Woodstove And Freestanding Fireplace Installation Guide

Similar documents
CHIMNEYS AND FIREPLACES

780 CMR CHIMNEYS, FIREPLACES AND SOLID FUEL-BURNING APPLIANCES

Wood Heat The Safe Way

Installation Instructions

from Farm Bureau Insurance

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Wood Burning Safety Guide

woodburning stoves installation and procedures

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Table of Contents Interior Exterior

FREESTANDING CLEAN AIR WOODBURNER

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

Repair of Earthquake-Damaged Masonry Fireplace Chimneys SOUTH NAPA EARTHQUAKE RECOVERY ADVISORY

Across America. Wood & Coal Brochure

Certification: Building Plans Examiner. Exam ID: B3

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Guidelines for Earthquake Bracing Residential Water Heaters

Mark Cramer Inspection Services, Inc.

WOOD HEAT TECHNIQUES TACTICS & TIPS

Residential Deck Safety, Construction, and Repair

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Troubleshooting Draft Problems in Chimneys

How to build a Pizza Oven in 4 days

Fire Damage. To Help Prevent. a Guide

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

LAYING BLOCK AND BRICK

Building Code Clarifications - 7. Fire Resistance

ASX7-4-IOM-7 J

COMMONLY USED RESIDENTIAL BUILDING CODES

1 DESCRIPTION OF THE APPLIANCE

CHAPTER 14 BUILDING CODE

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

THIS BOOK CONTAINS IMPORTANT INFORMATION. PLEASE KEEP IT IN A SAFE PLACE FOR FUTURE REFERENCE.

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

The Savannah Steel Series Wood Burning Stoves and Inserts

Boiler Plan II Table of Contents

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Chapter 3 Pre-Installation, Foundations and Piers

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

CHAPTER 6 CONSTRUCTION TYPES

Excerpts from the Canadian National Building Code (NBC)

Chimneys in Thatched Properties

Installation Instructions

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Pre-Drywall Inspection Report

Crawford Inspection Services C.C.B. #

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Ravelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the

The Homeowner s Guide To CHIMNEYS, FIREPLACES AND WOODSTOVES

CHIMNEYS AND FIREPLACES

Guidelines for Earthquake Bracing of Residential Water Heaters

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

Gas-Fired, Residential Storage Type Water Heaters

ISO Types 1-6: Construction Code Descriptions

Superform Products Ltd.

Installation Instructions

Building Condition Assessment Report

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.

3 Masonry and Manufactured Stone (Interior and Exterior)

CHAPTER 5 WATER HEATERS

H-Stud Area Separation Wall System

How To Make A House Safe

Model (E.P.A. Phase II Approved)

Wisconsin Building Products Evaluation

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

GAS STOVES woo GAS STOVES

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

HAZARDS AND THREATS WILDFIRES HOMEOWNERS CHECKLIST INSIDE THE HOME

Homeowner s Handbook

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Elevating Your House. Introduction CHAPTER 5

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

Technical Notes 3B - Brick Masonry Section Properties May 1993

MANUFACTURED HOUSING USED AS DWELLINGS

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

POST AND FRAME STRUCTURES (Pole Barns)

Commissioning of Heat Producing Appliances Burning Solid Fuel

SRP Pricelist 2015 Including VAT. Stoves for every home

B. DEFINITIONS LINING OLD CHIMNEYS A. INTRODUCTION C. REASONS FOR LINING

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Single Family Residential Basement Finish

Arapahoe County Residential Water Heater Installation and Inspection Guide

Patio Covers / Carports

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Transcription:

We hope you will follow the rules in this pamphlet. If you have questions, please call the Building Department at 208-756-6913, ext. 263, ext. 264, or ext. 270. Woodstove And Freestanding Fireplace Installation Guide * * * * * * * * * * * * Happy Heating * * * * * * * * * * * * * * * * * Please remember to call for all inspections * * * * * Presented in the interest of public safety by the City and County Building Department Prepared by the Building Official, Gary Goodman 18

Preface Each year, improperly installed and/or maintained woodstoves and fireplaces are responsible for a large number of fires and fire-related damage. These problems can be overcome if basic safety measures are observed. The purpose of this pamphlet is to outline the requirements of the City of Salmon and County of Lemhi building departments, and to give the installer and user of wood burning fireplaces and stoves a guide to assist them in obtaining a safe and efficient installation. Of course, once the unit is installed, proper maintenance and common sense are needed to keep it from becoming a fire hazard. We hope this pamphlet will help you to obtain the maximum enjoyment, and at the same time, peace of mind from your fireplace or woodstove. IRC TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS ITEM LETTER a REQUIREMENTS Hearth slab thickness A 4 Hearth extension (each side of opening) Hearth extension (front of opening) Hearth slab reinforcing Thickness of wall of firebox Distance from top of opening to throat F 8 Smoke chamber wall thickness Unlined walls Chimney Vertical reinforcing b Horizontal reinforcing B C D E G H J 8 fireplace opening < 6 square foot. 12 fireplace opening 6 square foot. 16 fireplace opening < 6 square foot. 20 fireplace opening 6 square foot. Reinforced to carry its own weight and all imposed loads. 10 solid brick or 8 where a firebrick lining is used. Joints in firebrick 1/4 maximum. 6 8 Four No. 4 full-length bars for chimney up to 40 wide. Add two No. 4 bars for each additional 40 or fraction of width or each additional flue. /4 ties at 18 and two ties at each bend in vertical steel. Bond beams K No specified requirements. Fireplace lintel L Noncombustible material. Chimney walls with flue lining M Solid masonry units or hollow masonry units grouted solid with at least 4 inch nominal thickness. Distances between adjacent flues - See Section R1003.13. Effective flue area (based on area of fireplace opening) P See Section R1003.15. Clearances: Combustible material Mantel and trim Above roof R See Sections R1001.11 and R1003.18. See Section R1001.11, Exception 4. 3 at roofline and 2 at 10. Anchorage b Strap Number Embedment into chimney Fasten to Bolts Footing Thickness Width S T 3/16 1 Two 12 hooked around outer bar with 6 extension. 4 joists Two 1/2 diameter. 12 min. 6 each side of fireplace wall. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 square foot = 0.0929m2. Note: This table provides a summary of major requirements for the construction of masonry chimneys and fireplaces. Letter references are to Figure R1001.1, which shows examples of typical construction. This table does not cover all requirements, nor does it cover all aspects of the indicated requirements. For the actual mandatory requirements of the code, see the indicated section of text. a. The letters refer to Figure R1001.1. b. Not required in Seismic Design Category A, B or C 2 17

The homeowner may do his own work, provided they follow the provisions of the code. The homeowner is responsible for the permit, but the person actually doing the work is responsible for making sure the permit was issued and calling for all required inspections. The person actually doing the work is the one that will be held responsible for the installation, and making sure that it complies with code. Installing a fireplace, or woodstove, or makes changes to the same without a permit is a violation of the law, in addition to the fact that it could be dangerous. Please check with our department before any work is commenced and please call for all inspections, as we will not make automatic inspections, even though a permit is issued. The inspection must be called for and scheduled with us before using. Many insurance companies are now requiring Certificates of Compliance before they will renew or issue fire insurance to the home where a particular woodstove or fireplace is installed. Listed and Unlisted Units. The requirement contained in this pamphlet concerning clearances from unprotected and protected combustibles apply to units that have not been tested and listed by an approved testing agency such as U.L., F.M., I.C.C., E.S., etc. Those units that are listed by such agencies must be installed according to the requirements set forth by the manufactured and the listing agency. The Building Official/Inspector having jurisdiction must approve the installation of all listed and unlisted units in accordance with the codes. Manufactured Home Installations. Due to the generally tighter and less fire resistive construction of manufactured homes, special precautions must be taken when installing woodstoves or fireplaces in them. The state of Idaho and 16 3

this agency requires that woodstoves or fireplaces being installed in manufactured homes meet the federal standards for manufactured home installation. Units that meet these standards will have a plate or metal tag attached to the unit so indicating. A permit for a manufactured home installation will not be issued without evidence of compliance with the above, so before you purchase a stove or fireplace for a manufactured home, make sure it qualifies as Manufactured Home Approved. In addition, it should be stressed that any cutting of the structural members of the manufactured home may invalidate the certification of compliance with Idaho Manufactured Home Regulations. Smoke Detectors. If you do not already have smoke detectors in compliance with current code, then you are required to buy, properly install, and maintain smoke detectors in conjunction with the installation of wood burning stoves or fireplaces. Contact your Building Official if you have specific questions regarding this issue. Clearances from Combustible Materials. As noted previously, the following figures apply only to those stoves or fireplaces that are unlisted or untested by an approved testing agency. Listed units should be installed according to the manufacturer s instructions. Any deviations must meet the approval of the agency having jurisdiction. The national fire protection association as well as the IMC (International Mechanical Code) and other nationally recognized agencies all require a Minimum of 3-feet from unprotected combustible material of any type, whether it be a wall, furniture, curtains, or any other type of material that might ignite. In some cases there may be a problem finding the room to allow this much space between the stove and the adjacent wall. In these cases, shielding may be pro- 4 15

vided for either the wall or the stove or fireplace in question and spacing may be reduced to 12-inches and 18-inches respectively, as shown in illustrations 1, 3, and 4. A wall shield may consist of any of the following: Brick, Stone, Lava Rock, Brick, 24-gauge (or thicker) sheet metal, 5/8- inch type X fire rated gypsum board or cement board covered with an approved non-combustible material, such as ceramic tile, Z Brick, or stucco. The authority having jurisdiction must approve other heat shield materials. Shielding applied to a stove must be metal, (not aluminum) at least 24-gauge. As shown in illustrations 1, 3, and 4, the wall shield and stove shield must be at least one-inch (1 ) from the wall or stove to which they are applied. Noncombustible spacers, such as section of metal pipe, ceramic or a double thickness of ½-inch gypsum board must be used for the wall shield spacers. Only metal spacers may be used on the stove shield. Both the stove and wall shields should be open at the top and bottom to allow air to flow behind them to facilitate cooling. Louvers or vents on a wall shield large enough to permit the free flow of air would be acceptable on a wall shield. A wall shield must extend beyond the sides and above the stove as shown in the illustrations. The stove shield must be at least as large as the side or rear of the stove that it protects. It should be stressed that the clearances mentioned are the minimum that could be considered as adequate if the unit is not over-fired. This jurisdiction does not assume any responsibility or liability, either expressed or implied, for any damages resulting from the use of the standards outlined in this pamphlet. Chimney Connectors. The pipe that goes from the stove to the chimney is called the chimney connector. It may be a single wall pipe, but must be approved for use with solid fuels. Aluminum gas vent pipe definitely may not be used. 14 5

The chimney connector must be at least 18-inches from any unprotected combustible surface. With a heat shield, installed as shown in illustrations 1 and 5, the chimney connector may be as close as 9 inches from any combustible surface such as, a wall, ceiling, or other similar surface. To obtain closer spacing s a class A listed triple wall or double wall-insulated chimney must be used. All chimney connectors must have a slope of at least ¼-inch per foot toward the stove in order to allow liquid condensate to run back into the stove rather than pooling in the pipe. Chimney Requirements. You may use either a masonry (brick or block) chimney with an approved liner (red fireclay, stainless steel or other listed lining system). Unlined chimneys or unapproved liners such as black or blue single wall pipe may not be used. Instructions pertaining to the building of a masonry chimney are beyond the scope of this pamphlet. For further information on the building of a masonry chimney, please consult your local building department. Metal chimneys must be installed exactly according to the manufacturer s listed instructions. Usually a 2-inch minimum clearance from combustibles is required from approved triple wall or double wall-insulated pipe. Any chimney flue must have a cross sectional area at least as large as the chimney connector and the chimney connector must be at least as large as the flue outlet of the stove. All chimneys must extend at least 2-feet above the peak. The chimney must also extend at least 3-feet beyond the hole in the roof through which it protrudes, as shown in illustration 6. Above heights, do not include the chimney cap/spark arrestor. Spark arrestors are required on any chimney near a wooded, grassy or brush covered area, and are recommended for all chimneys. Spark arrestors should have an area of at least 4-times the area of the flue they serve. They may be made of screen or expanded metal with holes no 6 13

smaller than 3/8-inch in one dimension and no larger than ½-inch in any one dimension. Multiple appliances on a single flue are prohibited. For safety reasons, each solid-fuel burning appliance must have its own flue. A metal chimney extending more than 4-feet beyond the roof should be well supported with guy-wires to keep it from being blown down by the wind. Protection of Combustible Floors. Combustible floor protection for listed units shall be provided as per manufacturer s instructions. Combustible floor protection for unlisted units shall be provided as follows: where the stove has legs that provide at least 18-inches of open space between the bottom of the firebox and the floor. A minimum of 24-gauge sheet metal is required. Where the stove has legs that provide between 6-inches and 17-inches of open space between the bottom of the firebox and the floor, the minimum protection needed is 3/8 inch non-combustible material (such as ceramic tile, brick, concrete, etc.) Where the stove has legs that provide less than 6 inches of space between the underside of the firebox and the floor, the minimum protection is 4-inches of hollow masonry, laid to provide horizontal air circulation through the masonry layer. In all the above cases, the required protection must extend at least 12-inches beyond the sides and rear of the stove, and 18-inches beyond the front or loading side, as shown in illustration 2. Fireplace Inserts. Inserts for fireplaces may be thought of as just woodstoves without legs that are designed to sit at least partially in the mouth of an existing masonry fireplace. Inserts are not allowed in metal Zero Clearance fireplaces. Inserts generally follow the same rules as woodstoves regarding clearances, etc. Provisions must be made 12 7

for the cleaning of the area in the fireplace behind the insert periodically. A direct connection from the insert to the chimney flue is recommended whenever possible in order to facilitate cleaning and minimize creosote build-up. A clean-out door in a chimney on an accessible exterior wall is another way to get at the interior of a fireplace with an insert. See illustration 7. Proper Cleaning, Fire and Maintenance. Once you have gone to the trouble of getting a safe installation, you can keep it safe by observing the following safety precautions: 1. Do not over-fire your stove! Over-firing can cause warpage of a metal stove and chimney parts, or cracking in the case of cast-iron units. It can also cause wood to decompose to pyrophoric carbon if the wood is subject to high heat over a long period of time. 2. Watch for and immediately repair any deterioration in the chimney or connectors such as loose mortar, cracks in metal stoves, loose pipe connections, etc. 3. Keep your chimney, stove, and chimney connector clean and free of soot and creosote. Creosote and soot are the byproducts of the combustion of wood. They are basically unburned hydrocarbons that are carried up in the smoke and are deposited on the interior of the chimney and the chimney connector. When the fire does not have enough air and is burning at a relatively low temperature is when creosote builds up the fastest. A cool flue also causes the creosote to condense more rapidly than normal. We recommend that each time you light the stove or at least once a day you allow it to burn with the maximum amount of air for at least 8 11

30-minutes to adequately warm up the flue, and then allow enough air to maintain a chimney connector temperature of between 250-300 degrees Fahrenheit, measured by a chimney connector thermometer. Thermometers may be purchased at your local hardware store or at a wood-heating specialty shop. A typical scenario in which creosote buildup is rapid is when the homeowner fills the stove completely full of wood and cuts the air to a bare minimum before retiring for the night, in order to get an all-night burn. This practice is therefore discouraged. An innovation on the market, which has shown some promise, is the catalytic combustor. This unit lowers the temperature at which the creosote will ignite, thus providing more heat and less creosote build-up. For more information on these devices, see you local hardware or wood stove dealer/distributor. 4. Ash Disposal. Never, we repeat, never put ashes in a cardboard, wooden, or paper container, even though you think they are completely cold. Ashes insulate hot coals and keep them hot for long periods of time. Ashes should be put directly into a metal container and taken directly outside, away from buildings or combustibles of any kind. 10 9