-Gate) Thr Nsbl Measures: Analog QDC Equipment used from CAEN BASELINE MEAN COMP CLK TRIGGER SUB N1470 4 Channel Programmable HV Power Supply N842 8 Channel Constant Fraction Discriminator N93B Dual Timer N146 Programmable Delay N147 Programmable Attenuator V792N 16 Channels QDC A 315 Splitter Other equipment used Thr = TRG Threshold W = Gate width COUNTER W MONOSTABLE GATE TIME STAMP ACCUMULATOR (INTEGRATOR) CHARGE Fig. 3: Digital Pulse Processing Charge Integration Source NaI(Tl) Fig. 4: Analog QDC chain Oscilloscope NaI(Tl) Crystal and Photomultiplier Tube Assembly (9265KB) Photomultiplier Base (Voltage Divider) Spectrum Techniques RSS 5 Sealed Solid Disk Gamma Ray Sources 1 µc 137 Cs, 60 Co PMT N1470 HV Supply capability to extract all the quantities of interest; just change the algorithm to get another parameter. CAEN is continuously developing new digital algorithms in order to fit as many applications as possible. The user can easily download the firmware he needs into the digitizer and upgrade the functionality of the module. Digital charge integration (see Fig. 3) is being implemented in the V1720 (8 channel, 12 bit, 250 MS/s digitizer). The main features of the Digital charge integration are as follows: Digital implementation of the QDC + discriminator and gate generator Implemented in the 12 bit, high speed digitizers Mod. 720 Self gating integration; no delay line to fit the pulse within the gate Automatic pedestal subtraction Extremely high dynamic range Dead timeless acquisition (no conversion time) Energy and timing information can be combined On line coincidences between couples of channels Input sensitivity: 40 fc per count N146 Delay N842 CFD N147 Attenuator N93B Dual Timer V792N QDC 2

Sofware used CAEN QTP demo ROOT data analysis framework (http://root.cern.ch/drupal/) Equipment Setup N1470 HV Power Supply: HV set at about the middle of the acceptable operating range, G 5 10 4 (850 V). N842 CFD: Used only one channel; other channels disabled. Threshold = 5 mv; Dead Time = 150 ns; Width = 50 ns. N93B Dual Timer: Section 1: WDT = 800 ns; Section 2 = 1.5 µs. N146 Delay: 50 ns. N147 Attenuator: 3.0 db. V792N: Sliding Scale enabled; Zero Suppression disabled; Overflow Suppression enabled. Split the PMT output using the A315, 50 Ohm adapted splitter. One branch, delayed and attenuated using N146 and N147, feeds one of the V792N QDC inputs. The second branch is used as N842 CFD PMT IN CFD VETO OUT Fig. 5: CDF and Dual Timer setup Dual Timer Section 1 START OUT START OUT spectrum subtracted and without the software evaluated background. OUT Dual Timer Section 2 QDC GATE input. The discriminator output is used (see Fig. 5) as Start for the first section of the N93B Dual Timer whose output is the Gate for the V792N and starts the second section of the Dual Timer. The output of this section is used as veto for the CFD in order to prevent the gate to be triggered by the noise of the PMT output and to discard pile up events and PMT after pulses. Three different spectra were acquired with this setup: 137 Cs, 60 Co (placing the sources 2 cm in front of the PMT) and background. Each data taking lasted 15 minutes. A ROOT script was used for data analysis. This tool reads data files of the spectra, subtracts the background to the 137 Cs and 60 Co histograms and applies a background removing algorithm which enhances the peaks for a better Gaussian fitting (the algorithm is implemented in the TSpectrum ROOT class). In Fig. 6, 7, 8 the spectra are shown: raw, with the measured background Fig. 6: V792N Raw spectra 3

Fig. 7: V792N 60 Co and 137 Cs spectra after background subtraction (black) and software evaluated background (red) Fig. 8: V792N 60 Co and 137 Cs spectra after the software evaluated background subtraction 4

Measures: Digital Pulse Processing Charge Integration Equipment used from CAEN N1470 4 Channel Programmable HV Power Supply V1720 8 Channel 12bit 250 MS/s Digitizer with DPP CI Other equipment used NaI(Tl) N1470 HV Supply Oscilloscope NaI(Tl) Crystal and Photomultiplier Tube Assembly (9265KB) Fig. 9: Digital QDC Chain Photomultiplier Base (Voltage Divider) Spectrum Techniques RSS 5 Sealed Solid Disk Gamma Ray Sources 1 µc 137 Cs, 60 Co Sofware used CAEN DPP_CI_Runner ROOT data analysis framework (http://root.cern.ch/drupal/) Equipment Setup PMT V1720 Digitizer N1470 HV Supply: HV set at about the middle of the acceptable operating range, G ~ 5 10 4 (850 V) V1720 DPP CI: Trigger: Threshold = 27 LSB; Mean (a) = 256 ns; Rise Time (b) = 56 ns Gate (Fixed): Gate width = 800 ns; Gate PreTrigger width = 80 ns; Holdoff width = 1.5 µs Baseline: BSL Inhibit Threshold = 5 LSB; BSL Inhibit Width = 2.6 µs; BSL Mean = 2 µs V1720 channel 0 was fed directly by the PMT output. CAEN DPP_CI_Runner was used to control the digitizer, i.e. to set parameters for data taking and DPP CI and to monitor the signals using the digitizer as oscilloscope. Once the parameters were set properly, the oscilloscope mode was disabled asking the DPP CI to store in memory only the energy, i.e. charge, values calculated in order to reach higher rates avoiding the memory to go full. Fig. 10 shows the waveforms used and calculated by DPP. Fig. 10: V1720 Red: inverted input; Green: delta signal (used in Trigger generation); Blue: Holdoff (Gate generation inhibit); Purple: Gate Three spectra ( 137 Cs, 60 Co and background) were acquired as previously described for 15 minutes. The same ROOT script was used for data analysis. In Fig. 11, 12, 13 the spectra are shown: raw, with the measured background spectrum subtracted and without the software evaluated background. 5

Fig. 11: V1720 Raw spectra Fig. 12: V1720 60 Co and 137 Cs spectra after background subtraction (black) and software evaluated background (red) 6

Fig. 13: V1720 60 Co and 137 Cs spectra after the software evaluated background subtraction Results Least squares fits were performed on the spectra with the software evaluated background subtracted using Gaussian functions. The fitted peaks were: 137 Cs 60 Co 481 kev Compton edge 662 kev gamma ray emission peak The results are shown in Tab. 1, 2; Fig. 14 summarizes the results. 1,17 MeV gamma ray emission peak 1,33 MeV gamma ray emission peak 2,51 MeV sum peak Energy (MeV) Mean (channel) σ (channel) Resolution (FWHM*100/Mean) 0.481 763.2 ± 1.3 41.6 ± 0.7 12.8 ± 0.7 0.662 1036.0± 0.1 35.92 ± 0.06 8.17 ± 0.04 1.17 1661.4 ± 0.4 47.0 ± 0.4 6.66 ± 0.18 1.33 1868.0 ± 0.4 46.7 ± 0.3 5.89 ± 0.13 2.51 3671.9 ± 1.1 63.9 ± 1.3 4.1 ± 0.24 Tab. 1: V792N Fit results Energy (MeV) Mean (channel) σ (channel) Resolution (FWHM*100/Mean) 0.481 4503±5 180±8 9.41±1.18 0.662 6737.1±0.4 200.4±0.4 7.01±0.04 1.17 12588.7±0.5 303.0±0.6 5.67±0.03 1.33 14471.7±0.5 340.8±0.5 5.546±0.024 2.51 30937±4 502±5 3.82±0.11 Tab. 2: V1720 Fit results 7

Resolution comparision Analog QDC vs DPP CI 13 Res. [%] 11 9 7 DPP-CI Analog QDC 5 3 0,3 0,8 1,3 1,8 2,3 2,8 Energy [MeV] Fig. 14: Resolutions of the V792 and V1720 based QDC chains Conclusion Two different acquisition chains for gamma ray spectroscopy were tested, one based on an analog V792N QDC and the other based on a V1720 digitizer with a charge integrating DPP. Two different gamma ray sources were used in order to compare the energy resolutions of the two setups, 137 Cs and 60 Co. The preliminary results seems to highlight the better energy resolution of V1720 with DPP CI than the V792N one, especially considering the three gamma ray emission peaks ( 137 Cs 0.662 MeV, 60 Co 1,17 1,33 MeV) whose shape and high statistics minimize fit uncertainties. References [1] C. Tintori, WP2081 Digital Pulse Processing in Nuclear Physics CAEN White Paper. rev.0 00117 10 DGT17 ANXX Copyright CAEN SpA. All rights reserved. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. CAEN CAEN SpA Via Vetraia 11 55049 Viareggio Italy Tel +39.0584.388.398 Fax +39.0584.388.959 info@caen.it www.caen.it www.caen.it 8