HOME VENTILATION WITH HEAT RECOVERY. Improve your indoor climate and save energy

Similar documents
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

How To Make Your House Breathe

Combi Unit Genius. The energy efficient Building Service Centre

How To Get A Passive House

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

HVAC Processes. Lecture 7

Comfosystems Systems with heat recovery for a comfortable indoor climate

Flexit air handling unit K2 R

Unico Inverter. Unique and efficient.

air conditioners how to choose a cooling system

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Horizontal ventilation units

Dehumidifier D 850E. - Instruction manual version 02

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Lesson 36 Selection Of Air Conditioning Systems

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

Bring the fresh in. Dedicated Outside Air Systems

Energy Efficiency HOSPITALITY.

RRV934. Multi-controller. Synco living

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

How to choose a heat pump and use it wisely

Portable Air Conditioner

USER S INFORMATION MANUAL

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Energy savings in the residential area are essential in

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood

All the best brands all under one roof

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

ENHANCED LABORATORY HVAC SYSTEM

FULL DC INVERTER SYSTEMS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Innovent LASER Packaged Fresh Air Conditioning Units

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

lindab we simplify construction Air Handling Units Product Overview

RPV - RP - RA air handling units

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

KNX for building and room automation simple and efficient

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

More efficiency in office buildings with HVAC, lighting and security

Meaco 30L and Meaco 40L dehumidifier instruction manual

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

Operation and Installation Manual. Max Series

saving energy in comfort Factsheet Recair Enthalpy

Installation and maintenance instructions. Danfoss Vent

We have been working in an ideal climate for thirty years.

Housing Fact Sheets. Moisture Condensation at the Windows

Energy Saving Fact Sheet Air Conditioning

You make dreams a reality. We provide the efficient Air-Conditioning.

Handbook for Basement

CE6500 Energy Recovery Ventilator

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Operating instructions

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

Molds and mildew are fungi that grow

Delivering exceptional performance and Ecovalue. Ecocent

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

FLEXIT S4 R S6 R S7 R

Zehnder Focus 200. Ventilation device

PORTABLE AIR CONDITIONER

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

WHOLE-HOUSE VENTILATION SYSTEMS

ASTACEA4 Inspect complex/central air conditioning systems

More efficiency in hotels with HVAC, lighting and security

ECOCIAT. Domestic hot water heat recovery unit

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Integrated Solar Radiant Systems

Gas Condensing Boilers

USER S MANUAL HSC-24A

101 Low-Cost /No-Cost. Home Energy-Saving Measures

york air-conditioning products Residential & VRF News 2015

Glossary of HVAC Terms

Norwegian Tax Authority - Oslo Norway

Comfort and superior energy efficiency through intelligent home automation

Direct Fresh Air Free Cooling of Data Centres

Flexit Central Vacuum Cleaner

Energy Efficient Air Distribution Systems

Under sill units. Type FSL-B-ZAS

Active Roofs and Facades in Sustainable Renovation

Flexit Central Vacuum Cleaner

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ComfoAir 350 Luxe User Manual

More efficiency in schools with HVAC, lighting and security

Product overview Air conditioning service units

Transcription:

HOME VENTILATION WITH HEAT RECOVERY Improve your indoor climate and save energy

DANTHERM HOME VENTILATION WITH HEAT RECOVERY For healthy indoor air quality, functionality and energy efficiency The indoor climate is important A good indoor climate is all about health and wellbeing for the whole family. It is also about protecting the home against damage from moisture that can easily occur in highly insulated and airtight buildings. With Dantherm s range of highly efficient and energy-saving mechanical home ventilation solutions with heat recovery, suitable for new-build as well as for renovating, you will get the best possible indoor climate and even reduce your heating bill, as up to 95% of the heat is recovered. Advantages of home ventilation with heat recovery Contributes to the energy efficiency of the home Reduces the risk of asthma and allergy Reduces surface moisture condensation Improves indoor air quality Eliminates mould and mildew Removes bad smell No need to open windows Why choose Dantherm Home Ventilation? 50 years experience in the design and manufacture of ventilation systems Danish design and quality made in Denmark Ventilation experts Cost and energy-efficient solutions Wall, loft or ceiling void models Easy to install and easy to use solutions Various control options, from simple wired control panels to advanced remote control NO MORE WORRYING ABOUT THE INDOOR CLIMATE

GET A HEALTHY INDOOR CLIMATE WITH HOME VENTILATION WITH HEAT RECOVERY Dantherm MVHR systems are energy-efficient and economical How MVHR systems work The ventilation system extracts air from the wet rooms (kitchen, bathrooms, toilets and utility room) on a continual basis. A counterflow heat exchanger with thermal efficiency of up to 95% recovers the heat from the extract air that would otherwise have been lost, and transfers it to the supply air. Fresh, heated supply air then flows into the living rooms. Supply air and extract air are totally separated from each other in order to keep the supply air clean. Energy efficiency class A and A+ HCC 2 is rated as energy efficiency class A. With an optional RH sensor and VOC sensor, the HCC 2 will obtain energy efficiency class A+. HCV/HCH are rated as energy efficiency class A. With an optional CO2 sensor and an HAC 1 accessory control, the HCV/HCH units will obtain energy efficiency class A+. HCC 2 HCV HCH Key Benefits of HCC 2 Energy class A or A+ High heat recovery efficiency up to 95% Low installation headroom (< 30 cm) EC motors with low energy consumption (SFP) PHI approved Automatic bypass cooling Frost protection of heat exchanger Dual-handed unit Can be integrated in BMS and KNX systems Can be connected to fire/smoke alarm system Meets building regulations Easy filter change Key Benefits of HCV/HCH Energy class A or A+ High heat recovery efficiency up to 95% Demand-controlled ventilation with integrated humidity sensor EC motors with low energy consumption (SFP) PHI, DIBt approved. SAP appendix Q listed Frost protection of heat exchanger Can be integrated in BMS systems Can be connected to fire/smoke alarm system Meets building regulations Bypass cooling Installer-friendly adjustment of air volumes on the unit Easy filter change

HEATING AND COOLING IN ONE UNIT With Dantherm home ventilation you will be comfortable all year round Energy-efficient technology All Dantherm Home Ventilation units fulfil the market s high demands for low energy consumption and noise levels. Demand control combined with lownoise EC fan motor technology ensure high energy efficiency and contributes to low SFP (Specific Fan Power) values. Cooling features with home ventilation Dantherm home ventilation units cannot provide active cooling like in an air conditioning unit, where the air change rate is up to 8 times per hour. In a MVHR unit the rate of air change is normally approx. 0.5 times per hour. However, Dantherm home ventilation units can provide a cooling effect in the warm season by means of bypass dampers, bypass shunt or integrated software cooling. The bypass shunt has to be mounted onto the heat exchanger manually. Using the bypass shunt supplies fresh and filtered outdoor air to the house, thus improving the indoor climate. Certificates Dantherm s Home Ventilation units are certified by Passivhaus Institute in Darmstadt and Deutsches Institut für Bautechnik in Berlin. Furthermore, they are SAP Appendix Q listed and certified by BCCA. Bypass cooling In units with a bypass module, cold outdoor air is used to cool the house after a hot summer s day. The bypass damper opens for direct supply of cold outdoor air, which enters the house without passing through the heat exchanger. Bypass cooling is controlled by the indoor and outdoor temperature sensors. Bypass shunt For units without the bypass module (HCV 4), fitting the ventilation unit with a bypass shunt is recommended in order to avoid heat recovery when the indoor temperature rises above an acceptable level and where a lower outdoor temperature can still meet normal comfort demands. HCC2 mounted in ceiling void

MANY OPTIONAL FEATURES A wide range of accessories and easy maintenance give you a perfect ventilation solution Frost protection The intelligent control system of Dantherm MVHR systems units ensures that the heat exchanger does not ice up in winter. However, in areas with outdoor temperatures lower than -6 C, we recommend mounting heating coils to pre-heat the outside air before it enters the heat exchanger. Heating coils Pre and post-heating coils for electricity or water are available as optional extras. Pre-heating coils prevent ice building up in the heat exchanger at low temperatures, especially if the built-in frost protection is not sufficient in regions with cold temperatures. Post-heating coils can be used to increase the supply air temperature. Filters All Dantherm Home Ventilation units are fitted with G4 filters as standard for both supply air and extract air. This filter will meet the majority of air cleaning needs. F7 pollen and dust filters are available as optional accessories. F7 filters will ensure that allergens do not enter the house through the ventilation system. Condensate drain All Dantherm Home Ventilation units come with a drainage feature for condensate water, prepared for connection of a drain hose. Maintenance Dantherm Home Ventilation units are virtually maintenance-free. We recommend filters to be changed twice a year to maintain optimum performance. An alarm will indicate when the filters need to be replaced with new ones. Apart from changing the filters and cleaning the outside of the unit, any other form of service has to be carried out by qualified personnel. Dantherm service partners can offer you an annual service where we will check/change the filters and ensure your system is working efficiently, providing a healthy living environment. A video showing how to change the filters can be found on our website www.dantherm.com or on YouTube. Accessories Inside Outside Electrical pre-heating coil GCT pre-heating/after heating coil Extract air Outdoor air Supply air Water heating coil Electrical after heating coil Exhaust air

ADVANCED DEMAND CONTROL With a simple control panel or an advanced wireless remote control Wired control panel HCP 4 HCV/HCH Home Ventilation units come with a wired control panel with demand-controlled automation and integrated humidity sensor as standard. This automatic demand control is based on average considerations that can ensure a comfortable indoor climate under all conditions. The RH sensor will keep the relative humidity at a comfortable level regardless of the activity in the home. With the control panel, the user can manually control the ventilation speed, activate summer or bypass cooling, check alarms and filter status etc. Wireless remote control HRC A wireless remote control with display is available as an accessory to all Dantherm Home Ventilation units. It has been designed to make controlling the ventilation system simple for both the installer and the end user. With the optional wireless control panel the end-user and the installer have access to various functions such as automatic demand control, manual operation, week program operation, away operation, night operation, fireplace operation, etc. Wired control panel HCP 10 A wired control panel is available as an accessory for the HCC 2 unit. With this control panel the user can control the air change, enable demandcontrolled air change, week programs, fireplace mode, bypass cooling, etc. For further details about the various control options, we refer to the technical booklets. Wired control panel HCP4 (Included in HCV + HCH) Wireless remote control HRC (Optional accessory for all models) Wired control panel HCP10 (Optional accessory for HCC2) Manual control of ventilation speed Automatic control of ventilation speed Manual bypass cooling Automatic demand control Manual operation Week program operation Away operation Night operation Fireplace mode Automatic demand control Manual operation Week program operation Summer cooling Manual bypass cooling Fireplace mode Technical data sheets and brochures can be downloaded from our website For further technical details we refer to our technical booklets

PRODUCT SELECTOR Model HCC 2 PLA HCV 4 HCV 5 HCH 5 HCH 8 Installation Wall/ceiling void Cupboard/wall Wall Loft Loft Energy class A (A+ can be obtained with optional accessory kit) Max air flow (m 3 /h) 260 275 375 375 530 Max. floor area (m 2 ) 110 200 260 280 350 Demand control + WxHxD (mm) 600x279x1122 530x1005x434 590x1055x584 580x600x1180 780x600x1180 Weight (kg) 34 32 45 52 70 Duct connection (mm) ø125 ø125 ø160 ø160 ø250 Heat exchanger Plastic Alu Alu Alu Alu G4 filter F7 pollen filter + + + + + PHI certificate SAP Appendix Q listed Automatic bypass cooling Wireless remote control + + + + + Integrated software cooling Frost protection of heat exchanger Week programs + + + + Night mode + + + + + Holiday mode + + + + + Bypass (manual) Fireplace mode + Filter alarm Connection of fire/ smoke alarm system + + + + Connection to geothermal collector + + + + + BMS connection KNX connection Right/left hand switching Wired control panel + Heating coils + + + + + PC tool + RH sensor + VOC sensor + CO2 sensor + + + + + included + optional not available

dantherm.com ELECTRONICS COOLING DEHUMIDIFICATION VENTILATION MOBILE HEATING AND COOLING Dantherm is a market-leading supplier of energy-efficient climate control solutions for customers across the globe. Our subsidiaries in Norway, Sweden, Germany, and the UK and our representative office in Russia unite approx. 240 employees. We operate in the following four main business areas: Electronics cooling: Climate control for electronics and battery cooling in radio base stations and other Telecom infrastructure. Telecom customers include network suppliers and network operators. Dantherm Air Handling A/S Marienlystvej 65 DK-7800 Skive, Denmark Tel. +45 96 14 37 00 Fax +45 96 14 38 20 info@dantherm.com Dehumidification: Mobile and stationary dehumidifiers for drying buildings and for use in private pools and wellness centres. Ventilation: Large ventilation systems used in swimming pools and buildings such as shopping centres and cinemas requiring frequent air change. The range also includes domestic ventilation products based on high-performance heat exchangers. Mobile heating and cooling: Products for heating or cooling of tents and equipment used by the armed forces and aid organisations. The customers are primarily the armed forces in NATO countries as well as tent and container manufacturers. 05.16 Thorvig Tryk, Skive