Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

Unidirectional Transmitter/ Receiver Units Introduction

Temperature & Humidity SMS Alert Controller

Rack mounted telephone- and leased line modem for industrial applications

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Contents. Document information

3500/93 System Display

Telephone- and leased line modem for industrial applications TD-36

NEW. EVEN MORE data acquisition and test stand automation

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

3500/62 Process Variable Monitor

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

PCS0100en Persy Control Services B.V. Netherlands

Waveguide Access Point WGA631. Product Guide

NC-12 Modbus Application

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Product Specifications

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

Modular I/O System Analog and Digital Interface Modules

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Panel Meters and Controllers Modular Panel Meter Type EDM 35

WEATHER STATION FOR SOLAR FARM MONITORING

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Current Monitoring Kit QUICK START GUIDE

Model: DC-A2IO Advanced HVAC Controller

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

3500/22M Transient Data Interface

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

FM Radio Transmitter & Receiver Modules

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

connecdim Gateway G1 Ethernet TCP/IP to DALI

J TB/TW Temperature limiter, temperature monitor

Vario-Series Accessories

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Microcor Wireless Transmitter (MWT)

Climate Ready Control Systems Technical Specifications

Rosemount 333 HART Tri-Loop

Power Supplies 3. SDN-P DIN Rail Series

NETWORK ENABLED EQUIPMENT MONITOR

SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

GSM Voice Auto Dialer & SMS Sender JC-999

4-Channel Thermometer / Datalogger

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Current Monitoring Kit

Long Distance Industrial Wireless Transmitters and Receivers

AP60. 9 Wireless. Wireless-b/g/n Long Range PoE Access Point. Wireless-b/g/n Long Range Radio. Passive PoE and 4-LAN Ports. IP Finder Management 4 LAN

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Quick Connect. quick - simple - efficient.

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

iva Cable & Antenna Analyzer

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

1701/22 FieldMonitor Management Interface Module

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

T200, PTP/IEEE 1588 Grandmaster Clock and

Temperature Transmitters ZTT series

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

USB-500/600 Series Low-Cost Data Loggers and Accessories

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

TX2123 RS485 TO ETHERNET ADAPTOR

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Application/Connection Examples

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

ST Series POWER SUPPLIES USER INSTRUCTIONS

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Wahl C50 Calibrator FEATURES

200 Range Dialer Installation Manual. Version 1.0

1 Serial RS232 to Ethernet Adapter Installation Guide

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

Nardalert S3 Non-Ionizing Radiation Monitor

iva Cable & Antenna Analyzer

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Byonics Micro Trak 1000 High Altitude Balloon Tracker

SMS GSM Alarm Messenger

TX OPEN RS232/485 module

Digital input modules

Rosemount 333 HART Tri-Loop

Solar Powered Wireless Sensors & Instrumentation: Energy Harvesting Technology Reduces Operating Cost at Remote Sites

Indoor / Outdoor Antenna

Transcription:

ZigBee WIRELESS SYSTEMS AND SENSORS Supports ZigBee Wireless Protocol Use of unlicensed 2.4 GHz Radio Band Ultra-low Power Consumption Easy to add and remove sensor nodes High Security 128 bit encryption plus Access Control lists available Flexible network Topology Up to 250 kbps Data Rate Low Cost and no Cabling! Introduction The range of Wireless Sensors and Systems designed and manufactured by Industrial Interface is based primarily around the ZigBee protocol working on the world-wide IEEE 802.15.4 wireless hardware standard. The benefits of using the ZigBee protocol are highlighted in the bullet points above. Of course the main benefit of wireless technology is the flexibility and cost savings obtained through not having to lay cables between sensors and control systems. It also allows for easy add-ons to existing wired systems. These features, together with the wide range of sensors I/O modules and the Z-Port Ethernet Gateway enable complete data acquisition and control systems to be realised. In addition using our Web server system allows these networks to be monitored from anywhere in the world using any standard internet browser. Some typical uses are outlined below and in the following pages. Example One: Simple Cable replacement system. Transmitter accepts any standard process input and transmits value to receiver unit Receiver gets values from transmitter and outputs value in analogue 4-20mA, 0-10V or similar format.

Example Two: Typical ZigBee Sensor Network. Industrial Interface The Signal Conditioning People Ethernet TCP/IP or RS232/485 Communications or Web server Multiple battery powered sensors transmit data at programmable intervals to a Z-PORT Network Coordinator which can transfer the data onto an Ethernet or RS232/485 network, Data from up to 256 nodes can be stored on one Z-PORT module and up to 16 networks can co-exist together. Several different topologies are possible including Mesh self-healing wireless networks Example Three: Wireless Trip Ampifier A ZigBee wireless transmitter sends an OK message every 10 minutes unless an alarm condition is met. On reaching an alarm state the transmitter immediately sends an alarm message to the Z-200 receiver which can switch up to two relay outputs.

ZIGBEE WIRELESS CONTENTS Data Sheets Wireless Systems & Sensors Z-200 ZigBee System 5 Powered transmitter/receiver unit Cable Replacement option Multiple inputs, expandable using ISO-SLICE I/O Z-PORT ZigBee Gateway 7 ZigBee Network Coordinator with Ethernet or RS232 Gateway Z-HEAD ZigBee 9 Universal in-head transmitter ISO-SLICE 11 Isolated bus input/output System Universal input types Galvanic Isolation Z-TEMP 13 ZigBee Temperature and Relative Humidity Transmitter Z-ROOT 15 ZigBee Network Router ZigBee Antennae 17 A range of ZigBee Antennae including ATEX certified items

Z-200 ZIGBEE TRANSMITTER / RECEIVER SYSTEM Transmits up to 1024 I/O Values through ZigBee Wireless Link Simple Cable Replacement System Local indication of Input Values Expand the number of Inputs through Iso-Slice I/O Modules Receiver Output either analogue or Ethernet/RS232 Connection with Local Display Description Inputs The Z-200 unit allows almost any number of analogue or digital input values to be wirelessly transmitted to a remote receiver with either analogue 4-20mA, 0-10V, Ethernet or RS232 outputs. The transmitter unit has one universal analogue input but the system can be expanded through the use of the optional slice I/O modules. These modules connect automatically via the DIN rail mounted bus connector allowing the easy addition and removal of extra I/O. The built-in display allows local monitoring of the individual inputs and outputs, a useful commissioning and operations tool. The Z-200 has typically two uses: 1) To transmit a single variable to a receiver unit which outputs a 4-20mA or 0-10V signal corresponding to the input 2) To transmit multiple input values to a receiver unit which provides either multiple 4-20mA or 0-10V outputs or a single Ethernet or RS232 connection. The transmitter and receiver units are identical units factory configured for either function. Outputs DC Current and Voltage 0-20mA, 4-20mA, 0-10mA into 750Ω 0-1 V, 0-10 V, 1-5V into a minimum 2kΩ The input types and ranges included below are our standard ones only. Contact Sales for others. DC Current & Voltage 0-20mA, 4-20mA, 0-10mA into 15/30 Ω 0-1V, 0-10V, 1-5V into 100kΩ / 1MΩ 0-25mV, 0-100mV, 0-500mV into >10MΩ Min & Max Full Scale Ranges are: DC Current 0-1mA 0-5A Bipolar DC Current ±5mA ±10mA DC Voltage 0-25mV 0-300V* Bipolar DC Voltage ±5V ±10V 2 Wire Pot 0-125Ω 0-1kΩ 3 Wire Pot 0-1kΩ 0-100kΩ * Note: For input voltages greater than 60Vdc a Divider unit must be specified. Thermocouples Types E,J,K,N,R,S,T,B linearised or non-linearised Ranges: Wide range of inputs Cold junction compensation (can be turned off) Upscale or downscale t/c burnout options Resistance Thermometers 2, 3 or 4 wire PT100 or PT1000, linearised or non-linearised Ranges: Wide range of inputs Upscale or downscale RTD burnout options Frequency Input Wide range of freq inputs to 250kHz. Specify -FREQ Additional I/O Extra analogue and digital inputs and outputs are available through the ISO-SLICE slice I/O modules.

Parameter Min Typ Max Comments Supply Voltage 16 24V 30 Supply Current (ma) 65 120 24 V dc supply Input Impedance (Volt) 1MΩ Input Impedance( ma) 15Ω Volt drop (ma input) 0.3 At 20mA input Output Linearity Error ±0.01% ±0.05% Temp Coefficient ±100ppm/ºC Operating Ambient 0ºC 55ºC Relative Humidity 0% 90% see note 1 Isolation Voltage 1kV Surge Voltage 2.5kV for 50µS Transient of 10kV/µS Notes The process input level is shown on the 4 digit LED display. Figures based on 24 Vdc supply 20 degc ambient. Installation Data Mounting Orientation Connections Conductor size Insulation Stripping Weight DIN Rail TS35 Any Screw Clamp with pressure plate 0.5-4.0mm 12mm Approx 120g Connection Details Ordering Information Please supply: 3. Tx supply +ve RTD 4 th wire 5. Input ma +ve T/C +ve RTD +ve 4. Input ma -Ve T/C -ve RTD -ve 6. RTD 3 rd wire Part Number: Z-200 Input Type: e.g ma, Volt, T/C, RTD Input Range: e.g 4-20, 0-10, 0-500ºC 1. Power Supply -ve 2. Power Suplpy +ve 10. Output -ve 12. Output +ve Power Supply: Options: 24 Vdc Extra I/O available through ISO-SLICE modules

Z-PORT ZIGBEE TO ETHERNET or RS232 GATEWAY 2.4GHz ZigBee to Ethernet Gateway Enables easy add-on of wireless networks to existing Ethernet systems Allows a single remote sensor to be incorporated into an Ethernet network without the need for expensive cabling RS232/485 version also available Description The Z-PORT Ethernet Gateway provides a link between ZigBee based wireless sensors and sensor networks and Industrial Ethernet or RS232 networks. This allows ZigBee based wireless networks or individual sensors to be incorporated into new or existing Industrial Ethernet data monitoring and control networks. The Z-PORT has been carefully designed to support a range of network systems including sophisticated self-forming and self-healing mesh networks, to ensure that data gets to its destination. The Z-PORT can interface with standard10/100baset Ethernet networks giving access to the standard MODBUS TCP protocol, ensuring compatibility with most industrial automation systems. Multiple battery powered sensors transmit data at programmable intervals to a Z-PORT Network Coordinator which can transfer the data onto an Ethernet or RS232/485 network, Data from up to 256 nodes can be stored on one Z-PORT module and up to 16 networks can co-exist together. Several different topologies are possible including Mesh self-healing wireless networks Ethernet TCP/IP or RS232/485 Communications or Web server

Parameter Min Typ Max Comments Supply Voltage 16 24V 30 Supply Current (ma) 100 120 24 V dc supply Ethernet Interface 10Base-T or 100Base-T Connector RJ45 Protocols TCP/IP UDP/IP others available RS232 Data Rate 2400 300 to 115,200 baud Data bits 7 or 8 Parity Odd / even / none Isolation voltage 1kV Operating Ambient 0ºC 55ºC Relative Humidity 0% 90% Surge Voltage 2.5kV for 50µS Transient of 10kV/µS Notes Local LED display can display sensor values in real engineering units and Z-PORT setup information Installation Data Mounting Orientation Connections Conductor size Insulation Stripping Weight DIN Rail TS35 Any Screw Clamp with pressure plate 0.5-4.0mm 12mm Approx 120g Connection Details 1. Power Supply -ve 2. Power Supply +ve Ordering Information Please supply: Part Number: Power Supply: Options: Z-PORT 24 Vdc RS232/485 version specify Z-PORT-RS

Z-HEAD UNIVERSAL INPUT ZIGBEE WIRELESS TRANSMITTER Battery Powered Wireless ZigBee Pressure Transmitter Wide Range of Inputs Including: RTD, Thermocouple, ma and Volts Long Battery Life, Low level Alarm Wide range of connection heads Complete Thermocouple, RTD, Pressure and Level probes available Description The Z-HEAD universal input ZigBee transmitter can accept a wide range of inputs from most process measurement devices and transmits the measured variable to a 2.4GHz ZigBee receiver unit. The Z-HEAD is specially designed to maximise battery life and in a typical application the battery life can exceed three years. The data update rate is user selectable to suit the requirement of each measured variable and so maximise battery life. Typical update rates include 1 second, 10 seconds, 60 seconds or 1 hour. The unit also transmits a signal strength reading which can be remotely monitored. The unit mounts in most standard process connection heads and complete assemblies are available for RTD, Thermocouple, Pressure and Level sensors. The Z-HEAD is designed to operate with the Z-200 or Z-PORT units. The Z-200 can output a 4-20mA or 0-10V signal whilst the Z-PORT can store up to 1024 variables for transmission to an Industrial Ethernet connection or an RS232/485 communications link. Inputs The input types and ranges included below are our standard ones only. Contact Sales for others. DC Current & Voltage 0-20mA, 4-20mA, 0-10mA into 15/30 Ω 0-1V, 0-10V, 1-5V into 100kΩ / 1MΩ Thermocouples Types E,J,K,N,R,S,T,B linearised or non-linearised Ranges: Wide range of inputs Cold junction compensation (can be turned off) Upscale or downscale t/c burnout options Resistance Thermometers 2, or 3 wire PT100, linearised or non-linearised. Wide range of inputs upscale or downscale burnout. Bridge Circuits Most standard bridge circuits with mv outputs. Pressure and Level Sensors A full range of ZigBee enabled pressure and level sensors are available, please see Pressure and Level Section Digital Inputs A module for digital inputs is available which can operate in counting mode or status on/off mode Z-PORT Ethernet or RS232 link

Parameter Min Typ Max Comments Supply Voltage 3.6V Battery Powered Supply Current (ma) 40 When transmitting data Input Impedance (Volt) 100kΩ Dependent on range, typical = 0-10V Operating Ambient -200ºC 70ºC Relative Humidity 0% 90% see note 1 Isolation Voltage 1kV Notes Installation Data Mounting Orientation Connections Conductor size Insulation Stripping Weight Enclosure Size In Head or wall mount Any Screw Clamp with pressure plate 0.5-4.0mm 12mm Approx 70g 85mm dia x 57mm deep Connection Details 1. Power Supply -ve 2. Power Supply +ve 3. Input +ve 4. Input -ve 5. RTD 3 rd wire 6. Bridge Excitation Ordering Information Please supply: Part Number: Z-HEAD Input Type: e.g ma, Volt, T/C, RTD Input Range: e.g 4-20, 0-10, 0-500ºC Power Supply: Battery powered

ISO-SLICE ISOLATED BUS I/O SYSTEM Universal Configurable input & outpus Communicates to Ethernet / RS232 or ZigBee Network Coordinator Inter-channel & input/output isolation Automatic Bus & Power connection via DIN rail bus connector Multiple inputs in one module Isolated Transmitter Supply Very High Accuracy, Low Cost Only 12.5mm Wide on DIN rail Description Inputs The new ISO-SLICE isolated Bus I/O system combines full three-port isolation with access to an industrial bus. This bus connects to the E-100, or Z-200 coordinator modules can then be used to transmit the process values via either Ethernet or RS232/485 wired communications or ZigBee wireless networks. A wide range of modules are available, from a single universal input to 8-way 4-20ma units. A selection guide is shown overleaf. Full 3 port isolation is standard as is an isolated transmitter supply which can be used to power any standard 2-wire 4-20mA transmitter. The input type and range can be user selected using simple DIL switches inside the unit. All RTD and Thermocouple inputs can be fully linearised. Non-interactive zero and span controls make adjustment and calibration of the unit quick and simple. The units have a wide ranging 12 to 36 Vdc. This supply can either be wired to the appropriate terminals or picked up automatically from the Bus connector. DC/AC Current & Voltage 0-20mA, 4-20mA, 0-10mA into 15Ω 0-1V, 0-10V, 1-5V into 1MΩ Min & Max Full Scale Ranges are: DC Current 0-1mA 0-5A Bipolar DC Current ±5mA ±10mA DC Voltage 0-1V 0-300V* Bipolar DC Voltage ±5V ±10V 2 Wire Pot 0-125Ω 0-1kΩ 3 Wire Pot 0-1kΩ 0-100kΩ * Note: For input voltages greater than 60Vdc a Divider unit must be specified. Thermocouples Types E,J,K,N,R,S,T,B linearised or non-linearised Ranges: Wide range of inputs Cold junction compensation (can be turned off) Upscale or downscale t/c burnout options For 4 channel t/c input specify -4 Resistance Thermometers 2, 3 or 4 wire PT100 or PT1000, linearised or non-linearised Ranges: Wide range of inputs Upscale or downscale RTD burnout options For 4 channel RTD module specify -3 Outputs DC Current and Voltage 0-20mA, 4-20mA, 0-10mA into 750Ω 0-1V, 0-10V, 1-5V into a minimum 100kΩ Others available up to a maximum of: Current: 0-20mA. Voltage: 0-10Vdc Frequency Input Wide range of freq inputs to 250kHz. Specify -7 Digital Input and Output modules 8 inputs, or 4 outputs Specify -5 or -6 Multi-input analogue modules 8 off 4-20mA or 0-10Vdc Modules Specify -2

Parameter Min Typ Max Comments Supply Voltage 12 24V 36Vdc Supply Current (ma) 45 90 For 24 V dc supply (260mA for 50mS on start up) Bus Connection 16-bit bus connection Input Impedance (Volt) 1MΩ Dependent on range (Typ=10V) Input Impedance( ma) 15Ω Dependent on range (Typ=20mA) Volt drop (ma input) 0.3 At 20mA input Output Linearity Error ±0.01% ±0.05% Temp Coefficient ±50ppm/ºC Load Resistance Error +/-5ppm/Ω 0 < R L < 750Ω Time Constant (10-90%) 25mS (fast) 60ms Selectable fast/normal response (normal) Operating Ambient 0ºC 55ºC Relative Humidity 0% 90% see note 1 Isolation Voltage 1kV Surge Voltage 2.5kV for 50µS Transient of 10kV/µS Notes Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur. Accuracy figures based on 24Vdc supply, 4-20mA output with 250Ω load and 20ºC ambient. Device is protected against reverse polarity connection. Installation Data Mounting Orientation Connections Conductor size Insulation Stripping Weight DIN Rail TS35 Any Screw Clamp with pressure plate 0.5-4.0mm 12mm Approx 95g Ordering Information Part Number Universal inputs ISOSLICE-1 1 ma or Vdc inputs ISOSLICE-2 8 RTD inputs ISOSLICE-3 4 Thermocouple inputs ISOSLICE-4 4 ISOSLICE-5 8 Digital inputs ISOSLICE-6 4 ISOSLICE-7 Freq Input Digital outputs

Z-TEMP AMBIENT TEMPERATURE and RH ZIGBEE TRANSMITTER Measures Ambient Temperature and Relative Humidity High accuracy, low cost unit Choice of enclosure types Long battery life User selectable update rates ZigBee Protocol Description Enclosure Styles The Z-TEMP ambient temperature and humidity transmitter has been designed to operate with the range of ZigBee components manufactured by Industrial Interface. Either ambient temperature alone or both temperature and humidity measurements can be specified. Typically the unit transmits the measured values back to a Z-PORT which can be connected to an Ethernet or RS232/485 communications network. The unit is specially designed to maximise battery life and in a typical application the battery life can exceed two years. Two mounting head styles are available, an industrial wall or ceiling mounting unit or a commercial style version. Accessories include a DIN rail mounting clip and cap retaining strap. Style Orientation Wall/Ceiling Mounting Enclosure Size Weight Industrial Head Any 2 x 3mm screws 85mm dia x 57mm deep Approx 70g Ordering Information Please supply: Part Number: X = 1 X = 2 Y = 1 Y = 2 For Example: Z-TEMP-1-2 Z-TEMP-X-Y Ambient Temp Only Ambient Temp and RH Industrial Enclosure Commercial Enclosure Ambient Temperature only in Commercial Enclosure Style Orientation Wall/Ceiling Mounting Enclosure Size Weight Commercial Enclosure Any 2 x 4mm screws / adhesive 80 x 80 x 22 mm Approx 70g Parameter Min Typ Max Comments Supply Voltage 3.6V Battery Powered Supply Current (ma) 40 When transmitting data Battery Life 2 Years Dependent on update rate Ambient Temperature Range -40ºC 80ºC Relative Humidity Range 0% 100% Temperature Accuracy +/- 0.5 deg C At 30 deg C Relative Humidity Accuracy +/- 3% Between 10 and 90% RH

Z-ROOT ZIGBEE NETWORK ROUTER Increases range of ZigBee sensors Can be connected to up to 20 sensors or sub-routers Choice of enclosure types AC or DC Powered versions ZigBee Protocol Low cost Description Enclosure Styles The Z-ROOT ZigBee network router has been designed to operate with the range of ZigBee components manufactured by Industrial Interface. Up to 20 sensors or sub-routers can be wirelessly connected to each Z-ROOT. Typically the unit transmits the measured values back to a Z-PORT which can be connected to an Ethernet or RS232/485 communications network. Two mounting head styles are available, an industrial wall or ceiling mounting unit or a commercial style version. Accessories include a DIN rail mounting clip and cap retaining strap. Style Orientation Wall/Ceiling Mounting Enclosure Size Weight Industrial Head Any 2 x 3mm screws 85mm dia x 57mm deep Approx 70g Ordering Information Please supply: Part Number: X = 1 X = 2 Y = 1 Y = 2 For Example: Z-ROOT-1-1 Z-ROOT-X DC Powered Unit AC Powered Unit Industrial Enclosure Commercial Enclosure DC Powered Z-ROOT ZigBee Router in Industrial Enclosure Style Orientation Wall/Ceiling Mounting Enclosure Size Weight Commercial Enclosure Any 2 x 4mm screws / adhesive 80 x 80 x 22 mm Approx 70g Parameter Min Typ Max Comments Supply Voltage 3.6dc 24Vdc 260 Vac Supply Current (ma) 40mA At 3.6Vdc when transmitting data Operating Ambient -40ºC 85ºC Temperature Range Relative Humidity Range 0% 90%

ZIGBEE ANTENNAE AND ACCESSORIES Wide range of Antennae, cables and connectors available Including ATEX certified units High-Gain industrial hardened units Cost-effective proven solutions Description ANT2401 Characteristics A wide range of ZigBee and other antennae are available from Industrial Interface, including ATEX rated antennae for hazardous areas. The ANTA7000 is typically used on the Z-PORT and Z-200 units where they are mounted in non-metallic enclosures so transmission through the panel is not a problem. The connections is an SMA male. The ANT2401 is a high gain antenna suitable for mounting on the outside of control panels or on internal or external walls. It has a high power teflon element protected by a glass fibre tube. Connection is via an N-Type female connector. The EX-ANT is optimised and certified for use in hazardous environments. It has a wide angle beam providing excellent coverage in multi path environments, for example where there are metal walls and equipment. For a full listing of devices available or technical assistance in choosing a suitable antenna please contact our sales department. Type Colinear Dipole Array Frequency Range 2300 2500 MHz Impedance 50 ohm unbalanced Gain 6 db Max Power 20 Watts (CW) at 50 degc Beamwidth Horiz 360 deg omni directional 3 db Beamwidth Vert 22 deg at 2242.5 MHz Feed System DC-Ground / Base Connector N- Type Female

A7000 Characteristics EX-ANT Characteristics Frequency Range Impedance Gain Temperature Vertical Beam Width Horiz Beam Width Max input power Connector Weight Length Radome material Wind survival Mounting Method 2400 & 5000 MHz 50 ohm 2 dbi -30 to +60 degc 80 degrees 360 degrees 2 Watts (Ex limitation) 10 metres cable 100g 125 mm EX certified plastic > 150 mph Wall / mast adaptor Min 24 cm Min 10 cm Installation Guide