TENERGY AA 1000mAh NiCd Battery

Similar documents
NI-ZN BATTERY SPECIFICATION

EVERGREEN (C.P.) USA INC. TEL: (650) FAX: (650) SPECIFICATIONS Lithium Battery CR123A- 1700mAh

LITHIUM BATTERY CR123A SPECIFICATION

Spec. No. ICR C Version No. 0.0

Lithium Ion Battery Specifications

1. Scope This specification is applied to ICR Product Specification Table 1 No. Item Rated Performance Remark

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

Li-ion Rechargeable Battery. Specification

Specification. Li-ion Rechargeable Battery

li-ion Polymer Battery Specification

LI-POLYMER BATTERY PACKS. Specification. Type: mAh. Prepared/Date Auditing/Date Approved/Date WANG MAR 16, 2006 LI MAR 16, 2006

Li-Polymer Battery Technology Specification

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Title Li-ion Battery Specifications (Steel) Page 1/11

DELIVERY SPECIFICATIONS

Superior Lithium Polymer Battery

Li-ion Polymer Battery Specification

Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal

Specification Approval Sheet

BAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH

Product Specification

PRODUCT SPECIFICATION

CappController Pipette Controller. Operation Manual Version:

A23 TECHNICAL SPECIFICATION FOR ALKALINE MANGANESE DIOXIDE BATTERY DATE : 21/8/2003

PRODUCT SAFETY DATA SHEET

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

Handbook. We aim to bequeath a beautiful Earth for our future generations.

12 Volt 30 Amp Digital Solar Charge Controller

User s Manual AURORA 1.2K/2.2K

PRODUCT SAFETY DATA SHEET

Torfino Enterprises, Inc.

How To Use A Power Supply Unit (Upu)

Mini Power Bank and Charger

3 WATT LED SPOTLIGHT Model No. SLM

Product Specification

Product Title Abstract

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

BUB-110B. Portable Power Pack. Compact USB Battery Charger for up to 5 Smartphones and Mobile Devices. User Manual

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Product Specification

TRANSPORT OF DANGEROUS GOODS

Carefree Sealed Lead Acid (SLA) MSDS

Product Specification

INSTALLATION AND OPERATION MANUAL. Batteries for electric drive of bikes EVBAT48V9A-R EVBAT36V13A-R

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Li Battery Pack & Charger Safety & Operating Instructions

NFC Communication Tray Model: HHX-IT3-Z

2013 VTech Printed in China US

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Lithium-Polymer Battery

Standard Operating Procedure (SOP) Car/Truck Battery Safety

Safety data sheet for product

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

MATERIAL SAFETY DATA SHEET

Height w/o Terminals (in)

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

400 Amp Rechargeable Jump Start System RAC-HP082

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

TELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

Single Phase Soft Starter

Height w/o Terminals (in)

Fabric Sensor Evaluation Kit Information Sheet

Mini-led spotlight with magnetic base

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

POWER TO GET THE JOB DONE

CELO5. User & Installation Manual.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

How To Safely Use A Lithium Ion Cell

Quick Start Guide Vodafone Business Connect

BATTERY CHARGER OWNER S MANUAL

Material Safety Data Sheet

BroadBand PowerShield. User Manual

Lithium-ion Battery Specification

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Threaded Inline Air Heaters

Important Safety Instructions

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

CL90i Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser

Infrarot-Bewegungsmelder IP44

Primary lithium battery LST 14250

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

LG Wireless Remote Controller

Lithium-Ion Battery SPECIFICATION

Product Specification

How To Use A Cdm250 Digital Multimeter

Copyright. Trademarks

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

International English

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

MSDS FOR RECHARGEABLE LITHIUM-ION BATTERIES

SHENZHEN PKCELL BATTERY CO., LTD. Li-Polymer Battery Technology Specification

Electrical Double Layer Energy Storage Capacitors Power and Energy Versions

12V/15.0A SLA Battery Charger Specification

PRODUCT INFORMATION AND DATA SHEET

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

Transcription:

TENERGY AA 1000mAh NiCd Battery Product Name: Tenergy NiCd AA Product Number: 20102 Battery Model: NiCd AA 1000mAh Battery Chemistry: Nickel Cadmium Diameter (D): 14.5 mm Dimension: Button Height (H): 50.5 mm Button Diameter (d): 4.75 mm 1. SCOPE The specification describes the technology parameters and testing standard for the NiCd AA size cells supplied by TENERGY CORPORATION. 2. CHARACTERISTICS 2-1.Nominal Voltage 1.2V 2-2.Typical Capacity* 1 1000mAh 2-3.Minimum Capacity* 1 800mAh 2-4.Charging Current* 2 900mAh Page 1 of 9

2-5.Charging Time* 2 Tenergy Corporation Approx.72 min 2-6.End Voltage of Discharge 1.0V 2-7.Temperature(Recommended) Charge: Discharge: Storage: Less than 30 days Less than 90 days Less than 1 year 0~+40deg.C 0~+50deg.C -20~+50deg.C -20~+40deg.C -20~+30deg.C 2-8.Humidity 45~85% 2-9.Impedance 2-10.Weight *1: Discharge capacity when the battery pack is discharged at 160 ma after being charged at 80 ma for 16 hours. *2: Use recommended charging systems. <30mohm (after charge) Approx. 20g 3. APPEARANCE There shall be no practical damage such as conspicuous liquid electrolyte leakage, flow and dirt under conditions of storage or operation as specified herein. 4. ELECTRICAL CHARACTERISTICS 4-1.Full-charge Full-charge is defined as charged up to fully charged state using a specified fast charger. The specified fast charger is as follows. Charging Current: 80mA Full charge detection: Peak Voltage 4-2.Terminal voltage(o.c.v) Page 2 of 9

Open circuit voltage shall be a minimum voltage of 1.30V within 14 days after being fully charged. 4-3.Capacity 4-3-1. The battery unit shall be capable of supplying 80mA continuous discharge current for a minimum of 280 minutes to 1.0V end voltage within 1 hour after being fully charged. 4-3-2. The battery unit shall be capable of supplying 400mA continuous discharge current for a minimum of 108 minutes to 1.0V end voltage within 1 hour after being fully charged. 4-3-3. The battery unit shall be capable of supplying 800mA continuous discharge current for a minimum of 54 minutes to 1.0V end voltage within 1 hour after following process. Charge with 80 ma for 16 hours after discharged with 160 ma to 1.0V. Remarks: Item 4-3-3.is applied only for the capacity measurement. Please do not use item 4-3-3.for the design of the charger. 4-4. Internal Impedance After the battery unit is fully charged, within 1~4 hour(s), the internal impedance is not greater than 30m, as tested by 1000Hz AC source. 4-5.Cycle Life The battery unit shall be capable of 200 minimum cycles under the conditions as follows (The ambient temperature is 18~22 deg.c). Charge :Paragraph 4-1 Rest :1 hour Discharge :Paragraph 4-3-2 Rest :1 hour Page 3 of 9

After 200 cycles, discharge time as specified in paragraph 4-3-2 shall be a minimum of 72 minutes. 4-6.Over-discharge Fully charged battery unit, when discharged with 10 ohm load for 8 hours, shall not cause damage, leakage, salting or degradation in performance characteristics as specified herein. 4-7.Temperature Characteristics 4-7-1. Within 1 hour after fully charged at 40 deg.c, discharge time shall be a minimum of 84 minutes at 20 deg.c as specified in paragraph 4-3-2. 4-7-2. Within 1 hour after fully charged at 20 deg.c, discharge time shall be a minimum of 84 minutes at 0 deg.c as specified in paragraph 4-3-2. 4-8.Self-discharge 4-8-1. After fully charged unit is stored for 30 days at 20 deg.c, discharge time shall be a minimum of 72 minutes as specified in paragraph 4-3-2. 4-8-2. After fully charged unit is stored for 7 days at 40 deg.c, discharge time shall be a minimum of 72 minutes as specified in paragraph 4-3-2. 4-9.Safety 4-9-1. The battery unit shall not explode when it is charged at 80 ma for 5 hours. However, it is acceptable for the battery unit to sustain leakage of battery fluid and show a change in appearance. Page 4 of 9

4-10.Vibration The battery unit shall not sustain damage to its battery performance, when it is tested under the following conditions. Conditions: Amplitude ---4mm Cycle Direction Time ---16.7Hz ---Three directions(x,y,z) ---60 minutes 4-11.Supply The battery unit shall be shipped at charged state. 5. ENVIRONMENTAL PROTECTION REQUIREMENT 5-1. The requirement on Hazardous Substances in the Products should comply with 2006/66/EC and TENERGY s criterion on HS. 6. TRANSPORT 6-1. To ensure battery safety during delivery, SOC (State Of Charge) must be below 35%, inside temperature of container could not be over 35. Product holder should be responsible for any possible loss during delivery if above conditions cannot be met completely. 6-2. Inside temperature of container must be below 20 if any client requires SOC (State Of Charge) above 35%, the distance between battery master cartons should be not less than 10cm in container, and coercive air cross ventilation system is required in container to ensure even temperature for each master carton. Product holder should be responsible for any possibly accidental loss if above conditions cannot be met completely. 7. PRECAUTION: Please keep in mind the following points when designing and manufacturing equipment. Please insert in your instruction manual. To prevent equipment malfunctions from affecting the batteries, be sure to use protection devices for electrical circuits and Page 5 of 9

batteries.! Danger! Failure to carefully observe the following procedures and precautions can result in leakage of battery fluid (electrolyte), heat generation, explosion, fire and serious personal injury! Never dispose of TENERGY batteries in a fire or heat them. Do not connect the (+) positive and (-) negative terminals of TENERGY batteries together with electrically conductive materials, including lead wires. Do not transport or store TENERGY batteries with their uncovered terminals or connected with a metal necklace or other electrically conductive material. When carrying or storing batteries, use a special case. Only charge TENERGY batteries using those specific chargers that satisfy TENERGY s specifications. Only charge batteries under the conditions specified by TENERGY. Never disassemble TENERGY batteries. Doing so may cause an internal or external short circuit or result in exposed material of battery reacting chemically with the air. It may also cause heat generation, explosion and fire. Also, this is dangerous as it may cause splashing of alkaline fluid. Never solder lead wires directly on to TENERGY batteries. The (+) positive and (-) negative terminals of TENERGY batteries are predetermined. Do not force the terminals to connect to a charger or equipment. If the terminals cannot be easily connected to the charger or the equipment, check if the (+) and (-) terminals are incorrectly positioned. The gas release vent which release internal gas is located in the (+) positive terminal of the TENERGY battery. For this reason, never deform this section or cover or obstruct its gas release structure. Do not directly connect TENERGY batteries to a direct power source or the cigarette lighter socket in a car. TENERGY batteries contain a strong colorless alkaline solution (electrolyte). The alkaline solution is extremely corrosive and will cause skin damage. If any fluid from a TENERGY battery comes in contact with user s eyes, they should immediately flush their eyes and wash them thoroughly with clean water from the tap or another source and consult a doctor Page 6 of 9

urgently. The strong alkaline solution can damage eyes and lead to permanent loss of eyesight. When TENERGY batteries are to be incorporated in equipment or housed within a case, avoid air-tight structures, as this may lead to the equipment or the case being damaged or may be harmful to users. 8. WARRANTY TENERGY will be responsible for replacing the battery against any defects or poor workmanship for six months from the date of shipping. Any other problems caused by malfunction of the equipment or misuse of the battery are not under this warranty. Notice: To assure safety, please consult to the TENERGY technical staff for your applications including electrical specifications, mechanical designs, protective devices and any special specification. TENERGY reserve the right to alter or amend the design, model and specification without prior notice. Page 7 of 9

Appendix: Performance Curve Page 8 of 9

Page 9 of 9