Frequency Counters SR620 Universal time interval and frequency counter

Similar documents
FFT Spectrum Analyzers

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

How To Use A High Definition Oscilloscope

Impedance 50 (75 connectors via adapters)

Agilent E5100A Network Analyzer

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series

Description: Multiparameter System (4 or 8 channels)

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

Analogue/Digital Analogue and Differential Oscilloscopes

Agilent 8904A Multifunction Synthesizer dc to 600 khz

khz to 2.7 GHz Spectrum Analyzer

One Port Network Analyzer

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

Power Amplifier Gain Compression Measurements

R&S ZVA Vector Network Analyzer Specifications

Arbitrary/Function Generators AFG3000C Series Datasheet

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

MicroMag3 3-Axis Magnetic Sensor Module

PCM Encoding and Decoding:

Mach 5 User s Manual Revision 2.0 1

User Manual. TDS 200-Series Digital Real-Time Oscilloscope

Lab 1: The Digital Oscilloscope

DAC Digital To Analog Converter

200 MHz 2[4] Channel Digital Oscilloscope HMO2022 [HMO2024] 150 MHz 2[4] Channel Digital Oscilloscope HMO1522 [HMO1524]

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Analog and Digital Signals, Time and Frequency Representation of Signals

PERF10 Rubidium Atomic Clock

A Laser Scanner Chip Set for Accurate Perception Systems

NEW PRODUCT ANNOUCEMENT

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Physical Specifications (Custom design available.)

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

Electrical Resonance

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C

LM118/LM218/LM318 Operational Amplifiers

FREQUENCY RESPONSE ANALYZERS

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Flexible Counter Series in DIN size 24 x 48 mm

Agilent Technologies 3000 Series Oscilloscopes

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

High Power Programmable DC Power Supplies PVS Series

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

DCS Series 1 kw, 1.2 kw, & 3 kw

Optimizing VCO PLL Evaluations & PLL Synthesizer Designs

Portable Time Interval Counter with Picosecond Precision

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

Dash 18X / Dash 18 Data Acquisition Recorder

Recommendations for TDR configuration for channel characterization by S-parameters. Pavel Zivny IEEE GCU Singapore, 2011/03 V1.

Wideband Driver Amplifiers

DS1621 Digital Thermometer and Thermostat

Considerations When Specifying a DC Power Supply

1.44 kw Programmable DC Power Supplies XLN Series

VME IF PHASE MODULATOR UNIT. mod

Embest DSO2300 USB Oscilloscope

Step Response of RC Circuits

MATRIX TECHNICAL NOTES

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

MODEL 1211 CURRENT PREAMPLEFIER

Frequency Response of Filters

DC Electronic Loads 8500 series

Transmitter Interface Program

U1602A Handheld Oscilloscopes, 20 MHz

ε: Voltage output of Signal Generator (also called the Source voltage or Applied

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

KONSTANTER SPL / SPL Programmable Electronic Load

ECONseries Low Cost USB DAQ

INTERFERENCE OF SOUND WAVES

LOW POWER SPREAD SPECTRUM OSCILLATOR


Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

How To Use A Sound Card With A Subsonic Sound Card

Clock Recovery in Serial-Data Systems Ransom Stephens, Ph.D.

Clock Jitter Definitions and Measurement Methods

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Tamura Closed Loop Hall Effect Current Sensors

INTERFERENCE OF SOUND WAVES

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

css Custom Silicon Solutions, Inc.

Pulse Width Modulation

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

Timing Errors and Jitter

Lab 3: Introduction to Data Acquisition Cards

PicoScope 6000A/B Series

Transcription:

Counters SR620 Universal time interval and frequency counter SR620 Time Interval/ Counter 25 ps single-shot time resolution.3 GHz frequency range -digit frequency resolution ( s) 0.00 phase resolution Statistical analysis & Allan variance Graphical output to X-Y scopes Hardcopy to printers and plotters GPIB and RS-232 interfaces Optional ovenized timebase The SR620 Time Interval Counter performs virtually all the time and frequency measurements required in a laboratory or ATE environment. The instrument's high single-shot timing resolution, low jitter and outstanding flexibility make it the counter of choice for almost any application. SR620 Measurements The SR620 measures time interval, frequency, pulse-width, rise and fall time, period, phase and events. Time intervals are measured with 25 ps rms resolution, making the SR620 one of the highest resolution counters available. is measured from 0.00 Hz to.3 GHz, and a choice of gates ranging from period to 500 seconds is provided. The SR620 delivers up to digits of frequency resolution in one second, making it suitable for measurement applications ranging from short-term phase locked loop jitter, to the long-term drift of atomic clocks. All measurement modes are supported by a wide variety of flexible arming and triggering options. Histograms and Strip Charts Unlike conventional counters that only have numeric displays, the SR620 provides live, graphical displays of measurement results. Graphical output of measurement data is available in three formats: a histogram showing the distribution of values within a set of measurements, a strip chart of mean values from successive measurements, or a strip chart of jitter (standard deviation or Allan variance) values from successive

SR620 Time Interval/ Counter may be read via the interfaces or displayed directly on the front panel. Two DAC outputs continuously provide voltages proportional to the mean and the jitter of the measurement sample. These 0 to 0 outputs can drive strip chart recorders or can be set to provide fixed or scanned output voltages. Built-In Auto-Calibration A sophisticated, built-in auto-calibration routine nulls insertion delays between start and stop channels and compensates for the differential nonlinearites inherent in analog time-measurement circuitry. The auto-calibration routine takes about two minutes to perform and should be run every 000 hours of operation. 0 MHz Reference Histogram display measurements. Up to 250 strip chart points or histogram bins can be displayed. Both histograms and strip charts can be displayed on any oscilloscope with an X-axis input (see pictures), or can be plotted on an HP-GL compatible plotter or dot-matrix printer. Convenient cursors allow you to read the value of any data point in the histogram or strip chart. Autoscale and zoom features make it simple to display all, or any portion, of the graphs. The choice of timebase affects both the resolution and accuracy of measurements made with the SR620. SRS offers a standard timebase with an aging coefficient of 0 6 /year, or an optional ovenized-oscillator timebase with only 5 0 0 /day aging and about an order of magnitude better short-term stability than the standard timebase. A rear-panel input lets you connect any external 5 MHz or 0 MHz source as a timebase. Complete Statistical Calculations The SR620 can make measurements on a single-shot basis or calculate the statistics of a set of measurements. Sample sizes from one to one million can be selected. The SR620 will automatically calculate the mean, standard deviation or Allan variance, minimum and maximum for each set of measurements. Reference Output A precision, khz, 50 % duty cycle square wave is available at the front-panel REF output. The REF output can be used as a source of start or stop pulses for any of the SR620's measurement modes. For instance, the length of a cable connected between REF and the B input can be precisely determined by measuring the time delay between REF and B. Built-In DMs and Analog Outputs Two rear-panel DM inputs make measurements of DC voltages with 0.3 % accuracy (±20 DC range). These values SR620 rear panel Computer Interfaces Allan variance plot Standard GPIB (IEEE-488.2) and RS-232 interfaces allow remote control of the SR620. All instrument functions and configuration menu settings are accessible via the interfaces. A fast binary dump mode outputs up to 400 measurements per second to a computer. A parallel printer port allows direct printing from the instrument. Standard IEEE-488.2 communications are supported, and plotter outputs are provided in HP-GL format making interfacing simple and easy. For debugging, the last 256 characters transmitted over the interfaces can be viewed on the front panel.

SR620 Specifications Timebase Standard Option 0 0.000 MHz 0.000 MHz Type TCCXO Ovenized CXO Aging 0 6 /yr. 5 0 0 /day Allan variance ( s) 3 0 0 (typ.) < 0 Stability (0 to 50 C) ppm <2 0 9 Settability 0.0 ppm 0.00 ppm External timebase User may supply 5 or 0 MHz timebase ( nominal) Time Interval, Width, Rise and Fall Times 000 to +000 s in +/-TIME mode ns to +000 s in all others modes Trigger rate 0 to 00 MHz LSD 4 ps single sample, ps with avg. Standard timebase (((25 ps typ. [50 ps max.]) 2 + (0.2 ppb Interval) 2 ) / N) /2 rms Option 0 (((25 ps typ. [50 ps max.]) 2 + (0.05 ppb Interval) 2 ) / N) /2 rms, (N = sample size) Error <±(500 ps typ. [ ns max.] + Timebase Error Interval + Trigger Error) Relative error <±(50 ps typ. [00 ps max.] + Timebase Error Interval) Arming modes +TIME (Stop is armed by Start) +TIME EXT (Ext arms Start) +TIME EXT HOFF (Leading EXT edge arms Start, trailing EXT edge arms Stop) ±TIME (Armed by Start/Stop pair), ±TIME CMPL (Armed by Stop/Start pair) ±TIME EXT (Armed by EXT input edge) EXT arming may be internally delayed or scanned with respect to the EXT input in variable steps. The step size may be set in a 2 5 sequence from µs to 0 ms. The maximum delay is 50,000 steps. 6-digit fixed point with ps LSD Sample rate N (800 µs + measured time interval) + calculation time (N=sample size) The calculation time occurs only after N measurements are completed and varies from zero (N=, no graphics, binary) to 5 ms (N=, no graphics) to 0 ms (display mean or standard dev.) to 60 ms (histogram). 0.00 Hz to 300 MHz via comparator inputs. 40 MHz to.3 GHz via internal UHF prescalers. RATIO A/B range: 0 9 to 0 3 Error <±((00 ps typ. [350 ps max.])/gate + Timebase Error) External, period, µs to 500 s in 2 5 sequence. may be externally triggered with no delay. may be delayed relative to an EXT trigger. The delay from trigger is set from to 50,000 gate widths. 6-digit fixed point with LSD = Freq. 4 ps/gate. µhz maximum resolution ( nhz with 000 for frequencies < MHz) Period 0 to 000 s RATIO A/B range: 0 9 to 0 3 Error <±((00 ps typ. [350 ps max.])/gate + Timebase Error) Period Phase Same as frequency 6-digit fixed point, LSD = ps ( fs with 000 for periods < s) Definition Phase = 360 (T b T a ) / Period A 80 to +80 degrees, 0 to 00 MHz (25 ps Freq. 360 + 0.00) Gate 0.0 seconds ( period min.) for period measurement and sample for time interval measurement. Period may also be measured using externally triggered internal gates as in frequency mode. Error <±( ns Freq. 360 + 0.00) Counts 0 2, RATIO A/B range: 0 9 to 0 3 Count rate 0 to 300 MHz Same as frequency 2 digits Inputs Bandwidth Threshold Sensitivity Auto level Slope Coupling Input noise 300 MHz (.2 ns rise time) 5.00 to +5.00 DC (0 m resolution) 5 m + 0.5 % of setting see graph next page Threshold set between peak input excursions. (f >0 Hz, duty cycle >0 6 ) Rising or falling edge ( MΩ + 30 pf) or 50 Ω 50 Ω termination has SWR < 2.5: from 0 to.3 GHz AC or DC (Ext is always DC coupled) 350 µrms (typ.)

SR620 Specifications Prescaler Protection REF Output see graph 00, 50 Ω terminator is released if input exceeds ±5 p.00 khz (accuracy same as timebase) Rise/fall time 2 ns Amplitude TTL: 0 to 4 (2 into 50 Ω) ECL:.8 to 0.8 into 50 Ω DM Inputs Full scale Type Speed D/A Outputs ±.999 or ±9.99 DC Sample & hold with successive approximation converter MΩ 0.3 % of full scale Approximately 5 ms Comparator Sensitivity ( rms)..0 Specification Limit Typical 0 00 000 (MHz) Full scale Default ±0.00 DC 5 m < Ω oltage proportional to mean and deviation 0.3 % of full scale Input sensitivity Graphics Scope s X-axis Y-axis Hardcopy Two rear-panel outputs to drive x-y analog oscilloscope Histograms and strip charts of mean and jitter 5 to +5 for 0 division deflection 4 to +4 for 8 division deflection 250 (H) 200 () pixels Centronics port for dot-matrix printers. RS-232, IEEE-488.2 for HP-GL compatible plotters. Prescaler Sensitivity ( rms)..0 Specification Limit Typical Interfaces RS-232 GPIB Speed 300 to 9.2 kbaud. All instrument functions may be controlled. IEEE-488.2 interface. All instrument functions may be controlled. Approximately 50 ASCII formatted responses per second. 400 binary responses per second..00 0 00 200 300 400 500 600 700 800 900 000 00 200 300 Prescaler sensitivity General Operating 0 C to 50 C Power 70 W, 00/20/220/240 AC, 50/60 Hz Dimensions 4" 3.5" 4" (WHD) Weight lbs. Warranty One year parts and labor on defects in materials and workmanship Ordering Information SR620 Option 0 Time interval/frequency counter (with rack mount kit) 2 ppb OCXO timebase

SR620 Time Interval/ Counter SR620 Measurement Modes Time In its most basic measurement mode, the SR620 measures the time interval between a start and a stop pulse. Either of the SR620's two inputs, or its REF output, may be selected as the source of start and stop pulses. Internal and external gating signals can be used to holdoff the acceptance of either start or stop pulses. The SR620 can make both positive time measurements (in which the stop pulse follows the start pulse) and negative time measurements (in which the stop pulse occurs before the start pulse). The SR620 measures frequency by the reciprocal frequency counting technique. In other words, the instrument measures the time interval for some integer number of input cycles, then computes frequency by dividing the number of cycles by the time interval. Since no fractional cycle measurements are involved (as would be the case if the instrument measured the number of cycles in a fixed time interval), extremely high frequency resolution can be achieved ( digits in s). The diagram below illustrates this method of computing frequency. Both internal and external gates are supported. 2nd pulse after rising edge GATE Pulse Width FREQUENCY/PERIOD N cycles t 2nd pulse after falling edge Freq = N/ t < N < 0 2 Period = t/n 5ns < t < 000s The width of pulses at either input can be measured. Separate start and stop voltages can be selected for pulse width measurements. and accuracy are the same as time measurement mode. WIDTH: +Time Arming Transition Time Rise and fall times of either input may be measured. Start and stop thresholds may be set between ±5 with 0 m resolution. The 300 MHz input bandwidth allows measurements of rise and fall times as small as ns. Period The SR620 can also measure the period of waveforms. Period is measured similarly to frequency, but the reciprocal of frequency is computed and displayed. Phase The phase angle between signals on the A and B inputs can be measured with 0.00 degree resolution. You can measure the phase of signals (at the same frequency) from 0.00 Hz to 00 MHz. The counter actually makes two measurements: a frequency measurement of one channel, and a time measurement of the delay of the second channel with respect to the first. The phase is then computed as shown below. A B GATE Event Counting RISE/FALL TIMES: +Time Arming t r N cycles t PHASE = PHASE t f 360 x t 2 t /N t 2 T W The SR620 will also count transitions (events) at either of its inputs. As with all the other modes, event counting may be gated internally or externally, and both the voltage threshold and slope for a transition are adjustable. Event rates up to 300 MHz can be counted with up to 2 digits of resolution. The unit also has a ratio mode which will compute the ratio of the number of events counted on the A and B inputs.