Emergency Stop Monitoring Safety Relay

Similar documents
Machine Safety Switch: SI-LM40 Series Limit Switch Style

Machine Safety Switches

INTMOD485-LH Protocol Converter

Safety Manual BT50(T) Safety relay / Expansion relay

Tina 2A/B Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Application Technique. Safety Function: Magnetic Door Switch Monitoring

MULTI-BEAM LS10 Light Screen System

Safety Relays ESM/ESM-F

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Advantium 2 Plus Alarm

Modular I/O System Analog and Digital Interface Modules

SECTION LOW VOLTAGE LIGHTING CONTROLS

Single Phase Soft Starter

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Smile 11 AS-i Emergency stop with safe AS-i input node

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Safety technique. Emergency stop module BO 5988 safemaster

CQM1-SF200/CS1W-SF200

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

, User s Manual

SECTION VARIABLE FREQUENCY DRIVES

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

i410/i1010 AC/DC Current Clamp

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

Emergency Stop Push Buttons

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

LCD5500Z / PKP-LCD v3.x Installation Instructions

GTEC transfer switch open transition

BACnet Automation Interface Module (Network Version)

Water Leak Detection System

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

BroadBand PowerShield. User Manual

INSTALLATION INSTRUCTIONS

PL-1, Pocket Logger B

Safety automation solutions

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

INSTRUCTION MANUAL MODEL PCD-88

12-Volt 10-Amp Regulated Power Supply

ADM1TE 5/30A DIN rail single phase two wire energy meter

Model SPDT Relays

Safety Function: Door Monitoring

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Programming Logic controllers

48 SERIES Relay interface modules 10 A

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Utility Distribution Systems

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

WORLD-BEAM QS30 Sensors

Instructions & Safety Information Models A220-20D and A220-20L Version 2

DALI RC BASIC SO. Control unit Operating instructions

SAFETY MANUAL SIL RELAY MODULE

Universal Wireless Effects Controller USER S GUIDE SA115

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

CONFIGURABLE SAFETY RELAYS

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Cross-beam scanning system to detect slim objects. 100 mm in

THE INPUT/OUTPUT SYSTEM. Key Points

SMS 4 / SMS 5 safety mat Product information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User's Guide. Integrating Sound Level Datalogger. Model Introduction

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Comfort Control Relay Panel (CCRP)

GPD 506/P5 Start-up Procedure and Checklist

Installation and Operation Guide PD4600 Series Converter Replacement

PEDAL POWER. User s Manual

TTL to RS232 Adapter User Guide

AC-115 Compact Networked Single Door Controller. Installation and User Manual

A1000 Cheat Sheet (Open Loop Vector)

CONFIGURABLE SAFETY RELAYS

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

NEC Class 2 Power Circuits and Power Supplies

Liquid Carbon Balanced Transportable Headphone Amplifier. Cavalli audio. Copyright Cavalli Audio, LLC All Rights Reserved

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

WE-350 Series ¼ Turn Electric Actuator

Part I - Installation

Leak Detection System

±15 V Current-Limited Power Supply

Transcription:

Emergency Stop Monitoring Safety Relay Model ES-FL-2A R 0630 LISTED Emergency Stop Devices 29YL Monitors two normally-closed emergency stop switch circuits for a contact failure or wiring fault Input monitoring circuit uses a diverse-redundant design Requires a reset routine for controlled re-application of power to the machinery as per ANSI standard B11.20-1991 Two output switching channels for connection to control-reliable power interrupt circuits Auxiliary non-safety contact for status monitoring by process controller Design complies with standards UL991, EN418, and EN954-1(Safety Category 4) UL approved as Category NISD Emergency Stop Device For use in functional stop category 0 applications per NFPA 79 and EN418 Printed in USA P/N 46262K7B p/n 46262 Rev. C

IMPORTANT NOTICE Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instructions. In addition, any questions regarding the use or installation of Banner Emergency Stop Monitoring Safety Relay model ES-FL-2A should be directed to the factory applications department at the telephone numbers or address shown on back cover. The user shall ensure that all machine operators, maintenance personnel, electricians, and supervisors are thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of model ES-FL-2A Emergency Stop Monitoring Safety Relay, and with the machinery it controls. The user and any personnel involved with the installation and use of model ES-FL-2A Emergency Stop Monitoring Safety Relay must be thoroughly familiar with all applicable ANSI/NFPA standards. The standards, listed below, directly address the use of emergency stop systems. Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information for a specific application. The user has the responsibility to ensure that all local, state, and national laws, rules, codes, and regulations relating to the use of this emergency stop monitoring safety relay in any particular application are satisfied. Extreme care is urged that all legal requirements have been met and that all installation and maintenance instructions contained in this manual are followed. U. S. Standards Applicable to Use of Emergency Stop Monitoring Safety Relays ANSI B11 Standards Standards for Construction, Care, and Use of Machine Tools NFPA 79 Electrical Standard for Industrial Machinery 1994 Edition Available from: Safety Director National Machine Tool Builders Association 7901 West park Drive McLean, VA 22102-4269 European Standards Applicable to Use of Emergency Stop Monitoring Safety Relays EN292-1 Safety of Machinery - Basic Concepts, General Principals for Design Part 1: Basic Terminology, Methodology EN292-2 Safety of Machinery - Basic Concepts, General Principals for Design Part 2: Technical Principals and Specifications EN60204-1 Electrical Equipment of Machines: Part 1: General Requirements Available from: Global Engineering Documents 15 Inverness Way East Englewood, CO 80112-5704 Also, request a type C standard for your specific machinery. WARNING Model ES-FL-2A Emergency Stop Monitoring Safety Relay is not a point of operation guarding device, as defined by OSHA regulations. It is necessary to install point of operation guarding devices, such as safety light curtains and/or hard guards, to protect personnel from hazardous machinery. Failure to install point of operation guards on hazardous machinery can result in a dangerous condition which could lead to serious injury or death. page 2

SECTION 1 Product Description The purpose of safety relay model ES-FL-2A is to increase the control reliability of an emergency stop circuit. The ANSI B11.19 standard states: Control reliability of electrical, electronic, or pneumatic systems frequently consists of multiple, independent parallel or series circuitry or components so arranged that any single failure would not significantly affect the stopping performance of the system or the machine tool. If a failure of a component has occurred, this arrangement either sends a stop command to the machine tool or prevents a successive cycle from being initiated. As indicated in Figure 2 or 3, a typical emergency stop switch offers two redundant switching contacts. In a properly-designed machine stop circuit, the opening of either of the two emergency stop contacts immediately removes electrical power from the machine control elements which react to stop hazardous machine motion and/or any other machine hazard. This redundancy of stopping control offered by a two-pole emergency stop switch is the first step towards control reliability. However, failure or defeat of one of the switch contacts to a short-circuit will go undetected, thereby removing the redundancy, and leaving the emergency stop circuit prone to eventual failure. The ES-FL-2A safety relay connects between the emergency stop switch and the machine emergency stop control elements. The emergency stop switch becomes an input to the safety relay. The safety relay monitors the condition of both contacts of the emergency stop switch. The output of the safety relay consists of two redundant output switching channels, each of which is the series connection of two safety relay contacts (K1 and K2 in Figure 2). The Control Reliability section of ANSI B11.19 goes on to state: Electromechanical systems that require redundancy and checking of relay contacts should use relays that are designed with mechanical linkages to provide relation between normally open and normally closed contacts to check the contact operation. Safety relays K1 and K2 in the output circuit of the ES-FL-2A safety relay have mechanically-linked contacts which allow the safety relay circuitry to monitor the contacts of K1 and K2 for failure. If the safety relay detects failure of any contact of either the input emergency stop switch or the output relays, the safety relay output is disabled and cannot be reset. The ES-FL-2A safety relay also provides a necessary reset function. ANSI B11 and NFPA 79 standards require that a reset routine be performed after returning the emergency stop switch to its closed-contact position. This prevents the controlled machinery from restarting by simply closing the emergency stop switch. The two switching output circuits of the safety relay are rated for up to 250V ac at up to 4 amps (resistive load). A low-capacity non-safety auxiliary contact (between terminals #41 and 42) provides a monitoring Status Indicators signal for a process controller. A1 S13 S23 S33 41 13 23 The ES-FL-2A emergency stop monitoring safety relay complies with K2 Energized the following design standards: UL991 Tests for Safety Related Control Employing Solid-state Devices EN418 Emergency Stop Equipment - Functional Aspects, Principals for Design EN954-1 Safety of Machines: Safety-related Parts of Controllers Part 1: General Design Directives (Safety Category 4) The safety relay has indicators for input power and output relay contact status (see Figure 1). There are no adjustments and no user-serviceable parts. See page 7 for information regarding repair service. K1 Energized Input Power on 24V ac/dc In A RESET In B Machine Safety ES-FL-2A K3 K1 K2 A2 S14 S24 S34 42 14 24 Figure 1. ES-FL-2A Status Indicators page 3

SECTION 2 Emergency Stop Switch Requirements As shown in Figure 2 or 3, the emergency stop switch must provide two contacts which are closed when the switch is in the armed position. Once activated, the emergency stop switch must open both contacts. The switch may be returned to the closedcontact position only by a deliberate action such as twisting, pulling, unlocking, etc. Additionally, ANSI B11 standards specify the following switch (i. e. stop control ) requirements: A typical stop control may be a button, cable, trip bar, foot control, or other sensing means. The stop control should be colored red and should be clearly labeled. An emergency stop control shall be provided for each operator control station or position and shall be readily distinguishable from all other operating controls. SECTION 3 Mechanical Installation The model ES-FL-2A safety relay must be installed inside an enclosure. It is not designed for exposed wiring. It is the user s responsibility to house the safety relay in an enclosure with NEMA 3 (IEC IP54) rating, or better. Dimensions of the safety relay are shown in the diagram on page 8. The safety relay mounts directly to standard 35mm DIN rail. SECTION 4 Electrical Installation It is not possible to give exact wiring instructions for a device such as the model ES-FL-2A emergency stop monitoring safety relay which interfaces to a multitude of machine control configurations. The following guidelines are general in nature. Model ES-FL-2A has no delay function. The output relay contacts open (and the monitoring contact closes) within 25 milliseconds from the time that either emergency stop switch contact opens. This classifies the ES-FL-2A as a functional Category 0 emergency stop control as defined by NFPA 79 (National Fire Protection Association Standard for Industrial Machinery) and EN418 (European Standard: Safety of Machinery, Emergency Stop Equipment, Functional Aspects Principles of Design ). CAUTION Always disconnect power from the ES-FL-2A safety relay and all power from the machine being controlled before making any wire connections. Electrical installation and wiring must be made by qualified personnel and must comply with the NEC (National Electrical Code), EN60204-1 and -2, and all applicable local standards and codes. SECTION 4.1 Connection of Emergency Stop Switch Connect the two poles of the emergency stop switch as shown in Figure 2. The switch in Figure 2 is shown in its armed position with both contacts closed. Multiple emergency stop switches connected to one safety relay must use a series connection (see Figure 3 and the warning, below). WARNING Whenever two or more emergency stop switches are connected to the same ES-FL-2A safety relay, contacts of the corresponding pole of each switch must be connected together in series. This series combination is then wired to the respective safety relay input (i.e. to either S13 and S14 or S23 and S24). Never connect the contacts of multiple emergency stop switches in parallel to the ES-FL-2A safety relay inputs. Parallel connection of two or more emergency stop switches to one ES-FL-2A safety relay defeats the switch contact monitoring ability of the safety relay, and creates an unsafe condition which could result in serious injury or death. page 4

Emergency Stop Switch L1 A1 S23 S13 S14 S24 13 23 41 24V ac/dc ES-FL-2A K1 A 4A max. K2 A Internal Redundant Safety Relay Outputs K1 B 4A max. K2 B K3 0.5A max. Non-safety Auxiliary Monitor Contact A2 S33 S34 14 24 MSC1 Monitor Contact Reset Switch MSC2 Monitor Contact L2 MSC1 * MSC2 * 42 Master Stop Control Elements *Arc suppressors (see WARNING) WARNING If arc suppressors are used, they MUST be installed as shown across the actuator of the master stop control elements (MSC1 and MSC2). NEVER install suppressors directly across the output contacts of the ES-FL-2A safety relay. It is possible for suppressors to fail as a short circuit. If installed directly across the output contacts of the safety relay, a short-circuited suppressor will create an unsafe condition which could result in serious injury or death. WARNING (Reference ANSI B11.1 1988, Appendix B4) NEVER wire an intermediate device (for example, a programmable logic controller - PLC), other than a safety relay, between ES-FL-2A safety relay outputs and the master stop control element it switches. To do so sacrifices the control reliability of the control-to-machine interface, and creates an unsafe condition which could result in serious injury or death. Whenever a safety relay is added as an intermediate switching device, a normally-closed forcedguided monitor contact of that relay must be added to the series feedback loop between safety relay terminals S33 and S34. Figure 2. Hookup of ES-FL-2A Emergency Stop Monitoring Safety Relay IMPORTANT Check ALL emergency stop switches, individually, during each checkout procedure. S23 S13 S14 S24 Figure 3. Series Connection of Multiple Emergency Stop Switches page 5

SECTION 4.2 Connection to the Machine to be Controlled The hookup diagram (Figure 2) shows a generic connection of the ES-FL-2A safety relay s two redundant output circuits to master stop control elements MSC1 and MSC2. A master stop control element is defined as an electrically-powered device, external to the ES-FL-2A safety relay, which stops the machinery being controlled by immediate removal of electrical power to the machine and (when necessary) by applying braking to dangerous motion (reference ANSI B11.19, section 5.2: Stop Control ). This stopping action is accomplished by removing power to the actuator of either master stop control element. To satisfy the requirements of Safety Category 4 of pren 954-1, the master stop control elements must be safety relays which offer a normally-closed forced-guided monitor contact. One normally-closed monitor contact from each master stop control element is wired in a series connection together with the normally-open RESET switch (see Figure 2). In operation, if one of the switching contacts of either master stop control element fails in the shorted condition, the associated monitor contact will remain open. Therefore, it will not be possible to reset the ES-FL-2A safety relay. SECTION 4.3 Connection of Reset Switch The reset circuit switch can be any mechanical switch such as a normally-open momentary switch, a two-position key switch, etc. The reset switch must be capable of reliably switching 12 to 18V dc at 40 to 100 milliamps. As shown in Figure 2, and discussed, above, the reset switch must be wired in series with a normally-closed monitor contact of each of the two master stop control elements. This series circuit connects between terminals S33 and S34 of the safety relay. The reset switch must be located outside of the area of dangerous motion, and must be positioned so that any area of dangerous motion may be observed by the switch operator during the reset operation. IMPORTANT NOTE: Any access to dangerous machine motion must be guarded using safety interlocks and/or point-ofoperation presence sensing devices which prevent hazardous machine motion when interrupted. Presence sensing devices, such as safety mats, must be used in any space between machine guards and any danger point which is large enough to allow a person to stand undetected by presence sensing devices. SECTION 4.4 Connection to the Auxiliary Monitor Contact The action of the auxiliary monitor contact, K3, inversely follows the action of the output relays, K1 and K2 when power is applied to the ES-FL-2A safety relay. The contact of K3 is open when the output contacts of K1 and K2 are closed, and vice versa. The K3 auxiliary monitor contact is a light-duty contact to be used only for control functions that are NOT safety-related. A typical use is to communicate the status of the safety relay output to a programmable logic controller (PLC). The switching capacity of the K3 auxiliary monitor contact is 125V ac or V dc maximum at 500 ma maximum (resistive load). Connection to the auxiliary monitor contact is made at terminals 41 and 42 (see Figure 2). CAUTION Before performing the initial checkout procedure, make certain all power is disconnected from the machine to be controlled. Dangerous voltages may be present along the ES-FL-2A wiring barriers whenever power to the machine control elements is on. Exercise extreme caution whenever machine control power is or may be present. Always disconnect power to the machine control elements before opening the enclosure housing the ES-FL-2A. SECTION 5 Initial Checkout Procedure Checkout procedure: 1) Remove power from the machine control elements. 2) Activate the emergency stop switch (open its contacts). page 6

E-Stop Safety Relay 3) Apply input power (only) to the ES-FL-2A safety relay at terminals A1 and A2. Verify that only the Input Power indicator (Figure 1) is on. If either of the other two indicators is on at this point, disconnect the input power and check all wiring. Return to step 2 after the cause of the problem has been corrected. 4) Arm the emergency stop switch (close its contacts). Close the reset switch. The K1 and K2 indicators should remain off. Open the reset switch. The K1 and K2 indicators should both come on at this time. If either indicator comes on before the reset switch is opened, disconnect the input power and check all wiring. Return to step 2 after the cause of the problem has been corrected. 5) Activate the emergency stop switch (open its contacts). The K1 and K2 indicators should turn off, simultaneously. If either indicator does not go off, disconnect the input power and check all wiring. Return to step 2 after the cause of the problem has been corrected. 6) Close the enclosure. Apply power to the machine control elements and perform the Periodic Checkout Procedure (see following information). IMPORTANT NOTE: If more than one emergency stop switch is series-connected to one ES-FL-2A safety relay, the above checkout procedure must be run individually for EACH switch. SECTION 6 Periodic Checkout Procedure We recommend that the emergency stop system be checked at each shift change or machine setup change. 1) With the machine running, engage the emergency stop switch (open its contacts). Verify that the machine stops. 2) Return the emergency stop switch to its closed-contact position. Close and then open the reset switch. Verify that the machine restarts. IMPORTANT NOTE: If two or more emergency stop switches are series-connected to one ES-FL-2A safety relay, this test must be individually run for EACH switch. SECTION 7 Repairs NOTE: Do not attempt any repairs to the ES-FL-2A Emergency Stop Monitoring Safety Relay. It contains no field-replaceable components. Return the safety relay to the factory for warranty repair or replacement: Banner Engineering Corp. Repair Department 715 North County Rd. 19 Aberdeen, SD 57401 Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY WARRANTY: Banner LOSSES, Engineering warrants it products CONSEQUENTIAL to be free from defects for one year. EXTRA COSTS, EXPENSES, LOSS Corporation OF PROFITS, OR ANY INCIDENTAL, OR SPECIAL DAMAGES ANY PRODUCT DEFECT OR FROM USE ORany INABILITY THE PRODUCT, Banner RESULTING EngineeringFROM Corporation will repair or replace, freethe of charge, producttoofuse its manufacture found WHETHER ARISING at INthe CONTRACT WARRANTY, TORT, STRICT LIABILITY, NEGLIGENCE, OR does not to be defective time it isorreturned to thestatute, factory during the warranty period. This warranty OTHERWISE. cover damage or liability for the improper application of Banner products. This warranty is in lieu of any Banner Corp. reserves theorright to change, modify or improve the design of the product without otherengineering warranty either expressed implied. assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. page 7

Supply Voltage and Current Supply Protection Circuitry Output Configuration Product Specifications 24V ac/dc ±15% at 250mA maximum; 10% maximum ripple for dc operation Protected against transient voltages and reverse polarity (dc hookup is without regard to polarity) Outputs (K1 and K2): two redundant (i. e. total of four) safety relay (forced-guided) contacts Contact ratings: Maximum voltage: 250V ac or 250V dc Maximum current: 4A ac or dc (resistive load) Maximum power: 1000VA, 20 watts Mechanical life: 10,000,000 operations Electrical life: 100,000 at full resistive load NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts (see Warning on page 5). Auxiliary Monitor Output (K3): One non-safety relay contact Maximum switching voltage: 125V ac or V dc Maximum switching current: 500 ma (resistive load) Output Response Time Input Requirements Status Indicators Housing 25 milliseconds maximum Emergency stop switch must have two normally closed contacts each capable of switching 40 to 100mA @ 12 to 18V dc. Reset switch must have one normally open contact capable of switching 40 to 100mA @ 12 to 18V dc. 3 green LED indicators: Power ON K1 energized K2 energized Polycarbonate. Rated NEMA 1 (IEC IP20) Mounting Mounts to standard 35 mm DIN rail track. Relay safety relay must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better. Vibration Resistance 10 to 55Hz @.35mm displacement per IEC 68-2-6 Operating Temperature Dimensions Certifications 0 to 50 C ( 32 to 122 F) See diagram, below R LISTED Emergency Stop Devices 29YL 0630 DIN Mounting Tab (Supplied) 35.0 mm (1.38 in) DIN Mounting Slot 110.0 mm (4.33 in) 45.0 mm (1.77 in) 75.0 mm (2.95 in) Figure 4. E-Stop Enclosure Dimensions Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications) (612) 544-3573