TCD in Intensive Care



Similar documents
Monitoring of Cerebral Blood Flow. Transcranial Doppler Laser Doppler Flowmetry Thermal dilution method (Hemedex)

perfusion pressure: Definitions. Implication on management protocols. What happens when CPP is too low, and when it is too high? Non-invasive CPP?

Duplex Carotid Sonography in Distinguishing Acute Unilateral Atherothrombotic from Cardioembolic Carotid Artery Occlusion

Subclavian Steal Syndrome By Marta Thorup

Brain Cooling in Traumatic Brain Injury and Stroke

ICMB: software for on-line analysis of bedside monitoring data after severe head trauma

Ultrasound in Vascular Surgery. Torbjørn Dahl

Pressure reactivity: Relationship between ICP and arterial blood pressure (ABP). Pressure-reactivity index, computational methods. Clinical examples.

Helen Fry Manager, Publications and Education Resources Joint Commission Resources

Renovascular Hypertension

What You Should Know About Cerebral Aneurysms

Your Guide to Express Critical Illness Insurance Definitions

XVII Neurosonology Research Group of the World Federation of Neurology General Assembly

AI CPT Codes. x x MRI Magnetic resonance (eg, proton) imaging, temporomandibular joint(s)

Duplication Images in Vascular Sonography

Summary Diagnosis and Treatment of Chronic Cerebrospinal Venous Insufficiency (CCSVI) in People with Multiple Sclerosis (MS)

Overall Goals/Objectives - Surgical Critical Care Residency Program The goal of the Pediatric Surgical Critical Care Residency program is to provide

Applications of Doppler Ultrasound in Fetal Growth Assessment. David Cole

How To Comply With The American Medical Association'S Lcd

it s all Choices about S H R P School of Health Related Professions Vascular Technology

Vascular Laboratory Education and Training

Vascular Technology (VT) Content Outline Anatomy & physiology 20% Cerebrovascular Cerebrovascular normal anatomy Evaluate the cerebrovascular vessels

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

What Is an Arteriovenous Malformation (AVM)?

Accreditation and Certification Guidelines

20. Cerebral Compartmental Compliances

The importance of the initial assessment in trauma patients /in a prehospital setting: Therapeutic decisions Patient outcomes

Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality

CPT CODE PROCEDURE DESCRIPTION. CT Scans CT HEAD/BRAIN W/O CONTRAST CT HEAD/BRAIN W/ CONTRAST CT HEAD/BRAIN W/O & W/ CONTRAST

Vascular Laboratory Fundamentals. Robert Mitchell MD, RPVI Duke University Medical Center 5/2/08

huidige en toekomstige hemodynamische bewaking

Clinical Research Software for Intensive Care Monitoring

Vascular and heart surgery

Lifecheque Basic Critical Illness Insurance

Advanced Disease-Specific Care Certification Requirements for Comprehensive Stroke Center (CSC)

Effects of Hypertension and Antihypertensive Treatment on Retrobulbar Circulation Detected on Doppler Sonography

American Society of Echocardiography 2014 Coding and Reimbursement Newsletter

Advanced Heart Failure & Transplantation Fellowship Program

Compactly Powerful. Ultrasound System UGEO PT60A CT-UGEO PT60A-CWW-CMI-0705-EN

Advances in Stroke Care

Specific Basic Standards for Osteopathic Fellowship Training in Cardiology

Doppler Ultrasound in the Management of Fetal Growth Restriction Chukwuma I. Onyeije, M.D. Atlanta Perinatal Associates

Preparation iagnostic Medical Sonographer Overview"

PRELIMINARY PROGRAM AT-A-GLANCE

Extracranial Cerebrovascular Duplex Ultrasound Evaluation

The Ratio of Flow Velocities in the Middle Cerebral and Internal Carotid Arteries for the Prediction of Cerebral Palsy in Term Neonates

THE INTERNET STROKE CENTER PRESENTATIONS AND DISCUSSIONS ON STROKE MANAGEMENT

Clinical Medical Policy Cognitive Rehabilitation

SERVICE: Neurosurgery - Sinai, PGY 1

Red Blood Cell Transfusions for Sickle Cell Disease

PHYSICIAN ASSISTANT STUDIES UTMB ESSENTIAL FUNCTIONS AND TECHNICAL STANDARDS Updated 04/10/13

SUTTER MEDICAL CENTER, SACRAMENTO Department of Cardiovascular Disease Cardiology - Delineation of Privileges

Resuscitation in congenital heart disease. Peter C. Laussen MBBS FCICM Department Critical Care Medicine Hospital for Sick Children Toronto

GP workshop. Maria Fitzpatrick Nurse Consultant Kings College Stroke Centre

Cerebral blood flow (CBF) is dependent on a number of factors that can broadly be divided into:

How To Use An Ultrasound For Medical Research

ASSESSMENT REPORT. Program: AAS Diagnostic Medical Sonography Cardiac Vascular Tract

Neurodiagnostic Equipment Solutions

Using the Pupillometer in Clinical Practice

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

School of Diagnostic Medical Sonography

First floor, Main Hospital North Services provided 24/7 365 days per year

Monitoring the Brain and Spinal Cord. Tod B. Sloan, MD, PhD, MBA

Why bother? Physician Certification Sonographer Certification Billing and Coding

1. Cerebrospainal Fluid (CSF) circulation in brain: Sites and mechanisms of CSF secretion, circulation and reabsorption. Physiological and modelling

A t h e n s I n s t i t u t e o f U l t r a s o u n d S u n s e t D r i v e A t h e n s G A

Special Report. Recommendations for Comprehensive Stroke Centers A Consensus Statement From the Brain Attack Coalition

Term Critical Illness Insurance

P.A. STUDENT COMPETENCIES, TECHNICAL STANDARDS & JOB DESCRIPTION

A. Sue Carlisle, PhD, MD Professor of Anesthesia and Medicine Associate Dean for UCSF at SFGH

Clinical Medical Policy Cognitive Rehabilitation

How To Learn To Perform An Ultrasound

It s not something you want to think about, but it s something you want to prepare for.

Translating Science to Health Care: the Use of Predictive Models in Decision Making

Neurocritical Care Program Requirements


Knowledge Synergies The New Paradigm of Innovation. Israel Makov

Types of Brain Injury

3D Ultrasound. Outline. What is 3D US? Volume Sonography. 3D Ultrasound in Obstetrics: Current Modalities & Future Potential. Alfred Abuhamad, M.D.

Computed Tomography, Head Or Brain; Without Contrast Material, Followed By Contrast Material(S) And Further Sections

Delineation of Privileges Department of Surgery/Section of Vascular Surgery. Name: Please print or type

Ultrasound - Vascular

Ischemia and Infarction

The ultrasound system that sets new standards

Report of the Welsh Neuroscience External Expert Review Group. Recommendations for Mid and South Wales

Measure #195 (NQF 0507): Radiology: Stenosis Measurement in Carotid Imaging Reports National Quality Strategy Domain: Effective Clinical Care

Coding and Payment Guide for the Physical Therapist. An essential coding, billing, and reimbursement resource for the physical therapist

APPENDIX 1: INTERDISCIPLINARY APPROACH TO PREVENTION AND MANAGEMENT OF DIABETIC FOOT COMPLICATIONS

Emergency Ultrasound. Emergency Room. EMERGENCY ULTRASOUND reimagined

Statistical Analysis of Arterial Blood Pressure (ABP), Central Venous. Pressure (CVP), and Intracranial Pressure (ICP)

Discovery of an Aneurysm Following a Motorcycle Accident. Maya Babu, MSIII Gillian Lieberman, M.D.

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

A Patient s Guide to Antithrombotic Therapy in Atrial Fibrillation

The ASA defines anesthesiology as the practice of medicine dealing with but not limited to:

Imaging of Acute Stroke. Noam Eshkar, M.D New Jersey Neuroscience Institute JFK Medical Center Edison Radiology Group

Levels of Critical Care for Adult Patients

NAME OF THE HOSPITAL: 1. Coronary Balloon Angioplasty: M7F1.1/ Angioplasty with Stent(PTCA with Stent): M7F1.3

An abdominal ultrasound produces a picture of the organs and other structures in the upper abdomen.

Level III Stroke Center Data Collection Requirements

Building an Emergency Response to Acute Stroke

Transcription:

TCD in Intensive Care Background: Transcranial Doppler (TCD) ultrasonography is a technique that uses a hand-held Doppler transducer (placed on the surface of the cranial skin) to measure the velocity and pulsatility of blood flow within the intracranial and the extracranial arteries. Introduced by Rune Aaslid in 1982, it has become indispensable in clinical practice. The main obstacle to ultrasound penetration of the skull is bone. Low frequencies, 1-2 MHz, reduce the attenuation of the ultrasound wave caused by bone. Transcranial Doppler also provides the advantage of acoustic windows representing specific points of the skull where the bone is thin enough to allow ultrasounds to penetrate. It has its main application in the diagnosis and monitoring of vasospasm in patients with subarachnoid hemorrhage. Literature: Applications of ultrasound in the intensive care unit Author (Harding u. a., 2011) Comment German Article Quantification Article about ultrasound at ICU in general Monitoring of brain function in anesthesia and intensive care. Author (Grocott u. a., 2010) Quantification Using a comprehensive cerebral monitoring strategy may optimize outcomes in anesthetic and intensive care. Atlas of Doppler Sonography by DWL [1] Rev0 _05/2013

Author (Geeraerts u. a., 2008) The pulsativity index (PI; normal values for the middle cerebral artery=1.0+/-0.2) and end diastolic velocity (EDV; normal values for the middle cerebral artery=40+/-10 cm/s) give important information to evaluate the resistance status of small downstream arteries. A high PI (>1.4) with a low EDV (<20 cm/s) indicates a low blood flow with a high ischemic risk due to low cerebral perfusion pressure. TCD can also detect cerebral vasospasm after subarachnoid hemorrhage, but sensitivity and specificity for vasospasm diagnosis are low compared to angiography. However, a day-to-day increase in arterial blood cell velocities can help determine the vasospasm risk and/or indicate that angiography should be done., Article in French Quantification TCD applications at neurosurgical ICUs are mentioned Transcranial Doppler monitoring in subarachnoid hemorrhage: a critical tool in critical care. Author (Rigamonti u. a., 2008) Currently, the gold standard for vasospasm diagnosis is cerebral angiography. Transcranial Doppler ultrasonography is a relatively new, non-invasive tool, allowing for bedside monitoring to determine flow velocities indicative of changes in vascular calibre. Transcranial Doppler ultrasonography can be useful pre-, intra- and post-operatively, while helping to recognize the development of cerebral vasospasm before the onset of its clinical effects. 1980 to August 2007 Quantification Transcranial Doppler ultrasonography assists in the clinical decisionmaking regarding further diagnostic evaluation and therapeutic interventions. When performed in isolation, the contribution of TCD to improving patient outcome has not been established. Nevertheless, TCD has become a regularly employed tool in neurocritical care and perioperative settings. Atlas of Doppler Sonography by DWL [2] Rev0 _05/2013

Transcranial Doppler ultrasonography in intensive care. Author (Rasulo u. a., 2008) Quantification A very good summary. One of the most often cited articles related to TCD. Author (Alvarez-Fernández und Pérez-Quintero, 2007) Additional applications to them, mentioned in White et al., 2006. Emboli detection, RLS detection, CCA diagnosis Comment Letter to the editor Quantification Very nice addition Role of transcranial Doppler in neurocritical care. Author (Saqqur u. a., 2007) Transcranial Doppler has several practical applications in neurocritical care. It has its main application in the diagnosis and monitoring of vasospasm in patients with subarachnoid hemorrhage. In addition, it holds promise for the detection of critical elevations of intracranial pressure. Its ability to measure CO2 reactivity and autoregulation may ultimately allow intensivists to optimize cerebral perfusion pressure and ventilatory therapy for the individual patient. Transcranial Doppler findings of brain death are well described and can be useful as a screening tool. Quantification Summary Atlas of Doppler Sonography by DWL [3] Rev0 _05/2013

Applications of transcranial Doppler in the ICU: a review. Author (White und Venkatesh, 2006) Technological advances such as M mode, colour Doppler and threedimensional power Doppler ultrasonography have extended the scope of TCD to include other non-critical care applications including assessment of cerebral emboli, functional TCD and the management of sickle cell disease. Quantification Despite publications suggesting concordance between TCD velocity measurements and cerebral blood flow there are few randomized controlled studies demonstrating an improved outcome with the use of TCD monitoring in neurocritical care. Newer developments in this technology include venous Doppler, functional Doppler and use of ultrasound contrast agents. Summary: Here are some reviews of literature listed, which concern TCD in intensive care medicine and summarize potential applications of TCD. For further research information on special ICU applications as brain injury or cardiac arrest, read in these chapters. Experts: none Atlas of Doppler Sonography by DWL [4] Rev0 _05/2013

Literature Alvarez-Fernández JA, Pérez-Quintero R. Some more applications of transcranial Doppler in the ICU. Intensive Care Med 2007; 33: 1667-1668.[zitiert 2011 Nov 14] Geeraerts T, Ract C, Duranteau J, Vigué B. [Transcranial doppler in neurosurgery]. Neurochirurgie 2008; 54: 731-738.[zitiert 2011 Nov 2] Grocott HP, Davie S, Fedorow C. Monitoring of brain function in anesthesia and intensive care. Curr Opin Anaesthesiol 2010; 23: 759-764.[zitiert 2011 Dez 10] Harding U, Goeters C, Schmidt C. [Applications of ultrasound in the intensive care unit]. Anasthesiol Intensivmed Notfallmed Schmerzther 2011; 46: 190-200; quiz 201.[zitiert 2011 Okt 31] Rasulo FA, De Peri E, Lavinio A. Transcranial Doppler ultrasonography in intensive care. Eur J Anaesthesiol Suppl 2008; 42: 167-173.[zitiert 2011 Okt 29] Rigamonti A, Ackery A, Baker AJ. Transcranial Doppler monitoring in subarachnoid hemorrhage: a critical tool in critical care. Can J Anaesth 2008; 55: 112-123.[zitiert 2011 Nov 2] Saqqur M, Zygun D, Demchuk A. Role of transcranial Doppler in neurocritical care. Crit. Care Med. 2007; 35: S216-223.[zitiert 2011 Dez 20] White H, Venkatesh B. Applications of transcranial Doppler in the ICU: a review. Intensive Care Med 2006; 32: 981-994.[zitiert 2011 Nov 14] Atlas of Doppler Sonography by DWL [5] Rev0 _05/2013