Developing a Natural Ventilation Model for Open-Roof Greenhouses

Similar documents
Glazing Materials, Structural Design, and Other Factors Affecting Light Transmission in Greenhouses

Greenhouse Glazing Effects on Heat Transfer for Winter Heating and Summer Cooling

Some Thoughts on Supplemental Lighting for Greenhouse Crop Production

1. Theoretical background

Decision Support System for single truss tomato production

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

American Society of Agricultural and Biological Engineers

SOLAR RADIATION AVAILABILITY FOR PLANT GROWTH IN ARIZONA CONTROLLED ENVIRONMENT AGRICULTURE SYSTEMS

Saving Heating Costs In Warehouses

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Greenhouse Cooling. Why is Cooling Needed?

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

Fan and Pad Greenhouse Evaporative Cooling Systems 1

Calculation of Liquefied Natural Gas (LNG) Burning Rates

CHAPTER 5 Lectures 10 & 11 Air Temperature and Air Temperature Cycles

CHAPTER 2 Energy and Earth

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Solar and Wind Energy for Greenhouses. A.J. Both 1 and Tom Manning 2

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Experimental Evaluation Of The Frost Formation

AGRICULTURAL COVERING

Software Development for Cooling Load Estimation by CLTD Method

Influence of Solar Radiation Models in the Calibration of Building Simulation Models

World Water and Climate Atlas

Business Planning for a Greenhouse Operation. Joyce Latimer, Virginia Cooperative Extension

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Accurate Air Flow Measurement in Electronics Cooling

Seasonal & Daily Temperatures. Seasons & Sun's Distance. Solstice & Equinox. Seasons & Solar Intensity

LIFE SCIENCE. Hoop House Construction for New Mexico: 12-ft. x 40-ft. Hoop House BRINGING TO YOUR HOME ECONOMICS COLLEGE OF AGRICULTURE AND

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Energy Pathways in Earth s Atmosphere

How do I measure the amount of water vapor in the air?

EXPLANATION OF WEATHER ELEMENTS AND VARIABLES FOR THE DAVIS VANTAGE PRO 2 MIDSTREAM WEATHER STATION

Evaporative Cooling System for Aquacultural Production 1

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

THERMAL STRATIFICATION IN A HOT WATER TANK ESTABLISHED BY HEAT LOSS FROM THE TANK

Optimizing the hydraulic designing of pressurized irrigation network on the lands of village Era by using the computerized model WaterGems

Page 1. Weather Unit Exam Pre-Test Questions

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

PERFORMANCE EVALUATION OF SOLAR ENERGY DEVICES BY USING A DATA LOGGING SYSTEM

Energy Efficient Building Design College of Architecture Illinois Institute of Technology, Chicago. Ceiling/Airspace

Housing Fact Sheets. Moisture Condensation at the Windows

Creating a Master Plan for Greenhouse Operations

CHAPTER 3 Window design for day lighting, ventilation and to

Undergraduate Degree Turfgrass Management

Lecture No Active summer cooling systems Fan-and Pad cooling system Fog cooling system

FACTSHEET Assessing the Feasibility of Using Solar-Thermal Systems for Your Agricultural or Agri-Food Operation

PROTOCOL FOR BUILDING ENERGY ANALYSIS SOFTWARE For Class 3, 5, 6, 7, 8 and 9 buildings

The Influence of Insulation Styles on the Air Conditioning Load of Japanese Multi- Family Residences

Absolute and Relative Gas Concentration: Understanding Oxygen in Air

CONDENSATION IN REFRIDGERATED BUILDINGS

Opening the Bonnet. Prof Darren Woolf WYSINWYG 1

RESNET National Rater Test Study Guide Outline

Design and Re-Use Of Shovadans In Today's Architecture "With Due Attention To Have Thermal Energy Of The Earth"

3 i Window Films. 3 Proof of Technology Experiment Cover Letter

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

Comparing Energy Savings of Different VAV Systems

CAN DEMAND CONTROLLED VENTILATION REPLACE SPACE HEATING IN OFFICE BUILDINGS WITH LOW HEATING DEMAND?

Energy efficient home design

Fundamentals of Climate Change (PCC 587): Water Vapor

Microclimate and Energy Consumption in Commercial, Hot-Water and Steam Heated Greenhouses for Tomato Production

Performance Estimation of Water Thermal Energy Storage Tank by Using Simplified Simulation

Federation of European Heating, Ventilation and Air-conditioning Associations

ebb current, the velocity alternately increasing and decreasing without coming to

Integration of a fin experiment into the undergraduate heat transfer laboratory

Analytical Test Method Validation Report Template

Adaptive strategies for office spaces in the UK climate

Owned and operated by Ontario farmers

IntelliGrow - a new climate control concept

BRSP-7 Page 1. A Open B Covered C Covered / Water. Two different experiments are presented, each experiment using a different pair of models:

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

HVAC Calculations and Duct Sizing

Cool Spaces. earth-wise guide to. green strategies: light strategies: Keep Austin Cool

The Watergy greenhouse: Improved productivity and water use efficiency using a closed greenhouse

Requirements and technology for smart materials in greenhouses

Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

COTTON WATER RELATIONS

Use of numerical weather forecast predictions in soil moisture modelling

2013 Code_Saturne User Group Meeting. EDF R&D Chatou, France. 9 th April 2013

HAY MOISTURE & WEATHER:

Research Project F W. Richter. Manual of thermal comfort of Summer cooling mode

Application of Building Energy Simulation to Air-conditioning Design

ECONOMICS OF GREENHOUSE PRODUCTION IN ALASKA - USING THE GREENHOUSE AT CHENA HOT SPRING RESORT AS A MODEL

Solar Energy and Green Roofs

ENVIRONMENTAL STRUCTURE AND FUNCTION: CLIMATE SYSTEM Vol. II - Low-Latitude Climate Zones and Climate Types - E.I. Khlebnikova

Refractive Index Measurement Principle

Energy Consumption and Air Quality in Growing-Finishing Pig Houses for Three Climate Regions Using CIGR 2002 Heat Production Equations

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

Mixing Valves. ARGUS Application Note: Mixing Valves

MODELLING COUPLED HEAT AND AIR FLOW: PING-PONG VS ONIONS

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

Thermal environment in indoor spaces with under-floor air distribution systems: 1. Impact of design parameters (1522-RP)

SENSITIVITY STUDY FOR ARCHITECTURAL DESIGN STRATEGIES OF OFFICE BUILDINGS IN CENTRAL CHILE: EFFECTIVENESS OF NOCTURNAL VENTILATION.

The Three Heat Transfer Modes in Reflow Soldering

Light in the Greenhouse: How Much is Enough?

CFD Beyond the Whitespace. Datacentres Central & Eastern Europe

Transcription:

Developing a Natural Ventilation Model for Open-Roof Greenhouses July S. Sase, Lead Scientist Laboratory of Controlled Environment Agriculture, National Institute for Rural Engineering, Japan E. Reiss, Program Associate A.J. Both, Assistant Extension Specialist W.J. Roberts, Professor Emeritus Bioresource Engineering, Department of Plant Biology and Pathology, Rutgers University, USA Abstract A computer simulation model for natural ventilation in open-roof greenhouses was developed to predict the ventilation performance. The model predicts ventilation rate and the temperature differences between inside and outside, based on the weather and structural conditions including internal net radiation, wind velocity, and height and area of the roof openings. The ventilation rate was calculated from thermal buoyancy and wind forces. A sensible heat balance was incorporated to calculate the ventilation rate and the temperature difference simultaneously. A four-span open-roof greenhouse with roof sections hinging at the gutters and opening at the ridge, constructed on the Rutgers University campus, was used for data collection. Measurements of climate conditions in the direct vicinity of the greenhouse were conducted. Using the observed outdoor and greenhouse conditions, the model parameters were calibrated statistically. The accuracy of the model and the modifications to the model are discussed by comparing the predicted and observed greenhouse temperatures. It is shown that the internal temperature rise depends on the roof configuration as well as solar radiation and wind velocity. The resulting simulation model can be used to implement new environment control strategies for open-roof greenhouses. Introduction During the last five years, open-roof greenhouse designs have become very popular in the US. Most greenhouse manufacturers in North America sell at least one type of an open-roof greenhouse design. Growers have reported two main advantages of open-roof greenhouses compared with traditional fan ventilated greenhouses: () during warm(er) conditions, the greenhouse temperature closely tracks outside temperatures with little or no energy requirements (to operate the fans), and () spring plants can be easily hardened off by opening the roof. Despite their popularity, little research data is available to support the grower enthusiasm for open-roof greenhouses. In an attempt to study open-roof greenhouse design and operation, a small greenhouse (Van Wingerden Greenhouse Company, Horse Shoe, NC, USA, the MX-II style) was constructed on one of the research farms at Cook College, Rutgers University in New Brunswick, NJ, USA. Because the design of open-roof greenhouses differs significantly from traditional mechanical or natural ventilated greenhouses, it became clear that a study of the ventilation in open-roof greenhouses was warranted. In particular, it is necessary to verify that open-roof greenhouses provide sufficient and uniform air exchange rates between the inside and outside greenhouse environment. In this paper, we have attempted to model the natural ventilation patterns in a small open-roof greenhouse. CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

Weather station. m.9 m.9 m. m. m Figure. Side view of the greenhouse south wall (not to scale). Materials and methods Observation The dimensions of the open-roof greenhouse used for this study are shown in Figures and. The direction of the greenhouse gutters was slightly rotated from the north-south direction ( ) as a result of the location of adjacent roads and buildings. Although the greenhouse was outfitted with additional ventilation openings in the sidewalls (the east and west walls), these sidewall ventilation openings were kept closed during the measurement intervals from which the data was used for the validation of the ventilation model. The greenhouse environment was controlled with a commercial control system (Argus Control Systems, Ltd., White Rock, BC, Canada). The temperature set point for ventilation was C ( F) and the roof position was operated based on the measured temperature at a height of. m ( ft). In some cases, the roof position was kept manually at a constant opening. When the roof sections were fully opened, the ratio of the roof opening area to the greenhouse floor area was.. No crops were grown in the greenhouse during the period of data collection, except for a short period of several days when approximately % of the floor area was filled with potted plants. All measurements were recorded as -minute averages. Outside the greenhouse, a weather station was installed containing sensors to measure outdoor conditions. The.9 m ( ft) mast was equipped with instrumentation to measure the following parameters at a height of.9 m (. ft): temperature, relative humidity, wind speed and direction, and rain detection. In addition, a quantum sensor (LI-COR, Inc., Lincoln, NE, USA) was installed to measure photosynthetically active radiation (PAR, with wavelengths between and nm), as well as a precision pyranometer (The Eppley Laboratory, Inc., Newport, RI, USA) to measure total solar radiation (short wave, with wavelengths between and, nm). CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

Inside the greenhouse, temperature was measured at three different heights:.,., and. m (,, and ft) above the floor. A LI-COR quantum sensor and pyranometer, an Eppley precision pyranometer, and a Micromet net radiometer (Campbell Scientific, Inc., Logan, UT, USA) measuring wavelengths between and, nm were mounted at. m ( ft) above the floor, and positioned underneath one of the roof ridges, to measure radiation conditions inside the greenhouse (Figure ). Prior to the measurements, all radiation sensors were calibrated using the Instrument Package provided by the NCR- Committee on Controlled Environment Technology and Use. Weather station Angle = Post. m Radiation Sensors. m. m Tank Tank. m Door Figure. Greenhouse layout (not to scale). CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

Figure. View of the placement of the radiation sensors inside the greenhouse. Model description The model proposed by Boulard et al. (99) to estimate the natural ventilation rate in greenhouses with only roof openings was used. The model is based on the two driving forces for natural ventilation: thermal buoyancy and wind forces. The model can be written in the following form: G = A o ( a H/ T + a V ) / () where G is the ventilation rate per unit greenhouse floor area (m /m /s), A o is the ratio of roof opening area to the greenhouse floor area, H is the height of the opening above the floor (m), T is the air temperature difference between inside and outside ( C), V is the wind velocity (m/s) at a height of.9 m, a is the buoyancy constant (m /s / C), and a is the wind effect coefficient (dimensionless). The parameters, a and a include the discharge coefficient of the roof opening(s). A typical model for the sensible heat balance was incorporated to calculate the ventilation rate and the temperature difference between inside and outside simultaneously. It is based on a steady state condition and shown as follows: G = ( α R n / T - U β ) / ( C p ρ ) () where G is the ventilation rate per unit greenhouse floor area (m /m /s), α is the ratio of sensible heat gain to the inside net radiation, R n is the inside net radiation (W/m ), U is the overall heat transfer coefficient (W/m / C), β is the ratio of the greenhouse surface area to the greenhouse floor area, C p is the specific heat of air ( J/kg/ C), and ρ is the specific mass of air (kg/m ). Approximately data points collected during the period of March through May,, were used to determine the parameters a and a using least squared residuals between the observed and predicted temperature differences. Prior to the analysis, other necessary CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

parameters were determined or normalized. The sensible heat gain can be related to the evapotranspiration in a greenhouse and varies according to the greenhouse environment in general. During the observation, no crops were grown in the greenhouse and the soil surface condition was mostly dry. The value of α was determined using Equation () when the roof segments were closed. This value gradually decreased from. to. during the time period of the measurements. This is likely due to the fact that weeds started growing inside the greenhouse and due to the time a batch of potted plants covered approximately % of the greenhouse area during the month of May. The observed inside net radiation fluctuated markedly on clear days because of the shadows caused by the construction materials and the light reflection from opened roof surfaces. Such data of net radiation were normalized using the statistical relation between the outside solar radiation and the inside net radiation, and then used as model input data. The U value was assumed to be W/m / C for the experimental greenhouse covered with two layers of air-inflated polyethylene film. The term β for the experimental greenhouse was.. Results and Discussion Using approximately measurements, the parameters, a and a for the height of. m ( ft) were determined to be. and., respectively. They are slightly larger than the parameters (. and., respectively) Kittas et al. (99) determined for a twin-span greenhouse with continuous roof ventilators using the tracer gas method. On the other hand, the determined parameters for the measurement height of. m ( ft) were. and., respectively. They were smaller than those for the height of. m ( ft). This reflects the warmer temperature at the measurement height of. m ( ft) compared to a height of. m ( ft) because of the vertical temperature gradient in the greenhouse. The observed temperature at. m ( ft) was always lower than that at. m ( ft) during the daytime. Figure shows an example of the diurnal changes in predicted and observed temperature differences between inside and outside. Note that the control system operated the position of the roof segments based on the deviation from the measured temperature at a height of. m ( ft) from the temperature set point ( C or F), and to a lesser extent based on the outside temperature and solar radiation. Figure shows that the predicted temperature differences agreed closely with the observed temperature differences at a small opening, while those were overestimated when the roof segments were more widely opened. The temperature difference decreased with an increase in the outside temperature, which peaked in the late afternoon on clear days. When the roof segments were widely opened, the inside temperature, particularly at a height of. m ( ft) occasionally dropped below the outside temperature. This negative temperature difference might be due to cooling caused by evaporation and/or longwave radiation from the greenhouse floor. Furthermore, an outside temperature gradient might exist. Note that the outside temperature was measured at a height of.9 m (. ft). The outside temperature generally decreases with an increase in height above the ground during the daytime. It was assumed that the temperature difference at m (. ft) height above the ground is up to. C (. F) larger than that at.9 m (. ft) height. However, the model described here does not take this into account and is not capable of predicting negative temperature differences. CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

Temperature difference ( C) Observed Predicted Height. m. m. m. m May, -. 9 Ratio of opening area to floor area..... 9 Radiation (W/m ) Wind velocity (m/s) Outside solar radiation Inside net radiation (normalized) 9 9 Time (h) Figure. Comparison of the diurnal changes in predicted and observed temperature differences between inside and outside. The changes in the input parameters used for the model predictions are also illustrated. CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

A comparison of the observed and predicted temperature differences for four ratios of opening area to the floor area is shown in Figure. The standard errors of the temperature differences for the heights of. and. m ( and ft) were. and.9 C (. and. F), respectively. The predicted temperature difference was found to be highly sensitive to the changes in the roof opening and the inside net radiation. This feature seems reasonable since they have linear relations with the ventilation rate as shown in the Equations () and (). Predicted ( C) Measurement height:. m Ratio of opening area to floor area.... Predicted ( C) Measurement height:. m Ratio of opening area to floor area.... - - Observed ( C) - - Observed ( C) Figure. Comparison of observed and predicted temperature differences for four ratios of opening area to the floor area:.,.,. and.. In order to demonstrate the general ventilation characteristics under typical conditions, Figure shows the predicted effects of the opening area and the inside net radiation on the temperature difference and the ventilation rate. The parameters for the height of. m ( ft) were used to predict the environment at crop level. The term α was assumed to be. representing a greenhouse with moderate vegetation. The wind velocity of m/s (9 fpm) was chosen as an expected minimum under normal conditions. The temperature difference decreased rapidly with an increase in the opening area when the ratio of the roof opening area to the floor area was smaller than. to.. At larger opening areas, the slope of the temperature difference curve decreased and the temperature difference was less affected by the opening area. Under these conditions, the temperature difference was almost proportional to the inside net radiation. The ventilation rate showed a linear increase with an increase in the opening area. The predicted effect of the outside wind velocity on the ventilation rate at a constant opening is illustrated in Figure. It was shown that the ventilation rate was less dependent on the wind velocity when the wind velocity was approximately m/s (9 fpm) or less, which indicates that the thermal buoyancy effect is predominant for such a low wind velocity. At a higher wind velocity, the ventilation rate increased almost linearly with an increase in wind velocity, and the differences in ventilation rate due to different levels of net radiation decreased. CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

Temperature difference ( C) Wind velocity: m/s Height of opening:. m Ratio of sensible heat gain to inside net radiation:. Inside net radiation (W/m )..........9 Ventilation rate (m /m /s).... Inside net radiation (W/m )......... Ratio of opening area to floor area Figure. Predicted effects of the opening area and the inside net radiation on the temperature difference and the ventilation rate...9 CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page of 9

Ventilation rate (m /m /s).... Height of opening:. m Ratio of sensible heat gain to inside net radiation:. Ratio of opening area to floor area:. Inside net radiation (W/m ). Wind velocity (m/s) Figure. Predicted effect of the outside wind velocity on the ventilation rate using a constant ratio of opening area to floor area (.). Conclusions A simulation model for open-roof greenhouses was developed to predict the temperature difference between inside and outside and the natural ventilation rate simultaneously. The model parameters were calibrated statistically using the observed conditions of an open-roof greenhouse. The standard errors of the temperature differences for two measurement heights were within.9 C (. F). There was a trend for the predicted temperature difference to be slightly overestimated when the roof segments were more widely opened. In addition, the observed inside temperature occasionally dropped below the outside temperature. The model is not capable of predicting such negative temperature differences. Although further modification is required, the model can provide a useful means to implement new environmental control strategies for open-roof greenhouses. Acknowledgements Partial support for this study was received from the New Jersey Agricultural Experiment Station. NJAES Publication No. P---. References Both, A.J., E. Reiss, D.R. Mears, and W.J. Roberts.. Open-roof greenhouse design with heated ebb and flood floor. ASAE Paper No.. St. Joseph, Mich.: ASAE. NJAES Paper No. P---. pp. Boulard, T., J.F. Meneses, M. Mermier, and G. Papadakis. 99. The mechanisms involved in the natural ventilation of greenhouses. Agric. and For. Meteorol. 9: -. Kittas, C., T. Boulard, and G. Papadakis. 99. Greenhouse ventilation rates through combined roof and side openings: an experimental study. Acta Hortic. : -. Roberts, W.J.. Let the sunshine in. Resource. (): -. NJAES Paper No. E---. CCEA, Center for Controlled Environment Agriculture, Cook College, Rutgers University Page 9 of 9