Data Resource Systems, LLC. AGA 5.0 Gas Volume Calculator for Windows. User s Guide

Similar documents
ANNUBAR FLOW CALCULATION PROGRAM (For the FloBoss 103) User Manual (QER 04Q019)

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

Form Number A6043. Part Number D301224X012 March Flow Measurement. User Manual. Flow Computer Division. Website:

SIZING AND CAPACITIES OF GAS PIPING

Custody Transfer Measurement. with the V-Cone Flowmeter

V-CONE METERING PROGRAM User Manual

OIL & GAS PRODUCTION AUDITING

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Effects of Atmospheric Pressure on Gas Measurement

FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Fundamentals of Orifice Meter Measurement page 1. Fundamentals of Orifice Meter Measurement. What is an Orifice Meter? How does it work?

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

User s Manual Laminar Flow Elements

SIZING AND CAPACITIES OF GAS PIPING

FLUID FLOW Introduction General Description

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.

THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Thermal Dispersion Mass Flow

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

Experiment 3 Pipe Friction

The Unique Accelabar Flow Meter

Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2

Piping Hydraulic Line Design and Sizing Software KLM Technology Group

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

Rusty Walker, Corporate Trainer Hill PHOENIX

Technical & Sizing Bulletin for Meriam LFEs. Laminar Flow Elements

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

UNDERSTANDING REFRIGERANT TABLES

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Gas Custody Transfer Calibration

= 800 kg/m 3 (note that old units cancel out) J 1000 g = 4184 J/kg o C

Job Streaming User Guide

Microsoft Excel 2013: Macro to apply Custom Margins, Titles, Gridlines, Autofit Width & Add Macro to Quick Access Toolbar & How to Delete a Macro.

How does the Review Program work?

Enron (AGA7) Modbus Protocol

ODBC Reference Guide

Chokes. Types Reasons Basics of Operations Application

Microsoft Excel Basics

Fiscal Measurement Natural Gas

For Multi-Parameter Meters see mvx

COMPRESSED AIR ULTRASONIC LEAK DETECTION GUIDE

T U R B I N E G A S M E T E R

Guide To Creating Academic Posters Using Microsoft PowerPoint 2010

SENDING S & MESSAGES TO GROUPS

1. Standard conditions are in. Hg (760 mm Hg, psia) and 68 F (20 C).

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Manual of Petroleum Measurement Standards Chapter 11 Physical Properties Data

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

Gas Flow Measurement Software A Report for

QQConnect Overview Guide

Sizing Pressure Regulators & Control Valves

1805 Series Relief Valves

Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by:

Installing the Microsoft Network Driver Interface

You must have at least Editor access to your own mail database to run archiving.

Flow Measurement Options for Pipeline and Open Channel Flow

Air Eliminators and Combination Air Eliminators Strainers

Meriam Instrument LFE Data Sheet

CALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04

Exhaust Calculation Booklet

Pressure and Temperature Controls

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Microsoft Excel Tutorial

Users Guide. By Dr. Don J. Wood Dr. Srinivasa Lingireddy. Featuring the Surge Wizard

LP 2844 Thermal Printer

Electronic Timekeeping Supervisors Manual

CalPlanning. Smart View Essbase Ad Hoc Analysis

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

Micro Motion Net Oil Computer Software and NOC System

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

CO MPa (abs) 20 C

FLOW CALCULATION SOFTWARE. Version 4 User s Manual

Laminar Flow Elements

Fan Selection Application

Product Development. Using Critical Path EVM for the Microsoft Project Desktop Application Readme

Acceleration of Gravity Lab Basic Version

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

What's New in ADP Reporting?

User's Guide. Using RFDBManager. For 433 MHz / 2.4 GHz RF. Version

Methods and Equipment for Calibration of Variable Area Meters (Rotameters)

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010

Creating an Excel Spreadsheet Report

Creating a PowerPoint Poster using Windows

How To Analyze Data In Excel 2003 With A Powerpoint 3.5

Microsoft Dynamics GP. Advanced Financial Analysis

Transcription:

Data Resource Systems, LLC for Windows Version 5.0.2 User s Guide Special note: In this document where you see Error! Bookmark not defined. purchase of manual or software is required to view. Written by Steven B. Hughes President Hughes Gas Measurement, Inc. Page 1

Notice Every effort has been made to supply complete and accurate information. However, the author and Data Resource Systems, LLC assume no responsibility for its use. Copyright 1991-2003 by Steven B. Hughes World-wide rights reserved. Except for your own personal use, no part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including but not limited to photocopying, photograph, magnetic or other record, without prior agreement and written permission of Steven B. Hughes and Data Resource Systems, LLC, an Oklahoma limited liability company. Page 2

Table of Contents Introduction... 2 Features... 2 Installation Instructions, Hardware and Operating System... 3 Operation Instructions... 3 Variables... 4 Meter Tube... 4 Orifice Size... 5 Hours (Flow Time)... 5 Static Pressure... 5 Upstream Pressure Tap Solution... 5 Vacuum Pressure Solution... Error! Bookmark not defined. Differential Pressure... 6 Over-ranged Differential Reading Solution... Error! Bookmark not defined. Orifice well testers... Error! Bookmark not defined. Temperature... 6 Results... 6 Constants... 7 Components... 7 Carbon Dioxide (CO 2 )... 7 Nitrogen (N 2 )... 7 BTU... 7 Gravity... 7 Contract... 8 Temperature Base... 8 Pressure Base... 8 Barometric Pressure... 8 Ranges... 8 Differential... 8 Static... 8 Temperature... 8 Meter Tube Material... 8 Orifice Material... 8 Chart Type... 8 Tap Type... 8 Factors (Glossary)... 8 CPrime... 9 1 Hour Coefficient... 9 24 Hour Coefficient... 9 F b Basic orifice factor... 9 F pv Supercompressibility factor... 10 β Beta Ratio... 10 F gr Specific gravity factor... 10 F tf Flowing temperature factor... 10 F r Reynolds number factor... 11 F tb Temperature base factor... 11 Y Expansion factor... 11 Page 3

F pb Pressure base factor... 11 F m Manometer factor... 11 F l Gage location factor... 11 F a Orifice thermal expansion factor... 11 Special Features... 12 Volume to Plate (Backward calculation algorithm)... 12 Volume to Differential (Backward calculation algorithm)... 12 Data Files... 13 Printing of Data Sheet Report... 13 Application Notes... 14 Electronic Flow Computers... 14 Chart Recorders... 14 Linear... Error! Bookmark not defined. Percentage... Error! Bookmark not defined. Roots (L-10)... Error! Bookmark not defined. Volume Statements... 15 Field Volume Calculation Methods for Linear, Roots (L-10), Percentage... 16 Linear Chart...Error! Bookmark not defined. Percentage Chart...Error! Bookmark not defined. Roots (L-10):...Error! Bookmark not defined. Calculating Coefficients for Field Spot Readings with a Calculator... 17 Noted Errors in Report Printing... 18 Constants... 18 Factors... 18 References... 18 Support... 18 Page 4

Introduction Gas Volume Calculator for calculation of AGA 1992 and NX-19 Supercompressibility formulae for Linear (EFM), Roots (L-10), and Percentage charts. Windows, DOS and Pocket PC versions available. This software application is based on AGA calculation references. However, the AGA or American Gas Association has not made any endorsement of the DRS AGA 5.0 application. Features Volume to Plate Calculations Essentially backward calculates a new orifice plate size based upon a desired differential reading and the current gas volume. Volume to Differential Calculations Calculates the new differential pressure based upon the desired volume. Uses the current variables to determine the new differential pressure. Meter Data Files Information for individual sites is stored in dbase files for easy retrieval and recalculation. Reports Prints a single page report listing all variables, constants, factors and meter station name. Page 2

Installation Instructions, Hardware and Operating System Insert DRS AGA 5.0 CD into CD-ROM, the install program should automatically run. If it does not auto-run, go to Start, Run, Browse, My Computer, choose CD- ROM drive and click on the application entitled Setup, then folow the instructions. You must have a computer with a CD-ROM using Microsoft Windows 95 or a later version Microsoft Windows operating system. Operation Instructions Once the software is installed a screen like the one below will appear. Data must be entered on the Variable Page and on the Constants Page before a valid calculation will result. Instructions for calculating accurate gas volumes and flow rates are detailed in the following pages. Page 3

Variables Meter Tube Dimensions of Pipe Nominal Size Inches Published Inside Diameter, Inches 2 1.689 1.939 2.067 3 2.300 2.626 2.900 3.068 4 3.152 3.438 3.826 4.026 6 4.897 5.189 5.761 6.065 8 7.625 7.981 8.071 10 9.564 10.020 10.136 12 11.376 11.938 12.090 16 14.688 15.000 15.250 20 18.814 19.000 19.250 24 22.626 23.000 23.250 30 28.628 29.000 29.250 Table copied from GPA Engineering Data Book, 9 th edition, 1972. Maximum tube size entry for DRS AGA 5.0 is 50.000 inches. Page 4

Orifice Size Maximum orifice size is limited to 95% of tube size (0.95 Beta Ratio, e.g. Tube/Orifice Diameter) Minimum orifice size is limited to.010 inches. (Beta ratios above.65 will result in lower stated volumes) (Beta ratios below.12 will result in higher stated volumes) Hours (Flow Time) All volumes are calculated in thousand cubic feet (MCF) Normally set hours to 24 for MCFD calculations For 1 hour flow rates set hours to 1 for MCFH calculations Partial hours, days or total volume for an extended period (such as weekly or monthly) can be calculated up to 32,000 hours using averages for the period. Static Pressure Pressure readings are taken in PSIA, PSIG+atmospheric PSI, percentage of static pressure range, or roots. Upstream Pressure Tap Solution Pressure readings are taken at tap on downstream side of orifice plate in PSIA. If static pressure reading is taken at the upstream tap, then a correction for the excess pressure must be made in the static pressure entry as follows: PSIA upstream (Diff Pressure 27.6807) = PSIA downstream This calculation must be performed with the actual units of measurement, not percentages or roots. Vacuum Pressure Solution (purchase of manual or software required to view) Page 5

Differential Pressure Differential pressure readings are entered as inches of water column, percentage of differential pressure range or roots. Over-ranged Differential Reading Solution (purchase of manual or software required to view) Temperature Temperature in degrees Fahrenheit, percentage of temperature range or roots. Accepts values from -40 degrees to full range of temperature element range Results Volume calculation results are stated in thousand cubic feet (MCF) and million British thermal units (MMBTU). Page 6

Constants Components (Acquire values from a valid gas analysis) Carbon Dioxide (CO 2 ) Accept values from 0 to 15 percent Nitrogen (N 2 ) Accept values from 0 to 15 percent BTU Accepts values from 500 to 2000 BTU per cubic foot Gravity Accepts values from 0.500 to 1.000 Air = 1.000, Methane =.5539 Source - GPA Engineering Data Book, 9 th edition, 1972. Most published tables and circular slide rule orifice computers use.600 as standard for natural gas. Page 7

Contract Temperature Base Accepts values from 1 to 300 degrees Pressure Base Accepts values from 10.0 to 17.0 PSI Barometric Pressure Accepts values from 10.0 to 17.0 PSI Ranges {required for Percentage and Root (L-10) Calculations} Differential Enter the differential pressure range of the recorder. Accepts values greater than 1 and less than 15000. Static Enter the static pressure range of the recorder. Accepts values greater than 1 and greater than 5000 Temperature Enter the temperature range of the recorder. Accepts values greater than 1 and less than 240. Meter Tube Material 304 or 316 Stainless Carbon Steel Monel Orifice Material 304 or 316 Stainless Carbon Steel Monel Chart Type Linear Percentage Root (L-10) Tap Type Flange -Taps are together at the orifice fitting. Pipe -Taps are located upstream and downstream of the orifice by the length of several pipe diameters. Factors (Glossary) Page 8

CPrime =(C ) Orifice flow constant (Cubic feet per hour) [Dynamic factor] C = F b F r Y F pb F tb F tf F g F pv F m F a F l 1 Hour flow coefficient [for stating thousand cubic feet per hour: use is dependent upon chart type selected; linear, roots(l-10), percentage] [Dynamic factor] 24 Hour flow coefficient [for stating thousand cubic feet per day: use is dependent upon chart type selected; linear, roots(l-10), percentage] [Dynamic factor] F b Basic orifice factor [Orifice factor only; i.e. C without influence of other factors, but for cubic feet of air per hour.] Page 9

Factors (Glossary continued) Exercise: Examine all of the above factors including the Volume MCF while entering the following variables and constants into the DRS AGA 5.0 application. Differential = 0.065 (rounds to.07) Static = 14.73 Temperature = 60 Deg F Tube Size = 2.067 Orifice Size = 1.000 Hours = 1.0 CO2% = 0 N2% = 0 Gravity = 1.000 Temp. Base = 60 Pressure Base = 14.73 Barometric Press = 14.73 Diff Range = 100 Static Range = 100 Temp Range = 150 Meter Tube Material = Carbon Steel Orifice Material = 304 or 316 Stainless Chart Type = Linear Note results: Volume MCF 0.214 MCF CPrime 219.098 Fb 210.194 1 Hour.2191 24 = 5.2584 (24 Hour) The results are almost all the same because they have been reduced to near base values, i.e. almost non-dynamic. F pv Supercompressibility factor: Pressure compensation for molecular interaction of a natural gas mixture as pressure increases. β Beta Ratio = Ratio of orifice diameter to upstream pipe inside diameter.e.g. 0.500 orifice divided by 4.026 i.d. meter tube equals a 0.124 beta ratio. F gr Specific gravity factor: The Basic Orifice Factor value was determined with air flowing at 60 o F. The Specific Gravity Factor adjusts for gravity deviation from the gravity of air which equals 1.000. Specific Gravity of a gas is its Relative Density as compared to air. F tf Flowing temperature factor: The Basic Orifice Factor is for air flowing at 60 o F. The flowing temperature factor adjusts for temperature deviation from 60 o F. Page 10

Factors (Glossary continued) F r Reynolds number factor: Corrects for effects of viscosity and velocity F tb Temperature base factor: In the United States most gas is marketed at a temperature base of 60 o F. The base is 60 o F and the factor corrects for deviation from 60 o F. Y Expansion factor: When a gas flows through an orifice, the change in velocity and pressure is accompanied by a change in specific weight. A factor is required to correct for effects [As stated in ANSI/API 2530]. F pb Pressure base factor: In the United States most natural gas is marketed at a pressure base of 14.65 or 14.73 PSI per cubic foot. Calculation is performed using 14.73, the factor corrects for deviation from 14.73. Factors included in C which are listed below are not shown on the AGA 5.0 Factor page F m Manometer factor and F l Gage location factor: Adjustment for using recording mercury manometer for differential pressure unit. Not calculated or used in DRS AGA 5.0. F a Orifice thermal expansion factor: Introduced to correct for the error resulting from expansion or contraction of the orifice operating at temperatures appreciably different from the temperature at which the orifice was bored [As stated in ANSI/API 2530]. Page 11

Special Features Volume to Plate (Backward calculation algorithm) Answers the question, What plate size is needed to increase the volume to X MCF? Holds DP as constant as posible and calculates the new plate size for a new volume limited by the DP range and other constants except plate size. Gives new plate size and corresponding DP if over range occurs. Select the fourth from left icon on the toolbar. Enter desired target DP up to 80% of DP range, then perform calculation. If DP result is greater than 80%, then the next larger orifice plate size is automatically selected with the new target DP being 50% of DP range. Volume to Differential (Backward calculation algorithm) Answers the question, What would the diferential reading be if the flow rate was increased to X MCF? Allows you to calculate the new "what if?" differential pressure upon change of volume, limited by the existing meter tube and orifice size. Holds orifice plate at existing diameter and calculates new DP for entered volume (Calculates resulting DP in inches of water but not in percent or roots. Does not consider DP range.) Select the fifth from left icon on the toolbar. Enter desired target volume to calculate the resulting DP reading. Page 12

Data Files Default File Name. The last file used automatically becomes the Default start up file. After creating a Standard Default file, the file can be created from the File menu: Open a Record to choose a standard company default file. File Name length maximum is 25 characters, extra characters are truncated. A record for each meter or instance can be stored if careful file naming is used. Individual records are stored in a dbase format file. No calculated results are stored. Printing of Data Sheet Report Report Print View: Zoom in and out by pressing left and right mouse buttons. Printer Setup: Prints to the Windows default printer without choice. Page 13

Application Notes Electronic Flow Computers EFM s have the ability to turn of factors in calculations.use Linear for the Chart Type on the Constants page. Ranges must be set to the actual range or greater. Chart Recorders Chart recorders may have different chart types. Chart Type settings are found on the Constants page. (purchase of manual or software required to view) Page 14

Volume Statements Volume statements sometimes roll several factors together or show very little information to help audit the transaction. Sometimes it is uncertain which factors have been used to produce a particular value. Tests must be performed upon empirical values by backing out factors to uncover remaining values to discover how the end result was calculated. Trial and error must be undertaken in order to solve for these unknown values. Then it is necessary to determine what factors the remaining unknown values represent. The Factors page is helpful in determining if certain legal and contractual factors were included in the stated volume or energy value. Sometimes a cal to the company who published the Gas Volume Statement is necessary to find out what has been rolled into a combined factor. Orifice Well Tester see page 6 Over-ranged Differential Pressures see page 6 Vacuum Systems see page 5 Page 15

Field Volume Calculation Methods for Linear, Roots (L-10), Percentage (purchase of manual or software required to view) Page 16

Calculating Coefficients for Field Spot Readings with a Calculator There have been many misunderstandings between purchaser and seller due to the lack of understanding of what a field coefficient actually represents when used in the field with a regular hand calculator, this can be a real source of confusion. Developing a consistent way of calculating a field coefficient for use in field calculations should remedy the situation at least, in part. Coefficients may need to be as generic as possible or generally adapted to a company snormal operations in order to give a fairly accurate but generic coefficient. There is really no way to calculate a coefficient that is dynamic and always accurate as opposed to a virtually non-dynamic generic coefficient which would not be accurate in most cases. Example of how to develop a Standard Default coefficient for general operations: Standard Default : i.e. A setup which takes minimum changes to arive at an accurate volume, as indicated in bold type below. Differential = 5 Roots Static = 5 Roots Temperature = 6.32 (60 o F) Tube Size = 2.067 Orifice Size = 1.000 Hours = 24 CO2% = 0 N2% = 0 Gravity = 0.6 Temp. Base = 60 Pressure Base = 14.65 Barometric Press = 14.4 Diff Range = 100 Static Range = 100 Temp Range = 150 Meter Tube Material = Carbon Steel Orifice Material = 304 or 316 Stainless Chart Type = Roots(L-10) Page 17

Noted Errors in Report Printing Constants: BTU, units are expressed in /Cubic Feet, should be /Cubic Foot. Factors: The term "Beta Factor" should read "Fb Factor" or "Basic Orifice Factor". References Gas Processors Association - GPA Engineering Data Book, 9 th edition, 1972. ANSI/API 2530 First Edition,1978 - American Gas Association, Report #3 American National Standard Institute ANSI/API 2530 American Petroleum Institute API 2530 Support Data Resource Systems, LLC 2919 Highway 75 Wetumka, OK 74883 Phone 405-379-7261 Fax 405-379-3103 e-mail: steve@hughesmeasurement.com Page 18