MegaRAID SAS User Guide for Linux



Similar documents
Management Tools. Contents. Overview. MegaRAID Storage Manager. Supported Operating Systems MegaRAID CLI. Key Features

MSM Software Feature Difference Between the MR Controller and the IR Controller

Intel RAID Web Console 2 and StorCLI Command Line Tool

This chapter explains how to update device drivers and apply hotfix.

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

LSI MegaRAID User s Manual

Configuring ThinkServer RAID 500 and RAID 700 Adapters. Lenovo ThinkServer

USER S GUIDE. MegaRAID SAS Software. April , Rev. D

Dell SAS RAID Storage Manager. User s Guide. support.dell.com

PCI Express SATA / esata 6Gb/s RAID Card User Manual

WebBIOS Configuration Utility Guide

How To Add Drives To A Dip N Recording Appliance

Dell DR4000 Disk Backup System. Introduction to the Dell DR4000 Restore Manager A primer for creating and using a Restore Manager USB flash drive

Installing and Configuring SAS Hardware RAID on HP Workstations

MegaRAID SAS Device Driver Installation

MegaRAID SAS Device Driver Installation

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

Intel RAID Controller Command Line Tool 2 User Guide. Order Number: E

Marvell SATA3 RAID Installation Guide

User Manual for SAS RAID 2108

RAID EzAssist Configuration Utility Quick Configuration Guide

12Gb/s MegaRAID SAS Software

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Xserve G5 Using the Hardware RAID PCI Card Instructions for using the software provided with the Hardware RAID PCI Card

NEC Express5800 Series MegaRAID Storage Manager User's Guide - Windows Edition -

RAIDXPERT USER MANUAL. Version 2.1

EX Port SATA3 RAID/HyperDuo PCIe(x2) Card

USER S GUIDE. MegaRAID SAS Software. June 2007 Version , Rev. B

AMD SP5100 Dot Hill SATA RAID Users Manual V100

Contents. Overview. Drive Policy RAID 500 features. Disable BGI RAID 700 features. Management Tasks Choosing the RAID Level.

Configuring ThinkServer RAID 100 on the TS140 and TS440

HP StorageWorks Modular Smart Array 1000 Small Business SAN Kit Hardware and Software Demonstration

AMD RAID Installation Guide

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

SATA II 4 Port PCI RAID Card RC217 User Manual

AMD RAID Installation Guide

PCIe SATA 6G Raid Card

Performance Report Modular RAID for PRIMERGY

USB3.0/eSATA/1394b-to-SATA II RAID SUBSYSTEM

Mini-EPic System of RAID

AMD RAID Installation Guide

MegaRAID RAID Controller Configuration Software Guide

Reboot the ExtraHop System and Test Hardware with the Rescue USB Flash Drive

Managing RAID. RAID Options

Embedded MegaRAID Software

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

ION-NAS Network Storage Solutions

NVIDIA RAID Installation Guide

User Guide - English. Embedded MegaRAID Software

Installing the Operating System or Hypervisor

RAID installation guide for ITE8212F

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

README.TXT

USER S GUIDE. MegaRAID Configuration Software. February 2003 Version 1.0 DB

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Cautions When Using BitLocker Drive Encryption on PRIMERGY

Education. Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller. Study guide. XW5078 Release 1.00

COMMAND LINE UTILITY USER S GUIDE

Guide to SATA Hard Disks Installation and RAID Configuration

DF to-2 SATA II RAID Box

DELL. Unified Server Configurator: IT and Systems Management Overview. A Dell Technical White Paper

SATA1.5G/ATA133 RAID Controller Card RC215 User Manual

Configuring ThinkServer RAID 100 on the Lenovo TS130

MegaRAID Configuration Software

Mini-EPICa SATA II-to-SATA II RAID SUBSYSTEM

Intel Rapid Storage Technology

PIKE LSISAS RAID card. User Guide

esata 6G RAID PCIe 2.0 Controller Card

HP Embedded SATA RAID Controller

HP Array Configuration Utility User Guide

SATA RAID Controller Command Line Interface

readme.txt README.TXT

Serial ATA RAID PCI. User's Manual

DESLock+ Basic Setup Guide Version 1.20, rev: June 9th 2014

Installation and Configuration Guide for Cluster Services running on Microsoft Windows 2000 Advanced Server using Acer Altos Servers

Serial ATA 4-Channel RAID Quick Installation Guide

Intel RAID Basic Troubleshooting Guide

4.4 Managing Software Licensing

Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide

Comparing Dynamic Disk Pools (DDP) with RAID-6 using IOR

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

RAID SYSTEMS SOFTWARE USER MANUAL.

ASM_readme_6_10_18451.txt README.TXT

Getting Started With RAID

Using RAID Admin and Disk Utility

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

SyAM Software, Inc. Server Monitor Desktop Monitor Notebook Monitor V3.2 Local System Management Software User Manual

PROMISE ARRAY MANAGEMENT (PAM) for

Configuration Guide. Remote Backups How-To Guide. Overview

LSI Software RAID Configuration Utility

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Embedded MegaRAID Software

Cisco C-Series Servers Troubleshooting Guide

MegaRaid SAS Software

Installation Instruction STATISTICA Enterprise Small Business

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

NSS Volume Data Recovery

Transcription:

Table of Contents RAID Configuration... 1 Storage Manager Installation... 11 Running MegaRAID Storage Manager (MSM)... 11 Running MegaCLI... 11 Special Notes... 15 Technical Support... 15 This guide is intended as a quick reference to using some of the more useful features of the MegaRAID software. For a complete reference, please see the official MegaRAID documentation. A copy can be found as Doc/mr_sas_sw_ug.pdf on the ASL Driver CD. RAID Configuration Initial RAID configuration is performed via the LSI WebBIOS utility. The following example demonstrates creation of a three disk RAID-5 array with a single hot spare. 1. When the LSI BIOS screen appears, press Ctrl-H to enter the WebBIOS configuration utility. 2. Click Start on the Adapter Selection screen. 3. Select Configuration Wizard. 1

4. Choose New Configuration then click on Next. 5. Click on Yes to confirm. 6. Choose Custom Configuration then click on Next. 2

7. Highlight the data drives then click on AddToArray. 8. Click on Accept DG. 3

9. Click on Next. 10.Click on Add To SPAN. 4

11.Click on Next. 12.Change the RAID Level to RAID 5. The right side of the screen lists the maximum size for the available RAID levels. Edit the Select Size field to match the R5 value. 5

13.Click on Accept. 14.Click on Next. 6

15.Click on Accept. 16.Click on Yes to Confirm. 17.Click on Yes to initialize the array. 7

18.Click on Home. 19.Select Physical Drives. 8

20.Highlight an available drive. Choose Properties and click on Go. 21.Choose Make Global HSP then click on Go. 22.Click on Home. 9

23.Click on Exit. 24.Click on Yes to confirm. 25.Reboot the system. 10

Storage Manager Installation The MegaRAID Storage Manager includes both GUI (MSM) and text based tools (MegaCLI) to monitor and manage the disk array. The following controllers have been tested: LSI MegaRAID SAS 8704EM2 Since these applications are not included in standard Linux distributions, they must be installed manually after reinstalling the operating system. For convenience, ASL has included the RPM packages for these tools on the ASL Driver CD. To install the MegaRAID Storage Manager, insert the ASL Driver CD into the optical drive and run the following commands: # yum install compat-libstdc++-33 # yum install net-snmp-utils # yum install libxi.i386 # mount /dev/cdrom /media # rpm -ivh /media/asl-packages/sas*.rpm # rpm -ivh /media/asl-packages/mega*.rpm # umount /media Running MegaRAID Storage Manager (MSM) MSM is a GUI Java application.to launch MSM, execute the following command: $ /usr/local/megaraid\ Storage\ Manager/startupui.sh The username is root and the password is the root password for the system. After logging in enter the IP address of the system you wish to manage and click on the Update button. Select the server from the resulting list and click on the Connect button. To access detailed documentation select Help from the MSM menu. Running MegaCLI To run the MegaRAID CLI, execute the following command: 32-bit /opt/megaraid/megacli/megacli 64-bit 11

/opt/megaraid/megacli/megacli64 Example Usage Display logical devices /opt/megaraid/megacli/megacli64 -LDInfo -LALL -aall Adapter 0 -- Virtual Drive Information: Virtual Disk: 0 (Target Id: 0) Name: RAID Level: Primary-5, Secondary-0, RAID Level Qualifier-3 Size:556.929 GB State: Optimal Stripe Size: 64 KB Number Of Drives:3 Span Depth:1 Default Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU Access Policy: Read/Write Disk Cache Policy: Disk's Default Encryption Type: None Display Physical Devices /opt/megaraid/megacli/megacli64 -PDList -aall Adapter #0 Enclosure Device ID: 252 Slot Number: 0 Device Id: 4 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Online SAS Address(0): 0x5000c50008f05a69 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: SEAGATE ST3300655SS 00023LM3GNM9 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Foreign State: None 12

Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device MegaRAID SAS Enclosure Device ID: 252 Slot Number: 1 Device Id: 6 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Online SAS Address(0): 0x5000c50008f05e65 SAS Address(1): 0x0 Connected Port Number: 1(path0) Inquiry Data: SEAGATE ST3300655SS 00023LM3GMDK FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Enclosure Device ID: 252 Slot Number: 2 Device Id: 5 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Online SAS Address(0): 0x5000c50008f05775 SAS Address(1): 0x0 Connected Port Number: 2(path0) Inquiry Data: SEAGATE ST3300655SS 00023LM3GNF3 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s 13

Media Type: Hard Disk Device MegaRAID SAS Enclosure Device ID: 252 Slot Number: 3 Device Id: 7 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS Raw Size: 279.396 GB [0x22ecb25c Sectors] Non Coerced Size: 278.896 GB [0x22dcb25c Sectors] Coerced Size: 278.464 GB [0x22cee000 Sectors] Firmware state: Hotspare SAS Address(0): 0x5000c50008f05669 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST3300655SS 00023LM3GNCL FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Foreign State: None Device Speed: 3.0Gb/s Link Speed: 3.0Gb/s Media Type: Hard Disk Device Hotspare Information: Type: Global, is revertible Disable Alarm /opt/megaraid/megacli/megacli64 -AdpSetProp AlarmDsbl -aall Adapter 0: Set alarm to Disabled success. Enable Alarm /opt/megaraid/megacli/megacli64 -AdpSetProp AlarmEnbl -aall Adapter 0: Set alarm to Enabled success. Show Rebuild Progress /opt/megaraid/megacli/megacli64 -PDRbld -ShowProg -physdrv[252:3] -aall Rebuild Progress on Device at Enclosure 252, Slot 3 Completed 55% in 22 Minutes. Display Rebuild Progress continuously. 14

Display detailed Adapter and Device information /opt/megaraid/megacli/megacli64 -AdpAlILog -aall Special Notes The drive identification feature does not work. When a drive fails, the controller will automatically start rebuilding the array onto an available hot spare. When the bad drive is replaced, the controller will perform a copyback operation. This involves copying the data from the hot spare back to the newly installed drive. After the copyback is complete, the hot spare will function as a hot spare again. All controller status messages are logged to /var/log/messages. Technical Support Prior to contacting technical support, please visit the ASL online FAQ for quick answers to common hardware and software issues.the answers may be searched by keyword or browsed by category. These documents are maintained with up to date information. FAQ [http://faq.aslab.com] To request replacement of a defective part (except monitor) on systems under warranty, please send an E- mail to <techsupport@aslab.com> with the following information: Serial number or invoice number of the system Detailed description of the problem Shipping address 15

If the transaction involves multiple systems, ASL highly recommends creating one ticket per system. This will avoid any mixup when the RMA is processed. Defective monitors will be handled directly by the manufacturer. Here is the contact information: Viewsonic: 800 888 8583 (US) or 866-262-1967 (Canada) IIyama: 800 594 7480 16