AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products



Similar documents
Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

TEIP11 I/P signal converter for standard signals. Measurement made easy

The Unique Accelabar Flow Meter

For Multi-Parameter Meters see mvx

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Electronic Flow Switches

Plastic tube flowmeters Series PT/PS

Technical data sheet TDS0070

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Sanitary Type Electronic Flow Switches

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

3DLevelScanner II TECHNICAL DATA SHEET

API Marine. BMS Presentation. Ballast Measurement Systems

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

MTII4200 level Transmitter Installation, Operation & Maintenance Instructions

3500/62 Process Variable Monitor

2.12. page Products for Explosion hazardous Environment

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Thermatel Model TA1 Mass Flow Transmitter

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

COMBIMASS. Technical Data COMBIMASS eco-bio +

USB-500/600 Series Low-Cost Data Loggers and Accessories

EBS852 (Contrac) Power Electronic Unit

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Actuators & Positioners LP - Linear Pneumatic Piston Actuator. Cylinder Actuators. High resolution, sensitivity, and fast response

Turbine Flowmeters for Gas Applications

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

In-Line Electronic Flow Switches

Immersible Thermal Gas Mass Flow Meter FeaTures DescrIpTIon

Model 3051 Pressure Transmitter with HART Protocol

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs. Accuracy +/- 1% of reading plus 0.

Technical Data. Dimensions

Givare NC-SRS 280 och 880

Typical Aluminum GFM Mass Flow Meter

O C M III. Open Channel Flow Monitor

Compact pressure switch Flameproof enclosure Ex d Model PCA

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

Triple Waveband Infra-Red Flame Detection

Micro Motion Model D and DL Coriolis Flow and Density Meters

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Liquid Level Limit Switch liquiphant T FTL 20

Technical Data. Dimensions

Microcor Wireless Transmitter (MWT)

SITRANS F flowmeters SITRANS F M

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Micro Motion 3098 Gas Specific Gravity Meter

Solenoid Valve Island Type 3965

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

S300 Series Dust Monitors

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Rosemount 751 Field Signal Indicator

Rosemount DIN-Style Temperature Sensors and Thermowells (Metric)

Terminal Boxes Series 8146

Thermometer in stainless steel with capillary and switch contacts

Velomitor Piezo-velocity Sensor

Inductive sensor NI10-M18-Y1X-H1141

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Digital inductive conductivity transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

IFC 070 Technical Datasheet

SEISMIC VELOCITY TRANSDUCER T1-40

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Mobrey open channel flow measurement systems

Analog signal converters CC-E I/I Current / current isolators

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Instruction Manual. T3111 T3111L T3111P T3111Ex

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Flow switches Series AD/VH

Terminal Box. Specifications TNCN

How To Use A Flowmeter

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

D. PARAMETER SPECIFICATION Measured Variable: Displacement

General Purpose ph/orp Sensors

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

Turbine Flow Sensor Series VTR

Transcription:

Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution 4-20 ma Output Simple Mounting and installation Very Compact Design Calibrates Without Opening Enclosure Stainless Steel Enclosure Custom Floats Available Measurement of Total or Interface Level

SPECIFICATIONS Electronic Transmitter Repeatability Non-linearity Accuracy Loop Supply Voltage Housing Type Polarity Protection Output Failsafe Operating Temperature Humidity Electrical Connection Enclosure Rating.01% of full scale or 0.030, whichever is greater.02% of full scale or.07, whichever is greater.02% of full scale or.10, whichever is greater 13.5 to 36 VDC Explosion proof 316L SS with 1/2 FNPT Electrical Connection Diode in series with loop Standard 4-20 ma Calibration via magnets Field Selectable: Upscale or Downscale Electronics 40 to 170ºF (-40 to 77ºC) Ambient 0-100% R.H. non-condensing 1/2 FNPT Standard; M20 Optional IP67 Sensor Tube Material Operating Temperature Max Pressure Measuring Range Mounting 316/316L Stainless Steel, 5/8 OD -40 to 170ºF / -40 to 77ºC Standard Up to 250ºF / 121ºC with 10 extension (H1) 1800 psig @ 250ºF Standard 124.1 bar @ 121ºC Standard 1 to 16 ft. / 0.3 to 4.8 m Standard 3/4 MNPT compression fitting (refer to ordering information for options) Total Interface AT500 Sample Applications Total and Interface Measurement 2 AT100 Magnetostrictive Level Transmitter Data sheet

Approvals Factory Mutual Research Corporation: XP/I/1/ABCD/T6 Ta=77 C; I/1/AEx d IIC/T6 Ta=77 C; DIP / II,III / 1 / EFG / T6 Ta=77 C IS/I/1/ABCD/T4 Ta=77 C; I/0/AEx ia IIC/T4 Ta=77 C-ELE 0035/NC; Entity; NI/I/2/ABCD/T4 Ta=77 C; S/II,III/2/FG/T5 Ta=77 C; NEMA 4X CSA International: Hazardous Locations Class I, Div. 1, Grps A,B,C,D; Class II, Div. 1, Grps E,F,G; Class III; Class I, Zone 1, Ex d, IIC T6: Intrinsically Safe Entity - For Hazardous Locations: Class I, Div. 1, Grps A,B,C,D, Temp. Code T4; Class I, Zone 0, Ex ia IIC T4 when installed per drawing ELE0035, Max. operating temp. 77 C, Encl. Type 4X. ATEX: Flameproof: EX II 1/2 GD T85C EEx d IIC T6 Intrinsically Safe: EX II 1 GD T85C EEX ia IIC T6 GOST Russia, GOST Kazakhstan: 1ExdIICT6, 0ExiaIICT6, IP67 Safety AAR Association of American Railroad Certification with FM Approval: E069022 Third Party Safety Integrity Level (SIL) data (FMEDA analysis) for Safety Instrument Systems engineering is available. PRINCIPLE OF OPERATION The AT500 is based upon the magnetostrictive principle. The sensing tube contains a wire which is pulsed at fixed time intervals. The interaction of the current pulse with the magnetic field created by the magnetic float causes a torsional stress wave to be induced in the wire. This torsion propagates along the wire at a known velocity, from the position of the magnetic float and toward both ends of the wire. A patented piezo-magnetic sensing element placed in the transmitter assembly converts the received mechanical torsion into an electrical return pulse. The microprocessor-based electronics measures the elapsed time between the start and return pulses and converts it into a 4-20 ma output which is proportional to the level being measured. AT500 Components Principle of Operation Dimensions SENSOR WIRE PIEZO-MAGNETIC SENSOR* 10 typ. CURRENT PULSE START PULSE L1 MAGNETIC FLOAT AS- SEMBLY TORSIONAL WAVE RETURN PULSE L ML *Patented L2 = 3.5 Data sheet AT100 Magnetostrictive Level Transmitter 3

ORDERING INFORMATION AT500/a/b/c/d/e/f/g/h/i/j: /a Probe Material S6 316L Stainless Steel Standard /b Transmitter configuration L Local Transmitter Standard /c Transmitter Housing S 316L Stainless Steel Housing Standard /d Probe Type R1 Rigid Probe 5/8 in. O.D. (16 ft./ 4.87m maximum probe length) Standard SW1 1/2 OD Probe for Insertion into 5/8 OD x 0.049 Wall Sensor Well Note: Specify and order sensor well separately. SW2 5/8 OD Probe for Insertion into 3/4 Sch. 40 or Sch. 80 Sensor Well Note: Specify and order sensor well separately. /e Process Temperature Options H0 170ºF / 77ºC Maximum Standard H1 /f Electrical Connection F5 1/2 in. FNPT Standard 250ºF / 121ºC. Maximum (Top of transmitter is 17 in. / 43 cm above tank nozzle) /g Approvals FM CEI CEX GR AAR M2 RF Factory Mutual and CSA Canadian Standard Association ATEX Intrinsically Safe ATEX Flameproof GOST Russia AAR Association of American Railroad Certification with FM Approval M20 Connection RFI Filter with 1/2 in. MNPT connection and flying leads 4 AT100 Magnetostrictive Level Transmitter Data sheet

/h Process Connection CF 3/4 in. MNPT x adjustable compression fitting Standard FL Flange with 3/4 in. NPT tap shipped loose; Specify from Flange Selection chart (SLG-0001-1). /i Float Type Fnn Selection from Standard Float Chart (SLG-0003-1) F1B, F2B, F17B, F15B Standard or specify /FXX for custom float /j Length L Available Accessories CD M20 ISO FITTING CONHEA4F CONHEA4M Standard lengths: 15.5 in. / 394 mm 27.5 in. / 698 mm 39.5 in. / 1003 mm 51.5 in. / 1308 mm 63.5 in. / 1613 mm 75.5 in. / 1918 mm 87.5 in. / 2222 mm 99.5 in. / 2527 mm 111.5 in. / 2832 mm 123.5 in. / 3137 mm 135.5 in / 3442 mm 147.5 in. / 3746 mm Custom Lengths to 16 ft. / 4876 mm specified in inches or millimeters Centering Disk: specify stilling well inside diameter M20 Connection 3 pin female cable connector with weatherproof cap rated for general purpose & intrinsically applications only. 3 pin male cable connector with weatherproof cap rated for customers cable at loading station. General purpose & intrinsically safe applications only. Data sheet AT100 Magnetostrictive Level Transmitter 5

Contact us ABB Inc. 18321 Swamp Road Prairieville, LA 70769 USA Phone: +1 225 673 6100 Service: +1 225 677 5836 Fax: +1 225 673 2525 Service e-mail: service@us.abb.com www.abb.com/level Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts is forbidden without prior written consent of ABB. DS/AT100-EN Rev. A 06.2012 Copyright 2012 ABB All rights reserved