KFC VERTICAL TYPE AIR HANDLING UNIT.

Similar documents
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Element D Services Heating, Ventilating, and Air Conditioning

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

KONRAD. Hybrid Fancoil Series

ECOCIAT. Domestic hot water heat recovery unit

Bring the fresh in. Dedicated Outside Air Systems

Under sill units. Type FSL-B-ZAS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

PLUG and PLAY VRV Connection

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

RPV - RP - RA air handling units

CRAC Precision climate control units for data centres

Innovent LASER Packaged Fresh Air Conditioning Units

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Chilled Water Precision Air Conditioner For Critical Application

Installation Manual CLIFC Fan & Coil Variable Speed

CE6500 Energy Recovery Ventilator

Solar Hot Water Heaters


SECTION HEAT PUMPS

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

HEAVY DUTY STORAGE GAS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

FLASH TANK ECONOMIZER PRODUCT GUIDE

Cooking at the Speed of light!

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

squrboxbox heat recovery squrboxbox I technical information

- White Paper - Data Centre Cooling. Best Practice

HVAC Systems: Overview

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Chilled Water HVAC Systems

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

We have been working in an ideal climate for thirty years.

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Chilled Water Fan Coil Unit

Commercial Gas Furnace Upflow

Cool Design for Homes and Offices

COMMISSIONING OF HVAC SYSTEMS

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

york air-conditioning products Residential & VRF News 2015

Mechanical Rooftop Custom Capabilities

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Transformer oil cooler ALFA A02

Closed Circuit Cooling Towers

TWE+TTA TWE+TWA T.R.

CADB and CADT-D / DI / DC Series

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

Defining Quality. Building Comfort. Heating and Cooling Coils

UDSA - UDSBD unit heater

CoolTeg Plus Chilled Water (CW) version: AC-TCW

lindab we simplify construction Air Handling Units Product Overview

Johnson Air-Rotation Systems

Surface Technology. Centrifugal Fan GMD

1.2 Refrigerant Equipment. General

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Nominal Life Expectancy for Building Components

Lesson 36 Selection Of Air Conditioning Systems

Glossary of Heating, Ventilation and Air Conditioning Terms

SECTION MORTUARY REFRIGERATORS

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Operators manual Basic water heater

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

GREE, MAKING BETTER AIR CONDITIONERS

HVAC Processes. Lecture 7

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Appendix - Controllers 179

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Commercial Semi-Instantaneous Water Heaters

Product Data Bulletin

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

TOP 10 NOISE CONTROL TECHNIQUES

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Cooling kw Heating kw

Product Overview Benefits

Basics of HVAC Cleaning

Supply air diffuser ROKA/RPKA

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Local Dealer:

Transcription:

KFC VERTICAL TYPE AIR HANDLING UNIT CONSTRUCTION AND BUILDING TRADE, SHOPPING CENTERS, TOURISM SECTOR, EDUCATIONAL FACILITIES, SPECIFIC PROCESS SYSTEMS, INDUSTRIAL PLANTS

KFC KFC 3 H:1.80 m ALDAG keeps the right to change the technical specifications and the views of the equipment without prior notice.

VERTICAL TYPE AIR HANDLING UNIT VERTICAL TYPE AIR HANDLING UNIT KFC units are used for heating and cooling individual locations. In winter season, boiler provides a supply of hot water for the KFC unit and in suer season, chiller group provides a supply of cold water for the KFC unit. KFC can be connected to a separate ductwork or plenum cell system. They can be installed separately on each floor in multi-storey buildings and can be operated individually. The operating period of KFC fully depends on flat owner's demand which provides considerable savings in energy consumption. KFC is an optimum air-conditioning unit for individual locations thanks to its ease of maintenance and small size which make it well suited for confined spaces. VERTICAL TYPE AIR HANDLING UNIT TECHNICAL SPECIFICATIONS 1 - CASING The casing is made of steel or aluminium profiles. The double-layered insulated panels provide a decorative appearance on the casing. The galvanized sheet panels are electrostatic powder coated. The models from KFC - 3 to KFC - 15 are made of one single unit, while the models from KFC 20 to KFC - 30 are made of two units. The thickness of the panels is 50 and the panels are insulated with rock wool. 01

2 - FAN and MOTOR GROUP KFC units are equipped with double inlet forward curved centrifugal fans as a standard feature. These fans are belt - pulley driven. Optionally, double inlet backward curved centrifugal fans and EC plug fans can be used on request. EC plug fans provide significant savings in energy consumption and the fan speed can be arranged automatically according to the pressure. 02 3 - COOLING & HEATING COIL The desired room temperature can be obtained by thermally efficient copper tube aluminium finned coils. The coils are designed to be compatible with 2 piped systems or 4 - piped systems. 03 05 4 - FILTERS The filter is from G2-G4 filtration class which is easy to remove and clean. 5 - DRAIN PAN The KFC units which are used for cooling purpose are equipped with drain pan. It is made of insulated 304 quality stainless sheet. OPTIONAL ACCESSORIES 1 3 way valve and actuator 2 - Zone circulation pump 3 - Automatic control 4 - Electric heater 5 - Fresh air damper 6 - Heat recovery recuperator 7 G4 F9 air filters for clean rooms 8 - Sound Attenuator Cell 9 - Bottom blowing cell for raised floors Control Panel Fresh Air

VERTICAL TYPE AIR HANDLING UNIT TECHNICAL SPECIFICATIONS TYPE KFC 3 KFC 4 KFC 5 KFC 7.5 KFC 10 Air Flow Total Pressure External Static Pressure Fan Type m 3 /h Pa Pa 2500 1200 900 1200 1300 1050 950 1200 950 1150 1200 830 1100 1200 900 900 790 4000 5000 7500 10000 430 800 700 430 400 760 500 700 800 400 725 720 430 550 Fan Speed Nd/min 4280 2370 3150 3730 1875 3550 2270 1810 3000 1865 1480 2900 2805 1124 1920 Motor Power 1.5 1.5 1.5 2.2 2.2 2.2 4.0 3.0 2.5 5.5 4.0 4.1 5.5 4.0 3.8 Current (380V - 50 Hz) Amper 3,6 3,6 3,2 5,5 5,5 3,6 4,0 3,0 2,5 11,6 8,5 6,5 11,6 8,5 6,1 Cooling Capacity 13.4 21.6 29.4 45.4 59.5 Sensible Cooling Capacity 9.5 15.5 20.5 31.5 41.3 2.26 3.6 5.07 7.77 10.2 34.8 25.5 36.5 27 32.9 Heating Capacity (A) 19.5 31.5 42.2 68.5 86.8 0.9 1.4 1.91 2.91 3.81 20.3 10.2 16.2 33.1 25.1 Heating Capacity (B) 15.9 25.7 34.7 54.6 71.4 0.68 1.08 1.47 2.37 3.1 14.5 11.4 14.7 24.05 18.3 Heating Capacity (C) 11.3 18.3 24.6 38.5 50.5 m 3 /h 1 1.58 2.2 3.42 4.4 24.2 14.1 22.7 41.8 35.3 Electrical Heating Capacity 10.0/1 15.0/1 20.0/2 27.0/3 30.0/3 Sound Level db(a) 61 61 62 65 65 Dimensions Width Height Length 715 1600 715 1600 715 1600 1325 2200 1325 2200 1630 Discharge Duct Dimensions 300X300 325x325 350x350 400x400 475x475 Exhaust Duct Dimensions Exhaust Damper Fresh Air Damper Cooling Circuit Connection Diameter Heating Circuit Connection Diameter Weight inç inç Kg 310x920 310x920 200x200 1-1 250 310x920 310x920 200x200 1-1 285 310x1225 310x1225 300x300 1-1 325 615x1225 615x1225 300x300 1-1 440 615x1225 615x1225 300x300 1 1/2-1 1/2 550 Cooling Capacity; Water Inlet / Water Outlet Temperature: 7/12 C, Inlet Air Temperature / Rh 27 C / %50 Heating Capacity; Inlet Air Temperature: 20 C Water Inlet / Outlet Temperature A: 90 / 70 C B: 80 / 60 C C: 60 / 50 C

TECHNICAL SPECIFICATIONS TYPE KFC 12 KFC 15 KFC 20 KFC 25 KFC 30 Air Flow m 3 /h 12500 15000 20000 25000 30000 Total Pressure External Static Pressure Pa Pa 1150 900 1200 1400 1030 1100 1400 915 900 1275 1010 1000 1275 1010 900 750 460 800 880 500 725 910 510 550 825 560 600 825 560 550 Fan Type Fan Speed Nd/min 2490 1010 2900 2111 980 2900 2537 1059 1920 1835 835 1920 1531 780 1920 Motor Power 7.5 5.5 7.5 7.5 7.5 8.0 15.0 11.0 8.0 15.0 11.0 11.0 15.0 15.0 11.3 Current (380V - 50 Hz) Amper 15,5 11,6 1,2 15,5 15,5 13,2 28 22 12 28 22 17,8 28 28 18 Cooling Capacity 63,3 86.5 106.9 133.8 165 Sensible Cooling Capacity 45,4 60.3 75.8 94.7 117 10,9 14.9 18.4 23 28.3 16,8 33.9 20.3 36.1 48.2 Heating Capacity (A) 97,9 126.6 161.8 209.6 233.1 4,32 5.58 7.23 9.36 10.4 18 32.4 25.2 21.6 22.9 Heating Capacity (B) 80,3 104.3 133.1 172.3 191.5 3,52 4.6 5.86 7.56 8.4 12,9 27.2 21.2 15.7 16.5 Heating Capacity (C) 57,1 73.7 94.2 122.1 135.8 4,96 6.50 8.20 10.7 11.9 21,3 45.5 35.5 30.4 29.3 Electrical Heating Capacity 36.0/3 42.0/3 51.0/3 54.0/3 60.0/3 Sound Level db(a) 66 66 68 68 69 Width 1325 1325 Dimensions Height Length 2200 1630 2500 1630 2500 1935 2800 2545 2800 2545 Discharge Duct Dimensions 575x575 575x575 575x575 725x725 825x825 Exhaust Duct Dimensions 615x1530 615x1530 615x1835 1225x1835 1225x1835 Exhaust Damper 615x1530 615x1530 615x1835 1225x1835 1225x1835 Fresh Air Damper Cooling Circuit Connection Diameter Heating Circuit Connection Diameter Weight inç inç Kg 400x300 1 1/2-1 1/2 575 400x300 2-2 650 400x300x2 2-2 900 400x400x2 2 1/2-2 1/2 1 1/2-1 1/2 1250 400x400x2 3-3 2-2 1300 Cooling Capacity; Water Inlet / Water Outlet Temperature: 7/12 C, Inlet Air Temperature / Rh 27 C / %50 Heating Capacity; Inlet Air Temperature: 20 C Water Inlet / Outlet Temperature A: 90 / 70 C B: 80 / 60 C C: 60 / 50 C

Heating Cooling Air Conditioning Ind.&Trd.Inc. Istanbul Central Office / Factory 1: Cumhuriyet Mah. Abdi İpekçi Cad. No:1 (34876) Kartal - İstanbul - TURKEY T: +90 (216) 451 62 04 Pbx F: +90 (216) 451 62 05 Istanbul Regional Office / Factory 2: Ramazanoğlu Mah. Sanayi Cad. No:11 (34906) Pendik - İstanbul - TURKEY T: +90 (216) 595 10 60 Pbx F: +90 (216) 595 10 68