ABB - Pôle Foudre Soulé & Hélita OVR PLUS N1 40



Similar documents
SURGE PROTECTIVE DEVICES

The power of nature, the control of technology From ABB's experience, OVR PV: surge protection in photovoltaic plants

Main catalog. System pro M compact Surge and lightning protection solutions with QuickSafe technology

R.C.C.B. s two-pole LEXIC

CATALOGUE SURGE PROTECTION LOW VOLTAGE

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

wietap wietap Overvoltage Protection Tensions running high

Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in

Surge Protection for Photovoltaic Systems

White paper. ABB solutions for switching and protection of low speed wind turbines

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

DEHNshield Application-optimised multipole combined lightning current and surge arrester

Power surges can also be generated by equipment in your facility such as:

Product Environmental Profile Step Down Transformers

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Transient and Lightning Protection for the Water Industries

Photovoltaic Solar Energy Unit EESFB

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

ABB solutions for photovoltaics Protection and other modular devices

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Product Regulatory Compliance Datasheet ediscovery 8200

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Unified requirements for systems with voltages above 1 kv up to 15 kv

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Product Regulatory Compliance Datasheet ediscovery 8100

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

ABB Inc. April 19, 2011 Slide 1

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Electrical safety and protection devices

How To Understand The Electrical Power Supply Of A Power Supply System

Connection Cable for LED Driver Board

Product Regulatory Compliance Datasheet NBU 5330

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

Hong Kong Green Label Scheme Product Environmental Criteria for Copying Machines, Printers, Fax Machines and Multifunctional Devices (GL )

SURGELOGIC TVSS Surge Protective Devices Enhance System Protection and Reduce Equipment Damage

A project to optimise quality and energy efficiency must include metering

ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue

Product Regulatory Compliance Datasheet BE3600

Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

ABB central inverters PVS to 1000 kw

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Applications. Remote Display Mounting Kits

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Surge Protection. Electrical Installations. Photovoltaic. Telecom. Data. Radiocommunication

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Environmental Product Declaration

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

GP2Y0A02YK0F. Distance Measuring Sensor Unit Measuring distance: 20 to 150 cm Analog output type GP2Y0A02YK0F

Protection catalogue 15

Telecommunication Line Protectors

1 POLE - 5A SLIM POWER RELAY

This is a preview - click here to buy the full publication TECHNICAL REPORT

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

How To Build A Low Voltage Capacitor Lvcp

A series of technology briefs spanning Tyco Electronics product portfolio

Data Center Integrated solutions

SAMI Microstar (SAMI MM, MD, MS)

AQUACIAT2 HYBRID THE COMPACT DUAL-ENERGY SOLUTION HEAT PUMP & GAS BOILER. Cooling and heating capacities of 45 to 80 kw AVAILABLE 2 ND QUARTER OF 2014

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Indoor / Outdoor Antenna

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

How can a charging station for electric vehicles be set up simply and safely?

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

The following components are common to most cubicles; this example is an ABB HK cubicle.

Data Assessment for Electrical Surge Protection Devices

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Urban lighting luminaire XMOD RX. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Anti-blackout system for grid connected solar installations (Solsafe concept)

Protect. Surge Protection for home and small office

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

China RoHS Directive Legislation Compliance October 2011

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

DC Combiner box and AC solutions. Leadership in circuit protection

Communication bridge Xcom-MS User Manual

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

SMART SENSOR COLLECTION

Universal control module for motorized devices

Transcription:

Presentation ABB - OVR PLUS N1 40 ABB France Lightning Protection Group

All in one product SPDs with integrated back up protection are a solution that allow to have a complete surge protection design into one product ABB has a range offering both solution to cover different market field Those products are a good solution in order to: Offer to customer a solution that many specialist don t have Offer a good solution for residential or commercial markets

Dedicated Applications TT & TNS networks (1 phase + neutral) Residential in high frequency lightning areas keraunic level >25 Commercial buildings with crucial electrical equipments : computer networks, switchboards, inverters

Main Advantages Auto-protected With its integrated end of life protection by MCB, no need of additional MCB or fuse. Compact 2 modules only to save space. Easy to install High performance Isc at Un: 15KA In : 20KA Discharge current With Im* 40kA, the OVR PLUS can be installed in high risk areas (keraunic level>25) *: Imax of the MOV Eco-Design & Recycling Innovative internal design: helps to reduce CO2 emissions

Main Advantages State Indicator Visual indication: The MCB lever contact indicates the state of the surge arrester S2C-H6R: As option, ABB prom Range auxiliary contact Complete ABB ProM design

Operating characteristics Very high flow capacity: Can afford one 40,000A impact (or 20 consecutive impacts of 20,000A) Secure End of Life: association of a bimetal sensor (patented) and an MCB EoL due to overvoltage: progressive warm-up of the varistor recognised by the bimetal sensor which causes the opening of the MCB EoL due to strike: the varistor is placed in short circuit, the MCB opens instantaneously

Operating characteristics Greater reliability Due to a brand new technology with no welding in the product : As soon as the internal temperature reaches 100 C the sensor automatically opens the MCB Full protection Common mode neutral/earth (gas spark gap) & differential phase/neutral (varistor) TT & TNS networks (1 phase + neutral)

A fully environmental product Reduced environmental impact: To produce the OVR PLUS N1 40, we have followed the Environmental management: life cycle assessment-principle & framework of ISO 14040 for the analysis of all phases of the cycle life of the product Compliance with the RoHS rules (2002/96/CE): Lead, mercury, hexavalent chromium, cadmium, PBB or PBDE free Very low consumption <220µA Compact and light (less plastic & metal) No welding => less energy for assembly, less raw material used, more reliable No dangerous material => can be destroyed by crushing

Technical data sheet- Electrical features

Technical data sheet mechanical features

Easy cabling 30m maximum Ph N T Equipment No additionnal fuse or breaker for end of life O,5m maxi

State indication Lever position of MCB «ON»: SPD connected Lever position of MCB «OFF»: To connect the SPD, put the lever position on «ON» Lever position of MCB «OFF» and impossible to put «ON»: The SPD is disconnected and you must replace it

Marketing Tools Leaflet of OVR PLUS Competitor analyse Technical Article High resolution pictures Data sheet Samples