9454/9455 Installation and User Guide

Similar documents
9452/9453 Installation and User Guide

9448 Installation and User Guide

500r+ Installation and User Guide

TS510 & TS500. Installation & User Guide. Compatible Equipment

ACTIVE 5 ENGINEERING MANUAL

CONTENTS 4. HOW TO UNSET THE PANEL...7

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.

IMPORTANT USER INFORMATION

How To Set A Timer On A Gg System

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

HARDWIRED CONTROL PANELS

ACP10 10 Zone Intruder Alarm System

Intruder alarm system Engineering Information

User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5

Intruder alarm system Engineering Information

SECURIT 800L+ CONTROL PANEL

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12

astec Integrated Alarm System USER GUIDE

INSTALLATION MANUAL CONTENTS

Control/Communicator Installation Manual

User s Information Guide R1A

Using your LED Plus keypad

User Guide Premier Elite 24/48/88/168/640

Master User Guide Premier Elite Series

User.QXD 09/05/00 14:47 Page 1 Gardtec /582 User Instructions

Programming & Installation PIEZO WARNING. EN : 2009 EN : 2008 EN : 2005 Security Grade 2 Environmental Class II RINS1347-2

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

USER GUIDE HARDWIRED CONTROL UNIT

SCORPION. micron security products

TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC

INSTALLATION AND PROGRAMMING GUIDE HARDWIRED CONTROL PANEL

ICP-CC488. Installation Guide ICP-CC488 Control Panel

SECURIT 800L+ CONTROL PANEL

Intruder alarm system Operating Instructions

IDS X-Series User Manual D Issued July 2012

9x5x PROGRAMMING GUIDE

How To Control A Car Alarm On A Car With A Remote Control System

Digital Keypad Use s Manual

CA60 Plus Software Version 3.1 User Manual May 2000

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Master User Guide Premier Elite 24/48/88/168/640

Security System User Guide

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Speech Dialler Engineering Information

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

Security System. User Guide for the LED Command Center

MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7

UNSET TAMPER FINAL EXIT

NetworX NX-6V2. LED Keypad User Manual

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide

PRT3 Printer Module: ASCII Protocol Programming Instructions

Users Guide to Keypad Functions

AC-115 Compact Networked Single Door Controller. Installation and User Manual

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

Solution-16 Operators Manual ISSUE 1.60

i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

SECURITY SYSTEM NOTES

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS EN Security Grade 2 Environmental Class 2

Speech Dialler Engineering Information

NESS D Zone Control Panel and Dialler OWNER S MANUAL

INSTALLATION MANUAL PC2525. Version 1.1

INSTALLATION GUIDE. FCC ID NOTICE

Secure Keypads for access control

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

Security System Installation and Programming Guide

SECURITY SYSTEM NOTES

Galaxy 2 Series. User Guide. Honeywell Security

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

NetworX Series. NX-216E Zone Expander Module Installation and Startup

Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222

FIREDEX Conventional Fire Panels

Quick Installation Guide LCD GSM ALARM SYSTEM LH

Installation Manual for D1110 DigiCom2

Solution 862 Operators Manual. Issue 1.00

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

WIRELESS HOME ALARM SYSTEM (WHA1)

Destiny Destiny Owners Manual

HILLS Series LED Code Pad User Manual

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide

ICP-CP500. User's Guide ICP-CP500 Codepads

Solution 880 Operators Manual ISSUE 1.10

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

1R / 4-BUTTON SERIES

STERLING 10. Control Panel with Remote Keypads USER MANUAL (ICON and LCD) Pyronix Limited Pyronix House Braithwell Way Hellaby, Rotherham S66 8QY, UK

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

PA4. 4 Zone Wired Intruder Alarm System. Installation & Operating Manual. MAINS CLEAR 24Hr. Zone 1 Zone 2 Zone 3 Zone 4

THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL. Security Control Panels with Integrated Communicator. Issue 6

HILLS Series LED Code Pad User Manual

Automatic Telephone Dialer TD-101(W)

DESTINY OWNER S MANUAL

System Introduction S E C T I O N 1

Transcription:

9454/9455 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496331 Issue 1 1 of 12

9454/5 Introduction The 9454 and 9455 are fully programmable control units designed to meet the requirements of larger domestic and medium commercial installations. A basic system comprises a main control unit complete with built-in keypad, The control unit houses the system electronics, power supply, battery and remote signalling device (if fitted). A numeric keypad and row of indicators (LEDs) on the outside of the unit allow the user and installer to operate the system. Remote keypads provide the user with the facility to set and unset the system from strategic locations within the premises and allow the installer to program the system. Up to TWO remote keypads may be connected to a system. The keypads also have an optional key press PA facility. The 9454 is a five zone system, with three open collector type outputs. The 9455 is a six zone system, with three single pole relay outputs. In both systems, one output is timed (sounders) one is untimed (strobe) and one is fully programmable. If required the 9455 can incorporate a keyswitch for full setting and unsetting. Technical Specification Zones 9454: Five plus entry/exit and PA, all closed circuit. With individual tamper. 9455: Six plus entry/exit and PA, all FSL. Display LED. Keypads 1 built-in plus up to two remote keypads (9425). Expansion None. BS 4737 Full Spec. Log 9454: 15 events. 9455: 15 events. Panel Siren Yes. Extension Spkr 9040. 1 max. Battery 6.5 Ah. 12 V Power 9454 Quiescent Panel 50mA. 9455 quiescent panel 65mA. 9425 RKP = 40mA. 12V Aux Output 500mA. Dimensions Panel: h x w x d 163 x 257 x 72mm. RKP: h x w x d 115 x 115 x 28mm. Weight Comms Output Panel 1.7Kg approx. 9454: PA, Intruder, Open/Close. 9455: PA, Intruder, Open/Close. 2 of 12 496331 Issue 1

9454/5 Wiring Figure 1. 9454 PCB Layout Figure 2. 9455 PCB Layout 496331 Issue 1 3 of 12

Communicator Output Pins 9454/5 Figure 3. Wiring a Bell to the 9455. Notes: 1. Bell O/P programmed as normally closed (SCB). 2. Link TR to0v if no external tamper is required. 3. Connect all bell wiring to the control panel with the exception of the +12V Aux supply, until initial power-up is complete, then final connections can be made. 4. You can fit a maximum of two 9040 16Ohm speakers to the 9455 if the internal speaker is disconnected. 5. The SCB module shown is a typical example only. See manufacturers instructions supplied with individual units for further information on wiring diagrams. Communicator Output Pins Pin on panel Function Colour Pin on communicator Pin 1 PA Red ST2 Pin2 Line Monitor Input Blue O/P Pin 3 Intruder Yellow ST3 Pin 4 Open/Close Black ST4 Pin 5 +12V Brown 12V Pin 6 0V Orange 0V 4 of 12 496331 Issue 1

9454/5 Keypad Wiring Notes: 1. Pins 3 and 4 are 5V positive removed in alarm to trigger. 2. Pin 2 is a 12V +ve input for Line Fault. 3. If a communicator is fitted and has an output for line fault, connecting a +ve to the Line Monitor Input will reduce any programmed bell delay to zero and give a visual indication on the panel LED (LF). 4. If a communicator is not fitted remove the communicator wiring harness from the main pcb. Keypad Wiring Figure 4. Keypad Connection. Notes: 1. Maximum cable distance: Daisy chain = 300m, Star Wire = 100m per leg. 2. Do not wire the extension speaker or circuit wiring within the same cable as the remote keypad. Initial Start Up Programming Before applying power to the control panel or end station, ensure that all used circuits are connected. The control panel or end station lid switch should be defeated or closed and NO power connections to detectors, sounders or battery should be made at this stage. 496331 Issue 1 5 of 12

Programming Commands 9454/5 Note: If connections to the bell and AUX power are made when the system is powered up, damage to the main pcb may occur. 1. Apply mains to the control panel or end station. The green Power and Day LED will illuminate and the internal sounder will sound. 2. Key-in the factory default customer code 1234. The internal sounder will stop and the Tamper, Service and Fault LEDs will be flashing. 3. Key-in the factory default engineer code, 0 followed by ENTER then 7890. The Fault and Service LEDs will flash and the internal sounder will be bleeping. 4. Open the control panel or end station lid. The internal sounder stops bleeping and the Service LED will be steady. Make connections to AUX power, stand-by battery and connections to SAB. Proceed to program the system. Note: If an SAB/SCB module is fitted within the bell, it will continue to ring until the panel supply is connected and until the bell cover lid tamper switch is closed. Programming Commands To change the factory default program, use the commands listed in this section as follows: 1. Enter the command number. 2. Enter one or more digits to give the new program. 3. Press ENTER. The panel will give a double bleep to show that it has accepted the command. If you enter the command incorrectly the panel gives a single tone. Default Settings When delivered from the factory, the panel is programmed as follows: Zone 1, Entry Route Part Set zone. Zone 2, Normal alarm, active in Part Set, Omit allowed. Zone 3, Normal Alarm, active in Part Set, Omit allowed. Zone 4, Normal Alarm, active in Part Set, Omit allowed. Zone 5, Normal alarm. Zone 6, (9455 only) Normal Alarm. Zone 7(E/E) Part set. User code 1234. 6 of 12 496331 Issue 1

9454/5 Engineering Program Commands Engineering Program Commands To change Key in: Followed by + ENTER Default Zones 1-5(6) 01-05(6) 0 = Not used 1 = Normal Alarm 2 = 24 Hour Alarm 3 = Entry Route 4 = 9454: Dbl knock: 9455: Fire zone 5 = 9454: Chime. 9455: Dbl knock 6 = 9454: Part set zone. 9455:Chime 7 = 9455: Part set zone OMIT = Omit Allowed Entry/exit zone options 07 0 = Reset to none 5 = 9454: Chime 6 = 9454: Part set zone. 9455: Chime 7 = 9455: Part set zone. Programmable Output 11 18 = 9454: PIR set latch y 29 = 9454: Shock sensor reset 19 = 9455: PIR set latch y 28 = 9455: Shock sensor reset 39 = 9455: Tamper alarm function 49 = 9455: System part set Engineer Access 20 Any 4 digit code 7890 Bell output type 21 0 = 9454: SAB. 9455: normally open y(9454) 1 = 9454: SCB. 9455: normally closed y(9455) Internal sounder 22 1 = Follows strobe 0 = Follows bell y PA 30 0 = Audible Alarm y 1 = Silent Alarm System Reset 31 0 = Customer Reset y 1 = Engineer Reset Abort facility 32 0 = Disabled y 1 = Enabled Keypad PA 33 0 = Disabled y 1 = Enabled System status 34 0 = LEDs ON y(9455) 1 = LEDs OFF y(9454) Exit Mode 35 0 = Timed or Terminated y 1 = Final Door Set Control panel ET and 36 0 = Exit terminator y RKP I/P function (9455 only) 1 = Keyswitch set Rearm 40 0 = Never y 1 = Once 2 = Twice 3 = Three times 4 = Always 496331 Issue 1 7 of 12

Engineering Program Commands 9454/5 To change Key in: Followed by + ENTER Default External sounder delay 41 0 = Nil y 1 = 1.5 mins 2 = 3 mins 3 = 5 mins 4 = 10 mins 5 = 15 mins 6 = 20 mins 7 = No duration Ext. sounder duration 42 0 = Nil 1 = 1.5 mins 2 = 3 mins y 3 = 5 mins 4 = 10 mins 5 = 15 mins 6 = 20 mins 7 = No duration Entry Time 43 0 = Continuous 1 = 10s 2 = 20s y 3 = 30s 4 = 60s 5 = 90s 6 = 120s Exit Time 44 0 = Continuous 1 = 10s y 2 = 20s 3 = 30s 4 = 60s 5 = 90s 6 = 120s CSID code 50 nnnn (key in four digit code) Part Set Entry/Exit 60 0 = As Final Exit y 1 = Normal Alarm Part Set Entry Response 61 0 = As Entry Route 1 = Start Entry Timer y Part Set Exit Mode 62 0 = As Full Set 1 = 10 Second Set y 2 = Instant Set Part Set Alarm Response 63 0 = Local (No comms) y 1 = Full Alarm Engineer Log 90 1 see earlier events. 3 to see more recent events. ENTER to quit log. (15 events max.) 8 of 12 496331 Issue 1

9454/5 Refresh NVM To change Key in: Followed by + ENTER Default External Sounder 91 ENTER to stop test. Strobe 92 ENTER to stop test. Internal Sounder 93 ENTER to stop test. Test keypad LEDs 94 ENTER to stop test Programmable output 95 ENTER to stop test. Walk Test 97 ENTER to stop test. Load Factory Defaults 98 Leave Engineering Mode 99 Refresh NVM (System Memory Chip) The 9454/5 control panels have a Non Volatile Memory chip which retains all programmed information and access codes. If the system suffers a total power failure, the NVM will retain all information and the panel will only require powering up and resetting. However, if the end user forgets the user access code or the installer wants to return the panel to the factory programmed settings, continue as follows: 1. Power down the control panel, mains and battery. 2. Find the RST pins, located to the middle of the control pcb. 3. Place a small screwdriver blade to short between the RST pins (on the 9455 also use a short length of wire to short out the Kick Start pins). With the blade still across the pins, power up the control panel battery first, then Mains. All the LEDs will flash. 4. Remove the screwdriver blade. The control panel loads the factory default codes. 5. Key-in 1234, then press 0 Enter 7890. Momentarily close, then open up control panel lid. Re-program the system. Engineer Reset When an engineer requires to reset the system e.g., after an alarm condition, the control panel or end station lid does not require to be opened. Enter the engineer code to reset the system, followed by 99. 496331 Issue 1 9 of 12

Fault Finding 9454/5 To Re-Enter Programming Mode 1. Press 0 then Enter. 2. Key in the Engineer Access Code. The Fault and Service LEDs flash and the internal sounder starts bleeping. 3. Open the control panel lid. The internal sounder stops bleeping and the Service LED glows steadily. The system is now in programming mode. To Leave Programming Mode 1. Close the panel lid. 2. Key in 99. Fault Finding Under normal conditions, the Fault, Service and Alarm LEDs will not be illuminated. Only the Mains, Day Full and Part Set LEDs should be illuminated during normal use of the system. Any other LEDs which are illuminated or flashing, signify a fault or alarm condition. Note: The Mains LED will be illuminated permanently. Any condition indicated by a combination of the Fault, Service or Alarm LEDs are to be considered an abnormal condition, as shown on the opposite page: 10 of 12 496331 Issue 1

9454/5 Fault Finding 496331 Issue 1 11 of 12

9454/5 Full Set System Part Set System Unset/Reset System Omit zone User Commands 1 + ENTER + User code 2 + ENTER + User code User code 1 (or 2) + ENTER + User code + OMIT + zone number (repeat OMIT + zone number for other zones as required). Omit 24 hr zone OMIT + ENTER + User code + zone number (+ zone number for other zones as required) Change User code 4 + ENTER + Old code + Old code (the system beeps twice)+ New code (the system beeps twice) Read Log 5 + ENTER + User code 1 to read earlier events 3 to read later events ENTER to leave the log Chime On/Off 7 + ENTER + User code Bell Test 8 + ENTER + User code Walk Test 9 + ENTER + User code ENTER to end the test 12 of 12 496331 Issue 1