Automated Pensky Martens Closed Cup Flash Point Analyzer HFP 339

Similar documents
Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Flash Point. Test Methods

ADU 5. Automatic Distillation Unit

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Multi-Range Programmable DC Power Supplies 9115 Series

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Repeaters and Mimics Data Sheet

Incubator with mechanical convection

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Portable digital microprocessor thermometers with interchangeable probes

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

KNC Model 3666 Automatic Pressure Calibration System

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Multi-Range Programmable DC Power Supplies 9115 Series

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Test equipment for temperature and its reduction

Vacuum drying oven for non-flammable solvents

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

T0118 T2118 T3118. Instruction Manual

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Penetration. Test Methods

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

DC Electronic Loads 8500 series

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

CYMAQ Marking System AS200 + DS7050 N-14

Pin & Vee Block Test Machine

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

804 Ti Stand. Manual EN

Pressure transmitter For general industrial applications Model A-10

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Hand-held thermometer Model CTH7000

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Mini USB and USB 2.0-IP67 Connector System

Melting Point Apparatus

Heating oven with mechanical control

Viscotherm sensor electronic differential pressure transmitter electronic viscosity controller electric control valve power supply unit starter box

Digital inductive conductivity transmitter

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Electric Rotary Actuator - On/Off or programmable control actuator

PIEZOMETER AIRFLOW MEASURING RING

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Product Information Fire alarm panel 8000 C

Ground Resistance Clamp On Tester

Electronic Control Devices The European Product Catalogue 2007

Material test chamber with mechanical convection

Penetration Test Methods

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Measurement Solutions for Refrigeration Technology.

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers

Hydraulic Control Solutions

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Digital input modules

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

Turbine Flow Sensor Series VTR

Wahl C50 Calibrator FEATURES

FALEX Four-Ball Extreme Pressure Test Machine

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Multiple flasks. Easy to adapt. Stuart range of heating blocks

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

DTW Works Master Specification Version 2006


DENSITY MEASURING SYSTEMS

Combi switchbox with integrated 3/2 way pilot valve

How To Use An Iphone With A Memory Card (I2) For A Week

TR Series Surface Roughness Tester for workshop and laboratory

Spare Parts List M96A.24SM/B M96A.28SM/B

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Duct Humidity Transmitter

SECTION DETECTION AND ALARM

O C M III. Open Channel Flow Monitor

Climate chamber with illumination

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Plug-in relays Mini ISO relays

430 Power/Electronics Replacement

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Precision digital pressure gauge Model CPG1500

How To Use A Ds340 (Dsp)

BB-18 Black Body High Vacuum System Technical Description

Specials. designed. 3rd edition 2015 English. for scientists 1

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

4-Channel Thermometer / Datalogger

J TB/TW Temperature limiter, temperature monitor

EBS852 (Contrac) Power Electronic Unit

Transcription:

Standard Quotation No. Automated Pensky Martens Closed Cup Flash Point Analyzer HFP 339 Fuels have different components from light to heavy hydrocarbons. The flashpoint method gives information about the light components by their tendency to flash. It further gives important information on safety and shipping regulations. The HFP 339 is a fully automated instrument which perfectly mimics the manual process as described in the following methods: ASTM D 93 A&B, ISO 2719 A&B, EN ISO 2719 A&B, DIN EN ISO 2719 A&B, NF EN ISO 2719 A&B, IP 34 A&B, JIS K 2265, DIN 51758 The Instrument has a built in microprocessor system which controls all functions of the unit. Operation of the instrument is done via easy to read VF-Display and a solvent resistant alpha numeric keypad. This easy to use man machine interface lets the operator quickly initiate standard flash point testing, change test parameters to run customized protocols, run the systems diagnostics, and recall or print test results. Main Features Flash point determinations may be run using standard test method or customized test protocols 6 Standard programs and 3 user-defined test programs. Tests for samples with unknown flash points. Automatically corrects results to barometric pressure. Memorizes the last 9 Flash Point results Built-in safety functions Built in fire detection system with audible alarm and external alarm relay contact. Thermal flash point detection eliminates any interference from water or silicone containing samples. Electric ignition (standard) and Gas ignition (option) HFP339 Technical Offer 22.8.2006 Page 1 of 15

Technical details Standards ASTM D 93 Methods A&B, ISO 2719 A&B, EN ISO 2719 A&B, DIN EN ISO 2719 A&B, NF EN ISO 2719 A&B, IP 34 A&B, JIS K 2265, DIN 51758 Configuration Stand alone automated Pensky Martens flashpoint analyzer HFP 339 Sample Temperature Measurement Cabinet/Chassis Sample Heating System Heating Rate Control Heating Rate Sample Stirrer Igniter Ignition Interval Barometric Pressure Flash Detection System Glass Pt 100 probe, Metal Pt 100 available as a plug in accessory. Temperature range: +0 +400 C, resolution 0.1 C +32 +752 F, resolution 0.1 F Each measurement program can be individually programmed in C or F. The system perfectly mimics ASTM 9C/9F, 88C/88F and 10C/10F-standardthermometers. Probe can be calibrated on the display Automatic calibrating of the electronic circuit with integrated, high precision calibration resistors eliminates temperature and long term drift of the temperature measuring unit. All steel, baked epoxy resin coated: electromagnetic isolation, solvent resistant. Width only 25 cm (9.85 ) 950 W, conforms to CE safety specification. Air cooled at the end of the test. Automatic proven algorithm controls temperature of heater block and sample. Per appropriate method or user-defined programmable from 0.5 to 14 C/min for individual measurement programs. Stepper motor operated stirring. Per appropriate method or user-defined programmable from 20 to 255 revolutions/min for individual measurement programs. Reliable electric igniter comes as a standard. The unit monitors the correct function of the electric igniter. Gas ignition is optional available. The Gas flame is automatically ignited by an auxiliary electric igniter. Per appropriate method or user-defined programmable in 0.5 to 5 C steps Built in barometric pressure sensor makes automatic pressure correction of the flash point temperature data. Indicated as mbar, hpa, kpa, mmhg or Torr. Thermal detection system to eliminate interference from water or silicone containing samples. Display A 2 line 20 character VF-Display gives information about the status of the HFP 339. The HFP 339 lets you quickly initiate standard flashpoint point tests. You are also able to easily calibrate the instrument, generate methods and review past test results. Keyboard Operation of the instrument is done via a 25 button solvent resistant foil keypad. Result Documentation Printer Test results are displayed on the VF-Display and can also be output automatically or on demand to an optional printer or computer system (LIM). A typical report includes the Sample ID, Date and Time, Measurement Program, expected Flash Point, measured and corrected Flash Point and barometric pressure. Any printer with CENTRONICS interface and ASCII character set may be HFP339 Technical Offer 22.8.2006 Page 2 of 15

Printer and LIMS crosslinking of several units Communications Results memory Test Programs used. To save space a small footprint needle ticket printer is recommended (see accessories). In order to connect several units to one PC with a Laboratory Information System (LIMS) or to a printer, the units can be linked together as a Herzog Token Ring network (HTR). It is possible to link up to 16 units. Connect with cable (626-082) to the socket HTR at the back of the instrument. Serial transmission of all data via RS232 and HTR (Herzog Token Ring) protocol. The instrument stores the last 9 test results with Sample number and flash point temperature. 6 standard programs and 3 user defined programs Safety Features Password Protection Fire Extinguisher Fire Safety A built-in fire sensor located next to the lid cover alerts instantly to flames outside the flash cup. A potential-free alarm relay contact is also available to link the HFP to a fire suppression system or alarm bell. Safety pre test By doing safety pre dip ins the unit can detect high volatile contamination in normally high flash point samples and avoid a risk of fire Alarm Functions Automatic detection of method or safety violations. User selects test termination or alarm message Calibration and Diagnostics Password protection is available to prevent inadvertent changing of programmed test parameters and calibration. The instrument incorporates a comprehensive diagnostic program which allows you to check every key component and assembly. In addition, it features a selfcalibrating sample temperature measuring system that automatically compensates for drift. Any probe deviation can be corrected on screen calibration of resistance thermometer. Operating Requirements Electrical 115V or 230VAC ±10% switchable; 50-60Hz ; 1100 W Ambient Conditions Temperature: max. 10 to 35 C; recomm. 15 to 25 C Humidity: 80% rel. at 35 C Storage temperature: -15 to +55 C Dimensions 25 cm (9.85 ) wide, 56 cm (22 ) deep, 51 cm (20.1 ) tall Weight 25kg, (55 lb) HFP339 Technical Offer 22.8.2006 Page 3 of 15

Ordering information: Order No. Description Picture Price 03391-000-01 HFP 339 Pensky Martens 230V, el. igniter HERZOG - automatic flash point tester acc. to Pensky Martens. Compact single unit with VF- Display and alphanumeric keypad: Electric ignition 230 V, 50-60 Hz. 1 x 101-052 Power cord with Continental European IEC/DIN plug. Accessories included: 1 x 820-268 Instruction manual 1 x 302-026 Test cup Pensky Martens 1 x 636-069 Pt 100 for sample temperatures up to +400 C 1 x 636-095 Flashpoint sensor with plug 1 x 103-060 Test cover, PM, for electric igniter and thermal flash detection device. 2 x 620-113 Electric igniters 1 x 628-041 Thermo fuses for fire sensor 1 x 101-029 Cover-handle PM 1 x 326-070 Gauge as igniter simulator 1 x 326-072 Igniter dip in level adjustment tool 1 x 402-120 Gauge for adjustment of dip in level 1 x 101-029 Cover handle for HFP 339 1 x 307-006 Drip cup, Pensky Martens 1 x 303-001 Coupling for stirrer, HFP 339 1 x 412-221 Set of hexagonal wrenches: 1.5; 2; 2.5; 3; 4; 5mm. 03391-000-02 HFP 339 Pensky Martens 115V, el. igniter HERZOG - automatic flash point tester acc. to Pensky Martens. Compact single unit with VF- Display and alphanumeric keypad: Electric ignition 115 V, 50-60 Hz 1 x 411-021 Power cord with US NEMA 5-15 plug. Accessories included as for 03391-000-01 HFP339 Technical Offer 22.8.2006 Page 4 of 15

Order No. Description Picture Price 03391-000-03 HFP 339 Pensky Martens 230V, gas igniter HERZOG - automatic flash point tester acc. to Pensky Martens. Compact single unit with VF- Display and alphanumeric keypad: Gas ignition 230 V, 50-60 Hz 1 x 101-052 Power cord with Continental European IEC/DIN plug Accessories included: 1 x 820-268 Instruction manual 1 x 302-026 Test cup Pensky Martens 1 x 636-069 Pt 100 for sample temperatures up to +400 C 1 x 636-095 Flashpoint sensor with plug 1 x 103-061 Test cover, PM, for gas igniter 2 x 620-114 Electric igniters with closed filament 1 x 120-052 Straight gas connection 1 x 628-041 Thermo fuses for fire sensor 1 x 101-029 Cover handle for HFP 339 1 x 326-070 Gauge as igniter simulator 1 x 326-072 Igniter dip in level adjustment tool 1 x 402-120 Gauge for adjustment of dip in level 1 x 307-006 Drip cup, Pensky Martens 1 x 303-001 Coupling for stirrer, HFP 339 1 x 412-221 Set of hexagonal wrenches: 1.5; 2; 2.5; 3; 4; 5mm. 03391-000-04 HFP 339 Pensky Martens 115V, gas igniter HERZOG - automatic flash point tester acc. to Pensky Martens. Compact single unit with VF- Display and alphanumeric keypad: Gas ignition 115 V, 50-60Hz 1 x 411-021 Power cord with US NEMA 5-15 plug Accessories included as 03391-000-03 HFP339 Technical Offer 22.8.2006 Page 5 of 15

Accessories: Order No. Description Picture Price 110-191 103-061 620-114 626-260 Gas supply accessory set for HFP 339 Ready to connect an external low pressure gas source and supply the gas ignition test cover with gas. In addition need following Parts! Test cover, PM, for gas igniter Electric igniters with closed filament MV-connection cable 636-103 Stainless steel sample thermometer probe up to +400 C HFP 339 101-214 Matrix dot printer, 40 columns, using endless paper roll of 76mm width, Centronics interface, Dimensions: 156 mm (W) x 248 mm (D) x 132 mm (H), 100-230 VAC, 24W, Power cord with Continental European IEC/DIN plug. Centronics Printer cable not included 101-212 Ink ribbon for Matrix dot printer 101-214 No Picture 101-185 Paper rolls (10 pcs.) for Matrix dot printer printer 101-214 76 mm x 60 x 12mm 101-137 Ink jet printer with English and German manual, ASCII compatible, for 100 230VAC, Power cord with Continental European IEC/DIN plug. Centronics Printer cable not included 626-029 Printer connection cable (Centronics) HFP339 Technical Offer 22.8.2006 Page 6 of 15

Order No. Description Picture Price 101-145 Pressure calibration instrument. U-tube system that creates a gauge pressure of 0 40 mbar 302-029 Special low volume (20 ml) sample test cup for Pensky Martens, HFP 339 103-066 Special cover for low sample volume (20 ml) for Pensky Martens, HFP 339 electric ignition 302-027 Cooling test cup Pensky Martens for flash points below +40 C (cooled with dry-ice) 302-028 Cooling test cup Pensky Martens, for flash points below +40 C ( with built on cooling coil for cooling with external chiller) HFP339 Technical Offer 22.8.2006 Page 7 of 15

Order No. Description Picture Price 101-193 Pt100 probe simulator box 0 to +400 C with 6 fixed temperatures, accuracy better 0,2%, including 4-wire connecting cable 626-122 with connector used for Herzog Pt100 probes 01000-329-51 Certified Reference Material, ASTM D93 Flash point Pensky Martens appr. +65 C, with certificate, 255 ml diesel fuel 01000-329-52 Certified Reference Material (CRM), Flash point Pensky Martens appr. +95,3 C, approx. 255 ml 01000-329-53 Certified Reference Material, ASTM D93 Flash point Pensky Martens appr. +215 C, with certificate, 255 ml base oil 634-198 Plug, 6-pol. mating halve for fire alarm outlet HFP 339 626-261 Cable for alarm outlet. 326-098 Angled gas connection without threat for HFP 339 226-205 Cup holder Additional Holder for storage the cup on the left side of the unit. HFP339 Technical Offer 22.8.2006 Page 8 of 15

Recommended spare parts for appr. 2 years of operation Order No. Description Qty Picture Price 302-026 Pensky Martens Test cup, brass 2 303-001 Coupling for stirrer HFP 339 2 618-036 Stepper motor f. stirring HFP 339 1 618-133 Stepper motor f. dip in HFP 339 1 636-125 Temperature sensor for heating block HFP339 1 645-070 Bottom heater 450 W/ HFP 339 2 645-032 Wall heater 500W/MP HFP 339 1 620-113 Electric igniter with open filament for HFP 36x family and HFP 339 10 HFP339 Technical Offer 22.8.2006 Page 9 of 15

Order No. Description Qty Picture Price 628-007 Fuse 10 A MT 10 628-021 Fuse 2 A MT 10 628-023 Fuse 6.3 A MT 10 628-025 Fuse 4 A MT 10 628-041 Fire sensor 5 636-069 Sample temperature probe up to 400 C HFP 339 4 636-095 Flash sensor for water containing samples, with plug 1 613-055 Solid state relay 4A 230V 1 HFP339 Technical Offer 22.8.2006 Page 10 of 15

Other spare parts: Order No. Description Picture Price 101-029 Cover-handle PM HFP 339 103-060 Test cover PM for HFP 339 with provisions for thermal flash detection and for electric ignition 103-061 Test cover PM for HFP 339 with provisions for thermal flash detection and for gas ignition 326-070 Gauge as igniter simulator HFP339 Technical Offer 22.8.2006 Page 11 of 15

Order No. Description Picture Price 326-072 Igniter dip in level adjustment tool 307-006 Drip cup, Pensky Martens 402-120 Gauge for adjustment of dip in level 627-098 Blower 645-070 Bottom-Heater 108-266 Push-pull rod to open the cover shutter 412-209 Cardanic suspension for 108-266 326-210 Driving device with suspension for 108-266 HFP339 Technical Offer 22.8.2006 Page 12 of 15

Order No. Description Picture Price 620-114 Electric igniter with closed filament to re-ignite the gas ignition 126-050 Foil keypad 650-551 Temperature measurement P.C.B., with software 607-068 Motor control PCB for dip in system, without EPROM 650-140 EPROM with latest HFP339 software for 607-068 607-215 Motor control PCB for stirrer, without EPROM 650-140 EPROM wit latest HFP339 software for 607-215 607-082 Display 607-257 Keyboard Adapter HFP339 Technical Offer 22.8.2006 Page 13 of 15

Order No. Description Picture Price 607-258 Adapter for Measuring board 607-259 Interface board 607-260 Power supply board 607-252 CPU board 607-211 Pressure sensor and flash detection P.C.B. 617-151 Main switch 619-013 Varistor metallic oxide for mains protection 625-084 Transformer for electric ignition HFP339 Technical Offer 22.8.2006 Page 14 of 15

Order No. Description Picture Price 625-126 Transformer 230/115V-24V/8V/HFP339 HFP339 Technical Offer 22.8.2006 Page 15 of 15