Management Tools. Contents. Overview. MegaRAID Storage Manager. Supported Operating Systems MegaRAID CLI. Key Features



Similar documents
Configuring ThinkServer RAID 100 on the Lenovo TS130

12Gb/s MegaRAID SAS Software

Contents. Overview. Drive Policy RAID 500 features. Disable BGI RAID 700 features. Management Tasks Choosing the RAID Level.

MSM Software Feature Difference Between the MR Controller and the IR Controller

Intel RAID Web Console 2 and StorCLI Command Line Tool

MegaRAID SAS User Guide for Linux

USER S GUIDE. MegaRAID SAS Software. April , Rev. D

Configuring ThinkServer RAID 100 on the Lenovo TS430

Configuring ThinkServer RAID 100 on the TS140 and TS440

User Guide - English. Embedded MegaRAID Software

USER S GUIDE. MegaRAID SAS Software. June 2007 Version , Rev. B

NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later

The following is a preview of an Nfina storage system with an embedded LSI RAID controller using MegaRAID Storage Manager software.

ASM_readme_6_10_18451.txt README.TXT

USER S GUIDE. MegaRAID SAS Software. March Rev. F

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

README.TXT

QuickSpecs. Models HP Smart Array E200 Controller. Upgrade Options Cache Upgrade. Overview

README.TXT

This chapter explains how to update device drivers and apply hotfix.

NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition -

Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer

Integration and Automation with Lenovo XClarity Administrator

MegaRAID SAS Device Driver Installation

SAP Certifications for Lenovo Servers

readme.txt README.TXT

Dell SAS RAID Storage Manager. User s Guide. support.dell.com

LSI MegaRAID User s Manual

ThinkServer RS140 Operating System Installation Guide

User Manual for SAS RAID 2108

MegaRAID Configuration Software

MegaRaid SAS Software

How to Setup and Configure ESXi 5.0 and ESXi 5.1 for OpenManage Essentials

MegaRAID SAS Device Driver Installation

Installing and Configuring SAS Hardware RAID on HP Workstations

Important Notice RAID System Monitoring on VMware vsphere 5 vsphere Client

Management of VMware ESXi. on HP ProLiant Servers

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

Intel RAID Software User s Guide:

Intel Server Raid Controller. RAID Configuration Utility (RCU)

readme.txt README.TXT

Manage Dell Hardware in a Virtual Environment Using OpenManage Integration for VMware vcenter

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

Intel RAID Basic Troubleshooting Guide

Intel RAID Controller Command Line Tool 2 User Guide. Order Number: E

README.TXT

Acronis Backup & Recovery 11

SATA RAID Controller Command Line Interface

README.TXT

Smart Server Manager v1.2 Best Practices. Smart Server Manager v1.2 Best Practices Guide

Acronis Backup & Recovery 10 Workstation. Installation Guide

Intel RAID Software User s Guide:

Proactively Managing Servers with Dell KACE and Open Manage Essentials

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

Intel RAID Software User s Guide:

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Lenovo Partner Pack for System Center Operations Manager

ServeRAID-MR Software

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

readme_asm.txt README.TXT

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

Acronis Backup & Recovery 10 Server for Windows. Installation Guide

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

MegaRAID RAID Controller Configuration Software Guide

You can create configurations using the following modes:

README.TXT

HP VMware ESXi 5.0 and Updates Getting Started Guide

NetIQ Sentinel Quick Start Guide

Embedded MegaRAID Software

ThinkServer RD350 and RD450 Operating System Installation Guide

Acronis Disk Director 11 Advanced Server. Quick Start Guide

Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager Part Number D01

PROMISE ARRAY MANAGEMENT (PAM) for

Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance

HP Array Configuration Utility User Guide

NEXLINK STABLEFLEX MODULAR SERVER

Acronis Backup & Recovery 11.5

HP Insight Control for Microsoft System Center integration overview

Intel Rapid Storage Technology Enterprise (Intel RSTe) Software User s Guide. Revision 1.1 February, 2012 Order Number: G

ServeRAID M5000 Series Performance Accelerator Key for IBM System x Product Guide

VCE Vision Intelligent Operations Version 2.5 Technical Overview

USER S GUIDE. MegaRAID SAS Device Driver Installation. June Rev.D

Intel Matrix Storage Console

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Intel RAID Software User s Guide:

README.TXT

Spotlight Management Pack for SCOM

PIKE LSISAS RAID card. User Guide

Remote/Branch Office IT Consolidation with Lenovo S2200 SAN and Microsoft Hyper-V

o Support for maxcache Plus caching and tiering software on Windows and Linux

McAfee Application Control / Change Control Administration Intel Security Education Services Administration Course

Oracle Enterprise Manager

Embedded MegaRAID Software

Comparison: Microsoft Logical Disk Manager (LDM) and VERITAS Volume Manager

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide

Microsoft Exchange 2010 on Dell Systems. Simple Distributed Configurations

Transcription:

Introduction to ThinkServer RAID Management Tools Contents Overview 1 MegaRAID Storage Manager 03 MegaRAID CLI 04 04 MegaRAID SNMP Agent MegaRAID CIM Provider Obtaining the Tools

Overview Lenovo offers a suite of management tools to simplify the use and management of ThinkServer systems. In addition, Lenovo makes available management solutions from LSI to manage ThinkServer RAID adapters. These management solutions enable ThinkServer RAID 100, 500, and 700 adapters with LSI technology to be managed through a command line interface (CLI) tool, MegaRAID CLI, or a graphical user interface (GUI) tool, MegaRAID Storage Manager. Additional support is also available for management with industry standard management consoles using CIM, and SNMP. This paper introduces the capabilities offered by these LSI RAID management tools for use on all supported ThinkServer systems with LSI based ThinkServer RAID 100, 500 or 700 adapters. Additional help and specification for installation and use of these tools can be found in the MegaRAID SAS Software User Guide. An overview of key MegaRAID Storage Manager capabilities are provided in this section. See the MegaRAID SAS Software User Guide See for a complete list of supported function Dashboard view providing Physical and logical views of the storage subsystem with hierarchy of controllers, virtual drives, and drive groups Properties of the virtual and physical drives Total capacity, configured capacity, and unconfigured capacity ackground operations in progress Actions that can performed, such as creating a virtual drive Status icons for controllers, drives, and other devices MegaRAID Storage Manager MegaRAID Storage Manager is a comprehensive GUI based client / server application that enables configuration and management of storage arrays locally or remotely on multiple servers. The graphical user interface makes it easy to configure, monitor, and maintain storage configurations on ThinkServer RAID adapters. Wizards in the tool simplify the creation and modification of virtual drive configurations. MegaRAID Storage Manager also displays the status of controllers, virtual drives, and drives on the servers being monitored, and with alerts and special icons on the screen, will notify administrators of drive failures and other events that require immediate attention. Figure 1 - Main Dashboard 2

Remote server discovery Discovery of managed servers Logging into a server Ability to Configure ThinkServer RAID adapters and attached devices Controllers, virtual drives, hard disk drives and other devices Creating new storage configurations using the Configuration Wizard (Simple Configuration mode and Advanced Configuration mode) Adding hot spare drives Changing adjustable task rates (background initialization, consistency checks, etc.) Changing power settings Changing a virtual drive configuration Modify drive group wizard Migrating a RAID level Deleting a virtual disk Allows monitoring or raid storage subsystems Display status of controllers, virtual drives, hard disk drives, and other devices Monitoring Battery Backup Units (BBU) Display event log file and on-screen alerts Monitoring of system events Configuring alert notifications and delivery methods Monitoring rebuilds and other background activities Maintenance Initiate and control background tasks such as patrol read, and consistency checks Initializing a virtual drive Scanning for new drives Rebuilding a drive Making a drive offline or missing Updating firmware MegaRAID Storage Manager has to two installation components. The Client component is MegaRAID Storage Manager software installed on a PC or server that is used to manage and monitor servers remotely over a network. It contains the MegaRAID Storage Manager GUI, and monitor configurator. The Server component is installed on the server to be monitored and provides the management interface to the Client monitor. Installation options combine these components to support various management configuration scenarios. MegaRAID Storage Manager also requires that LAN ports 3071 and 5571 be open in order to function. Figure 2 Configuration Menu 3 Figure 3 Configure Alerts

MegaRAID Storage Manager is supported on Windows server and client OS s, Linux (RedHat and SUSE / SLES), and Solaris. While support is available for VMWare, the MegaRAID Storage Manager server part cannot be installed directly in a VMWare ESXi host. Management is possible only through Common Information Model (CIM) providers. See MegaRAID CIM Provider for more information. MegaRAID CLI MegaCLI is a robust, standalone command line interface application. As a command line tool, it may not be well suited for general use, but it does allow complete control of all features and functions of the ThinkServer RAID adapters, and it can be scripted. A limited subset of the MegaCLI functionality is also available at pre-boot through the ThinkServer RAID adapter firmware. This function is accessed by pressing CTRL-Y during BIOS initialization. An overview of key MegaCLI features are provided in this section. See the MegaRAID SAS Software User Guide See for a complete list of commands and their usage. Provides ability to display information about and configure ThinkServer RAID adapters and attached devices including battery backup units, physical and virtual disks Create, delete, and modify virtual disk configurations View and change properties for the virtual drives, physical drives, and the controller Configure and control background tasks including virtual drive initialization, consistency checks, rebuild, reconstruction and patrol reads Load and save controller configuration from and to a file Scan, preview, and import foreign configurations Allows monitoring of RAID Storage systems Display information about virtual drives, the controller, and other storage components Show progress of ongoing operations on drives and virtual drives Display event logs using filters to show relevant messages on the console or in a log file Allows creation of scripts that can call the CLI tool Create and use scripts with the scriptable CLI tool Exit with predefined success or failure exit codes Display help for how to use the command line options Update firmware on the controller Some examples of MegaCLI commands demonstrate the power of this application. Command MegaCLI -AdpAllInfo -aall MegaCLI AdpAlILog a0 MegaCLI FwTermLog Dsply a0 MegaCLI PDList a0 MegaCLI EncInfo a0 MegaCLI LDInfo lall aall MegaCLI CfgClr a0 MegaCLI CfgAllFreeDrv r0 a0 MegaCLI CfgLdAdd r1[4:1,4,2] strpsz256 a0 MegaCLI AdpFwFlash f SAS9240_FW_ Image.rom a0 Description Get information about each adapter All-In-Log Retrieves all logs from controller Retrieves FW TTY log since last power cycle Get info about all connected PD Get info about attached enclosures Get info about all virtual disks Clear entire configuration Create a RAID 0 virtual drive on all free drives Create a RAID 1 virtual drive with stripe size of 256, using specified physical disks. Flash controller firmware Table 1 - Example MegaCLI Commands 4

MegaCLI is available for DOS, and Windows as a standalone executable. The tool is also supported in Linux, Solaris, SCO OpenServer, SCO Unixware, Netware, and FreeBSD. The function is the same under each Operating System. MegaRAID SNMP Agent Obtaining the Tools The tools discussed in this document are available from Lenovo for supported ThinkServer platforms, operating systems, and ThinkServer RAID adapters. http://support.lenovo.com/ MegaRAID Storage Manager for other host operating systems can be obtained from LSI. A Simple Network Management Protocol (SNMP)-based management application can monitor and manage devices through SNMP extension agents. The MegaRAID SNMP subagent is available in the MSM install package, and reports information about the RAID controller, virtual drives, physical devices, enclosures, and other items per SNMP request. The agent is also used to send SNMP alerts for RAID events or issues that might require immediate administrative attention. Click here to download the users guide on MegaRAID SAS Software The LSI MegaRAID SNMP agent is supported on Linux, Solaris, and Windows operating systems. MegaRAID CIM Provider An LSI MegaRAID Common Information Model (CIM) provider is available to support exchange of management information over networks with other systems management applications, for example Microsoft System Center. In addition, use of the CIM provider is required in order to enable management of RAID on VMWare hosts. The LSI CIM Provider is installed into ESXi, interacts with the RAID controller hardware, and interfaces with the CIM Object Manager (or CIMOM). MegaRAID Storage Manager installed on a remote machine interfaces with the CIMOM to provide management support. 2011 Lenovo. All rights reserved. Availability: Offers, prices, specifications and availability may change without notice. Lenovo is not responsible for photographic or typographic errors. Warranty: F or a copy of applicable warranties, write to: Warranty Information, 500 Park Offices Drive, RTP, N C, 27709, Attn: Dept. ZPYA/B600. Lenovo makes no representation or warranty regarding third-party products or services. Trademarks: Lenovo, the Lenovo logo, Rescue and Recovery, ThinkStation, ThinkVantage, and ThinkVision are trademarks or registered trademarks of Lenovo. Microsoft, Windows, and V ista are registered trademarks of Microsoft Corporation. Intel, the Intel logo, Intel Core, Core Inside, Xeon and Xeon Inside are registered trademarks of Intel Corporation in the U.S. and other countries. Other company, product, and service names may be trademarks or service marks of others. Visit www.lenovo.com/safecomputing periodically for the latest information on safe and effective computing. 5