SetPoint 500 Series Controllers User Manual

Similar documents
Aurora UPC ZS Zone Sensors User Guide

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

ACONT900AC43UA Communicating, Programmable Comfort Control

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

STERILIZERS, LABORATORY DRYING OVENS

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information

Carrier Thermostat Quick Reference Guide

AIR CONDITIONER WALL CONTROLLER

UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

System Manager/Zone Coordinator User s Guide

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

Chronotherm III for Comfort and Convenience

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Operation Guide 3M-22

Operation manual. Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA. Operation manual Daikin Altherma hybrid heat pump.

Drayton Digistat +2RF

EK908FHL - Thermostat for floor heating

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Chapter 2 System Basics

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

LP Series Lighting Control Panel Programming Instructions

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Mode Switch. Fan Switch Menu button Program button

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

Wireless Thermostats 230v and Battery Operated Instruction Manual

Home Screen...4. Quick Start Guide...5. MyAir Standalone Zone Controls only...5. MyAir Zone Controls With Integrated Unit On/Off Control...

Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil

T8131C, T8132C Programmable Thermostat

POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE

1 For All Non-Programmable Digital Thermostat

TC --- PHP, TC --- PAC Comfort Series Programmable Thermostat. Owner s Manual

User manual. 086U6297 Rev. 9 EN

Sensi TM. Wi-Fi Programmable Thermostat SCHEDULING GUIDE. Version: March Emerson Electric Co. All rights reserved.

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP

CT3200 Programmable Thermostat

HEAT HEAT COOL HEAT PUMP COOL

Using Time-of-Day Scheduling To Save Energy

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.

Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT

Home Monitoring and Control service provided by Verizon Online LLC

Drayton Digistat +2RF/+3RF

EasyStart R + Operating instructions. Comfort radio remote control with integrated timer for parking heaters and more.

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

User manual. Solid (FR 98,),

Digital 2 Channel Time Clock EFFECTIVE: 1ST APRIL User Guide PB2CTC

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

User Guide. VisionPRO Wi-Fi Programmable Thermostat. Model TH8320WF

Setup guide for ebanking

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Installation Instructions

BASIC PROGRAMMING GUIDE

SINCE AUTO SAVER 550. OwnerÕs Manual Model 44550

HEAT PUMP PROGRAMMABLE THERMOSTAT

For People With Diabetes. Blood Sugar Diary

OPERATING & MAINTENANCE MANUAL. Packaged Terminal Air Conditioner (PTAC) World Class Comfort.

HOMEOWNER S MANUAL. icomfort Wi Fi Thermostat CONTROLS /12. General. Touch Screen Programmable Communicating Thermostat

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

User's Guide. Pinless Moisture Meter. Model MO257

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Recorder. Controlling Live TV. Control a Live Program You Are Watching

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

User s Guide EKT-824

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction

Midco SmartHOME. Professionally Monitored Service: User Guide. Touchscreen Key Fob Keychain Remote Web Access Device Access for ios and Android

YOUR CONTROL PANEL PANEL

Operation 8022C. Customer Support: or Visit our webiste Made In China OFF FAN HEAT COOL AUTO ON

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

MicroTech Remote Monitoring and Control Panel

EL71 - Single Channel & EL72 - Two Channel Electronic Time Controls General Instructions

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

REMOTE CONTROL MANUAL

GE Total Lighting Control

PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL

Instruction manual for Firstline FCS12000CH

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

After-hours Conditioned Air Policy Revised 8/2/11

TC-9102 Series Surface Mount Temperature Controllers

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

QUICK REFERENCE. Wired remote controller BRC2E52C7 BRC3E52C7

Introduction. to the. QNX Smart Energy Reference

ES-LCD User Control SD Card Location

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

RCS-TM80BG. Contents 4. Weekly Program Function... EG-6 5. Outing Function... EG Sleeping Function... EG-14 XXX XXXX XXXX XXXX XXXX

1F Day 5/1/1 Day Non-Programmable. Yes

Single Zone LCD Thermostat Operating Instructions

Installation Instructions

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

W8735B Telephone Access Module

Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)

BEDIENUNGSANLEITUNG Tieftemperaturheizkörper. MANUAL Low temperature radiator. NOTICE D UTILISATION E2 Radiateur basse température

INSTALLER S & OWNER S MANUAL

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Transcription:

RADIANT HEATING SYSTEMS SETPOINT 500 SERIES CONTROLLERS USER MANUAL SetPoint500UserManual_3-07, Copyright 2007 Uponor, Printed in the United States Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 Tel: (800) 321-4739 Fax: (952) 891-1409 Web: www.uponor-usa.com E-mail: learnmore@uponor-usa.com Uponor Ltd. 655 Park Street Regina, SK S4N 5N1 Tel: (888) 994-7726 Fax: (800) 638-9517 Web: www.uponor.ca E-mail: info@uponor.ca SetPoint 500 Series Controllers User Manual

Table of Contents SetPoint 501, SetPoint 501s, SetPoint 511s and SetPoint 512 Introduction.............................................. 1 Display Symbols........................................... 2 Viewing the Current Temperature............................. 2 Setting the Display........................................ 3 Setting the Temperature (501 and 501s)........................ 3 Setting the Temperature (511 and 512)......................... 3 Setting the Time and Day (511s and 512 Only).................. 3 Setting the Schedule (511s and 512 Only)...................... 4 Overriding the Schedule.................................... 4 Display Lighting (511s and 512 Only).......................... 6 Setting the Units of Temperature.............................. 6 Setting the Mode of Operation............................... 7 Schedule Tables........................................... 8 SetPoint 500 Series Controllers User Manual Published by Uponor, Inc. 5925 148th Street West Apple Valley, MN 55124 (800) 321-4739 www.uponor-usa.com 2007 Uponor, Inc. All rights reserved Second Edition, March 2007 First Printing, May 2005 Printed in the United States of America SetPoint 500 Series Controllers User Manual i

SetPoint 501, SetPoint 501s, SetPoint 511s and SetPoint 512 Introduction Thank you for choosing an Uponor SetPoint 500 Series Controller. These controllers are designed with state-of-the-art technology and packaged in a compact and attractive enclosure. The large display and selection buttons make the controllers extremely user friendly. They are designed to increase the comfort level of your home, as well as increase the energy efficiency of your heating or cooling system. The SetPoint 500 Series Controllers have a display that contains four fields: Menu, Item, Status and Number. The controllers also feature four buttons on the keypad: Menu, Item, Up Arrow (v) and Down Arrow ( ). v Menu Field Displays the current menu Item Field Displays an abbreviated name of the selected item Status Field Displays the current status of the thermostat s inputs, outputs and operation Buttons Selects menus, items and adjusts settings Number Field Displays the current value of the selected item ii SetPoint 500 Series Controllers User Manual 1

Display Symbols Warning Displays when an error exists Access Level (501s, 511s and 512 Only) Displays when in the User Access Level Early Start (511s and 512 Only) Displays when in Early Start Heat 1 Displays when the Heat 1 contact is on Heat 2 (512 Only) Displays when the Heat 2 contact is on Cool 1 (512 Only) Displays when the Cool 1 contact is on Viewing the Current Temperature (501s, 511s and 512 Only) The View menu displays the current temperature sensed by the controller and its auxiliary sensor. To view the various temperatures, begin by selecting the View menu using the Menu button. Then use the Item button to view the available temperatures. Room This is the current air temperature of the room that is being controlled. At least one air sensor must be active for this temperature to be displayed. Outdoor This is the current outdoor air temperature. This is only available if the auxiliary sensor is set to sense the outdoor air temperature. Slab This is the current slab or floor temperature. This is only available if the auxiliary sensor is set to sense the slab or floor temperature. Setting the Display The 511s and 512 controllers allow the user to change the display to show either the current time or any of the settings from the View menu. Follow the steps below to select which setting is displayed. 1. Press the Menu button to select the Time if you want the time to display. 2. Press the Menu button again to select the View menu. 3. Once in the View menu, use the Item button to select the desired item to display. Setting the Temperature (501 and 501s) To set the desired temperature, simply press the up or down arrow buttons to adjust the temperature. Note: The Adjust menu automatically appears. Setting the Temperature (511 and 512) Follow the steps below to set the desired air and slab or floor temperatures. Note: Slab or floor temperatures are only available when a slab or floor sensor is used. 1. Press and release the Menu button until the Adjust menu displays. 2. Press and release the Item button until the desired event displays (Wake, UnOcc, Occ and Sleep). 3. Use the up or down arrow buttons to set the desired temperature. Record the temperature in the schedule tables found on pages 8 and 9 for future reference. Repeat steps 2 and 3 for each additional event. Setting the Time and Day (511s and 512 Only) Follow the steps below to set the time and day. 1. Press and release the Menu button until the Time menu displays. 2. Press the Item button to change the minute setting. While the minute field is flashing, use the up or down arrow buttons to set the proper minutes. 3. Press and release the Item button again to change the hour setting. While the hour field is flashing, use the arrow or down arrow buttons to set the proper hour. 2 SetPoint 500 Series Controllers User Manual 3

4. Press and release the Item button again to change the day setting. While the day field is flashing, use the up or down arrow buttons to set the proper day. Setting the Schedule (511s and 512 Only) A schedule allows the controller to automatically change between several preset temperatures based on the time of day. The schedule divides the day into either two or four events. For each event, a different temperature can be set. This allows the room and floor to remain warm during the day and cooler during the evening and night. Note: Refer to the Setting the Time and Day procedure mentioned previously to set the time of day for each event to begin. 1. Press and release the Menu button until the Schedule (SCHD) menu displays. 2. Press and release the Item button. Use the up or down arrow buttons to select the desired schedule mode. (None = one temperature per day; 2 = two temperatures per day; 4 = four temperatures per day) 3. Press and release the Item button again to set the schedule cycle. Use the up or down arrow buttons to select either 7 day or 24 hour. 4. Press and release the Item button again. Use the up or down arrow buttons to set the event's beginning time. If the event does not have a time, select the --:-- time. This time is found between 11:50 p.m. and 12:00 a.m. Record the event time in the schedule tables found on pages 8 and 9 for future reference. Repeat step 4 until all events are programmed. Overriding the Schedule Temporary Override (511s and 512 Only) Follow the steps below to temporarily override the schedule. Note: A temporary override lasts for three hours and does not permanently change the existing schedule. 1. Press and release the Menu button until the View menu displays. 3. Press and release either the up or down arrow buttons once. 4. Use the Item button to select between the heating temperature and the cooling temperature (512 only). 5. Press the up arrow button to increase the temperature to the desired setting and use the down arrow to decrease the temperature to the desired setting. A three-hour temporary override is now in effect. Canceling a Temporary Override To cancel a temporary override, press the Menu button once or twice if the backlight is not lit. Permanent Override (511s and 512 Only) Follow the steps below to permanently override the schedule. Note: A permanent override stays in effect until a new override is selected. A permanent override does not change the existing schedule. 1. Press and release the Menu button until the Schedule (SCHD) menu displays. 2. Use the up or down arrow buttons to select the desired permanent override. Canceling a Permanent Override Follow the steps below to cancel a permanent override. 1. Press and release the Menu button until the Schedule (SCHD) menu displays. 2. Use the up or down arrow buttons to select the None setting. Away Override (501s, 511s and 512 Only) An away override is a quick override that does not change the existing temperature settings. Use the away override during long periods of absence. When the away override is selected, the heating temperature is automatically set to 62 F (16.5 C) and the cooling temperature (for the 512 in Heat/Cool mode only) is set to 82 F (28 C). If a slab or floor sensor is used with the controller, the minimum slab or floor temperature is also ignored. This operation continues as long as the away override is selected. 2. Press and release the Item button until the Room temperature displays. 4 SetPoint 500 Series Controllers User Manual 5

Follow the steps below to select the away override. 1. Press and release the Menu button until the Schedule (SCHD) menu displays. 2. Use the up or down arrow buttons to select the away override. Canceling the Away Override (501s, 511s and 512 Only) Follow the steps below to cancel the away override. 1. Press and release the Menu button until the Schedule (SCHD) menu displays. 2. Use the up or down arrow buttons to select the None setting. Display Lighting (511s and 512 Only) The display on the controller has a backlight setting. The backlighting can be turned on, turned off or set to operate temporarily for 60 seconds after any button is pressed. Follow the steps below to set the display lighting. 1. Press and release the Menu button until the Adjust menu displays. 2. Press and release the Item button until the word LITE displays. 3. Use the up or down arrow buttons to select On, Tmpy (temporary) On or Off. Note: If the backlight setting is temporary, the first press of a button turns on the backlight. Setting the Units of Temperature Follow the steps below to select between Fahrenheit and Celsius. 1. Press and release the Menu button until the Adjust menu displays. Setting the Mode of Operation There are several modes of operation available depending on the type of controller installed and its setup. Follow the steps below to select the mode of operation. 1. Press and release the Menu button until the Adjust menu displays. 2. Use the up or down arrow buttons to select between the Off, Heat, Cool (512 only) and Auto (512 only) settings. Off In the Off mode, the controller does not operate the heating device. Heat In the Heat mode, the controller operates to maintain the room at the required heating temperature. Cool This mode is only available with the SetPoint 512 that is set up for heating and cooling. In the cool mode, the SetPoint 512 operates to maintain the room at the required cooling temperature and ensures that the heating does not turn on. Auto This mode is only available with the Setpoint 512 that has been set up for heating and cooling. This mode allows the SetPoint 512 to automatically switch between heating and cooling the room as the air temperature requires. If a slab or floor sensor is installed, the floor maintains the minimum slab or floor temperature even during cooling. 2. Press and release the Item button until the current temperature unit begins to flash. 3. Use the up or down arrow buttons to select between Fahrenheit and Celsius. 6 SetPoint 500 Series Controllers User Manual 7

8 SetPoint 500 Series Controllers User Manual Schedule Tables Two-Event User Program Slab 24-hour Event Heat Cool Min. Schedule Sun Mon Tues Wed Thur Fri Sat Occ 70 F 78 F 70 F (21.0 C) (25.5 C) (21.0 C) 6:00 AM UnOcc 62 F 82 F (16.5 C) (28.0 C) OFF 10:00 PM Four-Event User Program Slab 24-hour Event Heat Cool Min. Schedule Sun Mon Tues Wed Thur Fri Sat Wake 70 F 78 F 70 F (21.0 C) (25.5 C) (21.0 C) UnOcc 62 F 85 F (16.5 C) (29.5 C) OFF Occ 70 F 78 F 70 F (21.0 C) (25.5 C) (21.0 C) Sleep 62 F 82 F (16.5 C) (28.0 C) Two-Event User Program OFF Slab 24-hour Event Heat Cool Min. Schedule Sun Mon Tues Wed Thur Fri Sat Occ 70 F (21.0 C) 78 F (25.5 C) 70 F (21.0 C) 6:00 AM UnOcc 62 F (16.5 C) 82 F (28.0 C) OFF 10:00 PM Four-Event User Program Slab 24-hour Event Heat Cool Min. Schedule Sun Mon Tues Wed Thur Fri Sat Wake 70 F 78 F 70 F (21.0 C) (25.5 C) (21.0 C) UnOcc 62 F 85 F (16.5 C) (29.5 C) OFF Occ 70 F 78 F 70 F (21.0 C) (25.5 C) (21.0 C) Sleep 62 F 82 F (16.5 C) (28.0 C) OFF 9